• Title/Summary/Keyword: quantitative test

Search Result 2,292, Processing Time 0.043 seconds

Evaluations of corrosion resistance of Ni-Cr plated and Zn-plated Fe Substrates Using an Electrolytic Corrosion Test (전해부식시험을 이용한 니켈-크롬도금강판 및 아연도금강판의 내식성 비교평가시험)

  • Lee, Jae-Bong;Kim, Kyung-Wook;Park, Min-Woo;Song, Tae-Jun;Lee, Chae-Seung;Lee, Eui-Jong;Kim, Sang-Yeol
    • Corrosion Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.56-64
    • /
    • 2013
  • An Eectrolytic Corrosion(EC) test method was evaluated by the comparison with Copper Accelerated Acetic Salt Spray(CASS) and Neutral Salt Spray(SS) tests. Those methods were applied in order to evaluate corrosion resistance of Ni-Cr plated and Zn-plated Fe substrates. The correlations between results obtained by different test methods were investigated. Results showed that the electrochemical method such as the EC test method was superior to the conventional methods such as CASS and SS, in terms of the quantitative accuracy and the test-time span. Furthermore, the EC test method provided the useful means to estimate the initiation of corrosion of each layer by monitoring the rest potentials of the coated layers such as Ni, Cr, and Zn on Fe substrate. With regard to test time spans, the EC test provided the 78 times and 182 times faster results than the CASS test in cases of $Fe+5{\mu}m$ $Ni+0.5{\mu}m$ Cr and $Fe+20{\mu}m$ $Ni+0.5{\mu}m$ Cr respectively, while the EC test was 85 times faster results than the Salt Spray test in the case of $Fe+20g/m^2$ Zn. Therefore, the EC test can be the better method to evaluate the resistance to corrosion of coated layers than the conventional methods such as the SS test and the CASS.

Concurrent Validity and Test-retest Reliability of the Core Stability Test Using Ultrasound Imaging and Electromyography Measurements

  • Yoo, Seungju;Lee, Nam-Gi;Park, Chanhee;You, Joshua (Sung) Hyun
    • Physical Therapy Korea
    • /
    • v.28 no.3
    • /
    • pp.186-193
    • /
    • 2021
  • Background: While the formal test has been used to provide a quantitative measurement of core stability, studies have reported inconsistent results regarding its test-retest and intraobserver reliabilities. Furthermore, the validity of the formal test has never been established. Objects: This study aimed to establish the concurrent validity and test-retest reliability of the formal test. Methods: Twenty-two young adults with and without core instability (23.1 ± 2.0 years) were recruited. Concurrent validity was determined by comparing the muscle thickness changes of the external oblique, internal oblique, and transverse abdominal muscle to changes in core stability pressure during the formal test using ultrasound (US) imaging and pressure biofeedback, respectively. For the test-retest reliability, muscle thickness and pressure changes were repeatedly measured approximately 24 hours apart. Electromyography (EMG) was used to monitor trunk muscle activity during the formal test. Results: The Pearson's correlation analysis showed an excellent correlation between transverse abdominal thickness and pressure biofeedback unit (PBU) pressure as well as internal oblique thickness and PBU pressure, ranging from r = 0.856-0.980, p < 0.05. The test-retest reliability was good, intraclass correlation coefficient (ICC1,2) = 0.876 for the core stability pressure measure and ICC1,2 = 0.939 to 0.989 for the abdominal muscle thickness measure. Conclusion: Our results provide clinical evidence that the formal test is valid and reliable, when concurrently incorporated into EMG and US measurements.

Sensory properties of oriental melon (Cucumis melo var. makuwa) byquantitative descriptive analysis and consumer test (묘사분석 및 소비자 조사에 의한 참외의 관능특성)

  • Kim, Sang Seop;Choi, Eun Jeong;Choi, Jeong Hee;Ku, Kyung Hyung
    • Food Science and Preservation
    • /
    • v.23 no.5
    • /
    • pp.727-737
    • /
    • 2016
  • This study was carried out to determine the descriptive sensory profile of oriental melon. The sensory profile of oriental melons (cultivated in Seonju, Kyungsangbuk-do) were used quantitative descriptive analyses and twelve trained panel developed the total forty sensory attributes related appearance, aroma, texture etc. Six appearances attributes and two aromas attributes were derived from whole oriental melon with skin. Five aromas, six tastes and six textures were derived from the mesocarp of oriental melon. And also, oriental melons were analyzed for pH, titratable acidity, solid soluble contents and weight. The weight, titratable acidity and soluble solid content of oriental melons showed significant differences according to samples. And also, in the sensory attributes of these samples by trained panel and consumer test, there were significant differences between organic cultivated samples and conventional cultivated samples. Based on principal component analysis of sensory attributes data by trained panel and consumer, oriental melons were primary separated along the first principal component, which accounted for 27.73% (trained panel test) and 19.82% (consumer test) of total variance (trained panel test; 58.36%, consumer test; 46.18%) between the samples farm, cultivation method, total acidity, sweet aroma, bitterness, etc. Generally, whole oriental melon with skin showed significant differences in the sensory attributes according to cultivation method and farms. But, the mesocarp and endocarp part showed not certainly differences in the sensory attributes between organic cultivated samples except conventional cultivated samples.

Investigation of thermal hydraulic behavior of the High Temperature Test Facility's lower plenum via large eddy simulation

  • Hyeongi Moon ;Sujong Yoon;Mauricio Tano-Retamale ;Aaron Epiney ;Minseop Song;Jae-Ho Jeong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3874-3897
    • /
    • 2023
  • A high-fidelity computational fluid dynamics (CFD) analysis was performed using the Large Eddy Simulation (LES) model for the lower plenum of the High-Temperature Test Facility (HTTF), a ¼ scale test facility of the modular high temperature gas-cooled reactor (MHTGR) managed by Oregon State University. In most next-generation nuclear reactors, thermal stress due to thermal striping is one of the risks to be curiously considered. This is also true for HTGRs, especially since the exhaust helium gas temperature is high. In order to evaluate these risks and performance, organizations in the United States led by the OECD NEA are conducting a thermal hydraulic code benchmark for HTGR, and the test facility used for this benchmark is HTTF. HTTF can perform experiments in both normal and accident situations and provide high-quality experimental data. However, it is difficult to provide sufficient data for benchmarking through experiments, and there is a problem with the reliability of CFD analysis results based on Reynolds-averaged Navier-Stokes to analyze thermal hydraulic behavior without verification. To solve this problem, high-fidelity 3-D CFD analysis was performed using the LES model for HTTF. It was also verified that the LES model can properly simulate this jet mixing phenomenon via a unit cell test that provides experimental information. As a result of CFD analysis, the lower the dependency of the sub-grid scale model, the closer to the actual analysis result. In the case of unit cell test CFD analysis and HTTF CFD analysis, the volume-averaged sub-grid scale model dependency was calculated to be 13.0% and 9.16%, respectively. As a result of HTTF analysis, quantitative data of the fluid inside the HTTF lower plenum was provided in this paper. As a result of qualitative analysis, the temperature was highest at the center of the lower plenum, while the temperature fluctuation was highest near the edge of the lower plenum wall. The power spectral density of temperature was analyzed via fast Fourier transform (FFT) for specific points on the center and side of the lower plenum. FFT results did not reveal specific frequency-dominant temperature fluctuations in the center part. It was confirmed that the temperature power spectral density (PSD) at the top increased from the center to the wake. The vortex was visualized using the well-known scalar Q-criterion, and as a result, the closer to the outlet duct, the greater the influence of the mainstream, so that the inflow jet vortex was dissipated and mixed at the top of the lower plenum. Additionally, FFT analysis was performed on the support structure near the corner of the lower plenum with large temperature fluctuations, and as a result, it was confirmed that the temperature fluctuation of the flow did not have a significant effect near the corner wall. In addition, the vortices generated from the lower plenum to the outlet duct were identified in this paper. It is considered that the quantitative and qualitative results presented in this paper will serve as reference data for the benchmark.

Application of Corrosion Inhibitors to Protect the Corrosion of Reinforcement in Concrete (콘크리트 중의 철근방식을 위한 방청제의 적용)

  • 문한영;김성수;김홍삼;안기용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.751-754
    • /
    • 1999
  • Corrosion inhibitors are widely used to protect chloride-induced corrosion of reinforcement in concrete. However, the number of researches on the corrosion of reinforcement, when corrosion inhibitor is used, is not enough for actual application in the field. In addition, on corrosion of reinforcement a quantitative standard about corrosion inhibitor does not exist and the data about its influencing concrete are relatively rare. In this study, the effectiveness of rebar corrosion protection, setting time, compressive strength, chloride ion's penetration, and diffusion test were performed using with three different kinds of corrosion inhibitors.

  • PDF

A Major DNA Marker Mining of microsatellite loci in Hanwoo Chromosome 17

  • Lee, Yong-Won;Lee, Je-Yeong
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.54-58
    • /
    • 2005
  • 한우 17번 염색체 유전자 지도에서 QTL (quantitative trait loci) 분석을 실시하여 선별된 Loci 값들을 순열검정(Permutation Test)을 이용하여 유의성 검정을 실시하였다. 한편, 우수 경제형질 DNA marker들을 K-평균 군집법을 실시 파악하였다. 또한, 부스트랩 방법을 이용하여 선별된 Locus의 DNA Marker들의 신뢰구간을 구하였다. 이들 QTL과 K-평균법, 부스트랩 방법에 의해 한우의 염색체 17번 BMS941의 우수 DNA Marker 85, 105번을 선별하였다.

  • PDF

Quantitative characteristics of particle size distribution by the wear mode transition (마모유형 천이에 따른 입자크기분포의 정량적 특성)

  • 공호성;권오관
    • Tribology and Lubricants
    • /
    • v.2 no.1
    • /
    • pp.39-45
    • /
    • 1986
  • Wear simulation test have been conducted in mild, severe and transient wear regions by a four-ball wear tester. Wear particles are separatively deposited by the RPD technique, and quantitatively analysed in terms of wear particles size distribution. Characteristics of the wear particle size distribution are compare to the results of wear tests through both weibull parameters and center moment method of the weibull distribution function.

A Model and Simulated Annealing Algorithm for the Multi-factor Plant Layout Problem (다수요인을 가진 설비배치문제를 위한 모형과 simulated annealing 알고리즘)

  • 홍관수
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.20 no.1
    • /
    • pp.63-81
    • /
    • 1995
  • This paper presents a model and algorithm for solving the multi-factor plant layout problem. The model can incorporate more than two factors that may be either quantitative or qualitative. The algorithm is based on simulated annealing, which has been successfully applied for the solution of combinatorial problems. A set of problems previously used by various authors is solved to demonstrate the effectiveness of the proposed methods. The results indicate that the proposed methods can yield good quality for each of eleven test problems.

  • PDF

A Study on the Quantitative Human Visual Preference with PDP and LCD

  • Lee, Hwal-Ly;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1143-1146
    • /
    • 2007
  • We carried out the human visual evaluation on PDPs and LCDs to clarify the viewer preference and the related physical and physiological factors. In the subjective evaluation, the impression test using the semantic differential method was carried out. In the objective evaluation, the eye motion tracking system was used. Our study showed that considering the real usage, the optimum display for viewers was that which showed more soft and smooth image without blurring.

  • PDF

순열검정과 부스트랩 방법에 의한 한우 6번 염색체의 ILSTS035에 대한 우수 DNA Marker 선별

  • Lee, Yong-Won;Lee, Je-Yeong;Kim, Mun-Jeong;Han, Cho-Hui
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2003.10a
    • /
    • pp.325-329
    • /
    • 2003
  • 한우 6번 염색체 유전자 지도에서 QTL (quantitative trait loci) 분석을 실시하여 선별된Locus 값을 순열검정(Permutation Test)을 이용하여 유의성 검정을 실시하였다. 한편, 우수경제형질 DNA marker들을 K-평균 군집법을 실시 파악하였다. 이들 QTL과 K-평균법에 의해 한우의 염색체 6번 ILSTS035의 우수 DNA marker 235번을 선별하였다. 선별된 DNA Marker 235번을 출품우에 적용하여 Bootstrap 방법을 이용하여 신뢰구간을 구하여 검정하였다.

  • PDF