• Title/Summary/Keyword: quality coefficient

Search Result 2,414, Processing Time 0.038 seconds

Developing APC for Weighting Quality Attributes (품질 속성의 가중치 선정을 위한 APC에 관한 연구)

  • Song, Hae Geun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.36 no.3
    • /
    • pp.8-16
    • /
    • 2013
  • Determining relative importance among many quality attributes under financial constraints is an important task. The weighted value of an attribute particularly in QFD, will influence on engineering characteristics and this will eventually influence the whole manufacturing process such as parts deployment, process planning, and production planning. Several scholars have suggested weighting formulas using CSC (Customer Satisfaction Coefficient) in the Kano model. However, previous research shows that the validity of the CSC approaches has not been proved systematically. The aim of the present study is to address drawbacks of CSC and to develop APC (Average Potential Coefficient), a new approach for weighting of quality attributes. For this, the current study investigated 33 quality attributes of e-learning and conducted a survey of 375 university students for the results of APC, the Kano model, and the direct importance of the quality attributes. The results show that the proposed APC is better than other approaches based on the correlation analysis with the results of direct importance. An analysis of e-leaning's quality perceptions using the Kano model and suggestions for improving e-learning's service quality are also included in this study.

The Effect on Visibility of the Chemical Composition of Fine Particles in the Gwangju Area (광주지역 미세먼지의 화학적 조성이 시정에 미치는 영향에 관한 연구)

  • Jung, Sun-A;Lim, Cheol-Soo;Jo, Mi-Ra;Lee, Sang-Bo;Kim, Jung-Soo;Shin, Eun-Sang
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.1
    • /
    • pp.1-14
    • /
    • 2018
  • Objectives: The purpose of this study is to investigate the main cause of visibility impairment by analyzing the contributions of the light extinction coefficient of major air pollution components and the change of the light extinction coefficient by relative humidity. Methods: The characteristics of the light extinction coefficient calculated by the photochemical method using fine particle component data measured in 2015 in the Gwangju area were examined. Results: The extinction efficiency per unit mass of $PM_{2.5}$ particles was $4.5m^2/g$ and that of $PM_{10-2.5}$ particles was $0.6m^2/g$. This difference indicates that most of the visibility impairment in Gwangju was caused by $PM_{2.5}$ particles. When visibility was poor, the contribution of ammonium sulphate and ammonium nitrate was significantly increased. Relative humidity was also a major cause of visibility decay. The influx of air currents in Gwangju was mostly caused by the long distance movement of pollutants emitted from the eastern part of China. Ammonium sulphate and ammonium nitrate, which are hygroscopic secondary contaminants, were the main causative agents of visibility impairment. Conclusions: Ammonium sulphate and ammonium nitrate were the main causative agents of visibility impairment in Gwangju. The influx of air currents in Gwangju was mostly caused by the long distance movement of pollutants emitted from the eastern part of China.

Analysis of Correlation Relationship for Flow and Water Quality at Up and Down Streams (수계 상하류의 유량 및 수질 상관관계 분석)

  • Chang, In-Soo;Jung, Jin-Kyeng;Park, Ki-Bum
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.771-778
    • /
    • 2010
  • The prediction of discharge is very important in water resources management and plan. In this study, we have analyzed discharge data of site at up and down stream in watershed. In order to forecast discharge the regression equations were developed by measuring flow data. Also, to forecast the change of water quality followed by change of inflow the correlation relationship between inflow of the Youngchun site and the Chunhju dam was shown as very high. The forecast of inflow at the Chungju dam would be possible through flow analysis of the Youngchun site. And, it is possible to forecast water quality by flow analysis because the correlation relationship of SS and turbidity followed by change of flow for each station of investigation was very high.

Study of Leaf Quality Coefficient on Korea Flue-cured Tobacco Leaves According to Chemical Variables. (이화학적인 방법에 의한 황색종 잎담배 품질의 계수)

  • 김신일;김찬호
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.6 no.1
    • /
    • pp.63-72
    • /
    • 1984
  • 1 . Some components associated with mildness, taste, and aroma were set. It was supposed that the three factors contribute to equally the evaluation of tobacco quality. Following equation of quality index was provide. $Q_{pr}\;=\;=0.815\;f_1+8.224f_2+1.858f_3$ where $f_1$ = Reducing sugar (%)/cellulose (%) $f_2=\frac{1}{Total N (%) + Protein (%) + Citric acid (%)}$ $f_3$=Key aromatic compounds ($mg/10g$) 2. The coefficient of correlation between the grades by visible criteria and the values of the quality index for Korean flue-cured tobacco was $\tau$=-0.689 (n=29)

  • PDF

Boiling Heat Transfer Characteristics of R-290 in Horizontal Minichannel (수평미세관내 R-290의 비등열전달 특성)

  • Choi, Kwang-Il;Pamitran, A.S.;Oh, Jong-Taek
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.68-73
    • /
    • 2006
  • The present paper deals with an experimental study of boiling heat transfer characteristics of R-290, and is focused on pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal smooth minichannel with inner diameter of 3.0 mm and length of 2000 mm. The direct heating method applied for supplying heat to the refrigerant where the test tube was uniformly heated by electric current which was applied to the tube wall. The experiments were conducted with R-290 with purity of 99.99% at saturation temperature of 0 to $10^{\circ}C$. The range of mass flux is $50{\sim}250kg/m^2s$ and heat flux is $5{\sim}20kW/m^2$. The heat transfer coefficients of R-290 increases with increasing mass flux and saturation temperature, wherein the effect of mass flux is higher than that of the saturation temperature, whereas the heat flux has a low effect on increasing heat transfer coefficient. The significant effect of mass flux on heat transfer coefficient is shown at high quality, the effect of heat flux on heat transfer coefficient at low quality shows a domination of nucleate boiling contribution. The heat transfer coefficient of the experimental result was compared with six existing heat transfer coefficient correlation. Zang et al.'s correlation(2004) gave the best prediction of heat transfer coefficient.

  • PDF

Evaluation of Lead levels in Airborne by a portable X-Ray Fluorescence Instrument (휴대용 X-Ray 형광기기(XRF)를 이용한 공기중 납농도 평가)

  • Ahn, Kyu Dong;Lee, Jong Chun;Cho, Kwang Sung;Kim, Nam Su;Kim, Jin Ho;Lee, Sung Soo;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.235-240
    • /
    • 2001
  • This study was performed to compare the lead levels of 20 quality control standard samples(KOSHA:18-2000) and 72 field samples in lead-acid battery manufacturing plant between ICP and portable-XRF methods. 1. While the proficiencies of 20 quality control standard samples by ICP were 100%, those of analytic result values by XRF were 75%. 2. The correlation coefficient(r) between the reference values for quality control (REF) and the analytic result values by ICP (ICP) was 1.0(p<0.05), and simple linear regression equation and the coefficient(R2) were REF = -0.0009 + 1.016 ICP and 0.9997, respectively. 3. The correlation coefficient(r) between the analytic result values of quality control standard samples by ICP (ICP) and by XRF (XRF) was 0.975(p<0.05), and simple linear regression equation and the coefficient(R2) were ICP = -0.0003 + 1.002 XRF and 0.950, respectively. 4. The correlation coefficient(r) between the analytic result values for lead samples of a lead-acid battery manufacturing plant by ICP (ICP) and by XRF (XRF) was 0.993(p<0.05), and simple linear regression equation and the coefficient(R2) were ICP = -2.058 + 0.996 XRF and 0.987, respectively. 5. While the frequency distributions of XRF /ICP(Ratio) for each ICP concentration levels in a lead-acid battery manufacturing plant revealed high proportion in ratio range of 0.876-1.125 than in ration range of 1.126-1.375. Also, ICP concentration level in ration range of 0.786-1.125 was increased with increase of frequency distribution of XRF/ICP. 6. The limit of detection of XRF on lead was determined to be $6.11{\mu}g$/filter The data presented in this study indicated that relationship for lead level of quality control samples and field samples in a lead -acid battery manufacturing plant by ICP and portable-XRF methods was proved. The practicing industrial hygienist can use portable-XRF to produce a rapid on-site determination of lead exposure that can immediately becommunicated to workers and help identify appropriate levels of personal protection.

  • PDF

Analysis of Service Quality Attributes in the CVS Premium Packed Meal Products Based on the Kano Model (Kano 모형을 이용한 편의점 프리미엄 도시락의 서비스품질 속성 분석)

  • Baek, Seung Hee;Lee, Bumjun
    • Journal of the Korean Society of Food Culture
    • /
    • v.34 no.3
    • /
    • pp.308-315
    • /
    • 2019
  • This study examined the service quality attributes of the CVS (Convenient Store) packed meal products by applying the Kano model. The main survey was conducted by a research company using an online survey in the form of a self-administered questionnaire. The 499 samples were limited to customers who had experienced CVS packed meal products within the last months. A total of 14 service quality attributes of the CVS premium packed meal products were categorized as four attractive qualities, one must-be quality, three one-dimensional qualities and six indifferent qualities. According to the Better and Worse quotient designed by Timko, 'coupon and sales promotion event', 'healthy menu configuration', and 'balanced nutrition' had higher levels of the Better coefficient. On the other hand, 'hygiene and cleanliness', 'the delicious food', and 'fresh ingredients' showed a higher Worse coefficient. The results also suggest that each service quality attribute is not a single dimension but a complex attribute. As a result, this research suggests that marketing practitioners should immediately identify consumer's changing perception of quality to attract new customers and prevent existing customers from leaving in the CVS premium packed meal products segment.

Study on Estimation and Application of Discharge Coefficient about Nonpoint Source Pollutants using Watershed Model (유역모형을 이용한 유량조건별 배출계수 산정 및 활용방안 연구)

  • Hwang, Ha-Sun;Rhee, Han-Pil;Park, Jihyung;Kim, Yong-Seok;Lee, Sung-Jun;Ahn, Ki Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.6
    • /
    • pp.653-664
    • /
    • 2015
  • TPLMS (Total water pollutant load management system) that is the most powerful water-quality protection program have been implemented since 2004. In the implementation of TPLMS, target water-quality and permissible discharged load from each unit watershed can be decided by water-quality modeling. And NPS (Non-point sources) discharge coefficients associated with certain (standard) flow are used on estimation of input data for model. National Institute of Environmental Research (NIER) recommend NPS discharge coefficients as 0.15 (Q275) and 0.50 (Q185) in common for whole watershed in Korea. But, uniform coefficient is difficult to reflect various NPS characteristics of individual watershed. Monthly NPS discharge coefficients were predicted and estimated using surface flow and water-quality from HSPF watershed model in this study. Those coefficients were plotted in flow duration curve of study area (Palger stream and Geumho C watershed) with monthly average flow. Linear regression analysis was performed about NPS discharge coefficients of BOD, T-N and T-P associated with flow, and R2 of regression were distributed in 0.893~0.930 (Palger stream) and 0.939~0.959 (Geumho C). NPS Discharge coefficient through regression can be estimated flexibly according to flow, and be considered characteristics of watershed with watershed model.

Study on Evaporation Heat Transfer of R-l34a, R-407C, and R-410A in the Oblong Shell and Plate Heat Exchanger (오블롱 셀 플레이트 열교환기에서의 R-l34a, R-407C, R-410A의 증발 열전달에 관한 실험적 연구)

  • 박재홍;김영수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.845-854
    • /
    • 2004
  • The evaporation heat transfer coefficient for R-l34a, R-407C (a mixture of 23wt% R-32, 25 wt% R-125, and 52 wt% R-l34a) and R-410A (a mixture of 50 wt% R-32 and 50 wt% R-125) flowing in the oblong shell and plate heat exchanger were investigated experimentally in this study. Four vertical counterflow channels were formed in the exchanger by four plates of commercial geometry with a corrugated sinusoid shape of a chevron angle of 45 degree. The effects of the mean vapor quality, mass flux, heat flux, and saturation temperature of different refrigerants on the evaporation heat transfer were explored in detail. Similar to the case of a Plate heat exchanger, even at a very low Reynolds number, the flow in the oblong shell and plate heat exchanger remains turbulent. It is found that the evaporation heat transfer coefficient in the plates is much higher than that in circular pipes. The present data show that the evaporation heat transfer coefficients of all refrigerants increase with the vapor quality. At a higher mass flux h, is higher than for the entire range of the vapor quality. Raising the imposed wall heat flux was found to slightly improve h$_{r}$, while h$_{r}$ is found to be lower at a higher refrigerant saturation temperature. A comparison of the performance of the various refrigerants reveals that R-410A has the highest heat transfer performance followed by R-l34a, and R-407C had the lowest performance of the refrigerants tested. Based on the present data, empirical correlations of the evaporation heat transfer coefficient were proposed.sed.

Development of prediction models of chlorine bulk decay coefficient by rechlorination in water distribution network (상수도 공급과정 중 재염소 투입에 따른 잔류염소농도 수체감소계수 예측모델 개발)

  • Jeong, Bobae;Kim, Kibum;Seo, Jeewon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.1
    • /
    • pp.17-29
    • /
    • 2019
  • This study developed prediction models of chlorine bulk decay coefficient by each condition of water quality, measuring chlorine bulk decay coefficients of the water and water quality by water purification processes. The second-reaction order of chlorine were selected as the optimal reaction order of research area because the decay of chlorine was best represented. Chlorine bulk decay coefficients of the water in conventional processes, advanced processes before rechlorination was respectively $5.9072(mg/L)^{-1}d^{-1}$ and $3.3974(mg/L)^{-1}d^{-1}$, and $1.2522(mg/L)^{-1}d^{-1}$ and $1.1998(mg/L)^{-1}d^{-1}$ after rechlorination. As a result, the reduction of organic material concentration during the retention time has greatly changed the chlorine bulk decay coefficient. All the coefficients of determination were higher than 0.8 in the developed models of the chlorine bulk decay coefficient, considering the drawn chlorine bulk decay coefficient and several parameters of water quality and statistically significant. Thus, it was judged that models that could express the actual values, properly were developed. In the meantime, the chlorine bulk decay coefficient was in proportion to the initial residual chlorine concentration and the concentration of rechlorination; however, it may greatly vary depending on rechlorination. Thus, it is judged that it is necessary to set a plan for the management of residual chlorine concentration after experimentally assessing this change, utilizing the methodology proposed in this study in the actual fields. The prediction models in this study would simulate the reduction of residual chlorine concentration according to the conditions of the operation of water purification plants and the introduction of rechlorination facilities, more reasonably considering water purification process and the time of chlorination. In addition, utilizing the prediction models, the reduction of residual chlorine concentration in the supply areas can be predicted, and it is judged that this can be utilized in setting plans for the management of residual chlorine concentration.