• Title/Summary/Keyword: pyramid type

Search Result 73, Processing Time 0.027 seconds

Analysis of Ship Hull Plate Bending By Roll Bending Machine (Roll bending machine에 의한 선체외판의 곡면가공 해석)

  • Kim, You-Il;Shin, Jong-Gye;Lee, Jang-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.4
    • /
    • pp.142-149
    • /
    • 1996
  • Pyramid type three roll bending machines are widely used in roll-bending process to produce singly curved plate. In forming singly curved plate, controlling the vertical displacement of the center roller is most important to acquire the shape required and automation system of the process. In this paper roller bending process is modeled as an elastic-plastic phenomenon and analyzed using beam theory and finite element method. In finite element analysis the workpiece is modeled by using beam elements and plane strain elements respectively. Through the analyses vertical center roller displacement is obtained to get constant curvature distribution along arc length. The relationship between center roller displacement and curvature in steady state as well as residual stress and strain along plate thickness direction are calculated through finite element analysis.

  • PDF

Ectomycorrhizal Roots Collected from the Bases of the four Edible Basidiocarps Around Mt. Wol Ak

  • Lee, Sang-Sun;Kim, Dong-Hun;Chung, Hung-Chae
    • Mycobiology
    • /
    • v.28 no.1
    • /
    • pp.27-32
    • /
    • 2000
  • The ectomycorrhizal roots were collected from the soils around the bases of basidiocarps of the four edible mushrooms in the stands of Pinus densiflora or Querus acutissima communities (Mt. Wol-Ak in Eastern Chung-Puk): The basidiocarps of Tricholoma matsutake (TM), Sarcodon asparatus (SA), S. imbricatum (SI), and Polyozellus multiplex (PM) are usually collected. The ectomycorrhizal roots of TM, PM and SI were related to the roots of P. densiflora, but the other to the roots of Q. acutissima in Korea. Particularly, the basidiocarps of PM were collected in the mixed stand of both P. densiflora and Q. acutissima. The morphologies of the ectomycorrhizal roots were observed to be the yellowish brown coral (dichromatous) or pyramid types in the roots of the pine, but dark brown un-branched sticks (roots) in the ends of ectomycorrhizal roots of Querus plants. The un-branched roots were covered with the dark mycelia (rhizomorph) around them. Therefore, the ectomyorrhizal roots of PM were observed to have two kinds of types; The single blackish un-branched roots were observed to be attached to the yellowish coral type roots. The bundles of TM mycelia were filled with cortical cells (in the roots of P. densiflora), but the mycelia of the other fungi (Aphylloporales) were massed between the cortical cells of P. densiflora or Q. acutissima. Their anatomical and gross features were considered to be simailar but very important in the ectomycorrhizal roots for these edible mushrooms.

  • PDF

PIXEL-BASED CORRECTION METHOD FOR GAFCHROMIC®EBT FILM DOSIMETRY

  • Jeong, Hae-Sun;Han, Young-Yih;Kum, O-Yeon;Kim, Chan-Hyeong;Ju, Sang-Gyu;Shin, Jung-Suk;Kim, Jin-Sung;Park, Joo-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.670-679
    • /
    • 2010
  • In this paper, a new approach using a pixel-based correction method was developed to fix the non-uniform responses of flat-bed type scanners used for radiochromic film dosimetry. In order to validate the method's performance, two cases were tested: the first consisted of simple dose distributions delivered by a single port; the second was a complicated dose distribution composed of multiple beams. In the case of the simple individual dose condition, ten different doses, from 8.3 cGy to 307.1 cGy, were measured, horizontal profiles were analyzed using the pixel-based correcton method and compared with results measured by an ionization chamber and results corrected using the existing correction method. A complicated inverse pyramid dose distribution was made by piling up four different field shapes, which were measured with GAFCHROMIC$^{(R)}$EBT film and compared with the Monte Carlo calculation; as well as the dose distribution corrected using a conventional method. The results showed that a pixel-based correction method reduced dose difference from the reference measurement down to 1% in the flat dose distribution region or 2 mm in a steep dose gradient region compared to the reference data, which were ionization chamber measurement data for simple cases and the MC computed data for the complicated case, with an exception for very low doses of less than about 10 cGy in the simple case. Therefore, the pixel-based scanner correction method is expected to enhance the accuracy of GAFCHROMIC$^{(R)}$EBT film dosimetry, which is a widely used tool for two-dimensional dosimetry.

THE STUDY ON THE NOISE IN THE VESSEL -Effect of the Noise Control by the Noise Arresting Rooms- (선박소음에 관한 연구 -방음실에 의한 소음제어효과실험-)

  • PARK Jung-Hee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.3
    • /
    • pp.215-221
    • /
    • 1976
  • In this study, noise arresting effect of the noise control room from the transmission of surrounding noise was tested when the packing noise control rooms were set up in the test room in which the prerecorded noise from an engine room was reradiated at the same level as the original pressure. The inner space of control room A is $3.389m^3(1.19\times1.19\times2.14m)$ having walls furnished with plywood board 9mm in thickness and noise control room door$(60\times45cm) $ and illumination lamp are placed. In case of the control room B, noise absorption board(10mm fiber board which holds the corntype concavity with diameter of 5mm, depth 5mm, space 15mm) is adhered to the internal ceiling and styrol foam boards(20mm) to the walls. The other struction is same as the control room A. Type C is the same as B except wool board(Glass Fiber, 33mm) on the walls. Type D is same as type A except that the thickness of wall is 12mm and wood pyramid type cone$(5\times5\times13cm)$ is adhered to the ceiling ana walls(Fig. 1). When the recorded noise and vibrated noise were controlled in various levels. The noise pressure which passed through the control rooms was measured by sound level meter(Bruel & Kjar 2205, measuring range 37-140dB). In order to calculate the absorption rate in the control rooms the noise pressure was measured at different distances when the recorded noise pressure was radiated. The followings are the results obtained from the experiment. 1. When the noise pressure of the test room was 60dB, transmission rate of type A was $69.7\%$ and increased $3.3\%$ per 10dB. At the same condition, the rate was $53.9\%$ and increased $4.5\%$ per 10dB in type D. Type D was the most effective in noise arresting of the four and the effect was D,C,B and A in order(Fig.2). 2. When the oscillator sound and vessels noise were radiated in 1,000Hz, at one meter distance to the type A and D, the oscillator sound pressure were 77dB and 73dB, while the vessels noise pressure were 73.3dB and 66.2dB respectivley(Fig.3). 3. Refering to the influence of the frequency to the lower oscillator sound(1,000Hz) pressure, both type C and D were almost same at 140cm but type C was 0.3dB lower than type D at 20cm distance(Fig.4).

  • PDF

Formation of GaN microstructures using metal catalysts on the vertex of GaN pyramids (금속촉매를 이용한 GaN 피라미드 꼭지점 위의 마이크로 GaN 구조 형성)

  • Yun, W.I.;Jo, D.W.;Ok, J.E.;Jeon, H.S.;Lee, G.S.;Jung, S.K.;Bae, S.M.;Ahn, H.S.;Yang, M.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.21 no.3
    • /
    • pp.110-113
    • /
    • 2011
  • In this paper, we propose a new method for the fabrication of GaN microstructures formed only on the vertex of GaN pyramid by using of metal catalysts. GaN pyramidal structures were selectively grown on 3 ${\mu}m$ $SiO_2$ dot patterns followed by thin film deposition of Au and Cr only on the vertex area of the GaN pyramids with precisely controlled photolithography. After the metal deposition, the samples were loaded in the MOVPE reactor for the growth of GaN microstructures for 10 minutes. Temperature for the growth of the GaN microstructures was changed from $650^{\circ}C$ to $750^{\circ}C$. Rod type GaN microstructures were grown in the direction of vertical to the six {1-101} facets and the shape of the GaN microstructures was changed depend on the type of metal.

Image Measurement on Influence from Application of Compression Band on Intravenous Urography for Urolithiasis Patient (요로결석 환자의 경정맥 요로조영 검사 시 압박 유무에 따른 영상평가)

  • Kim, Hyeong-Gyun;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.261-266
    • /
    • 2015
  • Intravenous urography (IVU) for urolithiasis is a radiologic examination to diagnosis stone in the ureter path using iodine contrast media, which is radioopacity material. The method includes compression on the upper iliac crest. The compression band prevents outlet of the contrast media through the bladder and enables easier movement to upper urinary tract. This usage depends on the policy of a hospital. Therefore, this study aimed to review and compare the characteristic of progress of contrast media either in compression and non-compression. The retrospective image measurement on 60 cases of intravenous pyelography was conducted at a hospital with the identical type and amount of contrast media as well as criteria for testing. Image measurement was limited to 5 minutes clip, which is optimal for progress of contrast media depending on usage of the compression band. Also, anatomical regions were set as following: "RP" is from renal pyramid to renal pelvis, "PL" is from renal pelvis to lumbar three endplate, and "IU" and "IL" for upper and lower parts from both iliac crests. Analysis has been conducted through the statistical method based on Fisher's Exact Test to find if there are differences of distribution with the anatomical regions with compression or no compression. It has been confirmed that there is no statistical significant difference as the video measurement on 30 cases of compression and non-compression group respectively resulted in P value of 0.580 from left and 0.711 from right (both 0.960). Therefore, it has been concluded that application of a compression band on an intravenous pyelography for urolithiasis patient does not meaningfully affect the progress of contrast media.

Investigation on management conditions for vermicomposting of night soil in Field at N Sewage Water plant (N하수처리장 정화조.분뇨케익의 재활용을 위한 지렁이 사육 조건검토)

  • Kim, K.Y.;Lee, C.B.;Choi, H.G.;Phae, C.G.
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.2
    • /
    • pp.102-113
    • /
    • 2000
  • This study was conducted to investigate the expandibility of sludge treatment by earthworm through real scale experiment and the optimum counter-plan for organic sludge treatment. For the purposes, sludge removal efficienciesof night-soil using earthworm and it's behavior according to the transplanting methods of the earthworm on non-cover worm bed or in the green house worm bed were compared. Sludge uptake rates on non-cover worm bed for 6 months were $0.27{\sim}0.33ton/m^2$ and the excrement of earthworm yields $0.15ton/m^2$(44.1~46.7% of raw night soil sludge dosage). These results were not much different from the worm bed in the green house. The average and maximum earthworm density were about $6.5kg/m^2$ and $7kg/m^2$ respectively on the non-cover worm bed. The density of the worm bed was comparatively higher in spring and fall terms but lower in summer. The amount of old earthworm was much plenty than young earthworm on the non-cover worm bed, resulting in reverse distribution type of pyramid. From the experiments on non-cover worm bed(7,000 pyeong)and in the green house worm bed(1,200 pyeong), it was concluded that landfill and transporting cost could be reduced when the earthworm was applied for the night-soil sludge treatment. Profits from the excrement sale of earthworm was 9,600,000 won. Through this study, it was founded that earthworm treatment method for organic sludge are much more environmentally sound than landfill treatment.

  • PDF

A Study on the Impact Investment for the Revitalization of Financial Institutions of Social Enterprises: in the Case of Britain and U.S.A. (사회적기업의 금융지원 활성화를 위한 임팩트투자 연구 - 영국과 미국 사례를 중심으로 -)

  • Chang, Sug-In;Seong, Yeon-Ok;Lim, Sang-Ho
    • Management & Information Systems Review
    • /
    • v.34 no.2
    • /
    • pp.151-169
    • /
    • 2015
  • Social enterprises that are solving pressing global issues and providing services such as micro-finance, affordable housing, appropriate technology and education for the 'bottom of the pyramid' as well as cultural and community-related businesses that improve the 'quality of life' within a society are the target of impact investments. Among them, a capital financing is one of the most important factor in founding and fostering of social enterprise. However, the capital market for social enterprises in South Korea are not yet sufficiently developed. The Britain and U.S.A. attempted to solve the social problem by the introduction of the social innovation credit model, for example, social impact bonds(SIB), Big Society Capital, DBLIF, and ACCION International, which are considered as an innovative new financing instrument for social program. Instruments are being attempted for the first time in Britain and America. This study have two purposes. The first purpose is abstracting the institutional mechanism for introduction of impact investment such as SIB and DBLIF case in Britain and U.S.A.. Second, analyzing type and mix of policy instrument on impact investment from the perspective of policy instrument.

  • PDF

Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System (자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향)

  • Jeong, Min-Gyu;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.635-642
    • /
    • 2020
  • The purpose of this study was to analysis the effects of shielding area of field configuration with changing of sensitivity and density on tube current (milliampere-seconds, mAs) and image quality in automatic exposure control (AEC) system. The equipment used a digital radiography device (Digital Diagnost, Philips, Netherlands), which has a integral type with an X-ray tube and an indirect digital detector. The AEC system conditions were consisted of 9 setting environments, that mode changing of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). The tube current evaluated automatically exposed mAs under 81 combination conditions crossed by AEC conditions in fixed at 40 kVp. The image quality evaluated the radiographic images that selected valid images by visual assessment the radiographic images of the self-produced conical pyramid phantom and then measured their signal to noise ratio (SNR). As a result, the maximum tube current was 60.0 mAs that automatically exposed conditions were the 100% of shielding area and the sensitivity of S200 and the density of +2.5. The minimum tube current was 0.9 mAs with non-shielding area and the sensitivity of S800 and the density of -2.5. When the shielded area 0% with the sensitivity of S200 and the density of +2.5, the maximum SNR was the highest as 25.2. But when the shielded area 25% with the sensitivity of S800 and the density of -2.5, the minimum SNR was the lowest as 4.7.

The Analysis of Inquiry Scopes in High School General Science Textbook Based on the 6th Curriculum - Emphasizing the Analysis of Inquiry Experiment - (제 6차 교육과정에 따른 고등학교 공통과학 교과서의 탐구영역 분석 - 탐구 실험을 중심으로 -)

  • Park, Won-Hyuck;Kim, Eun-A
    • Journal of The Korean Association For Science Education
    • /
    • v.19 no.4
    • /
    • pp.528-541
    • /
    • 1999
  • In order to obtain data for developing an ideal science curriculum. four kinds of General Science textbooks based on the 6th curriculum were analyzed. Particularly inquiry activities were analyzed by Scientific Inquiry Evaluation Inventory(SIEI). The results are as follows: 1) The average number of inquiry activities in four kinds of textbooks is 115.5. And the number in each textbook is very diverse: textbook A contains 94 inquiry activities, textbook B 147. textbook C 100 and textbook D 121. 2) As for the number of inquiry activity scopes in four kinds of textbook. observation comes to 22, experiment 117, interpreting data 196, investigation 64, discussion 51, classification 4 and prediction 8. And then the conceptional inquiry activity is about 2.3 times as many as the inquiry experiment. 3) According to the analysis of each inquiry task by SIEI. textbook A has 268, textbook B 328, textbook C 207 and textbook D 304. 4) In the analysis of the structure of inquiry activity, the evaluation of the competition and cooperation scale shows more emphasis on common tasks. no pooled results(87.1 %). The discussion scale mostly consists of activities without discussion required among students(83.5%). The evaluation of openness scale shows more emphasis on activities with problems, procedures and answers presented(58.3%). In the evaluation of inquiry scope scale, the inquiry scope scale mostly has the activities to demonstrate or verify the contents of the text(66.9%). 5) As for the analysis of inquiry activities as a whole. The inquiry pyramid in four kinds of General Science textbooks shows the type I that emphasizes the inquiry activities in low level such as gathering and organizing data. The inquiry index in four kinds of textbooks is average 47.8, shows very high level (above 35).

  • PDF