• Title/Summary/Keyword: puncture test

Search Result 86, Processing Time 0.023 seconds

Effects of Cooking Conditions on the Texture of Cooked Soybeans (조리된 콩의 텍스쳐에 미치는 가열 조건의 영향)

  • Rhee, Chong-Ouk;Kim, Dong-Youn;Jung, Ji-Heun;Kim, Kwan;Park, Keun-Hyung;Chung, Hee-Jong
    • Applied Biological Chemistry
    • /
    • v.32 no.3
    • /
    • pp.216-221
    • /
    • 1989
  • Soaking of soybeans and the subsequent effect on cooking kinetics were investigated by the means of puncture test and shear press with Instron universal testing machine. Soaked soybeans were water cooked at temperatures of $90{\sim}135^{\circ}C$ adjusted with oil bath. Instron puncture force of 0.15kg and shear force of 1.2kg/g-soybean were appeared as the eating soft texture by sensory evaluation. Softening activation energies of yellow soybeans for puncture and shear force were 14,540cal/g-mole and 21,374cal/g-mole. z-values were calculated as $42.1^{\circ}C$ and $37.4^{\circ}C$, respectively.

  • PDF

Effect of Preeducation and Health Contract on Adaptability and Anxiety during Spinal Puncture in Children with Leukemia (검사 전 교육과 건강 계약이 백혈병 아동의 척수 검사 순응 정도와 불안에 미치는 효과)

  • Park, Ho-Ran;Koo, Hyun-Young;Cho, Mi-Na
    • Child Health Nursing Research
    • /
    • v.12 no.4
    • /
    • pp.462-469
    • /
    • 2006
  • Purpose: This study was done to verify the effects of preeducation and health contract on anxiety and adaptability of children with leukemia when undergoing a spinal puncture. Methods: Children in experimental group 1 (10) were given preeducation prior to the procedure and children in experimental group 2 (13), a health contract. Children in the control group (16) received the regular hospital preparation. Observation tools were used to evaluate adaptability and anxiety. Heart rate and oxygen saturation was also used as a measure of anxiety. The data were analyzed using the SPSS program. Results: Compared with the control group, experiment groups 1 and 2 showed significant difference in adaptability regarding the number of assistants and test posture. Experiment groups 1 and 2 showed significant difference in voice tone and movement level when compared with the control group. Elevation level in heart rate showed significant differences between the three groups. Conclusions: Preeducation and nursing mediation through health contracts were shown to be effective methods to reduce anxiety and increase adaptability in children with leukemia who were undergoing a spinal tap.

  • PDF

A Comparative Study of Two Different Heel Lancet Devices for Blood Collection in Preterm Infants (미숙아에서 채혈을 위한 발뒤꿈치 천자시 두 종류 천자 기구의 비교)

  • Lim, Hyo-Bin;Rhu, Mi-Joo;Jung, Ji-Mi;Jeon, Ga-Won;Sin, Jong-Beom
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.239-244
    • /
    • 2010
  • Purpose: To evaluate two different heel lancet device in terms of pain response and success of the procedure in the preterm infants undergoing heel puncture. Methods: 100 preterm infants undergoing capillary blood gas analysis or capillary bilirubin monitoring underwent heel puncture, were randomly allocated to blood sampling from the heel with either a conventional manual lancet or an automatic incision device. Primary outcome measures included the Premature Infants Pain Profile (PIPP) score, total duration of procedure, number of heel puncture and number of bruise. The pain response was evaluated using PIPP score and the effectiveness was evaluated using three criteria: total duration of blood sampling, number of puncture, bruising of the heel or ankle. Statistical analysis was performed using the SPSS ver. 13.0 program. Difference between the groups were analysed with t test (continuous variables) and the Chi square test or Fisher test (categorical variables). Results: The mean PIPP score was 4.91 for the automatic lancet group compared with 5.84 for the conventional manual lancet group (P=0.0255).The number of pain scores above 7 during blood collection did not differ between two groups (P=0.2167). The procedure took less time to perform in the automatic lancet group (mean, 30.69 seconds) than in the conventional lancet group (mean, 48.92 seconds) (P<0.0001). Conclusion: This study demonstrated that the automatic lancet device causes less pain and a shorter procedure time than the conventional manual lancet in preterm infants undergoing heel puncture. On the basis of these results the automatic lancet device is very useful method for blood collection in preterm infants by heel puncture.

Development and Application of Test Apparatus for Classification of Sealed Source (밀봉선원의 성능시험을 위한 장치 개발 및 적용)

  • Kim, Dong-Hak;Seo, Ki-Seog;Bang, Kyoung-Sik;Lee, Ju-Chan;Son, Kwang-Je
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.35-44
    • /
    • 2007
  • Sealed sources have to conducted the tests be done according to the classification requirements for their typical usages in accordance with the relevant domestic notice standard and ISO 2919. After each test, the source shall be examined visually for loss of integrity and pass an appropriate leakage test. Tests to class a sealed source are temperature, external pressure, impact, vibration and puncture test. The environmental test conditions for tests with class numbers are arranged in increasing order of severity. In this study, the apparatus of tests, except the vibration test, were developed and applied to three kinds of sealed source. The conditions of the tests to class a sealed source were stated and the difference between the domestic notice standard and ISO 2919 were considered. And apparatus of the tests were made. Using developed apparatus we conducted the tests for $^{192}Ir$ brachytherapy sealed source and two kinds of sealed source for industrial radiography. $^{192}Ir$ brachytherapy sealed source is classified by temperature class 5, external pressure class 3, impact class 2 and vibration and puncture class 1. Two kinds of sealed source for industrial radiography are classified by temperature class 4, external pressure class 2, impact and puncture class 5 and vibration class 1. After the tests, Liquid nitrogen bubble test and vacuum bubble test were done to evaluate the safety of the sealed sources.

An Experimental Study on the Performance of Liquid Spill Stopper to Prevent Flood through the Hull Punctures (선박파공으로 인한 선박침수 방지를 위한 파공봉쇄장치 성능의 실험적 연구)

  • Moon, Jung-Hwan;Kim, Jin-Kyeong;Kwon, Ki-Seng;Jung, Kyung-Tae;Yun, Jong-Huwi
    • Journal of Navigation and Port Research
    • /
    • v.37 no.2
    • /
    • pp.149-154
    • /
    • 2013
  • This paper considers the issue of LSS(Liquid Spill Stopper)'s performance verification testing against external resisting force. The importance of the test is to ascertain the possibility of liquid spill stop quickly and efficiently by LSS. The method adopted in this research is the experimental device for puncture's inflow pressure and test the adhesive (magnetic) force on shell plates during the sailing. The major results of the paper are the followings : (a) The performance of LSS against 40 and 100mm diameter puncture was confirmed under 1.0bar. (b) LSS near bow detached first at 20.2 knots. This indicates that LSS can recover the damaged movability needed to naval warships' operation as well as merchant ships.

A Study on the microstructure and Surge Characteristics of ZnO varistors for distribution Arrester (배전급 피뢰기용 ZnO 바리스터 소자의 미세구조 및 서지 특성에 관한 연구)

  • 김석수;조한구;박태곤;박춘현;정세영;김병규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.2
    • /
    • pp.190-197
    • /
    • 2002
  • In this thesis, ZnO varistors with various formulation, such as A∼E, were fabricated according to ceramic fabrication method. The microstructure, electrical properties, and surge characteristics of ZnO varistors were investigated according to ZnO varistors with various formulation. In the microstructure, A∼E\`s ZnO varistor ceramics sintered at 1130$\^{C}$ was consisted of ZnO grain(ZnO), spinel phase (Zn$\_$2.33/Sb$\_$0.67/O$\_$4/), Bi-rich phase(Bi$_2$O$_3$) and intergranuler phase, wholly. Lightning impulse residual voltage of A, B, C and E\`s ZnO varistors suited standard characteristics, below 12kV at current of 5kA. On the contrary, D\`s ZnO varistor exhibited high residual voltage as high reference voltage. In the accelerated aging test, leakage current and watt loss of B, C and D\`s ZnO varistors increases abruptly with stress time under the first a.c. stress(115$\^{C}$/3.213kV/300h). Consequently, C varistor exhibited a thermal run away. On the contrary, leakage current and watt loss of A and C\`s ZnO varistors which show low initial leakage current exhibited constant characteristics. After high current impulse test, A\`s ZnO varistor has broken the side of varistor but impulse current flowed. On the contrary, E\`s ZnO Varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After long duration impulse current test, E\`s ZnO varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After high current impulse test and long duration impulse current test, E\`s ZnO varistor exhibited very good characteristics which variation rate of residual voltage is 1.4% before and after test.

Clinical Application of Ultrasound-Guided Thyroid Fine Needle Aspiration Biopsy and Thinprep Cytology Test in Diagnosis of Thyroid Disease

  • Wei, Ying;Lu, Yao;Li, Chenxi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.10
    • /
    • pp.4689-4692
    • /
    • 2016
  • Purpose: To study the clinical application value of ultrasound guided thyroid fine needle aspiration biopsy and thinprep cytology testing in diagnosis of thyroid disease. Methods: A total of 78 patients with thyroid nodules were enrolled, 34 males and 44 females, aged 33-64 years old with mean age of 47.6 years. All underwent thyroid module fine needle puncture after surgery to assess cell pathology and histopathological features. Results: Sufficient specimens were obtained from all of 78 patients, the cytological results of 73 cases (93.6 %) being consistent with pathological results. While 20 cases (25.6 %) were malignant tumors, 44 (56.4 %) were benign and 9 (11.5 %) were non-tumor lesions. The sensitivity of benign and malignant thyroid nodule by thyroid fine needle puncture was 90.9 %, specificity was 98.1 % and the positive predictive value was 96.3 %. Conclusions: It is demonstrated that ultrasound-guided thyroid fine needle aspiration biopsy and thinprep cytology testing have diagnostic value in clinical application for thyroid disease,showing good diagnostic coincidence rates with histopathological examination. They can thus be regarded as safe and effective for preoperative diagnosis and providing an appropriate basis for selection of surgery.

The Effect of Roller Acupuncture Stimulation on Baesu Spots of Joktaeyang Bangkwang Kyeong in the Reaction to Physiologic Pain in Neonates (足太陽膀胱經(족태양방광경)의 背?穴(배수혈) 車鍼刺戟(차침자극)이 신생아의 생리적 통증반응에 미치는 효과)

  • Lee, Ji-Won;Kim, Yang-Hee
    • Child Health Nursing Research
    • /
    • v.12 no.1
    • /
    • pp.75-83
    • /
    • 2006
  • Purpose: This study was done to verify the effect of roller acupuncture stimulation on baesu spots of joktaeyang bangkwang kyeong in the reaction to physiologic pain(heart rate, percutaneous oxygen saturation, respiration rate) in neonates. Method: This study was a nonequivalent control group non-synchronized design. The participants were 40 normal neonates who were born at a hospital in Busan. These neonates were undergoing heel puncture for blood type tests. The neonates were divided into 2 groups: 20 in the experimental group who were stimulated with roller acupuncture before the heel puncture and 20 neonates in the control group who were not stimulated. The heart rate and percutaneous oxygen saturation were measured using a cardiopulmonary monitor and the respiration rate was measured directly. The data were analyzed with SPSS 10.0 program using χ²-test, t-test and Repeated Measure ANOVA. Results: There was a significant difference (F=3.287, p=.043) for heart rate on the interaction between time and group. There was a significant difference (F=5.122, p=.008) for percutaneous oxygen saturation on the interaction between time and group. Conclusion: On the basis of results, it was verified that the roller acupuncture stimulation on baesu spots of joktaeyang bangkwang kyeong had effect of relieving pain in the neonates.

  • PDF

A Study on the aging characteristics of Suspension insulators (현수애자의 경년변화 특성에 관한 연구)

  • 송일근;김상준;김주용;곽희로
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.4
    • /
    • pp.85-92
    • /
    • 1996
  • This paper describes thermal-mechanical performance and ultimate mechanical-strength test for the purpose of aging analysis of suspension insulator. The temperature of insulator surface according to the aging of suspension insulator was rised about 2[$^{\circ}C$] to 7~8[$^{\circ}C$] difference comparing with the atmospheric temperature. The autoclave expansion of portland cement at the specimen that had much puncture insulator(autoclave measuring value : 0.37[%]) was higher than those of a little puncture insulator (autoclave measuring value : 0.1[ %] ). Quality standard and mechanical-strength of used suspension insulator deteriorate more remarkably than those of new suspension insulator. It is required that thermal-mechanical performance test standard be revised in the future.

  • PDF

Effect of Sodium Acetate and Calcium Chloride on Characteristics of Kakdugj (Sodium Acetate와 Calcium Chloride를 첨가한 깍두기의 특성)

  • Um, Jin-Young;Kim, Kwang-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.140-144
    • /
    • 1990
  • This study was undertaken to examine if sodium acetate and/or calcium chloride would increase the firmness and/or retard rancidity of Kakdugj (Korean seasoned pickles of cubed radish roots) during short $(at\;20^{\circ}C)$ or long $(at\;4^{\circ}C)$ period of fermentation During the fermentation periods, pH and acidity were higher in Kakdugis containing 0.3 or 0.6% Na-acetate than in the other samples at both storage temperatures. Firmness was increased with addition of 0.05% Calcium chloride and synergistic effect on firmness was observed when Calcium chloride and Na-acetate were added together. Sourness did not decreased in samples containing 0.3% Na-acetate at either fermentation periods but decreased in those containing 0.6% Na-acetate and stored for long. Saltiness was increased slightly with the addition of Calcium chloride. Compression test gave closer result to sensory evaluation than puncture test In the measurement of firmness with Instron.

  • PDF