• Title/Summary/Keyword: r-closure

Search Result 210, Processing Time 0.024 seconds

The Foundational Study to Compare the Visual Perceptual Skill by MVPT-R in Korean and American Preschooler (MVPT-R을 이용한 한국과 미국 전학령기 아동의 시지각 능력 비교를 위한 기초 연구)

  • Park, Sung-Hyun;Park, So-Jung;Park, Soo-Hee;Jung, Hye-Rim;Chang, Moon-Young
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.3 no.1
    • /
    • pp.49-56
    • /
    • 2005
  • Objective : The purpose of this study was to indicate the foundational data to standardize MVPT-R for Koreans. Method : This study was conducted on 221 children ranging in all preschool age from 4 to 6 years residing in Busan and Kyungsangnam-do. It was performed from January 12, 2004 to April 30, 2004. Result : First, similar to American children, as Korean children grow older, the mean raw score of MVPT-R increased. Second, Korean children's mean raw score was higher than that of American children; 3.51 in 4 age, 1.52 in 4.6 age, 2.93 in 5 age, 1.72 in 5.6 age, 1.84 in 6 age and 0.48 in 6.6 age. Third, the mean of PQ(106.57) in Korean children was higher than that of PQ in American children. Fourth, The raw score in Korean children was higher than the raw score in American children in most of the subjects(excluding visual closure subjects). Conclusion : The visual perception skill of Korean children is higher than that of American children. If we apply MVPT-R developed in U.S to Korean children, it will be difficult for Korean children to achieve the adequate results. Therefore, we must use the standardized MVPT-R for Korean that can minimize the differences between American and Korean children's visual perception skills.

  • PDF

A Study on Fatigue Crack Propagation Behavior with Pure-Ti Plate (순수 티타늄 판재의 피로균열 전파거동에 관한 연구)

  • 오세욱;김태형;김득진;임만배
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.92-100
    • /
    • 1995
  • The effect of different anisotropy and stress ratio on fatigue crack propagation behavior was investigated under various stress ratio(R=-0.4, -0.2, 0.2, 0.2, 0.4) using pure titanium sheet used in aerospace, chemical and food industry. The rack closure behavior under constant load amplitude fatigue crack propagation test was examined. Fatigue crack propagation rate da/dN was estimated in terms of effective stress intensity factor range, $\Delta$K$_{eff}$, regardless of various stress ratio but was influenced by anisotropy. Also, it was found that the effect of anisotropy was considerably decreased but still not negligible when he da/dN was evaluated by a conventional parameter, $\Delta$$K_{eff}$/E and when the modified da/dN.$\sqrt{\varepsilon}_f$ was evaluated by $\Delta$$K_{eff}$/E. On the other hand, da/dN could be evaluated uniquely by effective new parameter, $\Delta$K$_{eff}$/$sigma_{ys}$, regardless of anisotropy, as int he following equation da/dN=C''[\frac{{\Delta}K_{eff}}{{\sigma}_{ys}}]^{n''}. And effective stress intensity factor range ratio, U was estimated by the following equation with respect to the ratio of reversed plastic zone size, $\Delta r_{p}$ to monotonic plastic zone size, $r_p$ regardless of stress ratio and anisotropy. U=-4.45$(\Delta r_{p}/r_{p})^{2}$+4.1$(\Delta r_{p}/r_{p})$+0.245_{p})$+0.245

  • PDF

Impact of Device Evolution in Transcatheter Closure of Patent Ductus Arteriosus Using Duct-Occlud Coils : Comparison of Mid-term Results (경피적 동맥관 폐쇄술에 사용된 Duct-Occlud Coil의 종류에 따른 중-단기 결과의 비교)

  • Kim, Myung Kwan;Han, Dong Ki;Choi, Jae Young;Kim, Yuria;Yoo, Byung Won;Choi, Deok Young;Sul, Jun Hee;Lee, Sung Kue
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.2
    • /
    • pp.158-164
    • /
    • 2005
  • Purpose : We reviewed the therapeutic results of various Duct-Occlud coils(pfm AG, $K{\ddot{o}}ln$, Germany) to evaluate the efficacy of the most-recently modified Duct-Occlud coil(Nit-Occlud) in the transcatheter closure of patent ductus arteriosus(PDA), including large defects more than 4 mm in diameter. Methods : Two hundred and five patients who underwent percutaneous PDA occlusion using Duct-Occlud devices from March 1996 to December 2003 were enrolled and four types of Duct-Occlud [Standard(S), Reinforced(R), Reinforced reverse cone(RR) and Nit-Occlud(N)] were used in this study. The patients were followed up by echocardiogram and physical examination before discharge, one month, six months and 12 months after the procedure. Results : The rate of residual shunt according to the type of Duct-Occlud were as follows : S-54%, R-72%, RR-50%, N-14%(P<0.05 compared with other devices) at one month, S-25%, R-44%, RR-37%, N-0%(P<0.05 compared with other devices) at six months, S-8%, R-8%, RR-4%, N-0%(P<0.05 compared with S and R) at 12 months and later. Nit-Occlud coil showed the complete occlusion of PDA after six months of follow-up, even in 12 patients with relatively large PDA(>4 mm). Conclusion : The transcatheter closure of PDA using Duct-Occlud was an effective treatment and our study revealed that a Nit-Occlud coil which showed higher rate of occlusion even in PDA with large diameters over than 4 mm, was a more effective modality compared to previous devices.

Clinical Use of PFA®-100 in Pre-surgical Screening for Platelet Function Test (수술 전 혈소판 기능 검사를 위한 PFA®-100의 임상적 이용)

  • Kim, Sung-Man;Yang, Seung-Bae;Lee, Jehoon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.1
    • /
    • pp.1-5
    • /
    • 2009
  • The Platelet Function Analyzer (PFA)$^{(R)}$-100 measures the ability of platelets activated in a high-shear environment to occlude an aperture in a membrane treated with collagen and epinephrine (CEPI) or collagen and ADP (CADP). The time taken for the flow across the membrane to stop (closure time, CT) is recorded. The aim of this study was to assess the potential of the PFA$^{(R)}$-100 as a primary clinical screening tool using the wide spectrum of clinical samples assessed for platelet function as well as to perform the optimal algorithm for the use of PFA$^{(R)}$-100. We established the reference interval in 460 hospital inpatients defined as having normal platelet function based on classical laboratory tests. The reference interval by using the range $5^{th}$ and $95^{th}$ percentile was 84~251 seconds for males CEPI-CT and 85~249 seconds for females CEPI-CT. A total of 1,200 inpatients were enrolled to identify impaired hemostasis before surgical interventions. The abnormal group showing prolonged CEPI-CT was 303 cases (18.9%). Only 3 cases had both abnormal CEPI-CT and CADP-CT. Several factors including sample errors, drugs, hematologic abnoralities were contributed to unexpected prolonged CEPI-CT for screening test. The von Willebrand factor (vWF:Ag) assay was performed only in one patient to verify the algorithm for the use of PFA$^{(R)}$-100. The PFA$^{(R)}$-100 was sensitive and rapid method for primary screening test of platelet dysfunction, so we can substitute it for the bleeding time in routine clinical practice.

  • PDF

A Roentgenographic Study on the Development of Roots of Mandibular Permanent Posterior Teeth (하악영구구치 치근발육에 관한 방사선학적 연구)

  • 고명연;정성창
    • Journal of Oral Medicine and Pain
    • /
    • v.6 no.1
    • /
    • pp.23-34
    • /
    • 1981
  • In order to evaluate the correlation of age with development stage on permanent lower posterior teeth. the author exmined the roentgeregrams in standard films taken by intraoral technic and analysed the development phases of 1358 teeth of 500 males ranging from 9 to 15 years. The development was divided into 7 phases : Crown complete (Cr. C.). Root length 1/4(R. 1/4) Root length /2 (R. 1/2) Apical closure complete (A.C) The obtained results were as follows : 1. The formation of roots in full length on posterior teeth was complete as follow : a. Roots of 1st premolar : 12.72 years b. Roots of 2nd premolar : 12.94 years c. Meral Roots of 2nd molar : 13.38 years d. Distal Roots of 2nd molar : 13.46 years 2. The formation of apical forman of premolar was closured as follows : a. Apical foramen of root of 1st premolar : 13.64 years b. Apical foramen of root of 2nd premolar : 13.93 years 3. As a general rule. the mesial roots of second molar were developed earlier than distal roots of second molar. 4. In the correlation of age with the development stage, the regression equations. the correlation coefficents. and the sample numbers were “Y = 0.8370x + 10.2160, r = 0.71(p<0.01), n = 318”on lower first premolar, “Y = 0.6984x + 10.2148, r = 0.71(p<0.01), n = 385”on lower second premolar, “Y = 0.8810x + 10.2040, r = 0.65(p<0.01), n = 344”on mesial Root of lower second molar, and “Y = 0.7310x + 10.7940, r = 0.66(p<0.01), n = 311”on Distal Root of lower second molar respectively.

  • PDF

A Study on the Characteristics of Fatigue Crack Growth of A516 Steel for Pressure Vessel at Low Temperatures (압력용기용 A516강의 저온피로크랙전파특성에 관한 연구)

  • Park, Kyung-Dong;Ro, Tae-Young;Kim, Young-Dae;Kim, Hyung-Ja;Son, Jae-Yun
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3 s.33
    • /
    • pp.108-113
    • /
    • 1999
  • In this study, CT specimens were prepared from ASTM A516 Gr. 65 which was used for pressure vessel plates for moderate and lower temperature service. Fatigue crack growth test was carried out in the environment of low temperature of $10^{circ}C, -10^{circ}C, -30${circ}C\;and\;-50^{circ}C$ and in the range of stress ratio of R=0.05 and 0.3 by means of opening mode displacement. Based on these test results, the characteristics from temperature and stress ration were shown as follows. 1) As the stress ratio, R increased da/dN and ${Delta}K$ of 2nd stage gradually decreased. And as R decreased, the effect of temperature became greater and greater. 2) As the temperature descended, da/dN decreased on a certain ${Delta}K$, and ${Delta}K$ did in a same da/dN. And the stress ratio, R exerted greater influence at the lower temperature. 3) The fatigue crack growth constant, m increased at $10^{circ}C$ and $-10^{circ}C$, snd decreased at $-30^{circ}C$ and $-50^{circ}C$ following the increment of stress ratio R. And m increased along with the reduction of temperature greatly decreased at $-30^{circ}C$ to come close to two(2).

  • PDF

Study on forming Process of Piston Crown Using Near Net Shaping Technology (재료이용율 향상을 위한 피스톤 크라운 성형공정 연구)

  • Choi, H.J.;Choi, S.;Yoon, D.J.;Jung, H.S.;Choi, I.J.;Baek, D.K.;Choi, S.K.;Park, Y.B.;Lim, S.J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.197-198
    • /
    • 2008
  • The forging process produces complicated and designed components in a die at high productivity for mass production and minimizes the machining amount for favorable material utilization; the forging products used at highly stressed sections are well accepted at a wide range of industry such as automobile, aerospace, electric appliance and et cetera. Accordingly, recent R&D activities have been emphasized on improvement of forging die-life and near net shaping technology for cost effectiveness and better performance. Usually closing and consolidation of internal void defects in a ingot is a vital matter when utilized as large forged products. It is important to develop cogging process for improvement of internal soundness without a void defect and cost reduction by solid forging alone with limited press capacity. For experiments of cogging process, hydraulic press with a capacity of 800 ton was used together with a small manipulator which was made for rotation and overlapping of a billet. Size of a void was categorized into two types; ${\phi}$ 6.0 mm and ${\phi}$ 9.0 mm to investigate the change of closing and consolidation of void defects existed in the large ingot during the cogging process. In addition for forming experiment of piston grown air drop hammer with a capacity of 16 ton was used. The experiment with piston crown was carried out to show the formability and void closing status. In this paper systematic configuration for closing process of void defects were expressed based on this experiment results in the cogging process. Also forging defects through forming process for piston crown was improved using the experiment results and FE analysis. Consequently this paper deals with the effect of radial parameters in cogging process on a void closure far large forged products and formability of piston crown.

  • PDF

Scalp reconstruction: A 10-year experience

  • Jang, Hyeon Uk;Choi, Young Woong
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.4
    • /
    • pp.237-243
    • /
    • 2020
  • Background: The scalp is an important functional and aesthetic structure that protects the cranial bone. Due to its inelastic characteristics, soft-tissue defects of the scalp make reconstruction surgery difficult. This study aims to provide an improved scalp reconstruction decision making algorithm for surgeons. Methods: This study examined patients who underwent scalp reconstruction within the last 10 years. The study evaluated several factors that surgeons use to select a given reconstruction method such as etiology, defect location, size, depth, and complications. An algorithmic approach was then suggested based on an analysis of these factors. Results: Ninety-four patients were selected in total and 98 cases, including revision surgery, were performed for scalp reconstruction. Scalp reconstruction was performed by primary closure (36.73%), skin graft (27.55%), local flap (17.34%), pedicled regional flap (15.30%), and free flap (3.06%). The ratio of primary closure to more complex procedure on loose scalps (51.11%) was significantly higher than on tight scalps (24.52%) (p=0.011). The choice of scalp reconstruction method was affected significantly by the defect size (R=0.479, p<0.001) and depth (p<0.001). There were five major complications which were three cases of flap necrosis and two cases of skin necrosis. Hematoma was the most common of the 29 minor complications reported, followed by skin necrosis. Conclusion: There are multiple factors affecting the choice of scalp reconstruction method. We suggest an algorithm based on 10 years of experience that will help surgeons establish successful surgical management for their patients.

The Effects of the Microstructures on the Fatigue Crack Propagation Behaviors of Cast Irons (주철의 피로전파거동에 미치는 미세조직의 영향)

  • Kim, Sug-Won;Park, Jin-Sung;Lee, Hyung-Chul;Kim, Dong-Keun;Woo, Kee-Do
    • Journal of Korea Foundry Society
    • /
    • v.25 no.1
    • /
    • pp.16-22
    • /
    • 2005
  • This study aims to investigate the effects of the microstructures and nodule type on the fatigue characteristics of cast iron. Fatigue tests were carried out in tension-tension mode using a servo-hydraulic testing machine with load control mode operating at a frequency of 15 Hz. The tests were conducted at stress ratio R=Kmin/Kmax, of 0.1. Initial crack ${\Dalta}K$ values were highly performed with increase in tensile strength of DCI fatigue specimens. ${\Dalta}K_{th}$ region, fatigue crack propagation was primarily advanced through cell boundary and in periphery of near nodule. Fatigue crack propagation rate of D2 consisted with 2Phase(Ferrite+Pearlite) was slow due to crack closure enhanced by crack deflection and occurred crack branching. The generation of crack branch was occurred due to interaction of crack-nodule. At Threshold and Paris zone, the fractographs of the fatigue fracture surface for DCI show typical striations of a ductile fracture and isolated cleavage planes near graphite. The effect of microstructure on fatigue crack propagation of GC strongly depends on the type of flake. The generation of crack branch occurred due to interaction of crack-nodule. The fractographs of the fatigue fracture surface for GC show cleavage plane along the flake graphite.

Useful and Effective Diagnosis and Evaluation Tools for Eenvironmental Change in Increased Mill Water System Closure

  • Linda R. Robertson;Lee, Byung-Tae;Kim, Tae-Joon
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.5
    • /
    • pp.1-11
    • /
    • 2001
  • In the past, abundant and clean water was available for paper mills'use. However, the growth of population and industry made water less available nowadays. Also, environmental regulation limits wastewater discharge, which affects mill operation cost. Therefore, paper mills are under pressure to use more recycled water and mill system closure. As a result, chemical and physical parameters of water are changing and new environment if being created for microorganisms in paper mill system as well. The more soluble or suspended organic materials are increased as more water is recycled and less or scarce dissolved oxygen is available, depending on the degree of recycled water usage. Microorganism flora ill paper mill system will be a1so shifted according to the environmental change of mill system. Anaerobic bacteria, including sulfate reducing bacteria (SRB), will be dominant in the system as very low or almost no oxygen available in the system. Nevertheless, it is common in domestic paper mills that employ the same and old biocides as a means of microbial control, and microbiological control is often less recognized or even neglected. The right biocide selection for increased reductive environment of mills is critical for operation and estimated loss from paper quality defects such as sheet break, holes due to microbiological cause is tremendous compared to the microbiological control cost. It is imperative to investigate and diagnosis the environmental change of mills for right control of cumbersome microorganisms. Several useful diagnosis tools, including new technology employing OFM(Optical Fouling Monitor) in situ, are illustrated.

  • PDF