• Title/Summary/Keyword: quantitative test

Search Result 2,292, Processing Time 0.034 seconds

Assessment and Analysis of Fidelity and Diversity for GAN-based Medical Image Generative Model (GAN 기반 의료영상 생성 모델에 대한 품질 및 다양성 평가 및 분석)

  • Jang, Yoojin;Yoo, Jaejun;Hong, Helen
    • Journal of the Korea Computer Graphics Society
    • /
    • v.28 no.2
    • /
    • pp.11-19
    • /
    • 2022
  • Recently, various researches on medical image generation have been suggested, and it becomes crucial to accurately evaluate the quality and diversity of the generated medical images. For this purpose, the expert's visual turing test, feature distribution visualization, and quantitative evaluation through IS and FID are evaluated. However, there are few methods for quantitatively evaluating medical images in terms of fidelity and diversity. In this paper, images are generated by learning a chest CT dataset of non-small cell lung cancer patients through DCGAN and PGGAN generative models, and the performance of the two generative models are evaluated in terms of fidelity and diversity. The performance is quantitatively evaluated through IS and FID, which are one-dimensional score-based evaluation methods, and Precision and Recall, Improved Precision and Recall, which are two-dimensional score-based evaluation methods, and the characteristics and limitations of each evaluation method are also analyzed in medical imaging.

Study on the Application of Artificial Intelligence Model for CT Quality Control (CT 정도관리를 위한 인공지능 모델 적용에 관한 연구)

  • Ho Seong Hwang;Dong Hyun Kim;Ho Chul Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.182-189
    • /
    • 2023
  • CT is a medical device that acquires medical images based on Attenuation coefficient of human organs related to X-rays. In addition, using this theory, it can acquire sagittal and coronal planes and 3D images of the human body. Then, CT is essential device for universal diagnostic test. But Exposure of CT scan is so high that it is regulated and managed with special medical equipment. As the special medical equipment, CT must implement quality control. In detail of quality control, Spatial resolution of existing phantom imaging tests, Contrast resolution and clinical image evaluation are qualitative tests. These tests are not objective, so the reliability of the CT undermine trust. Therefore, by applying an artificial intelligence classification model, we wanted to confirm the possibility of quantitative evaluation of the qualitative evaluation part of the phantom test. We used intelligence classification models (VGG19, DenseNet201, EfficientNet B2, inception_resnet_v2, ResNet50V2, and Xception). And the fine-tuning process used for learning was additionally performed. As a result, in all classification models, the accuracy of spatial resolution was 0.9562 or higher, the precision was 0.9535, the recall was 1, the loss value was 0.1774, and the learning time was from a maximum of 14 minutes to a minimum of 8 minutes and 10 seconds. Through the experimental results, it was concluded that the artificial intelligence model can be applied to CT implements quality control in spatial resolution and contrast resolution.

Cone-beam computed tomography texture analysis can help differentiate odontogenic and non-odontogenic maxillary sinusitis

  • Andre Luiz Ferreira Costa;Karolina Aparecida Castilho Fardim;Isabela Teixeira Ribeiro;Maria Aparecida Neves Jardini;Paulo Henrique Braz-Silva;Kaan Orhan;Sergio Lucio Pereira de Castro Lopes
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.43-51
    • /
    • 2023
  • Purpose: This study aimed to assess texture analysis(TA) of cone-beam computed tomography (CBCT) images as a quantitative tool for the differential diagnosis of odontogenic and non-odontogenic maxillary sinusitis(OS and NOS, respectively). Materials and Methods: CBCT images of 40 patients diagnosed with OS (N=20) and NOS (N=20) were evaluated. The gray level co-occurrence (GLCM) matrix parameters, and gray level run length matrix texture (GLRLM) parameters were extracted using manually placed regions of interest on lesion images. Seven texture parameters were calculated using GLCM and 4 parameters using GLRLM. The Mann-Whitney test was used for comparisons between the groups, and the Levene test was performed to confirm the homogeneity of variance (α=5%). Results: The results showed statistically significant differences(P<0.05) between the OS and NOS patients regarding 3 TA parameters. NOS patients presented higher values for contrast, while OS patients presented higher values for correlation and inverse difference moment. Greater textural homogeneity was observed in the OS patients than in the NOS patients, with statistically significant differences in standard deviations between the groups for correlation, sum of squares, sum of entropy, and entropy. Conclusion: TA enabled quantitative differentiation between OS and NOS on CBCT images by using the parameters of contrast, correlation, and inverse difference moment.

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF

Quantification of Bacillus Species in a Wastewater Treatment System by the Molecular Analyses

  • Mori Koji;Iriye Ryozo;Hirata Mutsunori;Takamizawa Kazuhiro
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.6
    • /
    • pp.482-489
    • /
    • 2004
  • Bacillus species were observed and quantified by molecular approaches, using the 16S rDNA primers/probes, in a wastewater treatment plant designed for the purpose of stimulating the growth of Bacillus species. The plant has been operating as a test plant since 1997 in the city of Ina, Japan, with excellent treatment performance. Observations by in situ hybridization, using Bacillus-specific probes, indicated that Bacillus strains were inhabited in the plant and their num­bers decreased during the treatment process. Similar results were obtained from a quantitative PCR analysis using a Bacillus-specific primer set, and the amount of DNA originating from various Bacillus species was maximally $1.91%\$ of the total DNA in the wastewater treatment tank. Clone library analysis using the Bacillus-specific primers suggested that, while the population was no­ticeably increased, the phylogenetic diversity of the increasing Bacillus species was very low.

Network Intrusion Detection Based on Directed Acyclic Graph and Belief Rule Base

  • Zhang, Bang-Cheng;Hu, Guan-Yu;Zhou, Zhi-Jie;Zhang, You-Min;Qiao, Pei-Li;Chang, Lei-Lei
    • ETRI Journal
    • /
    • v.39 no.4
    • /
    • pp.592-604
    • /
    • 2017
  • Intrusion detection is very important for network situation awareness. While a few methods have been proposed to detect network intrusion, they cannot directly and effectively utilize semi-quantitative information consisting of expert knowledge and quantitative data. Hence, this paper proposes a new detection model based on a directed acyclic graph (DAG) and a belief rule base (BRB). In the proposed model, called DAG-BRB, the DAG is employed to construct a multi-layered BRB model that can avoid explosion of combinations of rule number because of a large number of types of intrusion. To obtain the optimal parameters of the DAG-BRB model, an improved constraint covariance matrix adaption evolution strategy (CMA-ES) is developed that can effectively solve the constraint problem in the BRB. A case study was used to test the efficiency of the proposed DAG-BRB. The results showed that compared with other detection models, the DAG-BRB model has a higher detection rate and can be used in real networks.

Identification of Superior Polyvoltine Hybrids (polyvoltine${\times}$bivoltine) of Silkworm, Bombyx mori L.

  • Rao, C.G.P.;Chandrashekharaiah;Basha, K.Ibrahim;Seshagiri, S.V.;Ramesh, C.;Nagaraju, H.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.8 no.1
    • /
    • pp.43-49
    • /
    • 2004
  • Ten promising polyvoltine mulberry silkworm strains(SDMGl, SDMG2, SDMG3, SDMG4, SDMWl, SDMW2, RMWl, RMW2, RMW3 and RMW4) that are superior in quantitative and qualitative traits have been synthesized in the polyvoltine breeding laboratory of Andhra Pradesh State Sericulture Research & Development Institute, Hindupur through systematic hybridization and appropriate selection methods. After the genotypes were found homozygous for the desired traits, they have been crossed with 3 bivoltine testers $(APS8, APS4 and {NB_2}{D_4})$ and thirty new hybrid combinations were developed for the assessment of their hybrid performance. Phenotypic expressions of economically important quantitative and qualitative traits of fist filial generation were measured and subjected for statistical analysis. Evaluation Index and Subordinate Function methods were employed for the assessment of hybrid performance since they are widely used in silkworm hybrid evaluation. Total of seven poly${\times}$bivoltine combinations, which ranked high in both the methods, were selected as potential combinations for further field test. These combinations also ranked significantly higher than the control hybrid (APMl${\times}$APS8).

Changes in Clinical Practice Environment of Nursing Students due to Comprehensive Nursing Care Services (간호·간병통합서비스로 인한 간호대학생 임상실습환경의 변화)

  • Kim, Jeonghyun;Shin, Sujin;Lee, Minkyung
    • Journal of Korean Public Health Nursing
    • /
    • v.32 no.2
    • /
    • pp.221-234
    • /
    • 2018
  • Purpose: This mixed method study was conducted to analyze the changes in nursing students' practice environment due to comprehensive nursing care services. Methods: For the quantitative study, a checklist and practicum evaluation surveys completed by 85 students were analyzed using SPSS utilizing a Mann-Whitney U test. For the qualitative study, 13 students with experience of practice in comprehensive nursing care service units participated in focus group interviews. The data were analyzed using a content analysis method. Results: From the qualitative findings, four themes and eight sub-themes were identified. The four themes were , , , and . The quantitative findings found that students could observe and perform fewer nursing tasks and the students' satisfaction with practice was lower in the comprehensive nursing care service unit. Conclusion: This study was meaningful in that it analyzed the experiences of nursing students in comprehensive nursing care services.

An Improved Scheme of Evaluation Process in the Advanced Construction Technology Endorsement System (건설신기술 지정제도의 평가프로세스 개선방안)

  • Tae Yong-Ho;Park Chan-Sik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.363-366
    • /
    • 2002
  • The advanced construction technology endorsement system(ACTES) has used the improper evaluation criteria. Because of its insufficiency of quantitative evaluation, it is difficult to attain the objective and fairness. This study used a survey to investigate a actual condition of ACTES. The survey found that ACTES needed a evaluation criteria and a quantitative evaluation method. In addition, This study proposes the evaluation model that uses a discriminant function. The model process consists of several phases that are brain storming, t-test and discriminant function analysis.

  • PDF

Use Studies of Library Collections (장서평가에 관한 소고 -특히 이용조사를 중심으로-)

  • Yoo Chae-Ock
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.15
    • /
    • pp.175-195
    • /
    • 1988
  • Use studies of library collections have been conducted as a method of evaluating collections in a library. The main purpose of use studies is to evaluate the quality of a library collection in terms of extent and mode of its use. In addition to use studies, both quantitative and qualitative methods could be utilized in order to evaluate a library collection. However, the quantitative and qualitative collection evaluation methods are more concerned with the collection itself than with its use. Use studies have been conducted in large academic libraries for the following specific purposes: 1) They attempt to identify little used portion of collections that can be retired less accessible and less expensive storage area. 2) They try to identify core collections to satisfy some degree of circulation demands in the near future. 3) They try to identify use patterns of selected subject areas or type of books that can be used to adjusting collection development practices or fund allocations. 4) They try to assess the document delivery capability of a library to improve their availability. A number of methodologies employed for these specific purposes fall into four major categories; 1) circulation analysis method, 2) last circulation method, 3) relative use method, and 4) document delivery test. Each method is briefly reviewed with its limitations.

  • PDF