• Title/Summary/Keyword: radiation analysis

Search Result 4,663, Processing Time 0.039 seconds

Analysis of changes in dose distribution due to respiration during IMRT

  • Shin, Jung-Suk;Shin, Eun-Hyuk;Han, Young-Yih;Ju, Sang-Gyu;Kim, Jin-Sung;Ahn, Sung-Hwan;Kim, Tae-Gyu;Jeong, Bae-Kwon;Park, Hee-Chul;Ahn, Young-Chan;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.29 no.3
    • /
    • pp.206-213
    • /
    • 2011
  • Purpose: Intensity modulated radiation therapy (IMRT) is a high precision therapy technique that can achieve a conformal dose distribution on a given target. However, organ motion induced by respiration can result in significant dosimetric error. Therefore, this study explores the dosimetric error that result from various patterns of respiration. Materials and Methods: Experiments were designed to deliver a treatment plan made for a real patient to an in-house developed motion phantom. The motion pattern; the amplitude and period as well as inhale-exhale period, could be controlled by in-house developed software. Dose distribution was measured using EDR2 film and analysis was performed by RIT113 software. Three respiratory patterns were generated for the purpose of this study; first the 'even inhale-exhale pattern', second the slightly long exhale pattern (0.35 seconds longer than inhale period) named 'general signal pattern', and third a 'long exhale pattern' (0.7 seconds longer than inhale period). One dimensional dose profile comparisons and gamma index analysis on 2 dimensions were performed. Results: In one-dimensional dose profile comparisons, 5% in the target and 30% dose difference at the boundary were observed in the long exhale pattern. The center of high dose region in the profile was shifted 1 mm to inhale (caudal) direction for the 'even inhale-exhale pattern', 2 mm and 5 mm shifts to exhale (cranial) direction were observed for 'slightly long exhale pattern' and 'long exhale pattern', respectively. The areas of gamma index >1 were 11.88 %, 15.11%, and 24.33% for 'even inhale-exhale pattern', 'general pattern', and 'long exhale pattern', respectively. The long exhale pattern showed largest errors. Conclusion: To reduce the dosimetric error due to respiratory motions, controlling patient's breathing to be closer to even inhaleexhale period is helpful with minimizing the motion amplitude.

A Discussion for Alteration of the Radiation Issues Based on the Clipping Analyses of Radiation Articles Reported in Korea

  • Kim, Joo Yeon;Youn, Dol Mi;Yoo, Ji Yup;Park, Tai Jin
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.161-165
    • /
    • 2016
  • Background: Radiation accidents having occurred in recent containing the accident in Fukushima nuclear power plants of Japan were resulted to the increase in some public concern, anxiety and confusion for radiation or nuclear safety. The public anxiety for radiation is not being decreased though the announcements done in radiation research institutes in Korea. Therefore, this study aims at providing an effective system for radiation publicity to the public members by the clipping analysis for the radiation articles reported in the media. And, the relation between those radiation issues and the radiation perception to the public members is analyzed. Materials and Methods: The radiation articles reported by them in 2013 and 2014 have been collected, and they are then classified with the article characteristic, field and tendency. Classified articles have been reviewed by dividing as two year. The 210 articles have been compared for their tendencies, characteristics and fields by year reported, and their characteristic comparison by reported year are then reviewed. Results and Discussion: Though the frequency that the radiological accidents have occurred in worldwide is far low compared to the accidental frequencies occurred in the general industrial fields, the radiation perception is being still deteriorated because of its special problem, which is defined as exposure, contamination or radioactivity, about radiation. The basic principles for radiation communication were suggested for preventing some unnecessary misunderstanding due to the variation of understanding for radiation issues. Conclusion: It is necessary to perform a variety of strategies for the publicity in improving the radiation perception, to build a relationship with the press or the media and then to consistently interact with them. Radiation communication must be performed by radiation experts or complete charge department, and must be consistently performed and be taken predictable patterns.

Analysis of Direct and Diffuse Radiation in Plastic Greenhouse (플라스틱 하우스의 직달(直達) 및 산란(散亂) 일사량(日射量) 해석(解析))

  • Koh, Hak-Kyun;Kim, Moon-Ki;Kim, Yong-Hyeon
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.13-24
    • /
    • 1989
  • Direct and diffuse components of solar radiation were measured inside and outside a single-span plastic greenhouse. To analyze the direct solar radiation inside the plastic greenhouse, the cross-section of the greenhouse was assumed to be circular. Then the direct solar radiation transmitted into the greenhouse was calculated theoretically, and compared with the experimental measurements. The results are summarized as follows: (1) The transmissivities of total solar radiation were about 65% on cloudy days and 50% on clear days. For cloudy days, the transmissivity of the total solar radiation was regarded as the transmissivity of sky diffuse radiation. (2) The ratio of the inside effective scattered component of direct solar radiation to the diffuse radiation was 60-65%. (3) It appeared that the seasonal variation of the transmissivity of total solar radiation was adversely affected by the transmissivity of direct solar radiation and the effective scattered coefficient. But the effect of the transmissivity of direct solar radiation was dominant factor. (4) Computer simulation showed that the inside direct solar radiation was decreased as the floor of the plastic greenhouse was higher. (5) The predicted value of the inside direct solar radiation was 3.3% to 29.0% higher than the measured value.

  • PDF

Design of radiation detection circuit for gamma column scanning (자동 감마 증류탑 검사 장치를 위한 방사선 계측장치 설계)

  • Kim, Jong-Beom;Jeong, Seong-Hui
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.612-615
    • /
    • 2003
  • In this paper, a design of radiation detector for gamma column scanner is introduced. Distillation column is important unit in Petro-chemical industries, and its on-line diagnose is very important. To get density profile measured by the radiation transmitted through column is well method for on-line diagnose as gamma scanning. For this purpose radiation detection circuit, radiation source and mechanical system for moving source and detector are required. Conventional radiation detection circuit for this application is sensitive to electric noise because of interface between the radiation circuit and the controller for mechanical system. The radiation detection system introduced here is using loop coil instead of slip ring to remove contact noise. Radiation detection system designed here for gamma scanning consist of BGO detector, high voltage circuit, PHA circuit and FSK modem. The BGO detector is used as radiation sensor, high voltage circuit and peak height analysis circuit is essential to process the signal generated from BGO detector. Micro controller convert measured data into ASCII data. FSK modem transmit ASCII data. Transmitted ASCH data is picked up in antenna coil and processed for combined function with mechanical system. This method gives good result by isolating the controlling circuit of mechanical system from radiation detecting circuit which is sensitive to noise.

  • PDF

Study of Radiation Safety Management of Veterinary Hospital in Korea (동물병원 방사선 안전관리체계에 대한 연구)

  • Chae, Soo-young;Choi, Ho-jung;Lee, Young-won
    • Journal of Veterinary Clinics
    • /
    • v.37 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • This study investigated the effectiveness of radiation safety rules in animal hospital and the awareness and behavior of veterinary radiation workers. With the questionnaires, the data was collected from randomly selected veterinarians in animal hospitals and animal medical imaging centers. Collected data were about radiation device, shielding device, regulations, safety management, education, knowledge, behavior and awareness. Frequency, correlation and multiple regression analysis were performed. The medical devices related with radiation in animal hospital were X-ray (59%), CT (15%), fluoroscopy (12%), mobile X-ray (12%) and others (2%). The number of people using radiation shielding device is high. The answers were low on knowing radiation related regulation and receiving radiation protection education. The group with higher knowledge and awareness shows positive correlation with safety behavior. The increase of use of the radiation related medical devices in veterinary hospital causes the increase of radiation exposure risk. This study suggests that radiation safety management system and policies need to be developed to protect radiation workers and give them correct information and consciousness.

Analysis of the Transmissivities of Direct and Diffuse Solar Radiation in Multispan Glasshouse (연동 유리온실내의 직달일사 및 산란일사 투과율 해석)

  • 김용현;이석건
    • Journal of Biosystems Engineering
    • /
    • v.23 no.5
    • /
    • pp.439-444
    • /
    • 1998
  • Effects of the number of spans, orientation and latitude on the transmissivities of direct and diffuse solar radiation in multispan glasshouse were analyzed using a computer simulation model (Kim and Lee, 1997). The number of spans did not affect the transmissivity of diffuse solar radiation, ranging 60∼61%. The transmissivities of direct solar radiation were 55∼64% for E-W orientation and 47∼70% for N-S orientation in ten multispan glasshouse. There was no effect of the latitude on the transmissivity of direct solar radiation in domestic regions. Differences in the transmissivity of direct solar radiation between single-span and multispan glasshouse were significant for E-W orientation during winter season; however, those were relatively small for N-S orientation throughout the year. Transmissivity of direct solar radiation decreased with the increasing number of spans for E-W glasshouse, whereas those for N-S glasshouse was hardly affected by the number of spans.

  • PDF

RADIATION-INDUCED DISLOCATION AND GROWTH BEHAVIOR OF ZIRCONIUM AND ZIRCONIUM ALLOYS - A REVIEW

Molecular Weight Control of Chitosan Using Gamma Ray and Electron Beam Irradiation

  • Kim, Hyun Bin;Lee, Young Joo;Oh, Seung Hwan;Kang, Phil Hyun;Jeun, Joon Pyo
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.51-54
    • /
    • 2013
  • Chitosan is a useful natural polymer material in many application fields such as biomaterials, water-treatment, agriculture, medication, and food science. However, the poor solubility limits its application. In this study, the effects of radiation on chitosan were investigated using gamma ray and electron beam irradiation. The chemical structure and molecular weight analysis show similar degradation effects of chitosan powder in both gamma ray and electron beam irradiation. However, the radiation irradiated chitosan in $H_2O$ has a lower molecular weight, since the hydroxyl radicals attack the glycosidic bonds. This effect is more clearly shown in the electron beam irradiation results.

Heat Transfer Analysis of the Radiation Shield in Cryogenic Systems (극저온 시스템의 복사쉴드의 열전달 해석)

  • 정은수;박희찬;양형석;장호명
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.177-180
    • /
    • 2002
  • A numerical model to obtain the temperature distribution in a radiation shield of cryogenic systems was proposed. Conformal mapping was used to transform the eccentric physical region of the upper plate to the concentric numerical region. The effects of the thickness of the radiation shield, the emissivities of the vacuum chamber and the radiation shield, and the eccentricity between the centers of the upper plate and the contact area with a cryocooler on the maximum temperature difference in a radiation shield were shown.

  • PDF

Refining prognostic stratification of human papillomavirus-related oropharyngeal squamous cell carcinoma: different prognosis between T1 and T2

  • Lee, Sumin;Lee, Sang-wook;Park, Sunmin;Yoon, Sang Min;Park, Jin-hong;Song, Si Yeol;Ahn, Seung Do;Kim, Jong Hoon;Choi, Eun Kyung;Kim, Su Ssan;Jung, Jinhong;Kim, Young Seok
    • Radiation Oncology Journal
    • /
    • v.35 no.3
    • /
    • pp.233-240
    • /
    • 2017
  • Purpose: To validate the 8th edition of the American Joint Committee on Cancer/Union for International Cancer Control (AJCC/UICC) TNM staging system for human papillomavirus (HPV)-related oropharyngeal squamous cell carcinoma (OPSCC) and investigate whether a modified classification better reflects the prognosis. Materials and Methods: Medical records of patients diagnosed with non-metastatic HPV-related OPSCC between 2010 and 2016 at a single institution were retrospectively reviewed. HPV status was determined by immunohistochemical analysis of p16 and/or HPV DNA polymerase chain reaction (PCR). We reclassified TNM stage T0-1 and N0-1 as group A, T2-3 or N2 as B, and T4 or N3 as C. Survival analysis according to 8th AJCC/UICC TNM staging and the modified classification was performed. Results: Of 383 OPSCC patients, 211 were positive for HPV DNA PCR or p16. After exclusion, 184 patients were included in this analysis. Median age was 56 years (range, 31 to 81 years). Most primary tumors were in the palatine tonsil (148 tumors, 80%). The eighth AJCC/UICC TNM classification could not differentiate between stage I and II (p = 0.470) or II and III (p = 0.209). Applying modified grouping, the 3-year overall survival rate of group A was significantly higher than that of group B and C (98% vs. 91%, p = 0.039 and 98% vs. 78%, p < 0.001, respectively). Differentiation between group B and C was marginally significant (p = 0.053). Conclusion: The 8th AJCC/UICC TNM staging system did not clearly distinguish the prognosis of stage II from that of other stages. Including the T2N0-1 group in stage II may improve prognostic stratification.