• Title/Summary/Keyword: quantitative computed tomography

Search Result 230, Processing Time 0.03 seconds

Bone Mineral Density and Stress Distribution in Human Patella

  • Han, Seung-Moo;Jared Davis
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.53-58
    • /
    • 1998
  • This study examined the distribution of bone mineral density(BMD) and the von Mises stress in the patella. The BMD of eighteen patellae were determined by using quantitative computed tomography and imaging analysis software. It was found that the BMD of the patella varied with location. BMD values were largest at the superior and lateral regions and decreased inferiorly and medially. This distribution appeared to correspond to the organization of trabeculae within the patella. A two-dimensional finite element analysis was performed on each patella. It was also found that the maximum von Mises stress in the patella occurred along the cortical shell on the non-articular surface. The trabecular von Mises stress existed in the posterior region of the patella. These findings demonstrated the potential for finite element studies in vivo. Further, such studies may lead to the development of custom-made, patient-specific patella prostheses.

  • PDF

Quantitative Assessment of Orbital Volume and Intraocular Pressure after Two-Wall Decompression in Thyroid Ophthalmopathy

  • Park, Sang Min;Nam, Su Bong;Lee, Jae Woo;Song, Kyeong Ho;Choi, Soo Jong;Bae, Yong Chan
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.2
    • /
    • pp.53-57
    • /
    • 2015
  • Background: Surgical outcomes after orbital wall decompression have focused on the degree of exophthalmos and intraocular pressure. The aim of this research was to evaluate intraorbital volume using computed tomography (CT) images following two-wall decompression using a combined subcilliary and endoscopic approaches. Methods: A retrospective review was performed for all patients who had undergone the two-wall decompression method. The pre/postoperative CT images were used to evaluate changes in intraocular volume. Intraocular pressure was evaluated using applanation tonometry. Surgical details are discussed within the body of text. Results: Two-wall decompression thru the medial wall and floor was associated with an average intraorbital volume change of $7.3cm^3$, with maximal accommodation up to $13cm^3$. Changes in intraocular pressures were not statistically significant. Conclusion: Two-wall decompression was effective in accommodation of up to $13cm^3$ of soft tissue herniation. There was no statistically significant association between changes in volume to pressure.

Pre- and Post-Angioplasty Perfusion CT with Acetazolamide Challenge in Patients with Unilateral Cerebrovascular Stenotic Disease

  • You, Seung-Hoon;Jo, Sung-Min;Kim, Young-June;Lee, Jong-Hyeog;Jo, Kwang-Deog;Park, Woong-Sub
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.4
    • /
    • pp.280-288
    • /
    • 2013
  • Objective : Perfusion computed tomography (PCT) has the ability to measure quantitative value and produce maps of mean transit time (MTT), cerebral blood flow (CBF), and cerebral blood volume (CBV). We assessed cerebral hemodynamics by using these parameters and acetazolamide (ACZ) challenge for pre- and post-procedural evaluation in patients with unilateral cerebrovascular stenotic disease. Methods : Thirty patients underwent pre-procedural PCT with ACZ challenge, and 24 patients (80%) was conducted follow up PCT after angioplasty with same protocol. The mean MTT, CBF, and CBV were measured and compared in both middle cerebral arterial (MCA) territories before and after ACZ challenge. Hemispheric ratio and percent change after ACZ challenge were calculated before and after angioplasty. Results : The mean stenosis rate was 76.6%. Significant increases in MTT (32.6%, p=0.000) and significant decreases in CBF (-14.2%, p=0.000) were found in stenotic side MCA territories. After ACZ challenge, there were significant changes in MTT (37.4%, p=0.000), CBF (-13.1%, p=0.000), and CBV (-10.5%, p=0.001) in pre-procedural perfusion study. However, no significant increases were found in MTT, or decreases in CBF and CBV in post-procedural study. There were no significant changes after ACZ challenge also. In addition, the degrees of these changes (before and after ACZ challenge) were highly correlated with the stenotic degrees in pre-procedural perfusion study. Conclusion : PCT with ACZ challenge appears to be a useful tool to assess the cerebral perfusion status especially in patients with unilateral symptomatic stenotic disease.

The role of surgical clips in the evaluation of interfractional uncertainty for treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy

  • Bae, Jin Suk;Kim, Dong Hyun;Kim, Won Taek;Kim, Yong Ho;Park, Dahl;Ki, Yong Kan
    • Radiation Oncology Journal
    • /
    • v.35 no.1
    • /
    • pp.65-70
    • /
    • 2017
  • Purpose: To evaluate the utility of implanted surgical clips for detecting interfractional errors in the treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy (PORT). Methods and Materials: Twenty patients had been treated with PORT for locally advanced hepatobiliary or pancreatic cancer, from November 2014 to April 2016. Patients underwent computed tomography simulation and were treated in expiratory breathing phase. During treatment, orthogonal kilovoltage (kV) imaging was taken twice a week, and isocenter shifts were made to match bony anatomy. The difference in position of clips between kV images and digitally reconstructed radiographs was determined. Clips were consist of 3 proximal clips (clip_p, ${\leq}2cm$) and 3 distal clips (clip_d, >2 cm), which were classified according to distance from treatment center. The interfractional displacements of clips were measured in the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) directions. Results: The translocation of clip was well correlated with diaphragm movement in 90.4% (190/210) of all images. The clip position errors greater than 5 mm were observed in 26.0% in SI, 1.8% in AP, and 5.4% in RL directions, respectively. Moreover, the clip position errors greater than 10 mm were observed in 1.9% in SI, 0.2% in AP, and 0.2% in RL directions, despite respiratory control. Conclusion: Quantitative analysis of surgical clip displacement reflect respiratory motion, setup errors and postoperative change of intraabdominal organ position. Furthermore, position of clips is distinguished easily in verification images. The identification of the surgical clip position may lead to a significant improvement in the accuracy of upper abdominal radiation therapy.

A Study on the Correlation between of Bone Mineral Density and Cold Hypersensitivity of Hands (골밀도와 수냉증과의 상관성 연구)

  • Lee, Dong-Nyung;Lee, Jeong-Im;Go, Ho-Yeon;Kim, Hyung-Jun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.28 no.4
    • /
    • pp.11-20
    • /
    • 2015
  • Objectives The purpose of this study was to examine the relationship between cold hypersensitivity and bone mineral density. Methods 28 outpatients who visited OO University Oriental Hospital from July 11th, 2013 to August 28th, 2013 were analyzed. Patients were subjected to thermometer, and those with thermal difference greater than 0.3 ℃ between upper arm and palm and also with more than VAS 4 of cold hypersensitivity were diagnosed with cold sensitivity. Lumba spine (L2-4) and heel bone measurement were obtained on dual energy X-ray absorptiometry (DEXA) and Quantitative Computed Tomography (QCT). Results 1. There was statistically significant correlation between T-score of DEXA and body weight (0.522), BMI (0.643), OSTA (Osteoporosis elf-assesment Tool for Asians, 0.579), BMI, T-score and Z-score of QCT. OSTA and T-score of QCT (0.521) also had statistically significance. 2. There was no statistically significant correlation between body fat, abdominal obesity rate, degree of cold hypersensitivity, upper arm and palm's temperature difference, palm temperature, height and Z-score, T-score of QCT or T-sore of DEXA. Conclusions Bone mineral density was lower in women who had cold hypersensitivity of hand and feet. But there was no statistically significant correlation between bone mineral density and degree of cold hypersensitivity, upper arm and palm’s temperature difference.

The Study on Relation of Low back pain and Bone Mineral Density (요통(腰痛)과 골밀도(骨密度)와의 상관성(相關性)에 관한 연구)

  • Park, sang dong;Kim, Kyung Ho;Jang, Jun-Hyouk;Kim, Jeong Seok
    • Journal of Acupuncture Research
    • /
    • v.18 no.2
    • /
    • pp.91-100
    • /
    • 2001
  • Objective : The purpose of this study is to investigate the role of the osteoporosis in low back pain(LBP). Methods : We use method of projection with Quantitative computed tomography(QCT) to estimate Bone mineral density(BMD) of lumbar spine more precisely. From January 1999 to August 2000 we studied lumbar BMD of 46 women with LBP and 53 women with non-LBP, musculoskeletal symptoms who visited Dong-Guk University Bundang Hospital by QCT. Results : 1. Lumbar BMDs in women with LBP and women with non-LBP, musculoskeletal symptom were lower than in normal women and BMDs in women with LBP was higher than in women with non-LBP, musculoskeletal symptom but the significant difference was not revealed between two group in statistics(p<0.05).. 2. Radiological study shows that the number of degenerative spondylosis was 19, compression fracture was 11, non-radiological study was 10, normal was 5 in women with LBP. 3. Radiological study shows that the number of degenerative change was 7, compression fracture was zero, non-radiological study was 33, normal was 5 in women with non-LBP, musculoskeletal symptom. Conclusion : BMDs in women with LBP was higher than in women with non-LBP, musculoskeletat symptom but the significant difference was not revealed between two group in statistics(p<0.05).

  • PDF

Correlations between Acoustic Properties and Bone Mineral Density in Bovine Femoral Trabecular Bone In Vitro (생체 외 조건의 소 대퇴골 해면질골에서 음향특성과 골밀도 사이의 상관관계)

  • Hwang, Kyo-Seung;Seo, Dong-Wan;Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.4
    • /
    • pp.244-252
    • /
    • 2012
  • The purpose of the present study is to investigate the correlations between acoustic properties, such as speed of sound and normalized broadband ultrasound attenuation, and bone mineral density in femur with high fracture risk. The speed of sound and the normalized broadband ultrasound attenuation in 15 bovine femoral trabecular bone samples in vitro were measured by using a through-transmission method with two matched pairs of ultrasonic transducers with center frequencies of 0.5 and 1.0 MHz. The volumetric bone mineral density of the trabecular bone samples was measured by using micro-computed tomography. The bone mineral density exhibited strong correlations with both the speed of sound and the normalized broadband ultrasound attenuation measured by using the 0.5 and the 1.0 MHz transducers. The highest correlation was found between the bone mineral density and the normalized broadband ultrasound attenuation measured by using the 0.5 MHz ultrasonic transducers. The results suggest that the acoustic properties measured in the femur in vitro can be used as indices for the prediction of femoral bone mineral density.

Bone Healing Properties of Autoclaved Autogenous Bone Grafts Incorporating Recombinant Human Bone Morphogenetic Protein-2 and Comparison of Two Delivery Systems in a Segmental Rabbit Radius Defect

  • Choi, Eun Joo;Kang, Sang-Hoon;Kwon, Hyun-Jin;Cho, Sung-Won;Kim, Hyung Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.3
    • /
    • pp.94-102
    • /
    • 2014
  • Purpose: This study aims to validate the effect of autoclaved autogenous bone (AAB), incorporating Escherichia coli-derived recombinant human bone morphogenetic protein-2 (ErhBMP-2), on critical-sized, segmental radius defects in rabbits. Delivery systems using absorbable collagen sponge (ACS) and fibrin glue (FG) were also evaluated. Methods: Radius defects were made in 12 New Zealand white rabbits. After autoclaving, the resected bone was reinserted and fixed. The animals were classified into three groups: only AAB reinserted (group 1, control), and AAB and ErhBMP-2 inserted using an ACS (group 2) or FG (group 3) as a carrier. Animals were sacrificed six or 12 weeks after surgery. Specimens were evaluated using radiology and histology. Results: Micro-computed tomography images showed the best bony union in group 2 at six and 12 weeks after operation. Quantitative analysis showed all indices except trabecular thickness were the highest in group 2 and the lowest in group 1 at twelve weeks. Histologic results showed the greatest bony union between AAB and radial bone at twelve weeks, indicating the highest degree of engraftment. Conclusion: ErhBMP-2 increases bony healing when applied on AAB graft sites. In addition, the ACS was reconfirmed as a useful delivery system for ErhBMP-2.

Ultrasound Attenuation in the Assessment of Bone Mineral Density and Elastic Modulus of Human Trabecular Bone

  • Han, S.M.;Kim, M.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.171-176
    • /
    • 1998
  • The objective of this study was to re-evaluate ultrasound attenuation as an indicator of bone properties. Ultrasound attenuation(BUA), were measured in the three orthogonal directions of trabecular bone cubes, Measurements of bone mineral density(BMD) were made using quantitative computed tomography and apparent density by weighing bone specimens and measuring their volume. Ultrasonic modulus was calculated from the standard equation with apparent density and ultrasound velocity. Ultrasound attenuation at a frequency of 0.5 MHz and BUA were correlated with BMD and ultrasonic modulus in the anterior/posterior, medial/lateral, and superior/inferior directions. Analysis of correlations demonstrated that attenuation at 0.5 MHz was superior to BUA in describing both BMD and elastic modulus of trabecular bone. This result may be used to improve current ultrasound diagnostic techniques for assessing bone status.

  • PDF

Development of Triaxial Cells Operable with In Situ X-ray CT for Hydro-Mechanical Laboratory Testing of Rocks (원위치 X-ray CT 촬영이 가능한 암석의 수리-역학 실험용 삼축셀 개발)

  • Zhuang, Li;Yeom, Sun;Shin, Hyu-Soung
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.9
    • /
    • pp.45-55
    • /
    • 2020
  • X-ray computed tomography (CT) is very useful for the quantitative evaluation of internal structures, particularly defects in rock samples, such as pores and fractures. In situ CT allows 3D imaging of a sample subjected to various external treatments such as loading and therefore enables observation of changes that occur during the loading process. We reviewed state-of-the-art of in situ CT applications for geomaterials. Two triaxial cells made using relatively low density but high strength materials were developed aimed at in situ CT scanning during hydro-mechanical laboratory testing of rocks. Preliminary results for in situ CT imaging of granite and sandstone samples with diameters ranging from 25 mm to 50 mm show a resolution range of 34~105 ㎛ per pixel pitch, indicating the feasibility of in situ CT observations for internal structural changes in rocks at the micrometer scale. Potassium iodide solution was found to improve the image contrast, and can be used as an injection fluid for hydro-mechanical testing combined with in situ CT scanning.