• Title/Summary/Keyword: quantitative computed tomography

Search Result 228, Processing Time 0.028 seconds

Usefulness of Bone SPECT/CT for Predicting Avascular Necrosis of the Femoral Head in Children with Slipped Capital Femoral Epiphysis or Femoral Neck Fracture

  • Yoo Sung Song;Won Woo Lee;Moon Seok Park;Nak Tscheol Kim;Ki Hyuk Sung
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.264-270
    • /
    • 2022
  • Objective: This study aimed to investigate the usefulness of bone single-positron emission tomography/computed tomography (SPECT/CT) of the hip in predicting the later occurrence of avascular necrosis (AVN) after slipped capital femoral epiphysis (SCFE) or femoral neck fracture in pediatric patients. The quantitative parameters of SPECT/CT useful in predicting AVN were identified. Materials and Methods: Twenty-one (male:female, 10:11) consecutive patients aged < 18 years (mean age ± standard deviation [SD], 11.0 ± 2.7 years) who underwent surgery for SCFE or femoral neck fracture and postoperative bone SPECT/CT were included. The maximum standardized uptake value (SUV), mean SUV, and minimum SUV of the femoral head were measured. The ratios of the maximum SUV, mean SUV, and minimum SUV of the affected femoral head to the contralateral side were determined. Patients were followed up for > 1 year after the surgery. The SPECT/CT parameters were compared between patients who developed AVN and those who did not. The accuracy of SPECT/CT parameters for predicting AVN was assessed. Results: Six patients developed AVN. There was a significant difference in the ratio of the mean SUV among patients who developed AVN (mean ± SD, 0.8 ± 0.3) and those who did not (1.1 ± 0.2, p = 0.018). However, there were no significant differences in the ratios of the maximum and minimum SUV between the groups (all p = 0.205). For the maximum, mean, and minimum SUVs, no significant differences were observed between the groups (p = 0.519, 0.733, and 0.470, respectively). The cutoff mean SUV ratio of 0.87 yielded a 66.7% sensitivity and 93.2% specificity for predicting AVN. Conclusion: Quantitative bone SPECT/CT is useful for evaluating femoral head viability in pediatric patients with SCFE or femoral neck fractures. Clinicians should consider the high possibility of later AVN development in patients with a decreased mean SUV ratio.

Evaluation of Usefulness of an m-DIXON Technique during an Abdomen MRI Examination : A Comparison with an e-THRIVE Technique (복부 MRI검사에서 m-DIXON기법의 유용성 평가: e-THRIVE기법과 비교 분석)

  • Lee, Bo-Woo;Park, Myung-Cheol;Lee, Jin-Hoi;Kim, Ki-Jin;Bae, Seok-Hwan
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.385-390
    • /
    • 2014
  • This research is conducted to identify whether an m-DIXON technique which is useful for an abdomen MRI examination compared with an existing e-THRIVE technique is a clinically useful or not. There was evaluated quantitative and qualitative to 84 subjects who had abdomen MRI exam due to their liver disease were conducted during a period from September in 2013 to February in 2014. First of all the quantitative evaluation, the m-DIXON technique's SNR was $90.42{\pm}16.90$ and the e-THRIVE technique was $60.42{\pm}11.54$ and the m-DIXON technique's CNR was $52.38{\pm}22.58$ and the e-THRIVE technique was $46.31{\pm}20.25$. Secondly in the qualitative evaluation, the m-DIXON technique's image quality was $4.06{\pm}0.34$, a artifact was $3.64{\pm}0.22$, and fat suppression was $4.16{\pm}0.15$, the e-THRIVE technique's image quality was $3.14{\pm}0.35$, a artifact was $3.06{\pm}0.38$, fat suppression was $3.14{\pm}0.30$. In conclusion, m-DIXON technique for abdomen MRI examination showed superiority over both SNR as a quantitative anaylsis, CNR and a qualitative analysis.

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

Study of the Optimize Radiotherapy Treatment Planning (RTP) Techniques in Patients with Early Breast Cancer; Inter-comparison of 2D and 3D (3DCRT, IMRT) Delivery Techniques (유방암 방사선치료 시 최적의 방사선치료계획기법에 대한 고찰)

  • Kim, Young-Bum;Lee, Sang-Rok;Chung, Se-Young;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • Purpose: A various find of radiotherapy treatment plans have been made to determine appropriate doses for breasts, chest walls and loco-regional lymphatics in the radiotherapy of breast cancers. The aim of this study was to evaluate the optimum radiotherapy plan technique method by analyzing dose distributions qualitatively and quantitatively. Materials and Methods: To evaluate the optimum breast cancer radiotherapy plan technique, the traditional method(two dimensional method) and computed tomography image are adopted to get breast volume, and they are compared with the three-dimensional conformal radiography (3DCRT) and the intensity modulated radiotherapy (IMRT). For this, the regions of interest (ROI) such as breasts, chest walls, loco-regional lymphatics and lungs were marked on the humanoid phantom, and the computed tomography(Volume, Siemens, USA) was conducted. Using the computed tomography image obtained, radiotherapy treatment plans (XiO 5.2.1, FOCUS, USA) were made and compared with the traditional methods by applying 3DCRT and IMRT. The comparison and analysis were made by analyzing and conducting radiation dose distribution and dose-volume histogram (DVH) based upon radiotherapy techniques (2D, 3DCRT, IMRT) and point doses for the regions of interest. Again, treatment efficiency was evaluated based upon time-labor. Results: It was found that the case of using 3DCRT plan techniques by getting breast volume is more useful than the traditional methods in terms of tumor delineation, beam direction and confirmation of field boundary. Conclusion: It was possible to present the optimum radiotherapy plan techniques through qualitative and quantitative analyses based upon radiotherapy plan techniques in case of breast cancer radiotherapy. However, further studies are required for the problems with patient setup reproducibility arising from the difficulties of planning target volume (PVT) and breast immobilization in case of three-dimensional radiotherapy planning.

  • PDF

Subjective and Objective Assessment of Monoenergetic and Polyenergetic Images Acquired by Dual-Energy CT in Breast Cancer

  • Xiaoxia Wang;Daihong Liu;Shixi Jiang;Xiangfei Zeng;Lan Li;Tao Yu;Jiuquan Zhang
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.502-512
    • /
    • 2021
  • Objective: To objectively and subjectively assess and compare the characteristics of monoenergetic images [MEI (+)] and polyenergetic images (PEI) acquired by dual-energy CT (DECT) of patients with breast cancer. Materials and Methods: This retrospective study evaluated the images and data of 42 patients with breast cancer who had undergone dual-phase contrast-enhanced DECT from June to September 2019. One standard PEI, five MEI (+) in 10-kiloelectron volt (keV) intervals (range, 40-80 keV), iodine density (ID) maps, iodine overlay images, and Z effective (Zeff) maps were reconstructed. The contrast-to-noise ratio (CNR) and the signal-to-noise ratio (SNR) were calculated. Multiple quantitative parameters of the malignant breast lesions were compared between the arterial and the venous phase images. Two readers independently assessed lesion conspicuity and performed a morphology analysis. Results: Low keV MEI (+) at 40-50 keV showed increased CNR and SNRbreast lesion compared with PEI, especially in the venous phase ([CNR: 40 keV, 20.10; 50 keV, 14.45; vs. PEI, 7.27; p < 0.001], [SNRbreast lesion: 40 keV, 21.01; 50 keV, 16.28; vs. PEI, 10.77; p < 0.001]). Multiple quantitative DECT parameters of malignant breast lesions were higher in the venous phase images than in the arterial phase images (p < 0.001). MEI (+) at 40 keV, ID, and Zeff reconstructions yielded the highest Likert scores for lesion conspicuity. The conspicuity of the mass margin and the visual enhancement were significantly better in 40-keV MEI (+) than in the PEI (p = 0.022, p = 0.033, respectively). Conclusion: Compared with PEI, MEI (+) reconstructions at low keV in the venous phase acquired by DECT improved the objective and subjective assessment of lesion conspicuity in patients with malignant breast lesions. MEI (+) reconstruction acquired by DECT may be helpful for the preoperative evaluation of breast cancer.

Clinical Implications of Focal Mineral Deposition in the Globus Pallidus on CT and Quantitative Susceptibility Mapping of MRI

  • Hyojin Kim;Jinhee Jang;Junghwa Kang;Seungun Jang;Yoonho Nam;Yangsean Choi;Na-young Shin;Kook-Jin Ahn;Bum-soo Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.7
    • /
    • pp.742-751
    • /
    • 2022
  • Objective: To assess focal mineral deposition in the globus pallidus (GP) by CT and quantitative susceptibility mapping (QSM) of MRI scans and evaluate its clinical significance, particularly cerebrovascular degeneration. Materials and Methods: This study included 105 patients (66.1 ± 13.7 years; 40 male and 65 female) who underwent both CT and MRI with available QSM data between January 2017 and December 2019. The presence of focal mineral deposition in the GP on QSM (GPQSM) and CT (GPCT) was assessed visually using a three-point scale. Cerebrovascular risk factors and small vessel disease (SVD) imaging markers were also assessed. The clinical and radiological findings were compared between the different grades of GPQSM and GPCT. The relationship between GP grades and cerebrovascular risk factors and SVD imaging markers was assessed using univariable and multivariable linear regression analyses. Results: GPCT and GPQSM were significantly associated (p < 0.001) but were not identical. Higher GPCT and GPQSM grades showed smaller gray matter (p = 0.030 and p = 0.025, respectively) and white matter (p = 0.013 and p = 0.019, respectively) volumes, as well as larger GP volumes (p < 0.001 for both). Among SVD markers, white matter hyperintensity was significantly associated with GPCT (p = 0.006) and brain atrophy was significantly associated with GPQSM (p = 0.032) in at univariable analysis. In multivariable analysis, the normalized volume of the GP was independently positively associated with GPCT (p < 0.001) and GPQSM (p = 0.002), while the normalized volume of the GM was independently negatively associated with GPCT (p = 0.040) and GPQSM (p = 0.035). Conclusion: Focal mineral deposition in the GP on CT and QSM might be a potential imaging marker of cerebral vascular degeneration. Both were associated with increased GP volume.

Comparison of Left Ventricular Volume and Function between 46 Channel Multi-detector Computed Tomography (MDCT) and Echocardiography (16 채널 Multi-detector 컴퓨터 단층촬영과 심초음파를 이용한 좌심실 용적과 기능의 비교)

  • Park, Chan-Beom;Cho, Min-Seob;Moon, Mi-Hyoung;Cho, Eun-Ju;Lee, Bae-Young;Kim, Chi-Kyung;Jin, Ung
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.45-51
    • /
    • 2007
  • Background: Although echocardiography is usually used for quantitative assessment of left ventricular function, the recently developed 16-slice multidetector computed tomography (MDCT) is not only capable of evaluating the coronary arteries but also left ventricular function. Therefore, the objective of our study was to compare the values of left ventricular function quantified by MDCT to those by echocardiography for evaluation of its regards to clinical applications. Material and Method: From 49 patients who underwent MDCT in our hospital from November 1, 2003 to January 31, 2005, we enrolled 20 patients who underwent echocardiography during the same period for this study. Left ventricular end-diastolic volume index (LVEDVI), left ventricular end-systolic volume index (LVESVI), stroke volume index (SVI), left ventricular mass index (LVMI), and ejection fraction (EF) were analyzed. Result: Average LVEDVI ($80.86{\pm}34.69mL$ for MDCT vs $60.23{\pm}29.06mL$ for Echocardiography, p<0.01), average LVESVI ($37.96{\pm}24.52mL$ for MDCT vs $25.68{\pm}16.57mL$ for Echocardiography, p<0.01), average SVI ($42.90{\pm}15.86mL$ for MDCT vs $34.54{\pm}17.94mL$ for Echocardiography, p<0.01), average LVMI ($72.14{\pm}25.35mL$ for MDCT vs $130.35{\pm}53.10mL$ for Echocardiography, p<0.01), and average EF ($55.63{\pm}12.91mL$ for MOCT vs $59.95{\pm}12.75ml$ for Echocardiography, p<0.05) showed significant difference between both groups. Average LVEDVI, average LVESVI, and average SVI were higher in MDCT, and average LVMI and average EF were higher in echocardiogram. Comparing correlation for each parameters between both groups, LVEDVI $(r^2=0.74,\;p<0.0001)$, LVESVI $(r^2=0.69,\;p<0.0001)$ and SVI $(r^2=0.55,\;p<0.0001)$ showed high relevance, LVMI $(r^2=0.84,\;p<0.0001)$ showed very high relevance, and $EF (r^2=0.45,\;p=0.0002)$ showed relatively high relevance. Conclusion: Quantitative assessment of left ventricular volume and function using 16-slice MDCT showed high relevance compared with echocardiography, therefore may be a feasible assessment method. However, because the average of each parameters showed significant difference, the absolute values between both studies may not be appropriate for clinical applications. Furthermore, considering the future development of MDCT, we expect to be able to easily evaluate the assessment of coronary artery stenosis along with left ventricular function in coronary artery disease patients.

The Correlation of Metabolic Syndrome Factors and Bone Mineral Density on Postmenopausal Osteoporosis Patients with Low Back Pain under Korean Medicine Treatment

  • Lee, Jong Deok;Kim, Dong Woung;Kwon, Young Dal
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.24 no.1
    • /
    • pp.101-109
    • /
    • 2014
  • Objectives The relationship between metabolic syndrome causes and bone mineral density (BMD) was explored by taking 60 female chronic low back pain patients with age 61 years old or elder having metabolic syndrome and osteoporosis as study subjects. Methods Fasting blood glucose, serum total-cholesterol, triglyceride and HDL were measured by biochemical tests. Anthropometric elements and blood pressure were measured. Results Average BMD and T-score of part number 1 to 3 of lumbar vertebra were estimated by Quantitative Computed Tomography (QCT). In order to find the relationship between clinical factors and osteoporosis, correlation analysis was done on T-score. Age (r=0.679, p<0.01) had significant negative correlation and weight (r=0.342, p<0.01) and height (r=0.475, p<0.01) had significant positive correlation. Blood glucose, blood pressure, total cholesterol, triglyceride, HDL and body mass index did not have significant correlation. BMD had negative correlation with age (r=0.317, p<0.05). Regression analysis was done by taking T-score as independent variables and taking other factors as dependent variables. It was possible to know that age ($\beta$=-0.471, t=-7.050) with p<0.001, height ($\beta$=0.277, t=4.120) and weight ($\beta$=2.856, t=2.780) with p<0.05 have significant impact on osteoporosis. Conclusions Therefore, it was possible to know that T-score and BMD decrease as one gets older and T-score and BMD increase as one is taller and heavier.

Bone Mineral Density and Stress Distribution in Human Patella

  • Han, Seung-Moo;Jared Davis
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.53-58
    • /
    • 1998
  • This study examined the distribution of bone mineral density(BMD) and the von Mises stress in the patella. The BMD of eighteen patellae were determined by using quantitative computed tomography and imaging analysis software. It was found that the BMD of the patella varied with location. BMD values were largest at the superior and lateral regions and decreased inferiorly and medially. This distribution appeared to correspond to the organization of trabeculae within the patella. A two-dimensional finite element analysis was performed on each patella. It was also found that the maximum von Mises stress in the patella occurred along the cortical shell on the non-articular surface. The trabecular von Mises stress existed in the posterior region of the patella. These findings demonstrated the potential for finite element studies in vivo. Further, such studies may lead to the development of custom-made, patient-specific patella prostheses.

  • PDF

Quantitative Assessment of Orbital Volume and Intraocular Pressure after Two-Wall Decompression in Thyroid Ophthalmopathy

  • Park, Sang Min;Nam, Su Bong;Lee, Jae Woo;Song, Kyeong Ho;Choi, Soo Jong;Bae, Yong Chan
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.2
    • /
    • pp.53-57
    • /
    • 2015
  • Background: Surgical outcomes after orbital wall decompression have focused on the degree of exophthalmos and intraocular pressure. The aim of this research was to evaluate intraorbital volume using computed tomography (CT) images following two-wall decompression using a combined subcilliary and endoscopic approaches. Methods: A retrospective review was performed for all patients who had undergone the two-wall decompression method. The pre/postoperative CT images were used to evaluate changes in intraocular volume. Intraocular pressure was evaluated using applanation tonometry. Surgical details are discussed within the body of text. Results: Two-wall decompression thru the medial wall and floor was associated with an average intraorbital volume change of $7.3cm^3$, with maximal accommodation up to $13cm^3$. Changes in intraocular pressures were not statistically significant. Conclusion: Two-wall decompression was effective in accommodation of up to $13cm^3$ of soft tissue herniation. There was no statistically significant association between changes in volume to pressure.