• Title/Summary/Keyword: quantitative test

Search Result 2,292, Processing Time 0.031 seconds

Development and Evaluation of the Life Respect Enhancement Program for Nursing Officers (간호장교를 대상으로 한 생명존중 역량강화 프로그램 개발과 평가)

  • Hwang, Sunyoung;Choi, Heeseung
    • Journal of Korean Academy of Nursing
    • /
    • v.50 no.4
    • /
    • pp.599-610
    • /
    • 2020
  • Purpose: The present study was conducted to develop the Life Respect Enhancement Program and test its effectiveness on suicide knowledge, suicide intervention skills, self-efficacy in suicide prevention, and gatekeeper behaviors among nursing officers. Methods: The program was developed according to the ADDIE model and finalized after practical need analysis, expert verification, and a preliminary study. The present study used a concurrent embedded mixed-method research design. To compare the effects of the Program and the control group on the outcome variables, a quantitative study was conducted using a nonequivalent control group with a pretest-posttest design. Quantitative data were analyzed using χ2-tests, t-tests, and RM-ANOVA. A qualitative study was conducted using FGI with six members of the experimental group 3 months after intervention completion. Results: In total, 56 nursing officers participated in the 3-month follow-up test. Compared to the control group, the experimental group showed significant improvements in suicide knowledge, suicide intervention skills, and self-efficacy in suicide prevention scores at post-test. The significant group differences in suicide knowledge and suicide intervention skills were maintained at 3 months. The gatekeeper behavior scores of the experimental group were also significantly higher than those of the control group at 3 months. Qualitative analysis of the participants' experiences with the Program yielded two themes and seven sub-themes. Conclusion: The newly developed Life Respect Enhancement Program demonstrates significant effects on suicide knowledge, suicide intervention skills, and gatekeeper behaviors. Thus, this program is recommended to promote suicide prevention competencies among nursing officers in military clinical settings.

Designing Hypothesis of 2-Substituted-N-[4-(1-methyl-4,5-diphenyl-1H-imidazole-2-yl)phenyl] Acetamide Analogs as Anticancer Agents: QSAR Approach

  • Bedadurge, Ajay B.;Shaikh, Anwar R.
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.6
    • /
    • pp.744-754
    • /
    • 2013
  • Quantitative structure-activity relationship (QSAR) analysis for recently synthesized imidazole-(benz)azole and imidazole - piperazine derivatives was studied for their anticancer activities against breast (MCF-7) cell lines. The statistically significant 2D-QSAR models ($r^2=0.8901$; $q^2=0.8130$; F test = 36.4635; $r^2$ se = 0.1696; $q^2$ se = 0.12212; pred_$r^2=0.4229$; pred_$r^2$ se = 0.4606 and $r^2=0.8763$; $q^2=0.7617$; F test = 31.8737; $r^2$ se = 0.1951; $q^2$ se = 0.2708; pred_$r^2=0.4386$; pred_$r^2$ se = 0.3950) were developed using molecular design suite (VLifeMDS 4.2). The study was performed with 18 compounds (data set) using random selection and manual selection methods used for the division of the data set into training and test set. Multiple linear regression (MLR) methodology with stepwise (SW) forward-backward variable selection method was used for building the QSAR models. The results of the 2D-QSAR models were further compared with 3D-QSAR models generated by kNN-MFA, (k-Nearest Neighbor Molecular Field Analysis) investigating the substitutional requirements for the favorable anticancer activity. The results derived may be useful in further designing novel imidazole-(benz)azole and imidazole-piperazine derivatives against breast (MCF-7) cell lines prior to synthesis.

The Flexural Behavior including Ductility of Half Precast Concrete Slab with Welded Deformed Wire Fabric (용접철망을 사용한 반두께 P.C.슬래브의 휨 및 연성거동)

  • 이광수;최종수;조민형;신성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.4
    • /
    • pp.153-160
    • /
    • 1994
  • Ten Half precast concrete slabs reinforced with welded deformed wire fabric were tested under two concentrated loads to investigate the flexural moment and ductile capacity. The test variables were the compressive strength of topping concrete, quantitative roughness, and reinforcernent ratio. The effects of each test variables were studied separately. Test results were as followings. The ultimate strength design method is applicable to predict flexural strength for Half P.C. concrete slab with welded deformed wire fabric and quantitative roughness. It is proper to consider 0.0035 strain ;is yielding stress of the welded deformed wire fabric. The ductility index of Half precast concrete slab with welded deformed wire fabric showed lower value. Therefore to enhance the ductility capacity the normal defomed bar should be used with the welded deformed wire fabric for the longitudinal reinforcement.

Do Various Respirator Models Fit the Workers in the Norwegian Smelting Industry?

  • Foereland, Solveig;Robertsen, Oeystein;Hegseth, Marit Noest
    • Safety and Health at Work
    • /
    • v.10 no.3
    • /
    • pp.370-376
    • /
    • 2019
  • Background: Respirator fit testing is a method to assess if the respirator provides an adequate face seal for the worker. Methods: Workers from four Norwegian smelters were invited to participate in the study, and 701 respirator fit tests were performed on 127 workers. Fourteen respirator models were included: one FFABE1P3 and 11 FFP3 respirator models produced in one size and two silicone half masks with P3 filters available in three sizes. The workers performed a quantitative fit test according to Health and Safety Executive 282/28 with 5-6 different respirator models, and they rated the respirators based on comfort. Predictors of overall fit factors were explored. Results: The pass rate for all fit tests was 62%, 56% for women, and 63% for men. The silicone respirators had the highest percentage of passed tests (92-100%). The pass rate for the FFP3 models varied from 19-89%, whereas the FFABE1P3 respirator had a pass rate of 36%. Five workers did not pass with any respirators, and 14 passed with all the respirators tested. Only 63% passed the test with the respirator they normally used. The mean comfort score on the scale from 1 to 5 was 3.2. The respirator model was the strongest predictor of the overall fit factor. The other predictors (age, sex, and comfort score) did not improve the fit of the model. Conclusion: There were large differences in how well the different respirator models fitted the Norwegian smelter workers. The results can be useful when choosing which respirators to include in respirator fit testing programs in similar populations.

Applications for Self-Regulating Learning Strategy to Quantitative Relationships in Chemical Reaction (탐구실험 수업에 자기조절학습 전략을 적용: 학업성취도 및 과학적 태도에 대한 효과)

  • Kim, Yeon Chul;Park, Jong Keun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.487-495
    • /
    • 2021
  • Using self-regulation learning strategies that can cultivate the creative and critical thinking required in the era of the Fourth Industrial Revolution, it was applied to the exploration experimental class of the section 'quantitative relationship in chemical reactions' in high school chemistry and the effects on academic performance and scientific attitudes were analyzed. In case of academic achievement, although there was no meaningful difference between the two groups in the pre-test, the average value of the experimental group was significantly higher in the post-test. In the case of scientific attitudes, the difference in average points between the two groups was the greatest in readiness and curiosity. In the post-test of the experimental group, academic achievement showed the highest correlation with meta-cognition and scientific attitude with behavioral regulation, respectively. Considering the effectiveness of metacognition and scientific attitudes, self-regulation learning strategies are the most suitable teaching-learning forms for creativity and personality education in this era.

Comparison of fracture strength, surface hardness, and color stain of conventionally fabricated, 3D printed, and CAD-CAM milled interim prosthodontic materials after thermocycling

  • Mesut Yildirim;Filiz Aykent;Mahmut Sertac Ozdogan
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.115-125
    • /
    • 2024
  • PURPOSE. The purpose of this in vitro study was to investigate the fracture resistance, surface hardness, and color stain of 3D printed, CAD-CAM milled, and conventional interim materials. MATERIALS AND METHODS. A total of 80 specimens were fabricated from auto polymerizing polymethyl methacrylate (PMMA), bis-acryl composite resin, CAD-CAM polymethyl methacrylate resin (milled), and 3D printed composite resin (printed) (n = 20). Forty of them were crown-shaped, on which fracture strength test was performed (n = 10). The others were disc-shaped specimens (10 mm × 2 mm) and divided into two groups for surface hardness and color stainability tests before and after thermal cycling in coffee solution (n = 10). Color parameters were measured with a spectrophotometer before and after each storage period, and color differences (CIEDE2000 [DE00]) were calculated. The distribution of variables was measured with the Kolmogorov Smirnov test, and one-way analysis of variance (ANOVA), Tukey HSD, Kruskal-Wallis, Mann-Whitney U tests were used in the analysis of quantitative independent data. Paired sample t-test was used in the analysis of dependent quantitative data (P < .05). RESULTS. The highest crown fracture resistance values were determined for the 3D printed composite resin (P < .05), and the lowest were observed in the bis-acryl composite resin (P < .05). Before and after thermal cycling, increase in mean hardness values were observed only in 3D printed composite resin (P < .05) and the highest ΔE00 value were observed in PMMA resin for all materials (P < .05). CONCLUSION. 3D printing and CAD-CAM milled interim materials showed better fracture strength. After the coffee thermal cycle, the highest surface hardness value was again found in 3D printing and CAD-CAM milled interim samples and the color change of the bis-acryl resin-based samples and the additive production technique was higher than the PMMA resin and CAD-CAM milled resin samples.

A study on Broad Quantification Calibration to various isotopes for Quantitative Analysis and its SUVs assessment in SPECT/CT (SPECT/CT 장비에서 정량분석을 위한 핵종 별 Broad Quantification Calibration 시행 및 SUV 평가를 위한 팬텀 실험에 관한 연구)

  • Hyun Soo, Ko;Jae Min, Choi;Soon Ki, Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.20-31
    • /
    • 2022
  • Purpose Broad Quantification Calibration(B.Q.C) is the procedure for Quantitative Analysis to measure Standard Uptake Value(SUV) in SPECT/CT scanner. B.Q.C was performed with Tc-99m, I-123, I-131, Lu-177 respectively and then we acquired the phantom images whether the SUVs were measured accurately. Because there is no standard for SUV test in SPECT, we used ACR Esser PET phantom alternatively. The purpose of this study was to lay the groundwork for Quantitative Analysis with various isotopes in SPECT/CT scanner. Materials and Methods Siemens SPECT/CT Symbia Intevo 16 and Intevo Bold were used for this study. The procedure of B.Q.C has two steps; first is point source Sensitivity Cal. and second is Volume Sensitivity Cal. to calculate Volume Sensitivity Factor(VSF) using cylinder phantom. To verify SUV, we acquired the images with ACR Esser PET phantom and then we measured SUVmean on background and SUVmax on hot vials(25, 16, 12, 8 mm). SPSS was used to analyze the difference in the SUV between Intevo 16 and Intevo Bold by Mann-Whitney test. Results The results of Sensitivity(CPS/MBq) and VSF were in Detector 1, 2 of four isotopes (Intevo 16 D1 sensitivity/D2 sensitivity/VSF and Intevo Bold) 87.7/88.6/1.08, 91.9/91.2/1.07 on Tc-99m, 79.9/81.9/0.98, 89.4/89.4/0.98 on I-123, 124.8/128.9/0.69, 130.9, 126.8/0.71, on I-131, 8.7/8.9/1.02, 9.1/8.9/1.00 on Lu-177 respectively. The results of SUV test with ACR Esser PET phantom were (Intevo 16 BKG SUVmean/25mm SUVmax/16mm/12mm/8mm and Intevo Bold) 1.03/2.95/2.41/1.96/1.84, 1.03/2.91/2.38/1.87/1.82 on Tc-99m, 0.97/2.91/2.33/1.68/1.45, 1.00/2.80/2.23/1.57/1.32 on I-123, 0.96/1.61/1.13/1.02/0.69, 0.94/1.54/1.08/0.98/ 0.66 on I-131, 1.00/6.34/4.67/2.96/2.28, 1.01/6.21/4.49/2.86/2.21 on Lu-177. And there was no statistically significant difference of SUV between Intevo 16 and Intevo Bold(p>0.05). Conclusion Only Qualitative Analysis was possible with gamma camera in the past. On the other hand, it's possible to acquire not only anatomic localization, 3D tomography but also Quantitative Analysis with SUV measurements in SPECT/CT scanner. We could lay the groundwork for Quantitative Analysis with various isotopes; Tc-99m, I-123, I-131, Lu-177 by carrying out B.Q.C and could verify the SUV measurement with ACR phantom. It needs periodic calibration to maintain for precision of Quantitative evaluation. As a result, we can provide Quantitative Analysis on follow up scan with the SPECT/CT exams and evaluate the therapeutic response in theranosis.

Aerodynamic Analysis of Tilt-Rotor Unmanned Aerial Vehicle with Computational Fluid Dynamics

  • Kim Cheol-Wan;Chung Jin-Deog
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.561-568
    • /
    • 2006
  • CFD simulation for one of tilt-rotor UAV configurations, TR-E2S1, was performed to investigate its aerodynamic characteristics. Control surfaces such as elevator and rudder were deflected and wing incidence angle was changed. Also aerodynamic stabilities were analyzed with the variation of pitch and yaw angles. The comparison of CFD with wind tunnel test results reveals the same trends in the aerodynamic characteristics and stabilities. However 12% scale wind tunnel test model is too small for accurate data collection and should build a high fidelity model for quantitative data comparison.

Role of FT-IR in Assessing Lubricant Degradation - A Study on Palm Oil Methyl Ester Blended Lubricant

  • Maleque, M.A.;Masjuki, H.H.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.351-352
    • /
    • 2002
  • In this paper, studies were made on the palm oil methyl ester (POME) added lubricants using FT-IR for monitoring oil degradation. In order to assess the degradation characteristics of POME added lubricant by FT-IR, static oxidation test was conducted using three different blended lubricants (viz, zero percent POME, five percent POME and ten percent POME with mineral-based oil) for 280 hrs. The oxidation temperature was set at $140^{\circ}C$. FT-IR quantitative data indicate an increased in oxidation products which was formed from 10% POME added lubricants after 280 hrs of oxidation test. The 5% POME added lubricant and mineral-based lubricant (without POME) showed less oxidation product after the test. From the FT-IR spectrum analysis of the oxidized oils it could be concluded that 5% POME can improve the performance of mineral-based oil by forming protective films.

  • PDF

Quantitative Analysis of Wear Debris for Surface Modification Layer by Ferrography (Ferrography에 의한 표면개질층의 마모분 정량분석)

  • 오성모;이봉구
    • Tribology and Lubricants
    • /
    • v.15 no.3
    • /
    • pp.265-271
    • /
    • 1999
  • Wherever there are rotating equipment and contact between surface, there is wear and the generation of wear particles. The particles contained in the lubricating oil carry detailed and important information about the condition monitoring of the machine. This information may be deduced from particle shape, composition, size distribution, and concentration. Therefore, This paper was undertaken to Ferrography system of wear debris generated from lubricated moving machine surface. The lubricating wear test was performed under different experimental conditions using the Falex wear test of Pin and V-Block type by Ti(C, N) coated. It was shown from the test results that wear particle concentration (WPC) and wear severity Index( $I_{S}$), size distribution in normal and abnormal wear have come out all the higher value by increases sliding friction time. Wear shape is observed on the Ferrogram it was discovered a thin leaf wear debris as well as ball and plate type wear particles. This kind of large wear shape have an important effect not only metals damage, but also seizure phenomenon.