• Title/Summary/Keyword: radiation detection

Search Result 767, Processing Time 0.028 seconds

Efficacy Evaluation of Alpha/Beta Radioactivity Screening in Urine Samples using Liquid Scintillation Counting

  • Ki Hoon Kim;Jae Seok Kim;Won Il Jang;Seokwon Yoon
    • Journal of Radiation Industry
    • /
    • v.18 no.2
    • /
    • pp.101-107
    • /
    • 2024
  • Rapid screening for internal contamination by alpha- and beta-emitting radionuclides is essential in situations involving radiation workers or radiation accidents. This study focused on the use of urine samples and liquid scintillation counting to quickly and accurately assess contamination. Calibration of the alpha and beta detection areas ensured precise measurement results. The major radionuclides recommended for surveillance during accidents were also considered. This study evaluated the effectiveness of the method by examining various parameters, including the limit of detection, linearity, sensitivity, selectivity, accuracy, ruggedness, and blind test sample analysis. The liquid scintillation counting method is an effective tool for screening urinary samples to detect alpha- and beta-emitting radionuclides, particularly during radiation emergencies, despite some limitations in precision.

Development of Radiation Detector with Intensifying Screen (증감지를 이용한 방사선검출기 개발)

  • Jeong-Min Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.859-863
    • /
    • 2023
  • In this study, simple and portable radiation detection system using X-ray intensifying screen, optical sensor and micro-controller unit for education was proposed. The system was simply composed of detection unit consisting of an optical sensor and intensifying screen, micro-controller unit, and was designed to be suitable for portable. Radiation was measured using developed detection system and absorbed dose dosimeter with changing tube voltage from 50 to 100 kVp. The tube current and SDD were fixed on 100 mAs and 100 cm, and dose were measured repeated ten times at each tube voltage. The response and linearity of the detection system were confirmed using the measured values. It was confirmed that the comparison measurement results of the detection system and absorbed dose dosimeter showed a high correlation(r : 0.998, p<.001). In this results, the feasibility of the detection system with intensifying screen and micro-controller unit based was confirmed, and we considered that the developed detection system could be applied to portable, compact, low cost system for education.

Peak detection algorithm at time domain of full-digital portable radiation detection system (휴대용 방사능 검출기의 시간 영역에서의 최고값 검출 알고리즘)

  • Hwang, Dong Gyu;Kim, Young Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.323-325
    • /
    • 2015
  • The purpose of the thesis is to suggest the algorithm that can be covered only by software instead of the function of pulse shaper that was used in the time domain. In order to implementing portable radiation detector for digital.

  • PDF

RADIATION-INDUCED OSTEOSARCOMA : REPORT OF A CASE (방사선 치료에 의해 발생한 골육종의 치험례)

  • Park, Kwan Soo;Lee, Yong Gyoo;Park, Hyo Sang;Kim, Jong Bae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.4
    • /
    • pp.379-382
    • /
    • 1998
  • The 44 years old man was consulted to our department due to restriction of mouth opening. On radiograph, we found bony expansive lesion at right mandibular ramus and temporal bone that it was suspected malignant tumor. So we had performed incisional bone biopsy at right ramus through skin incision. The result of biopsy was osteosarcoma. Then, he had experienced radiation therapy for the protection of recurrence after several times surgery of nasopharyngeal angiofibroma, 28 years ago. So, we concluded radiation induced osteosarcoma from his radiation therapy history. He had referred to the department of hematooncology because of severe expansion to skull base and was received 4 times chemotherapy with cisplatin and adriamycin, but he was expired just after 4th chemotherapy. Such radiation induced osteosarcoma have relative good prognosis due to rare metastasis from other reports. So if it will early detect from close follow up after radiation therapy, survival rate will rise up. But we missed early detection of our case. So, we report a case of rare radiation induced osteosarcoma. Ly detection of our case.

  • PDF

The Study for the Fast Detection of the Stereo Radiation Detector using the Image Processing (영상처리기반 스테레오 감마선 탐지장치의 고속탐지에 관한 연구)

  • Hwang, Young-gwan;Lee, Nam-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1103-1105
    • /
    • 2015
  • Leaked Radioactive source in nuclear power station, radiation related facilities and the aging nuclear power plant for the dismantling must need to detect and remove early to prevent major accidents. In this paper, we implemented a single sensor-based gamma-ray detectors stereo which can provide the distance to the radiation source, a direction and doserate information for fast and efficient decontamination work the radiation source. And we have carried out an algorithm development for high-speed detection of the detection equipment. Two detectors are required for stereo structure for obtaining the distance information of the radioactive source, but we designed the only sensor-based detection device for the weight reduction. We have extracted the region of interest and obtained the distance calculation result and distribution of radiation source in order to minimize a stereo image acquisition time. Detection time of the algorithm showed a shorter time of about 41%.

  • PDF

The Study of the Photo Diode Output Signal for Pusle Radiation Detection (펄스방사선 탐지를 위한 Photo Diode 출력특성 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.869-871
    • /
    • 2012
  • In this paper, we make silicon photodiodes for the detection of pulsed radiation that affects electronics devices and study the output characteristics of photodiodes using circuit design. We conducted the simulation for pulse sensing circuit and experimented the photodiode output characteristics using a high luminance light emitting diode. The results can be used for the design of the input sensor that is trigger of additional module for protecting a electoronics circuit from high energy pulse radiation.

  • PDF

Housing Analysis for Ocean Radiation Detection (해양 방사선 탐지를 위한 하우징 분석)

  • Park, Gang-teak;Kim, Jong-Yeol;Jung, Hyun-kyu;Lee, Nam-ho;Hwang, Young-gwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.714-715
    • /
    • 2017
  • Much of the interest in ocean radiation detection has been heightened as a lot of radioactivity has leaked to the ocean due to the accident at the Fukushima nuclear power plant in Japan. In the study, MCNP simulation for radiation detection in the ocean was performed. Unlike in the air, the marine environment must ensure the stability of the sensor from water depth, temperature, pressure, and salinity. In the marine environment, too much radiation is shielded. Therefore, it is an object to select a housing with a low radiation shielding ratio.

  • PDF

TinyML Gamma Radiation Classifier

  • Moez Altayeb;Marco Zennaro;Ermanno Pietrosemoli
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.443-451
    • /
    • 2023
  • Machine Learning has introduced many solutions in data science, but its application in IoT faces significant challenges, due to the limitations in memory size and processing capability of constrained devices. In this paper we design an automatic gamma radiation detection and identification embedded system that exploits the power of TinyML in a SiPM micro radiation sensor leveraging the Edge Impulse platform. The model is trained using real gamma source data enhanced by software augmentation algorithms. Tests show high accuracy in real time processing. This design has promising applications in general-purpose radiation detection and identification, nuclear safety, medical diagnosis and it is also amenable for deployment in small satellites.

Characteristics Analysis of SiPM for Detection of High Sensitivity of Portable Detectors (휴대용 검출기의 방사선 고감도 검출을 위한 SiPM 특성 분석)

  • Byung-Wuk Kang;Sun-Kook Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.897-902
    • /
    • 2023
  • The purpose of this paper is to analyze the characteristics of Silicon Photomultiplier (SiPM) for the realization of high-sensitivity radiation detection in portable detectors. Portable X-ray detectors offer the advantage of quickly accessing the patient's location and obtaining real-time images, allowing physicians to perform rapid diagnoses. However, this mobility comes with challenges in achieving accurate radiation detection. In existing detectors, SiPM is used for a simple purpose of detecting X-ray triggers. To verify the feasibility of high-sensitivity X-ray detection through SiPM, seven types of SiPM sensors were compared and selected, and their characteristics were analyzed. The SiPM used in the final test demonstrated the ability to distinguish signals at the ultra-low radiation level of 10 nGy, and it was observed that the slope of the signal rise curve varies with the X-ray tube voltage. Utilizing the characteristics of SiPM, which exhibits changes in signal level and duration with X-ray dose, it appears possible to achieve high-sensitivity measurements for X-ray detection.

Detection of Gamma-irradiated Imported Foods (Perilla seeds, Almonds, and Soybeans) by Using PSL, TL, and ESR (PSL, TL 및 ESR 분석을 통한 수입산 들깨, 아몬드 및 대두의 방사선 조사 여부 판별 특성)

  • Han, In-Jun;Yoon, Young-Min;Choi, Soo-Jeong;Song, Beom-Seok;Kim, Jae-Kyung;Park, Jong-Heum;Lee, Ju-Woon;Kim, Jae-Hun;Kim, Kyu-Heon;Cho, Tae-Yong;Yoon, Hae-Sung;Han, Sang-Bae;Lee, Jung-Eun
    • Journal of Radiation Industry
    • /
    • v.6 no.4
    • /
    • pp.305-310
    • /
    • 2012
  • This study examined radiation detection properties of imported perilla seeds, almonds, and soybeans. Food samples were irradiated at doses of 0.5, 1, 2, and 4 kGy and analyzed by photo-stimulated luminescence (PSL), thermoluminescence (TL), and electron spin resonance (ESR). The results of PSL showed that photon counts of irradiated perilla seeds and soybeans were $32,959counts{\cdot}60sec^{-1}$ and $7,234counts{\cdot}60sec^{-1}$, respectively, at an irradiation dose of 0.5 kGy, and the photon count of irradiated almonds was $5,581counts{\cdot}60sec^{-1}$ at an irradiation dose of 1 kGy. The results of TL showed that this technique is useful for detecting irradiated samples; the TL ratios ($TL_1/TL_2$) measured for the food samples at an irradiation dose of 0.5 kGy were 0.2301 for perilla seeds, 0.4595 for almonds, and 0.4827 for soy beans. Lastly, results of ESR spectroscopy for only soybeans revealed specific signals derived from free radicals captured in the cellulose. In conclusion, PSL, TL, and ESR methods can be used for the detection of gamma-irradiated soybean samples, whereas gamma-irradiated perilla seeds and almonds can be confirmed by a serial detection with a TL method after PSL.