• Title/Summary/Keyword: r-closure

Search Result 209, Processing Time 0.023 seconds

A study of Fatigue Crack Growth Behavior and Crack Closure in 5083-O Aluminum Alloy (5083-0 알루미늄合金의 疲勞균열進展 擧動과 균열닫힘에 관한 硏究)

  • 박영조;김정규;김일현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.2
    • /
    • pp.208-214
    • /
    • 1986
  • To establish the evaluation of the fatigue crack growth behavior in 5083-O aluminum alloy, constant load-amplitude fatigue crack growth tests were carried out under the small scale yielding conditions. Crack length and closure of this material were measured by the compliance method using a clip-on gage. The main results obtained as follows: The fatigue crack growth rate against stress intensity factor range .DELTA.K exhibits the trilinear form with two transitions at the growth rate 5.5*10$^{-6}$ and 5.5*10$^{-5}$ mm/cycle, in the so-caled Region II. The trilinear form appears still in the plot of growth rate versus effective stress intensity factor range .DELTA. $K_{eff}$. Stress ratio R affects the relationship of crack growth rates versus .DELTA.K but does not affect the reation of crack growth rate versus .DELTA. $K_{eff}$. The experimental results indicate that the effective stress intensity range ratio U depends on the maximum stress intensity factor $K_{max}$, but not on the stress ratio R.o R.R.

Corrosion Fatigue Cracking of Low Alloy Steel in High Temperature Water

  • Lee, S.G.;Kim, I.S.;Jang, C.H.;Jeong, I.S.
    • Corrosion Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.93-97
    • /
    • 2003
  • Fatigue crack growth test or low alloy steel was performed in high temperature water. Test parameters were dissolved oxygen content. loading frequency and R-ratio ($P_{min}/P_{max}$). Since the sulfur content or the steel was low, there were no environmentally assisted cracks (EAC) in low dissolved oxygen(DO) water. At high DO, the crack growth rate at R = 0.5 tests was much increased due to environmental effects and the crack growth rate depended on loading frequency and maximized at a critical frequency. On the other hand, R = 0.7 test results showed an anomalous decrease of the crack growth rate as much different behavior from the R = 0.5. The main reason of the decrease may be related to the crack tip closure effect. All the data could be qualitatively understood by effects of oxide rupture and anion activity at crack tip.

Examination of Effectiveness of Existing Wound Dressings (현재 사용 중인 상처도포제의 유효성 검정)

  • Lee, Kyu Hwa;Lee, Yong-Hwan;Song, Hyeon-Seong;Lee, Joung Goo;Yoo, Jaeryong;Ahn, Saekyul
    • Journal of Korean Society of Forest Science
    • /
    • v.105 no.4
    • /
    • pp.505-509
    • /
    • 2016
  • This study was conducted to examine the effectiveness of various dressing materials applied to tree wounds in Korea. Significantly higher wound closure rates than those of controls were found when thiophanatemethyl paste (Topsin Paste$^{(R)}$) was applied to Ginkgo biloba, Zelkova serrata, and Prunus yedoensis; lanolin to Z. serrata and P. yedoensis; and tebuconazole paste (Silvacur$^{(R)}$) to P. yedoensis. However, significantly lower wound closure rates than those of controls were found when petroleum jelly (Vaseline$^{(R)}$) was applied to G. biloba, Z. serrata, and P. yedoensis. It was noted that the wounds of Z. serrata and P. yedoensis treated with petroleum jelly expanded due to the death of cambium located at the edge of the wounds. Wound closure rates applied with adhesive - non-toxic to human body (Okong bond$^{(R)}$) were also significantly lower than those of controls in Z. serrata. Pinus densiflora showed no reaction to any experimental wound dressing because of resin secreted from the exposed cambium.

FE Analysis for the Prediction of Void Closure on the Free Forging Process of a Large Rotor (대형 로터의 자유단조공정에서 기공압착 예측을 위한 유한요소해석)

  • Lee, K.J.;Bae, W.B.;Kim, D.K.;Kim, Y.D.;Cho, J.R.
    • Transactions of Materials Processing
    • /
    • v.16 no.2 s.92
    • /
    • pp.126-131
    • /
    • 2007
  • Voids in a large rotor are formed in solidification process of a cast ingot. The voids have to be eliminated from the rotor by a forming process, because they would became stress-intensity factors which suddenly fracture the rotor in the operation. Previous studies on void-elimination of a large rotor have mainly focused on finding the process variables affecting the void-closure. But the study on the amount of void closure in a large rotor has been very rare. This study was performed to obtain an equation which predicts the amount of void-closure in a forging process of a large rotor and to evaluate the availability of the void-closure equation through finite element analyses. Firstly, 2D FE analysis was carried out to find effects of time integral of hydrostatic stress and effective strain on void volume rate of a large rotor in the upsetting process for various diameters and shapes of void, and material temperature. From the 2D FE analysis, we found that effective strain was suitable for predicting the void-closure of a large rotor, because there was a constant relationship between void volume rate and effective strain. And a void-closure equation was proposed fur predicting void-closure of a large rotor in the upsetting process. Finally, ken the 3D FE analysis, the proposed void-closure equation was verified to be useful for upsetting and cogging processes.

Detection and non-propagating cracks of small fatigue crack (미소피로균열의 검출과 정류균열)

  • 이종형
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.603-609
    • /
    • 1990
  • Detection and non-propagating cracks of small fatigue crack for smooth and pre-cracked specimens were examined in a carbon steel. The fretting oxide induced crack closure triggered by the roughness induced crack closure has an important role in determing the length. The fatigue limit for the with no cracks or with a short pre-crack is lower at R=-1 than that at R=0. A non-propagating crack are quite different between points near the specimen's surface and those of deepest penetration.

Acceleration of Integra Incorporation in Reconstruction of Burn Scar Contracture with The Vacuum-Assisted Closure(VAC) (Integra®를 이용한 화상 반흔 구축 재건에 있어 Vacuum-Assisted Closure(VAC)의 유용성)

  • Oh, Suk Joon;Jeon, Man Kyung;Ko, Sung Hoon
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.432-436
    • /
    • 2009
  • Purpose: Negative pressure therapy has been used in various conditions to promote wound healing. It has also been used to secure a skin graft by improving microcirculation and improving tight adhesion between the graft and the recipient bed. To reduce post burn scar contracture and improve aesthetical result, many types of dermal substitutes have been invented and used widely. The goal of this study was evaluate usefulness of the VAC (Kinetic concepts Inc., San Antonio, TX) in improving the take rate and time to incorporation of Integra$^{(R)}$ in reconstruction of burn scar contracture. Methods: A retrospective study was performed from October, 2006 to December, 2008. The VAC was utilized for 11 patients. The average patient's age was 19.7 years (range 5 - 27) and average surface area was $785cm^2$ (range 24 - 1600). The burn scars were excised deep into normal subcutaneous tissue to achieve complete release of the scar, Integra$^{(R)}$ was sutured in place with skin staple와 Steri - strip$^{(R)}$. Then slit incisions were made on silicone sheet only with No.11 blade for effective drainage. The VAC was used as a bolster dressing over Integra$^{(R)}$. Negative - Pressure ranging from 100 to 125 mm Hg was applied to black polyurethane foam sponge trimmed to the appropriate wound size. An occlusive seal over the black polyurethane foam sponge was maintained by a combination of the occlusive dressing, OP - site$^{(R)}$. The VAC dressing changes were performed every 3 or 4 days until adequate incorporation was obtained. The neodermis appeared slightly yellow to orange color. When the Integra$^{(R)}$ deemed clinically incorporated, The VAC was removed and take was estimated with visual inspection. Very thin STSG(0.006 ~ 0.008 inches) was performed after silicone sheet removal. Result: The mean time for clinically assessed incorporation of Integra$^{(R)}$ was 10.00 days (range 9 - 12). The mean dressing change was 3.5 times until take was obtained. In All patients, Integra$^{(R)}$ had successful incorporation in tissue without serious complications. Conclusion: Integra$^{(R)}$ in combination with Vacuum - Assisted Closure(VAC) may be incorporated earlier than conventional dressing method.

Glottic Closure Reflex in an Anesthetized and Awake Canine Model (개의 성문폐쇄반사에 미치는 중추조절의 영향에 관한 연구)

  • 강주완;김광문;김영호
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.14 no.2
    • /
    • pp.83-87
    • /
    • 2003
  • Background and Objectives : Sphincteric function of the larynx, essential to lower airway protection, is most efficiently achieved through strong reflex adduction by both vocal cords. We hypothesize that central facilitation is an essential component of a bilateral adductor reflex and that its disturbance could result in weakened sphincteric closure. Materials and Method : Seven adult 20kg dogs underwent evoked response laryngeal electromyoraphy under 0.5 to 1.0 MAC isoflurane anesthesia. The internal branch of superior laryngeal nerve was stimulated through bipolar platinum-iridium electrodes and recording electrodes were positioned in the ipsilateral and contralateral thyroaryteonoid muscles. Results : Consistent threshold responses were obtained ipsilaterally under all anesthetic levels. However, contralateral reflex responses disappeared as anesthetic levels approached 1.0 MAC. Additionally, at 0.5 MAC, late responses (R2) were detected in one animal. Conclusion : Alteration of central facilitation by deepening anesthesia abolishes the crossed adductor reflex, predisposing to a weakened glottic closure response. Precise understanding of this effect may improve the prevention of aspiration in patients emerging from prolonged sedation or under heavy psychotropic control.

  • PDF

A Study on Physically small Surface Fatigue Crack Growth Behavior in 7075-T651 Aluminum Alloy (7075-T651 AI 합금에 있어서 물리적 미소 표면 피로균열 성장거동에 관한 연구)

  • Sin, Yong-Seung;Seo, Seong-Won;Yu, Heon-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.1
    • /
    • pp.106-117
    • /
    • 1992
  • In this study, the propagation behaviour and the closure phenomena of physically small surface cracks were investigated by the techinque of the Kikukawa-unloading elastic compliance method using a back face strain gage. The surface cracks initiated and propagated from notched specimens under constant amplitude bending load. The crack shape (aspect ratio) with approximately semi-circular at the early stage was changed to semi-elliptical as the cracks grew larger. The crack depth (a) could be expressed uniquenly by the crack length (c). The dependence of the crack propagation rate on the stress ratio R was strongly related in the lower ${\Delta}K$ range. The deceleration of the surface crack propagation rate was prominent in lower R during the crack length was small. When the propagation rate was rearranged with the effective stress intensity factor range ${\Delta}$K_{eff} the dependence of the crack propagation rate on the stress ratio R was found to be diminshed. These were caused by the crack closure phenomena that was most prominent at the lower propagation rate. The mechanism of crack closure phenomena was dominated by the plasticity-induced mechanism.

  • PDF

Delayed closure effect in preterm infants with patent ductus arteriosus (미숙아 동맥관개존증의 지연된 폐쇄가 예후에 미치는 영향)

  • Lee, Hyun Ju;Sim, Gyu Hong;Jung, Kyung Eun;Lee, Jin A;Choi, Chang Won;Kim, Ee Kyung;Kim, Han Suk;Kim, Beyong Il;Choi, Jung-Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.10
    • /
    • pp.1065-1070
    • /
    • 2008
  • Purpose : This study aims to determine whether early closure (within 7 d) of significant patent ductus arteriosus (PDA) with indomethacin or ligation reduces neonatal morbidity when compared with delayed closure (after 7 d). Methods : Fifty-eight extremely-low-birth-weight infants admitted to the NICU of Seoul National University Hospital from April 2005 to May 2007 with PDA were studied retrospectively. Results : The mean gestational age (GA) was $26{\pm}2weeks$ (range, 23-32 wk), and the birth weight was $782{\pm}146g$ (range, 430-990 g). The delayed closure group was associated with early GA ($25.7{\pm}1.7wk$ vs $27.1{\pm}2.0wk$, P=0.013), in vitro fertilization (IVF) (55% vs 24%, P=0.017), and the absence of preeclampsia (5% vs. 34%, P=0.013). There was no difference in ductal size between the early closure and delayed closure groups. The incidence of bronchopulmonary dysplasia (95% vs 65%, P=0.012) and intraventricular hemorrhage (70% vs. 39%, P=0.027) increased in the delayed closure group. Using regression analysis adjusted for gestational age, delayed closure correlated positively with the duration of ventilator support (P=0.008), hospitalization (P=0.020), time to full enteral feeding (P<0.001), and total parenteral nutrition (P=0.010). Conclusion : Delayed closure of the hemodynamically significant patent ductus arteriosus in extremely-low-birth-weight infants is significantly related to the development of various morbidities. Thus, early closure of PDA is needed within the first week of life.

Fatigue Crack Growth Behavior in Ultrafine Grained Low Carbon Steel

  • Kim, Ho-Kyung;Park, Myung-Il;Chung, Chin-Sung;Shin, Dong-Hyuk
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.10
    • /
    • pp.1246-1252
    • /
    • 2002
  • Ultrafine grained (UFG) low carbon (0.15 wt.% C) steel produced by equal channel angula. pressing (ECAP) was tested for investigating the effect of load ratio on the fatigue crack growth rate. Fatigue crack growth resistance and threshold of UFG steel were lower than that of asreceived coarse grained steel. It was attributed to the less tortuous crack path. The UFG steel exhibited slightly higher crack growth rates and a lower △Kth with an increase of R ratio. The R ratio effect on crack growth rates and △Kth was basically indistinguishable at lower load ratio (R >0.3), compared to other alloys, which indicates that contribution of the crack closure vanishes. The crack growth rate curve for UFG steel exhibited a longer linear extension to the lower growth rate regime than that for the coarse grained as-received steel.