• Title/Summary/Keyword: radiation application

Search Result 1,454, Processing Time 0.055 seconds

Application of Low Pressure Fogging System for Commercial Tomato Greenhouse Cooling (상업용 토마토온실 냉방을 위한 저압분무식 포그시스템의 적용)

  • Lee, Hyun-Woo;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.20 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • The objective of the present study is to identify the applicability of a low pressure fogging system for cooling commercial tomato greenhouse. In particular, the cooling system in this experiment utilizes low pressure spray nozzles which were developed in Korea recently. The experimental result that the temperature in fog-cooled greenhouse was lower than the non-cooled greenhouse showed the cooling effect by the low pressure fogging system. But because the relative humidity in fog-cooled greenhouse was comparatively low, the satisfactory cooling effect could be acquired by narrowing the space of fog nozzles and extending fogging time to supply more fog spray quantity. The variation of temperature distribution in fog-cooled greenhouse along timelag was insignificant during short time, but that was great during long period of day. This result showed the variation of temperature along timelag was slight by fog cooling but great by other factors like radiation, ventilation, air flow, etc. The advanced operation technology of fog system was required to reduce the variation of temperature along time lag. We plan to suggest the advanced installation and operation technology of low pressure fogging system for cooling commercial tomato greenhouse by further experiments in near future.

Effects of Persimmon leaf on the Photoaging Skin Improvement(1) (감잎의 광노화 피부 개선에 미치는 효과(1))

  • Lee, Chang Hyun;Kim, Nam Seok;Choi, Dong Seong;Oh, Mi Jin;Ma, Sang Yong;Kim, Myoung Soon;Ryu, Seung Jeong;Kwon, Jin;Shin, Hyun Jong;Oh, Chan Ho
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.6
    • /
    • pp.771-781
    • /
    • 2013
  • This study was performed to investigate the anti-photoaging effects of Persimmon leaf tea(PLT) in hairless mice(SKH-1) exposed to UVB irradiation. The animals were divided into non-treated group (normal, N) and UV-radiated groups. UV-radiated groups were divided into only UV-radiated group(control, C) and UV-radiated and PLT treated experimental groups[first extraction treated group(PLT-I), second extraction treated group(PLT-II), and third extraction treated group(PLT-III)]. Three PLT treated experimental groups of mice were treated with both oral administration(300 mg/Kg B.W./day) and topical application (100 ul of 2% conc./mouse/day) for 4 weeks. Anti-photoaging effects of Persimmon leaf were evaluated by anti oxidative reaction, stereomicroscopic and microscopic observations. The expression of photoaging skin related factors including mast cell tryptase, proliferating cell nuclear antigen (PCNA) and vascular endothelial growth factor (VEGF) was examined by immunohistochemical staining. Treatment of PLT-I, -II, -III prevented the wrinkle formation as well as epidermal hyperplasia, inflammatory cells, disruption of collagen in photoaged skin induced by UVB radiation. It also reduced the PCNA and VEGF expression in the UVB irradiated dorsal skin. Furthermore, it significantly decreased the number of mast cells in the UVB irradiated dermis(p<0.05 and p<0.01). On the effects of oxidative stress and antioxidant function on the treatment with water extract from Persimmon leaf tea(PLT), the activity of superoxide dismutase(SOD) was significantly increased in PLT-III group(p<0.05), and catalase(CAT) was significantly increased in PLT-I and PLT-III groups(p<0.05), and PLT-II group(p<0.001). These extracts showed relatively antioxidant activity and protective effect on UVB-induced oxidative stress in hairless mice(SKH-1). Our results suggest that Persimmon leaf tea may serve as an useful radical scavenging antioxidant and anti-photoaging skin agents in the UVB irradiated skin.

Evaluation of Lung Dose Using Linac Photon Beam in Geant 4 Simulation (Geant4 Simulation에서 Linac 광자선을 이용한 폐 선량평가)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.443-450
    • /
    • 2018
  • The Geant 4 simulated the linear accelerator (VARIAN CLINAC) based on the previously implemented BEAMnrC data, using the head structure of the linear accelerator. In the 10 MV photon flux, Geant4 was compared with the measured value of the percentage of the deep dose and the lateral dose of the water phantom. In order to apply the dose calculation to the body part, the actual patient's lung area was scanned at 5 mm intervals. Geant4 dose distributions were obtained by irradiating 10 MV photons at the irradiation field ($5{\times}5cm^2$) and SAD 100 cm of the water phantom. This result is difficult to measure the dose absorbed in the actual lung of the patient so the doses by the treatment planning system were compared. The deep dose curve measured by water phantom and the deep dose curve calculated by Geant4 were well within ${\pm}3%$ of most depths except the build-up area. However, at the 5 cm and 20 cm sites, 2.95% and 2.87% were somewhat higher in the calculation of the dose using Geant4. These two points were confirmed by the geometry file of Genat4, and it was found that the dose was increased because thoracic spine and sternum were located. In cone beam CT, the dose distribution error of the lungs was similar within 3%. Therefore, if the contour map of the dose can be directly expressed in the DICOM file when calculating the dose using Geant4, the clinical application of Geant4 will be used variously.

Resonant Characteristics in Rectangular Harbor with Narrow Entrance (2.Effects of Entrance Energy Loss) (개구부가 좁은 직사각형 항만의 공진 특성 (2.항입구 에너지 손실의 영향))

  • 정원무;박우선;서경덕;채장원
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.11 no.4
    • /
    • pp.216-230
    • /
    • 1999
  • A Galerkin finite element model for the analysis of harbor oscillation has been developed based on the extended mild-slope equation. Infinite elements are used to accomodate the radiation condition at infinity and joint elements to treat the matching conditions at the harbor entrance which include the energy loss due to flow separation. The numerical tests for rectangular harbors with fully or partially open entrances show that the energy loss at the harbor entrance considerably reduces the the amplification ratios at the innermost parts of the harbors and that the amplification ratios decrease considerably with increasing incident wave heights and jet lengths at the harbor entrance. Application of the model to the Gamcheon harbor show that when the incident wave amplitude is small the amplification ratios rather increase when the entrance energy loss is included than when ignored because of the shift of the resonance periods. Even though the entrance energy loss was insignificant for the measured long-period incident waves, it would be of great importance if the incident waves were large as in the attack of tsunamis. The resonance period of the Helmholtz mode at the Gamcheon Harbor was calculated to be 31 minutes, which agrees well with the measured one between 27 and 33.3 minutes. The measured resonance periods between 9.4 and 12.1 minutes and 5.2 and 6.2 minutes were also calculated by the numerical model as 10.4 minutes and 6.6 or 5.6 minutes, indicating good performance of the model. On the other hand, it was shown that a variety of oscillation modes exists in the Gamcheon Harbor and lateral resonances of considerable amplification ratios also exist at the periods of 3.6 and 1.6 minutes as in the Young-II Bay.

  • PDF

Research on Dose Reduction During Computed Tomography Scanning by CARE kV System and Bismuth (전산화 단층검사 시 Bismuth와 CARE kV System을 이용한 선량 저감화에 대한 연구)

  • Kwak, Yeong-Gon;Kim, Chong-Yeal;Jeong, Seong-Pyo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.8
    • /
    • pp.233-242
    • /
    • 2014
  • The purpose of this study is to compare the reduction of the dose radioactivity by CARE kV with that of the Bismuth shielding. First, CT was performed with transparent materials, including a Bismuth shielder which is a well-known material for decreasing the dose of radiation. Moreover, we have estimated and compared the affects of the reduction of dose on eye lens, thyroid, breast and genitals. These steps aim to compare reactions with and without the application of the Rando phantom with PLD as well as with CARE kV or not. As a result, during the Brain angio scan, the dose of CARE kV set inspection test methods showed the least dose. Depending on whether we use CARE kV, which showed the effect of dose reduction by 63%. During the Carotid angio scan, the dose was increased by 13% by how to set CARE kV+Bismuth. During the Cardiac angio scan, which showed the effect of dose reduction by 31% by how to set CARE kV+Bismuth. During the Lower extremity angio scan, the dose was measured least by how to set up the whole Bismuth. Compared with CARE kV set of test methods, which showed the effect of dose reduction by 9%.

Evaluation of Image Quality for Diagnostic Digital Chest Image Using Ion Chamber in the Total Mastectomy (변형근치유방절제술 환자의 Ion chamber 변화에 따른 디지털 흉부 영상의 화질 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Park, Hyong-Hu;Kim, Donghyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.3
    • /
    • pp.204-210
    • /
    • 2013
  • The patients who had been operated total mastectomy are different from general women in their breasts thickness due to breast surgery. As a result, digital chest image from total mastectomy patients will be different attenuation. The main objective for this study is to show that a proper Ion chamber standard combination measuring MTF which is objective basis for Digital image, when be x-ray for total mastectomy patient. We have designed the unique number that shown Left is 1, Right is 2, Center is 3 and have put the edge phantom on detector ion chamber. Lastly, we have obtained experiment images. The evaluations of all image quality have measured by 50% MTF of spatial resolution and absorption dose using Matlab(R2007a). The result showed that average exposure condition, MTF value, absorption dose for 1+3 and 2+3 combinations were 2.745 mAs, 1.925 lp/mm, 0.688 mGy. Consequently, that showed high MTF, DQE and low dose than other combinations. Therefore, a proper changes of ion chambers are able to improve image quality and to reduce radiation exposure when be X-ray for total mastectomy patients. Also, it will be possible to standard for application chamber combination and utilization on clinical detection.

An Efficient Correction Process of CT-Simulator Couch with Current Diagnostic CT Scanners (진단용 CT-모의치료기 테이블의 효율적인 교정 방법)

  • Goo, Eun-Hoe;Lee, Jae-Seung;Cho, Jung-Keun;Moon, Seong-Kwon
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.254-261
    • /
    • 2009
  • This study suggested that the table of CT-simulator and the laser alignment system using diagnostic CT scanner have an efficient method for improvement in alignment between the planned target center of traverse image with CT scanner. It was conducted on the daily QA when presented in the AAPM TG66 with correcting the laser alignment system using geometric trigonometric functions and investigated the effectiveness of correction methods as compared with those before and after correction. Before correction error was 3.82mm between the planned target center of image, the table longitudinal axis was twisted with 0.436o. The laser alignment system using geometric trigonometric functions in after correction was satisfied with tolerance limits of ${\pm}2mm$ when occurred about 0.7mm in errors between the planned target center. The table correction to satisfy the geometric accuracy is very inefficient over against the time and economic loss as well as technical limits in the case of application as only radiation therapy associated with CT-simulator with diagnostic CT scanner in use. But, the method which corrects the laser alignment system is economic and relatively simple with possibility of getting well geometric accuracy and we suppose that it is efficient method for applying in the clinic.

The phenomenological study of self-management intervention among breast cancer survivors: Non-pharmacological approaches (유방암 생존자들의 자가관리에 대한 현상학적 연구: 비약물적 접근방법을 중심으로)

  • Heo, Seok-Mo;Heo, Narae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.270-284
    • /
    • 2016
  • The purpose of this study was to understand the essential structure and meaning of self-management intervention for breast cancer survivors by using non-pharmacological approaches. The study participants were 10 breast cancer survivors who were completing cancer treatment that involved surgery, chemotherapy, and radiation therapy. Data collected between August 2014 and February 2015 at E Hospital in S city were analyzed by using Colaizzi's phenomenological method. Outcomes were classified into seven essential themes: 1) application of comfort measures to alleviate ongoing symptoms, 2) movement to change physical conditions, 3) special herbal intake to prevent recurrence, 4) a specially designed diet plan for health self-management, 5) constant awareness of complementary and alternative medicine, 6) unmet needs treated by one's own doctor's prescription, and 7) future life toward a nature-friendly environment. The study results contribute to a deeper understanding of self-management interventions in the daily lives of Korean breast cancer survivors. In addition, results provide an essential resource, based on actual self-management styles, that will help survivors to obtain guidance and participate in appropriate programs.

New Boron Compound, Silicon Boride Ceramics for Capturing Thermal Neutrons (Possibility of the material application for nuclear power generation)

  • Matsushita, Jun-ichi
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.15-15
    • /
    • 2011
  • As you know, boron compounds, borax ($Na_2B_4O_5(OH)_4{\cdot}8H_2O$) etc. were known thousands of years ago. As for natural boron, it has two naturally occurring and stable isotopes, boron 11 ($^{11}B$) and boron 10 ($^{10}B$). The neutron absorption $^{10}B$ is included about 19~20% with 80~81% $^{11}B$. Boron is similar to carbon in its capability to form stable covalently bonded molecular networks. The mass difference results in a wide range of ${\beta}$ values between the $^{11}B$ and $^{10}B$. The $^{10}B$ isotope, stable with 5 neutrons is excellent at capturing thermal neutrons. For example, it is possible to decrease a thermal neutron required for the nuclear reaction of uranium 235 ($^{235}U$). If $^{10}B$ absorbs a neutron ($^1n$), it will change to $^7Li+^1{\alpha}$ (${\alpha}$ ray, like $^4He$) with prompt ${\gamma}$ ray from $^{11}B$ $^{11}B$ (equation 1). $$^{10}B+^1n\;{\rightarrow}\;^{11}B\;{\rightarrow}\; prompt \;{\gamma}\;ray (478 keV), \;^7Li+4{\alpha}\;(4He)\;\;\;\;{\cdots}\; (1)$$ If about 1% boron is added to stainless steel, it is known that a neutron shielding effect will be 3 times the boron free steel. Enriched boron or $^{10}B$ is used in both radiation shielding and in boron neutron capture therapy. Then, $^{10}B$ is used for reactivity control and in emergency shutdown systems in nuclear reactors. Furthermore, boron carbide, $B_4C$, is used as the charge of a nuclear fission reaction control rod material and neutron cover material for nuclear reactors. The $B_4C$ powder of natural B composition is used as a charge of a control material of a boiling water reactor (BWR) which occupies commercial power reactors in nuclear power generation. The $B_4C$ sintered body which adjusted $^{10}B$ concentration is used as a charge of a control material of the fast breeder reactor (FBR) currently developed aiming at establishment of a nuclear fuel cycle. In this study for new boron compound, silicon boride ceramics for capturing thermal neutrons, preparation and characterization of both silicon tetraboride ($SiB_4$) and silicon hexaboride ($SiB_6$) and ceramics produced by sintering were investigated in order to determine the suitability of this material for nuclear power generation. The relative density increased with increasing sintering temperature. With a sintering temperature of 1,923 K, a sintered body having a relative density of more than 99% was obtained. The Vickers hardness increased with increasing sintering temperature. The best result was a Vickers hardness of 28 GPa for the $SiB_6$ sintered at 1,923K for 1 h. The high temperature Vickers hardness of the $SiB_6$ sintered body changed from 28 to 12 GPa in the temperature range of room temperature to 1,273 K. The thermal conductivity of the SiB6 sintered body changed from 9.1 to 2.4 W/mK in the range of room temperature to 1,273 K.

  • PDF

The Role of Serum Pepsinogen in Detection of Gastric Cancer (위암 검출에서 혈중 Pepsinogen검사의 의의)

  • Ryu, Hyong-Kyun;Park, Jeon-Woo;Lee, Keon-Ho;Jeon, Chang-Ho;Lee, Ho-Joon;Chae, Hyun-Dong
    • Journal of Gastric Cancer
    • /
    • v.9 no.4
    • /
    • pp.167-171
    • /
    • 2009
  • Purpose: This study was done to determine the usefulness of serum pepsinogen (PG) levels as a screening method for gastric cancer, and to assess the relationships between serum PG and clinicopathologic factors of gastric adenocarcinoma. Materials and Methods: Serum PG concentrations were measured in 94 subjects who were classified into (a) a control group (50 subjects) without abnormal endoscopic finding on a health checkup, or (b) a gastric cancer group (44 subjects) who had surgery at Daegu Catholic University Hospital between Nov. 2008 and May 2009. Receiver operator characteristic curves were utilized to select the most suitable test. Using different cutoff points, sensitivity and specificity were calculated. We compared preoperative serum PG levels with several clinicopathologic findings for patients with gastric adenocarcinoma. Results: The Serum PG I:II ratio was the most useful as a screening test. The sensitivity and specificity of PG screening for gastric cancer were, respectively, 81.8% and 82%. The cut off point correlated with the type of intestinal cancer (Lauren classification; P=0.003), tumor stage (P=0.001), and gastric adenocarcinoma with peritumoral chronic atrophic gastritis (P=0.036). Conclusion: Serum PG levels were found to be a potentially useful screening test and to correlate with clinicopathologic factors in gastric cancer patients. But, in order to use serum PG found in a health checkup for gastric cancer as a clinical application a large scale study is recommended.

  • PDF