• Title/Summary/Keyword: quality measurement

Search Result 4,484, Processing Time 0.031 seconds

Development of Ceramide NP Analysis Method in Cosmetic Formulations Using Liquid Chromatography (액체크로마토그래피를 이용한 화장품 제형 내 세라마이드엔피 분석법 확립)

  • Ye Ji Lee;Young Eun Kim;Jae Yong Seo;Hyun Dae Cho
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.4
    • /
    • pp.291-298
    • /
    • 2023
  • In this study, a quantitative analysis method was developed using high-performance liquid chromatography (HPLC) to analyze the content of ceramide NP in lotion, cream, and cleanser formulations in cosmetics. The analysis was performed using a C18 column, and the mobile phase was set at a ratio of 70 : 30 for acetonitrile and methanol, the flow rate was set to 0.8 mL/min, and the column temperature was set to 20 ℃. The method was verified by analyzing specificity, linearity, limit of detection, limit of quantitation, accuracy, and precision in accordance with the ICH guidelines. As a result of validating the method, the linearity of the calibration curve was excellent (R2 = 0.99984). The accuracy of the lotion, cream, and cleanser formulations was confirmed with a recovery rate ranging from 95.11% to 100.48%. The precision analysis showed a low relative standard deviation (RSD) of less than 0.26%. The limit of detection was 0.902 ㎍/mL, and the limit of quantitation was 2.733 ㎍/mL. Through this quantitative analysis method of ceramide NP applied in cosmetics, it is expected to assist in the quality control of products by enabling measurement even when it is difficult to separate the main peak due to the influence of interfering substances.

A study on TOC monitoring and spatial distribution analysis using a spectrometer in rivers (하천에서의 분광측정기를 이용한 TOC 모니터링 및 공간분포 분석 연구)

  • Yoon, Soo Bin;Lee, Chang Hyun;Kim, Young Do
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.815-822
    • /
    • 2023
  • Organic pollution is one of the most common forms of water contamination. Under the Water Quality Conservation Act, indicators for measuring organic substances include BOD, COD, and TOC. Analysis of BOD and COD is labor-intensive, and in the case of organic substances where biological decomposition is not feasible or toxic substances are present, the accuracy is often low. Therefore, the Ministry of Environment is shifting towards TOC-centric management. With advancements in sensor technology today, various parameters can be monitored using sensors. In this study, digital monitoring of river TOC using a spectrophotometer called Spectro::lyser V3 was conducted. Initially, experiments were carried out at the Andong River Experiment Center to assess the applicability of the measurement equipment. Subsequently, data collected at the confluence of the Nakdong River was analyzed for the spatial distribution of TOC using the Kriging technique. This research proposes the utilization of sensors for river TOC monitoring and spatial distribution analysis. Real-time monitoring of changes in river TOC concentration can serve as fundamental data for pollution monitoring and response. Sensor-based river monitoring offers advantages in terms of temporal resolution and real-time data acquisition. When various spatial information interpretation methods are applied, it is expected to contribute to diverse studies such as aquatic ecological health, river water source selection, and stratification analysis in the future.

The Effect of Oriental Medicine Treatments for Supraspinatus Tendinopathy: Systematic Review and Meta-Analysis (극상근 건병증의 한의학적 치료에 대한 연구 동향: 체계적 문헌 고찰과 메타 분석)

  • Dong-Hyeob Kang;Do-Hoon Lee;Sang-Joon Yoo;Seok-Gyu Yang;Ja-Yean Son;Seol Jung;Hea-Ju Kim;Minjin Kwon;Oh-Bin Kwon;Seon-Woo Jang;Hyun-Woo Cho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.4
    • /
    • pp.45-59
    • /
    • 2023
  • Objectives The aim of this study was to analyze the trends of researches on oriental medicine treatments for supraspinatus tendinopathy. Methods We used five databases for searching researches; Korean studies Information Service System, Oriental Medicine Advanced Searching Integrated System, Research Information Sharing Service, PubMed, and China National Knowledge Infrastructure. Only randomized controlled trials suitable for the subject were selected. The methodological quality of included randomized controlled trials (RCTs) was assessed by the Cochrane risk of bias tool. Results Twenty randomized controlled trials were analyzed. There were 9 types of treatment interventions; acupuncture, acupotomy, pharmacopuncture, electroacupuncture, fire needling, warming needle, catgut-embedding therapy, herbal medicine, cupping. The most frequently used treatment intervention was acupuncture and acupotomy. There were 9 outcome measurements including visual analog scale (VAS), Constant-Murley Score (CMS), and range of motion. The most used measurement was VAS. As a result of meta-analysis, acupuncture was more effective than control group in VAS. Additionally, acupotomy was clinically significant compared to control groups in VAS and CMS. Conclusions In this review, we analyzed researches on effectiveness of oriental medicine for supraspinatus tendinopathy. A provisional conclusion can be produced that acupuncture and acupotomy showed beneficial effect to supraspinatus tendinopathy. Although there were some RCT studies, many of them had a high risk of bias, so it is hard to conclude that our study can include overall clinical status. Further well-designed trials are needed.

Evaluation of the correlation between the muscle fat ratio of pork belly and pork shoulder butt using computed tomography scan

  • Sheena Kim;Jeongin Choi;Eun Sol Kim;Gi Beom Keum;Hyunok Doo;Jinok Kwak;Sumin Ryu;Yejin Choi;Sriniwas Pandey;Na Rae Lee;Juyoun Kang;Yujung Lee;Dongjun Kim;Kuk-Hwan Seol;Sun Moon Kang;In-Seon Bae;Soo-Hyun Cho;Hyo Jung Kwon;Samooel Jung;Youngwon Lee;Hyeun Bum Kim
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.4
    • /
    • pp.809-815
    • /
    • 2023
  • This study was conducted to find out the correlation between meat quality and muscle fat ratio in pork part meat (pork belly and shoulder butt) using CT (computed tomography) imaging technique. After 24 hours from slaughter, pork loin and belly were individually prepared from the left semiconductors of 26 pigs for CT measurement. The image obtained from CT scans was checked through the picture archiving and communications system (PACS). The volume of muscle and fat in the pork belly and shoulder butt of cross-sectional images taken by CT was estimated using Vitrea workstation version 7. This assemblage was further processed through Vitrea post-processing software to automatically calculate the volumes (Fig. 1). The volumes were measured in milliliters (mL). In addition to volume calculation, a three-dimensional reconstruction of the organ under consideration was generated. Pearson's correlation coefficient was analyzed to evaluate the relationship by region (pork belly, pork shoulder butt), and statistical processing was performed using GraphPad Prism 8. The muscle-fat ratios of pork belly taken by CT was 1 : 0.86, while that of pork shoulder butt was 1 : 0.37. As a result of CT analysis of the correlation coefficient between pork belly and shoulder butt compared to the muscle-fat ratio, the correlation coefficient was 0.5679 (R2 = 0.3295, p < 0.01). CT imaging provided very good estimates of muscle contents in cuts and in the whole carcass.

Korean Society of Heart Failure Guidelines for the Management of Heart Failure: Management of the Underlying Etiologies and Comorbidities of Heart Failure

  • Sang Min Park;Soo Youn Lee;Mi-Hyang Jung;Jong-Chan Youn;Darae Kim;Jae Yeong Cho;Dong-Hyuk Cho;Junho Hyun;Hyun-Jai Cho;Seong-Mi Park;Jin-Oh Choi;Wook-Jin Chung;Seok-Min Kang;Byung-Su Yoo;Committee of Clinical Practice Guidelines, Korean Society of Heart Failure
    • Korean Circulation Journal
    • /
    • v.53 no.7
    • /
    • pp.425-451
    • /
    • 2023
  • Most patients with heart failure (HF) have multiple comorbidities, which impact their quality of life, aggravate HF, and increase mortality. Cardiovascular comorbidities include systemic and pulmonary hypertension, ischemic and valvular heart diseases, and atrial fibrillation. Non-cardiovascular comorbidities include diabetes mellitus (DM), chronic kidney and pulmonary diseases, iron deficiency and anemia, and sleep apnea. In patients with HF with hypertension and left ventricular hypertrophy, renin-angiotensin system inhibitors combined with calcium channel blockers and/or diuretics is an effective treatment regimen. Measurement of pulmonary vascular resistance via right heart catheterization is recommended for patients with HF considered suitable for implantation of mechanical circulatory support devices or as heart transplantation candidates. Coronary angiography remains the gold standard for the diagnosis and reperfusion in patients with HF and angina pectoris refractory to antianginal medications. In patients with HF and atrial fibrillation, longterm anticoagulants are recommended according to the CHA2DS2-VASc scores. Valvular heart diseases should be treated medically and/or surgically. In patients with HF and DM, metformin is relatively safer; thiazolidinediones cause fluid retention and should be avoided in patients with HF and dyspnea. In renal insufficiency, both volume status and cardiac performance are important for therapy guidance. In patients with HF and pulmonary disease, beta-blockers are underused, which may be related to increased mortality. In patients with HF and anemia, iron supplementation can help improve symptoms. In obstructive sleep apnea, continuous positive airway pressure therapy helps avoid severe nocturnal hypoxia. Appropriate management of comorbidities is important for improving clinical outcomes in patients with HF.

Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry (대퇴골 경부 골절 환자에서 골다공증 평가를 위한 다중검출 CT의 이용: 이중에너지 X-선 흡수계측법과의 비교)

  • Hyo Jeong Lee;Ji Young Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.173-181
    • /
    • 2021
  • Purpose To evaluate the ability of the Hounsfield unit (HU) measurement of the femoral neck during multidetector computed tomography (MDCT) for assessing osteoporosis compared with dual-energy X-ray absorptiometry (DXA). Materials and Methods Forty-two patients with femoral neck fractures who underwent MDCT and DXA from July to December 2016 were included in this study. HU measurements were made of the cancellous portions of the normal contralateral femoral neck on MDCT. Bone mineral density (BMD) and T-scores were obtained at the femur DXA. Correlations of HU values with BMD and T-scores were analyzed using Spearman's correlation test. Results The mean BMD and T-score of the femoral neck were 0.650 g/cm2 and -2.4, respectively. The mean HU values for the normal, osteopenia, and osteoporosis groups were 131.9, 98.9, and 41.3, respectively. HU values at the femoral neck were positively correlated with BMD (r2 = 0.670; p < 0.001) and T-scores (r2 = 0.676; p < 0.001). Conclusion The HU values of the femoral neck on MDCT are significantly correlated with BMD and T-scores of femur DXA. The HU values may serve as a diagnostic tool for the screening of regional bone quality when MDCT is performed for other reasons.

2023 Survey on User Experience of Artificial Intelligence Software in Radiology by the Korean Society of Radiology

  • Eui Jin Hwang;Ji Eun Park;Kyoung Doo Song;Dong Hyun Yang;Kyung Won Kim;June-Goo Lee;Jung Hyun Yoon;Kyunghwa Han;Dong Hyun Kim;Hwiyoung Kim;Chang Min Park;Radiology Imaging Network of Korea for Clinical Research (RINK-CR)
    • Korean Journal of Radiology
    • /
    • v.25 no.7
    • /
    • pp.613-622
    • /
    • 2024
  • Objective: In Korea, radiology has been positioned towards the early adoption of artificial intelligence-based software as medical devices (AI-SaMDs); however, little is known about the current usage, implementation, and future needs of AI-SaMDs. We surveyed the current trends and expectations for AI-SaMDs among members of the Korean Society of Radiology (KSR). Materials and Methods: An anonymous and voluntary online survey was open to all KSR members between April 17 and May 15, 2023. The survey was focused on the experiences of using AI-SaMDs, patterns of usage, levels of satisfaction, and expectations regarding the use of AI-SaMDs, including the roles of the industry, government, and KSR regarding the clinical use of AI-SaMDs. Results: Among the 370 respondents (response rate: 7.7% [370/4792]; 340 board-certified radiologists; 210 from academic institutions), 60.3% (223/370) had experience using AI-SaMDs. The two most common use-case of AI-SaMDs among the respondents were lesion detection (82.1%, 183/223), lesion diagnosis/classification (55.2%, 123/223), with the target imaging modalities being plain radiography (62.3%, 139/223), CT (42.6%, 95/223), mammography (29.1%, 65/223), and MRI (28.7%, 64/223). Most users were satisfied with AI-SaMDs (67.6% [115/170, for improvement of patient management] to 85.1% [189/222, for performance]). Regarding the expansion of clinical applications, most respondents expressed a preference for AI-SaMDs to assist in detection/diagnosis (77.0%, 285/370) and to perform automated measurement/quantification (63.5%, 235/370). Most respondents indicated that future development of AI-SaMDs should focus on improving practice efficiency (81.9%, 303/370) and quality (71.4%, 264/370). Overall, 91.9% of the respondents (340/370) agreed that there is a need for education or guidelines driven by the KSR regarding the use of AI-SaMDs. Conclusion: The penetration rate of AI-SaMDs in clinical practice and the corresponding satisfaction levels were high among members of the KSR. Most AI-SaMDs have been used for lesion detection, diagnosis, and classification. Most respondents requested KSR-driven education or guidelines on the use of AI-SaMDs.

Field Applicability Evaluation of Monotype Load Cell for Load-Distributing Anchor (하중 분산형 앵커 내하체에 대한 모노타입 하중계의 현장 적용성 평가)

  • Yong-Jae Song;Kang-Il Lee;Yong-Chai Chang;Sang-Yong Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.3
    • /
    • pp.23-30
    • /
    • 2024
  • According to the method of settling the construction structure on the ground to keep the structure safe, the ground anchor method is divided into a load-distributing anchor and a general anchor. Recently, the application of load-distributed anchors, which show a large degree of recognition by anchors, is increasing in the field, but the problem of field applicability is also caused. The load-distributed anchor fixes the tensile force to each section of the lecture line and applies it, causing a problem of asymmetric loads in which the maximum tensile force size of each settlement site differs due to the length difference of the anchor body. Therefore, in this study, as a quality management method according to the asymmetric load of anchors, a mono-type load cell that can measure the load for each lecture line of a load-distributed anchor was developed, and the field applicability was analyzed by comparing and analyzing the measurement results of the existing multi-type load cell and mono-type load cell. As a result of the study, the multi-type load cell had no choice but to estimate the working load for each inner body, so it was impossible for the load-distributed anchor to manage it according to the generation of asymmetric loads for each lecture line. However, in the case of a mono-type load cell the load was measured for each inner body and for each lecture line, regardless of ground conditions and construction conditions, and thus the load value was measured for each lecture line, enabling safety management and construction management according to the occurrence of asymmetric loads.

Applying QFD in the Development of Sensible Brassiere for Middle Aged Women (QFD(품질 기능 전개도)를 이용한 중년 여성의 감성 Brassiere 개발)

  • Kim Jeong-hwa;Hong Kyung-hi;Scheurell Diane M.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.12 s.138
    • /
    • pp.1596-1604
    • /
    • 2004
  • Quality Function Deployment(QFD) is a product development tool which ensures that the voice of the customer needs is heard and translated into products. To develop a sensible brassiere for middle-aged women QFD was adopted. In this study the applicability and usefulness of QFD was examined through the engineering design process for a sensible brassiere for middle-aged women. The customer needs for the wear comfort of brassiere was made by one-on-one survey of 100 women who aged 30-40. The customer competitive assessment was generated by wearing tests of 10 commercial brassieres. The subjective assessment was conducted in the enviornmental chamber that was controlled at $28{\pm}1^{\circ}C,\;65{\pm}3\%RH.$ As a results, we developed twenty-one customer needs and corresponding HOWs for the wear comfort of brassiere. The Customer Competitive Assessment was generated by wearing tests of commercial brassiere. The subjective measurement scale and dimension for the evaluation of sensible brassiere were extracted from factor analysis. Four factors were fitting, aesthetic property, pressure sensation, displacement of brassiere due to movement. The most critical design parameter was wire-related property and second one was stretchability of main material of brassiere. Also, wearing comfort of brassiere was affected by the interaction of initial stretchability of wing and support of strap. Engineering design process, QFD was applicable to the development of technical and aesthetic brassieres.

Analysis of Output Constancy Checks Using Process Control Techniques in Linear Accelerators (선형가속기의 출력 특성에 대한 공정능력과 공정가능성을 이용한 통계적 분석)

  • Oh, Se An;Yea, Ji Woon;Kim, Sang Won;Lee, Rena;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.185-192
    • /
    • 2014
  • The purpose of this study is to evaluate the results for the quality assurance through a statistical analysis on the output characteristics of linear accelerators belonging to Yeungnam University Medical Center by using the Shewhart-type chart, Exponentially weighted moving average chart (EWMA) chart, and process capability indices $C_p$ and $C_{pk}$. To achieve this, we used the output values measured using respective treatment devices (21EX, 21EX-S, and Novalis Tx) by medical physicists every month from September, 2012 to April, 2014. The output characteristics of treatment devices followed the IAEA TRS-398 guidelines, and the measurements included photon beams of 6 MV, 10 MV, and 15 MV and electron beams of 4 MeV, 6 MeV, 9 MeV, 12 MeV, 16MeV, and 20 MeV. The statistical analysis was done for the output characteristics measured, and was corrected every month. The width of control limit of weighting factors and measurement values were calculated as ${\lambda}=0.10$ and L=2.703, respectively; and the process capability indices $C_p$ and $C_{pk}$ were greater than or equal to 1 for all energies of the linear accelerators (21EX, 21EX-S, and Novalis Tx). Measured values of output doses with drastic and minor changes were found through the Shewhart-type chart and EWMA chart, respectively. The process capability indices $C_p$ and $C_{pk}$ of the treatment devices in our institution were, respectively, 2.384 and 2.136 for 21EX, 1.917 and 1.682 for 21EX-S, and 2.895 and 2.473 for Novalis Tx, proving that Novalis Tx has the most stable and accurate output characteristics.