• Title/Summary/Keyword: quality control tests

Search Result 546, Processing Time 0.026 seconds

Development and Validation of Crocidolite Quality Control Samples for Proficiency Analytical Testing (청석면 분석 정도관리용 표준시료 개발 및 평가)

  • Lee, Ji-Hyun;Kim, Eun-Young;Noh, Su-Jin;Park, Yong-Jin;Jeong, Jee-Yeon
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.1
    • /
    • pp.57-63
    • /
    • 2011
  • Crocidolite quality control (QC) sampling created by the wet generation method has been validated by validation tests such as the accuracy, precision, and storage tests. For this study we designed and developed a manufacturing apparatus and standard operating procedure for making these QC samples. The most important step in the procedure of making QC samples was the stage eliminating static electricity in asbestos fibers. This static electricity hampers the fibers clog functioning. In accuracy and precision tests by phase contrast microscopy analysis, the difference between the reference values and the studied values was at maximum 17.8%. This satisfies the AIHA proficiency analytical test criteria for asbestos. We could confirm the nearly even distribution of crocidolite fibers on the membrane filter. Also, there was no loss of fibers in the storage test after the one month.

A Case Study on the Quality Control of Soil-Bentonite Admixed Liner (흙-벤토나이트 혼합 차수재의 품질관리 사례연구)

  • 정하익;이용수;홍승서;정길수;이회준
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.497-504
    • /
    • 1999
  • This study presents the physical and engineering characteristics of soil-bentonite admixed liner in I landfill. Main focus was the hydraulic conductivity of compacted soil-bentonite admixed and mechanisms governing low permeable properties of the admixed liner. Laboratory and field tests such as compaction, hydraulic conductivity, density, water content for the soil-bentonite admixed liner were carried out. Quality control criteria for the best construction of the soil-bentonite admixed liner was suggested through laboratory and field test results.

  • PDF

Use of the Linear Placement Statistics for the Parallelism of Two Regression Lines

  • Song, Moon Sup;Park, Hong-Nai;Lee, Kay O;Park, Byeong Uk;Shin, Bong Sup
    • Journal of Korean Society for Quality Management
    • /
    • v.20 no.2
    • /
    • pp.67-75
    • /
    • 1992
  • In this paper we propose a class of tests for the parallelism of two regression lines based on linear placement statistics. The results of a small-sample Monte Carlo study show that the proposed tests are reasonably good in level control and powers.

  • PDF

Computer Program for Quality Control of Ready Mixed Concrete (레디믹스트 콘크리트의 품질관리 프로그램 개발)

  • 최재진;박원태
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.1
    • /
    • pp.20-26
    • /
    • 2002
  • To make practical application of mixing test results to concrete mix design, experimental tests of concrete were done and the relationship between cement-water ratio and compressive strength of concrete was obtained. A computer program which can be used for data base of air content, slump and compressive strength test results was developed. The program draws $\bar{X}$-R or X-Rs control charts and has data sheets for arrangement of material test results. The computer program also helps calculation of concrete mix proportions for mixing tests and contains dictionary of concrete technical terms.

  • PDF

Quality Control Tests and Acceptance Criteria of Diagnostic Radiopharmaceuticals (진단용 방사성의약품의 품질관리시험 및 기준)

  • Park, Jun Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • Radiopharmaceuticals are drugs that contain radioisotopes and are used in the diagnosis, treatment, or investigation of diseases. Radiopharmaceuticals must be manufactured in compliance with good manufacturing practice regulations and subjected to quality control before they are administered to patients to ensure the safety of the drug. Radiopharmaceuticals for administration to humans need to be sterile and pyrogen-free. Hence, sterility tests and membrane filter integrity tests are carried out to confirm the asepticity of the finished drug product, and a bacterial endotoxin test conducted to assess contamination, if any, by pyrogens. The physical appearance and the absence of foreign insoluble substances should be confirmed by a visual inspection. The chemical purity, residual solvents, and pH should be evaluated because residual by-products and impurities in the finished product can be harmful to patients. The half-life, radiochemical purity, radionuclidic purity, and strength need to be assessed by analyzing the radiation emitted from radiopharmaceuticals to verify that the radioisotope contents are properly labeled on pharmaceuticals. Radiopharmaceuticals always carry the risk of radiation exposure. Therefore, the time taken for quality control tests should be minimized and care should be taken to prevent radiation exposure during handling. This review discusses the quality control procedures and acceptance criteria for a diagnostic radiopharmaceutical.

INTRODUCTION OF DATELLITE COMMUNICATION SYSTEM TEST LANGUNGE

  • Ahn, Dong-Hyun;Jung, Won-Chan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.229-231
    • /
    • 1994
  • For the effective use of satellite communication transponder, tests for the payload system such as IOT(In-Orbit Test), RPM(Routine Payload Monitoring), CSM(Communicatios System Monitoring), and REV(Remote Earth-Station Verification) have to be conducted. Those tests are used in order to verify the condition and generic design of the satellite, to provide a database for operational calculations, and to maintain the quality of communication services. As the satellite communication system gets with wider expansion with higher complexity of operation, tests for the communication system also need more complex operation that usesophisticated computer-controlled measuring system. For and C language based measurement functions, which uses GPIB protocol and SCPI commands. But SICL requires knowledge of BASIC and C language as well as GPIB and SCPL system. This paper introduces a new language called CALSTEP-Control and Access Language for the Systems of Test Equipment and Payload. This language is designed for the operator to perform the tests for the satellite communication system without any special knowledge that is mentioned above. This language has very limited number of commands which are to be used to control the payload system and test equipments to perform IOT and CSM, and those commands are very readable and easy to understand, so an operator without any knowledge of BASIC and C programming language, or SICL and SCPI command can use it.

  • PDF

Response Calibration for Bridges based on Statistical Quality Control Chart (통계적 품질 관리도에 기초한 교량의 응답 보정)

  • Hwang, Jin Ha;An, Seoung Su;Kim, Ju Han
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.61-70
    • /
    • 2013
  • This paper presents the response calibration method based on quality control range, which is established from the concept and method of statistical quality control for natural frequency ratio and response ratio. To this end, statistical analysis including descriptive statistics analysis, normality test, ANOVA were performed for response characteristics obtained from loading tests and structural analysis for more than hundred and thirty well-conditioned bridges. Suggested method is based on real structural integrity evaluation case studies and statistical quality control approach, in this respect it is expected to provide scientific criteria and systematic procedure for response calibration and load carrying capacity assessment.

Effect of Home Care Service on the Quality of Life in Patients with Gynecological Cancer

  • Aktas, Demet;Terzioglu, Fusun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.4089-4094
    • /
    • 2015
  • The purpose of the research was to determine the effect of home care service on the quality of life in patients with gynecological cancer. This randomized case control study was carried out in a womans hospital between September 2011 and February 2012. Women undergoing gynecological cancer treatment were separated into intervention and control groups, of 35 patients each. The intervention group was provided with nursing care service through hospital and home visits ($1^{st}$, $12^{th}$ weeks) within the framework of a specifically developed nursing care plan. The control group was monitored without any intervention through the hospital routine protocols ($1^{st}$, $12^{th}$ weeks). Data were collected using An Interview Form, Home Visit Monitoring Form and Quality of Life Scale/Cancer Survivors. Effects of home care service on the quality of life in gynecological cancer patients were investigated using chi-square tests, McNemar's test, independent t-test and ANOVA. This study found that the intervention group receiving home care service had a moderately high quality of life (average mean: $6.01{\pm}0.64$), while the control group had comparatively lower quality (average mean: $4.35{\pm}0.79$) within the 12 week post-discharge period (p<0.05). This study found home care services to be efficient in improving the quality of life in patients with gynecological cancer.

A Clinical Trial on the Method of Urine Sampling for Urinalysis (소변검사의 검체 채취 방법에 관한 임상실험연구)

  • An Hae-Sung;Lee Sung-Eun;Park Hyun-Ok
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.2 no.2
    • /
    • pp.131-137
    • /
    • 1995
  • Improving validity and reliability is the important components of clinical laboratory tests. And the quality control of the test should be started with the accurate collection of specimen. Urinalysis is one of the useful and common tests in diseases diagnosis and determining the process of medical treatment. Since urinalysis is requested routinely in hospital setting, the importance of the quality control for urine specimen is often ignored. To improve the validity of urinalysis, a clinical trial was done on the method of collecting urine specimen. The result was as follows : 1. The rate of presumtive UTI(urinary tract infection) was decreased in 21.6% with experiment method for collecting urine specimen. 2. The rate of presumtive UTI in female patients was decreased in 43.2% with the experiment method. 3. The rate of negative urine culture was decreased in 6.6% with the experiment method.

  • PDF

Relationship Between Antigravity Control and Postural Control in Normal Children (정상 아동의 반중력 조절과 자세 조절간의 상관 관계)

  • Cho, Jeong-Ar;Choi, Sun-Hee;Kim, Jung-Min
    • Physical Therapy Korea
    • /
    • v.1 no.1
    • /
    • pp.35-46
    • /
    • 1994
  • The purposes of this study were 1) to determine the relationship between antigravity control(supine flexion and prone extension) and postural control(static and dynamic balance) by age, 2) to determine the quality of antigravity and postural control, and 3) to determine whether sex difference correlates with differences in antigravity and postural control in young normal children. We tested 120 children aged 4 to 7 years. The study results showed a significant relationship between antigravity and postural control by age. Quality scale measurements(r=0.90) indicated that the children in this study had not yet developed full antigravity or postural control. The study results revealed differences between sexes(f>m in 5 of 7 tests) and a significant relationship by age in antigravity and postural control.

  • PDF