• 제목/요약/키워드: push-off

검색결과 90건 처리시간 0.023초

유도가열용 ZCS PWM SEPP 고주파 인버터의 특성 (Character of Induction Heating ZCS PWM SEPP High Frequency Inverter)

  • 문상필;김칠용;곽동걸;김춘삼
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.133-135
    • /
    • 2007
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Pull)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

Comparison of Plantar Pressure and Contact Time on Gait between the Korean Young and the Elderly Women

  • Kim, Hee-Eun
    • 한국의류산업학회지
    • /
    • 제19권5호
    • /
    • pp.602-607
    • /
    • 2017
  • This study was undertaken to compare the gait characteristics between the Korean elderly and young adults, we measured the plantar pressure and contact time of gait with barefoot along a walkway at their preferred walking speed. The results indicate that older people exhibited significantly less plantar pressure than young adult in all 3 regions (FF, MF and RF) and significantly less time % on the initial contact phase (ICP), forefoot push-off phase (FFPOP) and significantly more % forefoot contact phase (FFCP) and foot flat phase (FFP). The converted plantar pressure value to percentage, it showed more pressure in forefoot (FF) in the elderly person than the young adults. It could be explained that the forward shifting in plantar pressure are associated with a more flexed posture of elderly such as actual stabilizing fearrelated adaptations. Longer total foot contact time in the elderly means that the old people show the decreased gait velocity. In other words, lower velocity was found to be associated with pre-existing fear of falling. With longer contact time and slower stepping movement, the elderly become more unstable. With these findings, it could be confirmed that there were significant changes in foot characteristics which contribute to alter the plantar pressure and contact time during gait with advancing age. Further research is required to establish possible links to risk of falling and development of footwear in the elderly adults.

New Fluid Flow System for Simulation of Mechanical Loading to Bone Cells During Human Gait Cycle

  • Ahn, Jae-Mok
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권3호
    • /
    • pp.377-386
    • /
    • 2007
  • Mechanical loading to bone cells using simple sine wave or constant wave fluid flow has been widely used for in vitro experiments. Human gait is characterized by a complex loading to bones of lower extremities which results from a series of events consisting of heel strike, foot flat and push-off during the stance phase of the gait cycle. Telemetric force analyses have shown that human femora are subject to multiphasic loading. Therefore, it would be ideal if the physiologic loading conditions during human walking can be used for in vitro mechanotransduction studies. Here, for a mechanotransduction study, we develop it fluid flow system (FFS) in order to simulate human physiologic mechanicalloading on bone cells. The development methods of the FFS including the COR (Center for Orthopedic Research), monitor program are presented. The FFS could generate various multiphasic loading conditions of human gaits with output flow. Wall shear distribution was very uniform, with 81 % of the effective loading area of the culture on a glass slide. Our results demonstrated that the FFS, provide a new translational approach for unveiling molecular mechanotransduction pathways in bone cells.

새로운 유도가열용 소프트 스위칭 고주파 인버터 (Soft Switching High Frequency Inverter for New Induction Heating)

  • 김칠용;문상필;김영문;김해재;류재엽;김수욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.119-124
    • /
    • 2007
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Pull)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

Stainless 생산을 위한 냉연 합리화 (A Revamping of Pickling and Tandem Cold Rolling Mill for Producing Stainless Steel)

  • 이동호;기을도;조성봉;이균백;김동호
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 제5회 압연심포지엄 신 시장 개척을 위한 압연기술
    • /
    • pp.109-118
    • /
    • 2004
  • No.2 PCM (Pickling and tandem cold rolling mill) at Pohang works was revamped in 2003. The purpose of this project is to produce carbon and stainless steel using conventional carbon production process, rolling and annealing. This paper introduces the applied facilities and technologies of PCM which are used in production of carbon and stainless steel. To realize the main purpose of this project, POSCO have developed laser weld technology in normal carbon and special steel (stainless, high carbon and high silicon). And this report describes the method which is developed to get down the surface defect of stainless 400 series. After revamping, No.2 PCM can have competitive power in this field and can supply the special steel using carbon rolling process.

  • PDF

태안 마도 출토 도자기의 염에 의한 손상상태 연구 (A Study on the Soluble Salt and Deterioration of Ceramics from Taean Shipwreck)

  • 장성윤;남병직;박대우;강현미;정용화
    • 보존과학연구
    • /
    • 통권30호
    • /
    • pp.189-202
    • /
    • 2009
  • Ceramics from Taean shipwreck were studied to investigate the deterioration by soluble salts and desalination pattern according to each ceramic characterization. NaCl crystals were found as a crystal growth on the ceramic microstructure and deteriorated to push off the glaze layer of some Puncheong ware sample. As a result of monitoring the desalination pattern of ceramics for 74days, the earthenware sample with big pores and no glaze removed soluble salts so fast, but Puncheong ware and Whiteware samples removed lots of soluble salts slowly and continuously. Generally, it takes long time to remove soluble salts from porcelains, due to small pores and glaze, but the long-term desalination probably can cause the damage on the surface layer such like glaze. As some soluble salts still remains in the ceramic microstructures after desalination, it is very important to control and keep the relative humidity stable through the proper storage. There are various ceramic deterioration patterns by soluble salts. Therefore, it needs to select the desalination method of ceramics from shipwreck, considering the material characteristics and the production techniques.

  • PDF

유아와 성인의 보행 특성 비교 (Comparative gait characteristics of infant and adults)

  • 장윤희;양길태;임송학;문무성;이경옥;김미예
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.86-87
    • /
    • 1998
  • To understand the developmental process of the gait pattern from infancy to the adult, a gait analysis for a 14 months female infant has been performed for ten weeks. The gait parameters has been measured every other week since the week when she was able to walk without aid. The infant gait data at the tenth week of the test shows a similar pattern to the adult gait in many aspects including initial knee flexion, initial ankle dorsiflexion, the push-off pattern, etc. There is not a significant change in the hip flexion angle from week to week from the two weeks after the test started. To check the individuality in the collected data, more infant subjects are being tested presently.

  • PDF

지하철 승강장 급배기 조건에 따른 화재 위험성 평가 (Fire Risk Assessment for Subway Station According to Supply and Exhaust Conditions)

  • 김하영;이동호;김정엽
    • 한국화재소방학회논문지
    • /
    • 제22권5호
    • /
    • pp.29-34
    • /
    • 2008
  • 본 연구에서는 대피자의 최적 배연조건 확립을 위하여 CFD모델을 이용한 수치해석을 통해 지하철 승강장 내에서의 화재 시 다양한 배연조건에서의 화재 위험성을 검토하였다. 결과로 스크린도어를 설치한 경우가 설치하지 않은 경우보다 온도의 상승폭이 최대 $65.37%{\sim}74.97%$ 낮게 나타났다. 또한 급기나 압인배기시 승강장에 난류가 발생함에 따라 온도 및 연기층이 교란되어 하락됨에 따라 탈출시 위험을 유발할 수 있는 것으로 판단되었다. 따라서 배연용량 및 승강장 공간 설정시 배연조건에 따른 화재 특성을 고려한 설계가 필요하다.

유도가열용 ZCS PWM SEPP 고주파 인버터 (Induction Heating ZCS PWM SEPP High Frequency Inverter)

  • 문상필;권순걸;이종걸;주석민;강신출
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.241-243
    • /
    • 2008
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Full)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

흡착식 소켓을 착용한 일측 대퇴절단환자의 소켓내부압력분포 (Socket Pressure Distribution of the Uni-Lateral Trans-Femoral Amputee with a Suction Socket)

  • 장윤희;양길태;임송학;문무성;김영호
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권4호
    • /
    • pp.417-422
    • /
    • 1998
  • 본 연구는 대퇴의족착용자의 정적중립상태 및 자유보행시에 단단부와 소케의 경계에 작용하는 압력 분포를 측정하였다. 정적중립상태에서는 단단부의 외측과 내측면과 후면에서 압력집중현상이 나타나고, 자유보행시는 이러한 압력집중이 보행중에 일정한 형태로 이동함을 알 수 있었다. 최대 소켓압력은 중간입각기나 발뒤축들림기에 외측, 내측 앞쪽, 후면에서 나타나고 있고, 소켓과 단단부 사이의 상태를 확인하는 방법중 하나로 소켓 압력 측정을 사용할 수가 있다.

  • PDF