자기 컴퍼스 방위지시부의 수반각 (The Concomitant angle of the Directional System of Magnetic Compass)

  • 안영화;정공흔;신형일
    • 수산해양기술연구
    • /
    • 제22권3호
    • /
    • pp.17-22
    • /
    • 1986
  • This paper investigates on the performance of liquid magnetic compass measuring the concomitant angle of the directional system by the kind of compass and the coefficiant of viscosity of the liquid of ones in accordance with the turning angular velocity of the compass bowl in artificial horizontal magnetic fields. The obtained results are as follows; 1. The concomitant angle is to be in proportion to the coefficiant of viscosity of the liquid of compass and the turning angular velocity of the compass bowl, but ones is to be in contrary proportion to the magnetic moment of the magnetic needle and the horizontal geomagnetic. 2. The overdevelopment of the concomitant angle keeps on regularly at any optional degree in the turning angular velocity over$\pi$ radian per minute, but varies periodically at 180 degree below 3 $\pi$ radian per minute.

  • PDF

사각판 스티프너로 보강한 콘크리트 충전강관 기둥과 H형강 보 접합부의 내진성능 (Seismic Performance of Wide Flange Beam-to-Concrete Filled Tube Column Joints with Stiffening Plates around the Column)

  • 박종원;강승민;김욱종
    • 한국강구조학회 논문집
    • /
    • 제15권2호
    • /
    • pp.167-174
    • /
    • 2003
  • 본 연구는 보 플랜지와 스티프너의 용접부 양단, 기둥 모서리 부분 스티프너에 라운드를 두는 방법 등을 통하여 총 7개 시험체에 실물대 반복하중실험을 실시한 결과를 나타낸 것이다. 실험 결과를 통하여 다음과 같은 결론을 얻을 수 있었다. (1) 필레(fillet)를 둠으로써 응력집중을 줄여 내진성능을 크게 향상 시킬 수 있다. (2) 스티프너 폭의 증가로 접합부의 강성 및 강도는 증가하였지만 에너지 소산 능력은 감소하였다. (3) 모든 시험체는 규준에서 강진지역의 내진구조에 대해 요구하는 총 0.04 radian의 회전각을 발휘할 수 있는 것으로 나타났다.

텔레매틱스 단말기 GUI의 설계에 관한 연구 -Menu Type, Structure, Font Size에 관하여- (A Study of Graphic User Interface at the Telematics Display on Driving)

  • 홍화현;박범
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2006년도 학술대회 1부
    • /
    • pp.599-607
    • /
    • 2006
  • 텔레매틱스 정보단말기는 가독성, 시인성, 주행 안전성의 사용성과 HMI(Human Machine Interface)를 고려하여 설계해야 한다. 텔레매틱스 정보단말기 GUI을 구성하는 요소로 Menu Type, Menu Structure, Font Size 등이 있다. 그러나 한글이라는 지역적 특성에 대한 연구가 미흡한 상태이다. 따라서 본 연구에서 국내 운전자를 대상으로 텔레매틱스 정보단말기 GUI Factor에 대해 국내의 환경에 맞는 설계를 도출하였다. 피험자는 총 30명(남자 24명과 여자6명)을 대상으로 가상 주행 시스템을 이용한 시뮬레이션 환경에 Task를 수행하도록 하여 실험을 하였다. 분석은 ANOVA, 다원배치법, T-test, Font 일반식 대입을 통해 이루어졌다. Menu Type은 가로세로 2*3 배열의 형태와 버튼간 간격을 주행안전성 및 시인성에서 고려하여 설계해야 한다. Menu Structure는 3Depth가 3Frame 보다 주행안전성 및 시인성이 5%유의수준에서 더 우수하다고 나타났다. 운전자 안구 거리에 따른 Font Size를 도출하는 일반식은 어두운 글자인 경우 0.0069radian * d = Font Size 가 되고, 밝은 글자인 경우 0.0075radian * d = Font Size 가 된다. 위와 같이 본 연구는 GUI 세가지 항목에 대하여 국내 운전자의 사용성과 텔레매틱스 정보단말기 간의 인터페이스를 고려하여 기존의 시스템에 대하여 에러를 줄이고, 수행능력을 향상 시켜 주었다.

  • PDF

쐐기형 강재 접합장치를 사용한 보-기둥 접합부의 내진성능 (Seismic Performance of Beam-to-Column Joints with Wedge Connectors)

  • 박종원;강승민;황인규
    • 한국강구조학회 논문집
    • /
    • 제19권6호
    • /
    • pp.655-661
    • /
    • 2007
  • 강재의 접합형식으로 쐐기의 원리를 이용한 새로운 접합장치인 쐐기형 접합장치(wedge connectors)가 개발되었다. 본 연구에서는 새로운 접합장치를 적용한 철골 보-기둥 접합부의 내진성능에 대한 실험연구를 수행하였다. 새로운 접합장치를 적용한 2개의 보-기둥 접합부 시험체에 대해 반복하중 실험을 수행하였다. 2개의 시험체는 켄티레버형이며 동일한 상세를 갖도록 제작되었다. 반복하중 실험의 결과 2개의 시험체 모두 특수모멘트골조에 대해 요구되는 총회전각인 0.04 라디안보다 큰 0.06라디안의 총회전각을 발휘할 수 있었으며 기존의 보-기둥 접합형식에 비해 에너지 소산능력이 크게 우수한 것으로 나타났다.

Effects of near-fault loading and lateral bracing on the behavior of RBS moment connections

  • Yu, Qi-Song Kent;Uang, Chia-Ming
    • Steel and Composite Structures
    • /
    • 제1권1호
    • /
    • pp.145-158
    • /
    • 2001
  • An experimental study was conducted to evaluate the effects of loading sequence and lateral bracing on the behavior of reduced beam section (RBS) steel moment frame connections. Four full-scale moment connections were cyclically tested-two with a standard loading history and the other two with a near-fault loading history. All specimens reached at least 0.03 radian of plastic rotation without brittle fracture of the beam flange groove welds. Two specimens tested with the nearfault loading protocol reached at least 0.05 radian of plastic rotation, and both experienced smaller buckling amplitudes at comparable drift levels. Energy dissipation capacities were insensitive to the types of loading protocol used. Adding a lateral bracing near the RBS region produced a higher plastic rotation; the strength degradation and buckling amplitude were reduced. A non-linear finite element analysis of a one-and-a-half-bay beam-column subassembly was also conducted to study the system restraint effect. The study showed that the axial restraint of the beam could significantly reduce the strength degradation and buckling amplitude at higher deformation levels.

접합부 회전성능에 따른 중간 철골 모멘트 골조의 내진 성능 평가 - I 성능평가 (Seismic Performance Evaluation According to Rotation Capacity of Connections for Intermediate Steel Moment Frames - I. Performance Evaluation)

  • 문기훈;한상환;하성진
    • 한국지진공학회논문집
    • /
    • 제18권2호
    • /
    • pp.95-103
    • /
    • 2014
  • The current AISC341-10 standard specifiesa value of 0.02 radian for the minimum rotation capacity of connections for the intermediate steel moment frame system. However, despite of the advances realized in the domains of performance evaluation method and analysis method, research onthe minimum rotation capacity of the intermediate steel moment frame systemsatisfying the seismic performance has not been conducted in detail. In this study, the intermediate moment frame systemisdesigned with respect to current standards and the seismic performance in accordance with the rotational capacity of connections is evaluated using the seismic performance evaluation method presented in FEMA-P695. The minimum rotation capacity of intermediate steel moment frames required to satisfy seismic performance as well as the major design values affecting the seismic performance of moment frame areestimated. To that goal, the design parameters are selected and various target frames are designed. The analysis models of the main nonlinear elements are also developed for evaluating seismic performance. The resultsshow that the 20-story structure doesnot meet the seismic performance even if it satisfies the rotation capacity of 0.02 radian.

퍼지 학습법을 이용한 crane의 과도 진동 제어 (Control for crane's swing using fuzzy learning method)

  • 임윤규;정병묵
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.450-453
    • /
    • 1997
  • An active control for the swing of crane systems is very important for increasing the productivity. This article introduces the control for the position and the swing of a crane using the fuzzy learning method. Because the crane is a multi-variable system, learning is done to control both position and swing of the crane. Also the fuzzy control rules are separately acquired with the loading and unloading situation of the crane for more accurate control. The result of simulations shows that the crane is just controlled for a very large swing angle of 1 radian within nearly one cycle.

  • PDF

엑스선 간섭계를 이용한 초정밀측정 (Nanometrological Application of X-ray Interferometry)

  • 엄천일
    • 한국정밀공학회지
    • /
    • 제17권6호
    • /
    • pp.40-45
    • /
    • 2000
  • 교정은 모든 측정분야에서 어렵고 까다로운 주제인데, 특히 정전센서, 레이저간섭계, AFM, STM 등을 포함하는 나노메트롤로지(nanometrology : 나노측정) 분야에서는 그러하다. 나노측정에서는 전체 측정범위가 센서들의 한계분해능 값과 비슷한데, 이러한 측정에서 높은 소급성을 유지하기는 매우 어렵기 때문이다.(중략)

  • PDF

보 플랜지 절취형 (RBS) 철골 모멘트 접합부의 균형패널존 강도 (A Balanced Panel Zone Strength Criterion for Reduced Beam Section Steel Moment Connections)

  • 이철호;김재훈;전상우;김진호
    • 한국강구조학회 논문집
    • /
    • 제18권1호
    • /
    • pp.59-69
    • /
    • 2006
  • 본 연구에서는 보 플랜지 절취형 (Reduced Beam Section, RBS) 철골모멘트접합부의 실험결과를 기초로 패널존의 적정강도를 제시하고자 하였다. RBS 충분한 실험자료가 보고 되어 있음에도 불구하고, 패널존의 적정강도 범위가 아직 제시된 바가 없다. 본 연구 및 다른 연구자의 실험결과에 의할 때, 패널존은 보 플랜지 그루브 용접부에 유해한 영향을 미치지 않고 0.01 radian의 소성회전각을 무난하게 발휘할 수 있음이 확인되었다. 또한 이 정도 크기의 패널존 소성변형을 허용하면 강한 패널존 시험체에 비해 횡비틀림 좌굴의 진폭이 절반 정도로 감소하였다. 이러한 실험적 관측을 토대로 RBS접합부의 소성변형능력을 향상시킴과 동시에 보의 소성힌지에 발생하는 좌굴의 크기를 줄일 수 있는 균형 패널존에 대한 강도 기준을 제안하였다.

리브로 보강된 철골 모멘트 접합부의 내진거동에 관한 실험적 연구 (An Experimental Study of Cyclic Seismic Behavior of Steel Moment Connections Reinforced with Ribs)

  • 이철호;이재광;정종현;오명호;구은숙
    • 한국강구조학회 논문집
    • /
    • 제14권4호
    • /
    • pp.499-508
    • /
    • 2002
  • 리브로 보강된 철골 모멘트 내진접합부에 대한 실용적이고 간단한 설계법이 등가스트럿 모델을 바탕으로 최근에 제안된 바가 있다. 본 논문에서는 제안된 설계법을 검증하고 응력집중에 의한 리브 단부의 균열방지 방안을 모색하기 위한 실험결과를 기술하였다. 제안된 설계법에 의해 설계된 모든 실물대 시험체는 접합부의 소성회전각이 0.04(radian)에 이르는 뛰어난 내진성능을 발휘하였다. 접합부를 리브로 보강함과 동시에 보의 플래지 일부를 잘라내어 보의 소성힌지와 국부좌굴의 발생위치를 리브의 끝단으로부터 보 안쪽으로 약간 이동시킴으로서, 리브단부의 균열발생을 효과적으로 제어할 수 있음을 실험적으로 확인하였다. 또한 리브의 스트럿 작용과 이로 인한 보 웨브에서의 전단역전을 스테레인 게이지 계측을 통하여 실험적으로 입증하였다.