• 제목/요약/키워드: radial

검색결과 5,359건 처리시간 0.038초

모멘트 하중을 고려한 깊은 홈 볼 베어링의 정등가 하중에 관한 연구 (The Static Equivalent Radial Load under the Moment and Radial Force for the Deep Groove Ball Bearings)

  • 이재선;한동철
    • Tribology and Lubricants
    • /
    • 제14권3호
    • /
    • pp.94-99
    • /
    • 1998
  • Generally not only the radial load but also the moment may be applied to the ball bearings for a shaft system. However it has been difficult to determine the static equivalent load because there is the radial static equivalent equation only for the axial and radial force on the bearings. In this paper, the same static equivalent radial load which makes the maximum contact force at the interface between the ball and groove as the applied radial force and moment generate is calculated under the condition that the radial force and the moment are applied to the bearings simultaneously. The relation between the static equivalent load and applied force is studied. Therefore the simple and effective equation for the static equivalent radial load of the radial load and moment is proposed for the deep groove ball bearings.

Radial Force Control of a Novel Hybrid Pole BLSRM

  • Wang, Hui-Jun;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.845-853
    • /
    • 2009
  • This paper presents a novel hybrid pole BLSRM (Bearingless Switched Reluctance Motor) and its radial force control scheme. The proposed hybrid pole BLSRM has separated radial force poles and rotating torque poles. According to the FEM analysis, the proposed BLSRM has an excellent linear characteristic of radial force and controllability that is independent from the torque current. The radial force can be produced by the radial force winding which is wound at the separated radial force poles. The rotating torque is produced by the excitation current of the torque windings which are wound at the torque pole. The proposed radial force control scheme is independent of the phase torque winding current. A simple PID controller and look-up table are used to maintain a constant rotor air-gap. The proposed BLSRM and its radial force control scheme are verified by FEM analysis and experimental tests.

인영.촌구 대비법을 이용한 맥 진단 시스템 구현 (Implementation of Radial Pulse Diagnosis System using Inyoung-Cheongu Comparison Method)

  • 이호재;박영배;허웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권1호
    • /
    • pp.73-80
    • /
    • 1993
  • This paper describes the implementation of a computerized radial pulse diagnosis by Elds of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diag nosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed It. Then, we have got the characteristic parameters of radial pulse wave and also quantified thats according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial Pulse diagnosis system and then we confirmed the PossibiliLy for realization of automatic radial Pulse diagnosis in korean traditional medicine.

  • PDF

원위 전완부에서 요골 동맥의 주행 변이로 발생된 표재성 요골 신경 압박증 - 1례 보고 - (Compression Neuropathy of Superficial Radial nerve by Variation of Course of Radial Artery in Distal Forearm - A case report -)

  • 김종관;안병우;곽완섭;조제일;김우식;윤종호
    • Archives of Reconstructive Microsurgery
    • /
    • 제15권1호
    • /
    • pp.38-41
    • /
    • 2006
  • A 57-year-old male suffered from tingling and paraesthesia on radial side of right hand. We carried out exploration, the process being done, a radial artery passing between the two branches of bifurcated superficial radial nerve was found by accident. Then we performed dissection of the radial artrery a little more distally. It was passing above the extensors of thumb to anstomical snuff box. We treated it with ligating the radial artery, which was done a little above the bifurcated site of superficial radial nerve after angiography of upper extremity. While we were following this procedure, we noticed that symptoms had improved a lot. To our knowlege, neuropathy, by itself of superficial radial nerve by the radial artery with anatomical variation has never been reported and therefore we report this case.

  • PDF

Immobilization of Heparin onto the Polyurethane

  • Cho, Chong-Su;Kim, Sung-Wan
    • 대한의용생체공학회:의공학회지
    • /
    • 제7권2호
    • /
    • pp.147-150
    • /
    • 1986
  • This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine.

  • PDF

Unusual anomaly of the radial artery encountered during the elevation of a radial forearm free flap: a case report

  • Jin Myung Yoon;Tae Jun Park;Sae Hwi Ki;Min Ki Hong
    • 대한두개안면성형외과학회지
    • /
    • 제24권1호
    • /
    • pp.28-31
    • /
    • 2023
  • The radial forearm free flap (RFFF) has become popular for head and neck reconstructions. Owing to a constant anatomy the RFFF is relatively easy to dissect. Nevertheless, anatomical variations of the radial artery have been reported. Some variations could affect the survival of the flap. This paper reports an unusual anomaly of the radial artery where the radial artery was not located between the brachioradialis (BR) and flexor carpi radialis. The radial artery was observed above the BR and on the radial side of the BR. The survival of the elevated flap was deemed questionable because it had only few perforators. So we decided to discard the flap and to elevate another free flap for the head and neck defect. The donor area on the forearm was covered using the original skin of the first flap as a full-thickness skin graft. This case highlights a means to deal with anomalies of the radial artery encountered during the elevation of RFFF and the checking process for variations of the radial artery before RFFF.

Radial Thrust of Single-Blade Centrifugal Pump

  • Nishi, Yasuyuki;Fukutomi, Junichiro;Fujiwara, Ryota
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권4호
    • /
    • pp.387-395
    • /
    • 2011
  • Single-blade centrifugal pumps are widely used as sewage pumps. However, the impeller of a single-blade pump is subjected to strong radial thrust during pump operation because of the geometrical axial asymmetry of the impeller. Therefore, to improve pump reliability, it is necessary to quantitatively understand radial thrust and elucidate the behavior and mechanism of thrust generating. This study investigates the radial thrust acting up on a single-blade centrifugal impeller by conducting experiments and CFD analysis. The results show that the fluctuating component of radial thrust increases as the flow rate deviates from the design flow rate to low or high value. Radial thrust was modeled by a combination of three components, inertia, momentum, and pressure by applying an unsteady conservation of momentum to the impeller. The sum of these components agrees with the radial thrust calculated by integrating the pressure and the shearing stress on the impeller surface. The behavior of each component was shown, and the effects of each component on radial thrust were clarified. The pressure component has the greatest effect on the time-averaged value and the fluctuating component of radial thrust. The time-averaged value of the inertia component is nearly 0, irrespective of the change in the flow rate. However, its fluctuating component has a magnitude nearly comparable with the pressure component at a low flow rate and slightly decreased with the increase in flow rate.

회전식 수문의 중량 최소화에 대한 지지점 위치의 최적설계 (Optimal Location of Support Point for Weight Minimization in Radial Gate of Dam Structures)

  • 권영두;권순범;구남서;진승보
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.492-497
    • /
    • 2000
  • This paper focuses on the weight minimization of radial gate, as an extention of the previous work. Radial gates are commonly used to regulate the flow-rate of general purpose dams, due to its simplicity in manufacture and control. The present study identifies the optimum position of support point for 2 and 3 arm type radial gate, which guarantees the minimum weight satisfying strength constraint condition. These optimum designs are then compared with previously constructed radial gates. The results indicate that the weights of the optimized radial gates reduce by about 20%, compared to those of the conventionally designed radial gates.

  • PDF

혼돈 시계열의 예측을 위한 Radial Basis 함수 회로망 설계 (Radial basis function network design for chaotic time series prediction)

  • 신창용;김택수;최윤호;박상희
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.602-611
    • /
    • 1996
  • In this paper, radial basis function networks with two hidden layers, which employ the K-means clustering method and the hierarchical training, are proposed for improving the short-term predictability of chaotic time series. Furthermore the recursive training method of radial basis function network using the recursive modified Gram-Schmidt algorithm is proposed for the purpose. In addition, the radial basis function networks trained by the proposed training methods are compared with the X.D. He A Lapedes's model and the radial basis function network by nonrecursive training method. Through this comparison, an improved radial basis function network for predicting chaotic time series is presented. (author). 17 refs., 8 figs., 3 tabs.

  • PDF

Control of Radial Force in Double Stator Type Bearingless Switched Reluctance Motor

  • Peng, Wei;Xu, Zhenyao;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.766-772
    • /
    • 2013
  • Modeling and control of radial force in the double stator type bearingless switched reluctance motor (BLSRM) is researched. The rotational torque is controlled independently from the radial force control. And the radial force is constant which is independent from the rotor position. In order to realize steady suspension, analytical models of torque and radial force for the proposed structure are derived. Meanwhile, in order to realize steady suspension, control scheme for proposed BLSRM is proposed. In the control method, the radial force can be controlled in arbitrary direction and magnitude by selecting some combinations of radial force windings. The validities of structure and control method are verified by the experimental results.