• Title/Summary/Keyword: quality measurement

Search Result 4,484, Processing Time 0.031 seconds

Image Quality of Amorphous Selenium DR system using MTF measurement (MTF 측정을 통한 비정질 셀레늄 기반의 디지털 방사선 검출기의 영상 질 평가에 관한 연구)

  • Seok, Dae-Woo;Park, Ji-Koon;Choi, Jang-Yong;Nam, Sang-Hee;Kang, Shin-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.384-387
    • /
    • 2003
  • In this paper, the evaluation of image quality was performed for digital radiography which is developing in using amorphous selenium as a photoconductor material for the purpose of offering basic research data and measurement technique about Medical Imaging Quality. So Modulation Transfer Function as a main factor of imaging quality evaluation was investigated by slit method. For measurement of MTF, Nuclear associates. 07-624 Slit camera image was obtained to study the variation of MTF corresponding to changing spatial frequency. And Presampling MTF was estimated by slit camera image with $10\;{\mu}m$ width at Digital Radiography. In this study, the obtained data demonstrates that the clinical value of a direct conversion type digital radiation detector using the amorphous selenium, which is being developed by domestic technology.

  • PDF

Airborne Measurements of Ozone and Its Precursors over Yeosu-Gwangyang Industrial Areas in the Southern Coast of Korea

  • Kim, So-Young;Seo, Seok-Jun;Park, Hyun-Ju;Son, Jung-Seok;Park, Ji-Hoon;Kim, Jong-Choon
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.3
    • /
    • pp.139-151
    • /
    • 2013
  • The purpose of this study is to understand distributional characteristics in the atmospheric concentrations of $O_3$ and its precursors based on data taken at the southern Korean coast. The average $O_3$ concentration in the high altitude was found to range from 32.3 to 90.8 ppb with a maximum concentration of 132 ppb. The ambient $O_3$ concentration was high at altitudes of 1000 m and 500 m above the southern sea near Gwangyang Bay and an industrial area containing emission sources. The daily mean concentrations of $NO_y$ and CO were 6.7-24.2 ppb and 0.152-0.487 ppm, respectively. During the aerial measurement period, the highest mean concentration of $O_3$ was observed on June 1. The aerial measurement results showed that the maximum ozone concentration was observed to be 132 ppb in the high altitude the southernmost part of Yeosu. The measurement of vertical wind fields in the air indicated that $O_3$ formed in the southernmost part of Yeosu was transported by strong southwesterly winds to the northeast of Gwangyang Bay. This led to a ground $O_3$ concentration of over 100 ppb in Jinju, the northeastern part of Gwangyang Bay. On August 9, when the maximum $O_3$ concentration was 50 ppb, the measurement results showed that $O_3$ concentrations were relatively low compared to other days. In particular, low $NO_2$ and TVOC concentrations were observed, both of which serve to form $O_3$ in photochemical reactions.

A Study on Developing a Service Quality Evaluation Model for Library Mobile Service (도서관 모바일 서비스 품질 평가 모형 개발에 관한 연구)

  • Han, Seunghee
    • Journal of the Korean Society for information Management
    • /
    • v.34 no.4
    • /
    • pp.273-292
    • /
    • 2017
  • This paper aims to develop an evaluation model for library mobile services in terms of service quality. First, a literature review of the service quality evaluation model and the mobile library service evaluation was conducted. Then, based on the analysis, the evaluation model consisting of 4 quality dimensions, 10 quality factors, 39 quality measurement items was developed. Delphi method was applied to verify the validity of the model. Finally, a final model consisting of 4 quality dimensions, 9 quality factors, and 37 quality measurement items was derived. The evaluation model proposed in this study can be used as a measure of library mobile service quality and can be used as a guideline for improvement of library mobile service.

The Current State of and Barriers to Quality Measurement, and Quality Managers' Reported Evaluation on Quality Indicators in Korea (국내 질 향상부서 중심의 질 지표 측정 현황, 장애요인과 평가)

  • Hwang Jee-In
    • Health Policy and Management
    • /
    • v.15 no.4
    • /
    • pp.26-45
    • /
    • 2005
  • The purposes of this study were to Identify the .level of measurement on quality Indicators and evaluate the existing indicators in order to determine the priority of quality indicators' application in Korean general hospitals. A survey was conducted using a questionnaire. The subjects were quality managers working at general hospital having over 300 beds. The criteria were relevance, reliability, precision, impact, application, and preference to evaluate quality indicators. According to these six criteria, each indicator was evaluated on a five point scale(5: excellent, 1: poor). The response rate was $40.4\%$. The hospitals have monitored the average of 3.8 indicators(median 4). The indicators such as return to operating room, unplanned readmission, cancellation of booked operations, death, hospital infection, cesarean section rate, volume per disease or procedure, readmission, re-operation, blood transfusion, and post-procedural complications were frequently measured. The top ten quality indicators in the evaluation by its relevance, validity, reliability, impact, preference and application were decubitus ulcer, clean wound infection, fall, unplanned return to operation room, transfusion reactions, foreign body left In during procedure, unplanned readmission, wound infection after contaminated surgery, postoperative hemorrhage/hematoma, and cesarean section rate in order. The high priority quality indicators frequently measured could be used as primary national indicators. Standardized guidelines about monitoring indicators and the utilization will preliminarily be needed to compare and reuse the data for various purposes and improve the quality of care continuously.

Digital Image Quality Assessment Based on Standard Normal Deviation

  • Park, Hyung-Ju;Har, Dong-Hwan
    • International Journal of Contents
    • /
    • v.11 no.2
    • /
    • pp.20-30
    • /
    • 2015
  • We propose a new method that specifies objective image quality factors by evaluating an image quality measurement model using random images. In other words, No-Reference variables are used to evaluate the quality of an original image without using any reference for comparison. 1000 portrait images were collected from a web gallery with votes constituting over 30 recommendation values. The bottom-up data collecting process was used to calculate the following image quality factors: total range, average, standard deviation, normalized distribution, z-score, preference percentage. A final grade is awarded out of 100 points, and this method ranks and grades the final estimated image quality preference in terms of total image quality factors. The results of the proposed image quality evaluation model consist of the specific dynamic range, skin tone R, G, B, L, A, B, and RSC contrast. We can present the total for the expected preference points as the average of the objective image qualities. Our proposed image quality evaluation model can measure the preferences for an actual image using a statistical analysis. The results indicate that this is a practical image quality measurement model that can extract a subject's preferred image quality.

Development of Software Quality Assessment Tool (소프트웨어 품질평가 도구(ESCORT)의 설계 및 구현)

  • Yang, Hae-Sul;Gwon, Gi-Hyeon;Lee, Ha-Yong;Jo, Yeong-Sik;Lee, Yong-Geun;Park, Jeong-Ho;Heo, Tae-Gyeong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.2 no.2
    • /
    • pp.185-198
    • /
    • 1995
  • The development of automated quality evaluation tool is desperately needed to decrease the cost of maintenance, to measure quality of source program in developing course for the purpose of developing high quality software. Main goal in this paper is to develop the automated tool for software quality evaluation related with high quality and high reliability of software. In this paper, we proposed the four software quality model to evaluate software quality; functional -size model, understandability model, complexity model and object-oriented model. Also, we made a scanner and a parser to analyze the c and C++ source program and to produce the metrics and function value. The measurement value is statistically analyzed for the distribution of the measurement value. we can extracted the characteristics of measurement value and this one is assisted to make scores of software quality evaluation. Finally, we made a software quality evaluation tool to support software evaluation activities.

  • PDF

Evaluation of Degree of Compaction of Railroad Trackbed Fills Using Elastic Wave Velocities (탄성파 속도를 이용한 철도 토공노반의 다짐도 평가)

  • Kim, Hak-Sung;Jung, Young-Hoon;Gang, Dong-Yeob;Lee, Seong-Hyeok
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1650-1658
    • /
    • 2011
  • The quality control of compaction fills has been commonly performed via the field density measurement and plate load tests. However, the engineer frequently encounters difficulties in actually controling the quality due to the uncertainty in the field density measurement as well as the plate load tests. To overcome these difficulties, Park et al. (2009) proposed an alternative quality control method based on the measurement of the compressive wave velocities. In this study, the compressive wave velocities measured in the full-scale model test site were analyzed. Direct arrive seismic tests were performed after the completion of each trackbed layer. To identify a relationship between elastic wave velocities and degree of compaction, laboratory compaction tests were conducted.

  • PDF

International Standards trend on Hydrogen fuel quality (ISO/TC197/WG12의 수소품질 국제표준화 동향)

  • Cho, Sung-Kook;Cho, Chang-Ae;Lee, Taeck-Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.739-743
    • /
    • 2009
  • Japan is leading standards for the hydrogen fuel quality on the PEMFC(Proton Exchange Membrane Fuel Cell) vehicle at ISO/TC197/WG12. However, it has many problems to solve the standard of measurement and the test method. because the standard of measurement which was proposed in Japan is too high to reach the technique for many countries. it might not control standards for the hydrogen fuel quality on the PEMFC vehicle in Korea. So we need to develop the study of standards and the technique of measurement continuously for the International Standards Meeting.

  • PDF

An Implementation of Traffic Management System for Internet QoS Guarantee (인터넷 품질 수준 측정을 위한 품질 관리시스템 구현)

  • 김진규;이순흠
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.3
    • /
    • pp.399-407
    • /
    • 2004
  • As the number of IP-users are increasing, it is getting so important for service providers to check the state of the current Internet and their service quality by measuring the traffic quality. We describe a general concept of measurement architecture and internet QoS (Quality of Service) parameters, and we review measurement tools. To meet these requirements, we design and implement the Internet traffic management system.

  • PDF

Power Quality Measurement Using TMS320C6701 Processor (TMS320C6701 프로세서를 이용한 전력 품질 측정)

  • Shin, Myong-Jun;Son, Young-Ik;Kim, Kab-Il
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.50-52
    • /
    • 2005
  • Research interests in PQ(Power Quality) measurement and monitoring system have been increased. This paper describes an experimental result for monitoring system that monitors power quality and undesirable accidents when distributed generations are connected to the power grid. Prior to develop a physical monitoring system for distributed generation applications, we constitute a mesuring system for the general PQ factors. In this paper, an approach to how to measure the PQ elements is presented by using TMS320C6701 processor. Simulation results using the PSCAD and the power system simulation equipment Dobel have verified the proposed measurement system.

  • PDF