• 제목/요약/키워드: push test

검색결과 392건 처리시간 0.021초

Interfacial shear resistance of angle shear connectors welded to concrete filled U-shaped CFS beam

  • Oh, Hyoung Seok;Shin, Hyeongyeop;Ju, Youngkyu;Kang, Thomas H.K.
    • Steel and Composite Structures
    • /
    • 제43권3호
    • /
    • pp.311-325
    • /
    • 2022
  • For multi-story structural systems, Korean steel industry has fostered development of a steel-concrete composite beam. Configuration of the composite beam is characterized by steel angle shear connectors welded to a U-shaped cold formed-steel beam. Effects of shear connector orientation and spacing were studied to evaluate current application of the angle shear connector design equation in AC495. For the study, interfacial shear resistance behavior was investigated by conducting 24 push-out tests and attuned using unreinforced push-out specimens. Interfacial shear to horizontal slip response was reported along with corresponding failure patterns. Pure shear connector strength was also evaluated by excluding concrete shear contribution, which was estimated in relation to steel beam-slab interface separation or interfacial crack width.

수분의 흡수에 따른 구조용 목질판넬의 인발 및 함입성능 (Nail Withdrawal Resistance and Embedding Strength of Structural Wood Panels with Water Absorption)

  • 오세창
    • 한국가구학회지
    • /
    • 제10권2호
    • /
    • pp.1-8
    • /
    • 1999
  • The use of structural wood based panels like plywood, OSB in many applications involves the use of nails, and data on the performance of panel-nail connection are needed for design and comparative purpose. This study was carried out to develop basic information on nail performance(withdrawal, embedding, nailhead push through) with water absorption in plywood and OSB. In withdrawal resistance test, initial stiffness of plywood performed better than OSB in 24hr soaked condition. The soaked condition reduced average nail withdrawal resistance value about 46% (12d mail), 53%(8d nail) in OSB, 17%(12d mail), 24%(8d mail) in plywood. The nail embedding strength of plywood also performed better than that of OSB and retention value(wet strength/dry strength) yielded similar in each nail types. The nail head push through capacity of OSB was higher than that of plywood in dry condition, but equal or lower in soaked condition. Therefore, critical consideration about structural panels is required in moist applications. The average values of nail withdrawal, nail embedding strength and nail head push through resistance of tested materials meet the minimum requirement of various specification and standards.

  • PDF

스마트 가전의 전환의도에 관한 연구 : 이주이론과 현상유지편향 관점 (Understanding Individual's Switching Intentions to Smart Appliances : A Perspective of the Push-Pull-Mooring Framework and Status Quo Bias)

  • 김상현;박현선
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제27권2호
    • /
    • pp.221-245
    • /
    • 2018
  • Purpose This study aims to investigate the factors that influence switching intention of Smart Appliances. We focuses on Push-Pull-Mooring theory and status quo bias as factors related to switching behavior. Design/methodology/approach This study developed an model to explain the switching intention of Smart Appliances and conducted structural equation modeling with AMOS22.0. To test the proposed hypotheses, we collected 319 survey responses from smart appliances's users. Findings The results indicated that low usefulness and low ease of use had an effect on the switching intention of smart appliances. The results also indicated that attractiveness of the alternative and social norms had an effect on the switching intention of smart appliances. Lastly, The difference between the relation of push effect and switching intention and the relation of pull effect and switching intention was found to be due to the level of status quo bias. The academic and managerial implications were discussed based on the results of empirical analysis.

컨택센터 중심에서 인공지능 챗봇 중심 고객 서비스로의 사용자 전환의도에 관한 연구 (A Study on User Switching Intention from Contact Center-oriented to AI Chatbot-Oriented Customer Services)

  • 안승규;안현철
    • 디지털산업정보학회논문지
    • /
    • 제19권1호
    • /
    • pp.57-76
    • /
    • 2023
  • This study analyzes the factors and effects on the users' intention to switch from contact center-oriented to AI chatbot-oriented customer services by combining Push-Pull-Mooring Model and provides insights for companies considering the adoption of AI chatbots. To test the model, we surveyed users with experience using chatbots at least once across different age groups. Finally, we analyzed 176 cases for the analysis using IBM SPSS Statistics and SmartPLS 4.0. The results of hypotheses testing rejected the hypotheses for variables of inconsistent quality and low availability of push factors and low switching cost of mooring factor while accepting the hypotheses for the tardy response of push factors and all pull factors. Therefore, these findings provide important implications for researchers and practitioners who wish to conduct research or adopt AI chatbots. In conclusion, users do not feel inconvenienced by the contact center-oriented service but also perceive high trust and convenience with AI chatbot-oriented service. However, despite low switching costs, users consider chatbots a complementary tool rather than an alternative. So, companies adopting AI chatbots should consider what features the users expect from AI chatbots and facilitate these features when implementing AI chatbots.

농어촌 체험 고객 만족에 영향을 미치는 요인 (Factors Affecting the Customer Satisfaction of Rural Experience -Applying Unified PPM Model -)

  • 최양애;정병규
    • 벤처혁신연구
    • /
    • 제2권2호
    • /
    • pp.79-94
    • /
    • 2019
  • 본 연구의 목적은 농어촌 체험에 영향을 미치는 요인을 통합된 PPM모델(unified push-pull-mooring model)을 적용하여 탐색하는 것이다. 이론적인 모델은 PPM을 근간으로 하여 새로운 변수들을 도입한 통합된 PPM모델이다. 새롭게 도입된 변수 중 pull 요인은 체험이론과 ServQual 모형을 바탕으로 재구성하였다. 종속변수는 고객 만족을 설정하였다. 가설은 다음과 같이 설정하였다. Push 요인은 체험 만족에 부(-)의 영향을 미치고, Pull 요인인 체험요소와 체험품질은 체험 만족에 정(+)의 영향을 미칠 것이다. 또한, mooring 요인은 체험 만족에 부(-)의 영향을 미칠 것이다. 본 연구의 연구 모형을 314개 설문데이터를 기반으로 하여 구조방정식으로 검정하였다. 연구 결과 Pull 요인인 체험품질은 체험 만족에 정(+)의 영향을 미쳤다. Mooring 요인은 체험의도에 부(-)의 영향을 미치는 것으로 나타났다. 하지만, push 요인과 체험 만족 간, 체험요소와 체험 만족 간에는 유의한 영향 관계가 검정되지 않았다. 이러한 연구 결과는 이론적으로는 농어촌 체험에 있어서 기존의 pull, push 요인 위주의 분석에서 나아가 심리적인 mooring 요인도 체험에 중요한 영향을 미친다는 것을 검정하였다. Pull 요인으로 도입된 체험요소와 체험품질을 바탕으로 제안된 통합된 PPM모델이 유용한 분석의 틀이 될 수 있음을 검정하였다. 실무적으로는 농어촌 체험을 활성화시키기 위해 어떠한 요소에 전략적으로나 마케팅적으로 집중해야 하는지에 대한 시사점을 제공할 수 있었다.

프리캐스트 바닥판 교량 전단연결부의 전단강성 (Shear Stiffness of Shear connections in Full-Depth Precast Concrete Deck Bridge)

  • 심창수;정철헌;김철영;장승필
    • 한국강구조학회 논문집
    • /
    • 제10권4호통권37호
    • /
    • pp.749-758
    • /
    • 1998
  • 현장타설 콘크리트 바닥판 교량의 전단연결부의 강성 평가를 분석하고 프리캐스트 콘크리트 바닥판 교량의 전단연결부의 강성을 평가하기 위한 실험을 통해 전단강성을 구하였다. 전단연결부 채움재료의 강도특성에 대한 변수연구와 국부적인 응력분포를 파악하기 위하여 push-out 실험부재에 대한 3차원 유한요소해석을 수행하였다. 해석을 통해 구한 하중-슬립관계를 실험에서 구한 것과 비교하여 타당성을 검증하고 프리캐스트 바닥판 교량 전단연결부의 초기 강성에 대한 평가식을 제안하였다. 선형해석을 수행하여 전단연결재 지름과 모르터의 강도에 따른 손상의 양상과 전단연결재와 무수축모르터에 각각 파괴기준을 적용하여 파괴하중을 예측하고 실험값과 비교하였다.

  • PDF

Single Well Push-Pull Test를 이용한 TCE 오염 지하수의 In-Situ Bioremediation 타당성조사

  • 김영
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.188-191
    • /
    • 2003
  • Sing]e-well-push-pull tests were developed for use in assessing the feasibility of in-situ aerobic cometabolism of chlorinated aliphatic hydrocarbons (CAHs). The series includes Transport tests, Biostimulation tests, and Activity tests. Transport tests are conducted to evaluate the mobility of solutes used in subsequent tests. These included bromide or chloride (conservative tracers), propane (growth substrate), ethylene, propylene (CAH surrogates), dissolved oxygen (electron acceptor) and nitrate (a minor nutrient). Tests were conducted at an experimental well field of Oregon State University. At this site, extraction phase breakthrough curves for all solutes were similar, indicating apparent conservative transport of the dissolved gases and nitrate prior to biostimulation. Biostimulation tests were conducted to stimulate propane-utilizing activity of indigenous microorganisms and consisted of sequential injections of site groundwater containing dissolved propane and oxygen. Biostimulation was detected by the increase in rates of propane and oxygen utilization after each injection. Activity tests were conducted to quantify rates of substrate utilization and to confirm that CAH-transforming activity had been stimulated. In particular, the transformation of injected CAH surrogates ethylene and propylene to the cometabolic byproducts ethylene oxide and propylene oxide provided evidence that activity of the monooxygenase enzyme system, responsible for aerobic cometabolic transformations of CAHs had been stimulated. Estimated zero-order transformation rates decreased in the order propane > ethylene > propylene. The series of push-pu3l tests developed and field tested in this study should prove useful for conducting rapid, low-cost feasibility assessments for in situ aerobic cometabolism of CAHs.

  • PDF

Effect of antioxidants on push-out bond strength of hydrogen peroxide treated glass fiber posts bonded with two types of resin cement

  • Khoroushi, Maryam;Mazaheri, Hamid;Tarighi, Pardis;Samimi, Pouran;Khalighinejad, Navid
    • Restorative Dentistry and Endodontics
    • /
    • 제39권4호
    • /
    • pp.303-309
    • /
    • 2014
  • Objectives: Hydrogen peroxide ($H_2O_2$) surface treatment of fiber posts has been reported to increase bond strength of fiber posts to resin cements. However, residual oxygen radicals might jeopardize the bonding procedure. This study examined the effect of three antioxidant agents on the bond strength of fiber posts to conventional and self-adhesive resin cements. Materials and Methods: Post spaces were prepared in forty human maxillary second premolars. Posts were divided into five groups of 8 each: G1 (control), no pre-treatment; G2, 10% $H_2O_2$ pre-treatment; G3, G4 and G5. After $H_2O_2$ application, Hesperidin (HES), Sodium Ascorbate (SA) or Rosmarinic acid (RA) was applied on each group respectively. In each group four posts were cemented with Duo-Link conventional resin cement and the others with self-adhesive BisCem cement. Push-out test was performed and data were analyzed using 2-way ANOVA and tukey's post-hoc test (${\alpha}=0.05$). Results: There was a statistically significant interaction between the cement type and post surface treatment on push-out bond strength of fiber posts (p < 0.001, F = 16). Also it was shown that different posts' surface treatments significantly affect the push-out bond strength of fiber posts (p = 0.001). $H_2O_2$ treated posts (G2) and control posts (G1) cemented with Duo-link showed the highest ($15.96{\pm}5.07MPa$) and lowest bond strengths ($6.79{\pm}3.94$) respectively. Conclusions: It was concluded that $H_2O_2$ surface treatment might enhance the bond strength of fiber posts cemented with conventional resin cements. The effect of antioxidants as post's surface treatment agents depends on the characteristics of resin cements used for bonding procedure.

Experimental and numerical studies on the shear connectors in steel-concrete composite beams at fire and post fire exposures

  • Mirza, Olivia;Shil, Sukanta Kumer;Rashed, M.G.;Wilkins, Kathryn
    • Steel and Composite Structures
    • /
    • 제39권5호
    • /
    • pp.529-542
    • /
    • 2021
  • Shear connectors are required to build composite (concrete and steel) beams. They are placed at the interface of concrete and steel to transfer shear and normal forces between two structural components. Such composite beams are sensitive to provide structural integrity when exposed to fire as they loss strength, stiffness, and ductility at elevated temperature. The present study is designed to investigate the shear resistance and the failure modes of the headed stud shear connectors at fire exposure and post-fire exposure. The study includes ordinary concrete and concrete with carbon nanotubes (CNTs) to build composite (concrete-steel) beams with structural steel. Experimental push tests were conducted on composite beams at ambient and elevated temperatures, such as 200, 400 & 600℃. Moreover, push tests were performed on the composite beams after being exposed to 200, 400 & 600℃. Push test results illustrated the reduction of ultimate shear capacity and stiffness of headed stud shear connectors as the temperature increased. Although similar values of ultimate shear were obtained for the headed stud connectors in both ordinary and CNT concrete, the CNT modified concrete reduced the concrete spalling and cracking compared to ordinary concrete and was observed to be effective at temperatures greater than 400℃. All specimens showed a lower shear resistance at fire exposures compared to the corresponding post-fire exposures. Moreover, numerical simulation by Finite Element (FE) analyses were carried out at ambient temperature and at fire conditions. The FE analysis results show a good agreement with the experimental results. In the experimental studies, failure of all specimens occurred due to shear failure of headed stud, which was later validated by FE analyses using ABAQUS.

강합성 거더용 철근콘크리트 전단연결체의 전단강도 평가 (Estimation of Shear Strength of RC Shear Connection for the Steel-Concrete Composite Girder)

  • 신현섭;유영준;정연주;엄인수
    • 대한토목학회논문집
    • /
    • 제30권3A호
    • /
    • pp.229-239
    • /
    • 2010
  • 최근 건설재료의 효율적 활용과 단면구조의 최적화로써 기존 강합성 거더의 구조성능과 시공성을 향상시키고자 새로운 형상의 강합성 거더 및 거더와 바닥판의 전단합성을 위한 RC 전단연결체가 고안된 바 있다. 본 연구에서는 RC 전단연결체의 구조거동 및 전단강도를 평가하였다. 이를 위해 전단철근비를 변수로 하여 Push-out 실험을 실시하였고, 다양한 설계변수에 대한 유한요소해석을 수행하여 그 결과를 분석하였다. 실험 및 유한요소해석 결과에 의하면 RC 전단연결체의 전단강도를 기존 규준식으로 산정할 경우 매우 안전측으로 평가된다. 본 연구에서는 RC 전단연결체의 전단강도를 적절히 산정하기 위해 회귀분석적 방법으로 전단강도 평가식을 제안하였다.