• Title/Summary/Keyword: punching shear strength

Search Result 131, Processing Time 0.03 seconds

Punching Shear Strength of Reinforced Concrete Bridge Decks with LB-DECK (LB-DECK를 이용한 철근콘크리트바닥판의 펀칭전단강도)

  • Youn, Seok-Goo;Lee, Jae-Hong;Cho, Sun-Kyu;Jeong, Jae-Dong;Won, Yong-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.390-393
    • /
    • 2006
  • LB-DECK is used for both of permanent formwork and structural component with cast-in place concrete of concrete bridge decks. Current Korean design code recommends that concrete bridge deck with precast concrete panels have to be designed only using conventional flexural design method and does not allow the empirical design method which is based on punching shear strength of bridge deck. This paper present experimental test results of punching shear strength of concrete bridge decks with LB-DECKs. Six full-scaled concrete bridge decks, which are designed with the empirical design method, are fabricated with variation of girder spacings. Test results are presented in the paper and compared with the code predictions of ACI 318, CEB-FIP MC90. Based on the test results, it is proposed that LB-DECK is suitable to apply the empirical design method for concrete bridge decks.

  • PDF

An Evaluation on Punching Shear Capacity of R/C Flat Plate Slab (RC 플랫 플레이트 슬래브의 뚫림전단성능평가)

  • Kim, Jong-Keun;Shin, Sung-Woo;Yang, Ji-Soo;Lee, Li-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.3
    • /
    • pp.205-213
    • /
    • 2003
  • The primary purpose of this study is to investigate punching shear capacity of flat plate slab using high strength concrete in column. It may be much contributed to economy efficiency and structural advantages that High Strength Concrete(HSC) used for vertical member and Normal Strength Concrete(NSC) for horizontal member. Therefore, six plate flat slab specimens with HSC column and NSC slab had been made and tested with real scale. The major variables were compressive strength of concrete(fck=285, $460kgf/cm^2$), extended length of HSC from column face and amount of shear reinforcements. As the result of this test, the maximum load and punching shear capacity of specimens is affected by extended length and shear reinforcements.

Punching Shear Strength of the Void Transfer Plate (중공 전이 슬래브의 뚫림 전단 강도)

  • Han, Sang-Whan;Park, Jin-Ah;Kim, Jun-Sam;Im, Ju-Hyeuk;Park, Young-Mi
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.367-374
    • /
    • 2010
  • The transfer slab system is a structural system that transfers the loads from the upper shear wall structure to the lower columns. This is a costly system due to a very thick slab, and the relatively high cost can be mitigated by introducing voids in the slab. However, this system of flat plate containing voids is vulnerable to brittle failure caused by punching shear in vicinity of slab-column connection. Thus, the punching shear capacity of the void system is very important. However, the current code doesn't provide a clear design provision for the strength of slabs with a void section. In this study, experimental study was conducted to investigate the punching shear strength of the void slab system. The shear strength of the specimens was predicted by current code and previous researches. In result, the punching shear strength of the void system is determined as the least value calculated at critical section located a distance d/2 from the face of the column and the center of the void section using the effective area at critical section.

Punching Shear Behavior of High-strength Lightweight Concrete Slab Under Concentrated Load (집중하중을 받는 고강도 경량콘크리트 바닥판의 펀칭전단 거동)

  • Cho, Sun-Kyu;Kwark, Jong-Won;Lee, Jong-Min;Moon, Dae-Joong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.219-228
    • /
    • 2006
  • Because of the advantage of light weight, lightweight concrete is frequently applied to long-span bridges and high-rise buildings. In the country, there is not enough experience for the long-span bridges using lightweight concrete. This paper presents results of an experimental study on the punching shear strength of high-strength lightweight concrete slabs. Four test slabs are fabricated using high-strength lightweight concrete and normalweight concrete and at the center of the test slabs, simulated wheel load is applied until failure. The compressive strengths of lightweight concrete and normalweight concrete are 47MPa and 32MPa, respectively. The test results show the failure mode of all specimens are punching shear and the behaviors of high-strength lightweight concrete slabs are very similar to that of normalweight concrete slabs. Based on the test results, it is discussed the safety and serviceability of high-strength lightweight concrete bridge decks.

A Study on the Structural Characteristic of Strengthened Bridge Deck Specimens Using External Bonded Plate (Plate로 전면보강된 교량 상판의 거동특성에 관한 연구)

  • 심종성;오홍섭;김언경
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.163-168
    • /
    • 2001
  • Punching shear in concrete slabs is a serious problem in certain structural systems, such as flat slab. In this study, mechanical improvement between specimens which are unstrengthened and strengthened with steel plate and fiber panel is experimentally investigated. The strengthened bridge deck specimens had increment of strength and broke down with punching shear failure. Strengthening ratio should be considered to restraint punching failure.

  • PDF

Punching Shear Strength Prediction of Slabs by Analysis of Existing Data (기존 Data 분석에 의한 슬래브의 편칭전단강도 예측)

  • Kim, Jae-Min;Kim, Dae-Joong;Mo, Gui-Seok;Kim, Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.373-376
    • /
    • 1999
  • The techniques of dimensional analysis and statistical regression analysis is applied to existing voluminous data available from tests covering a wide range of slab properties, which then leads to an equation to predict the punching shear strength of slabs.

  • PDF

Experimental Study for Concrete Base to Sleeve connection of Hybrid Substructure for Offshore Wind Turbine (하이브리드 해상풍력발전 지지구조물의 콘크리트 베이스-슬리브 연결부에 대한 실험 연구)

  • Lee, Jeong-Hwa;Byun, Nam-Joo;Kim, Seong-Hwan;Park, Jae-Hyun;Kang, Young-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.79-87
    • /
    • 2016
  • In this paper, concrete base to sleeve connections of hybrid substructures for offshore wind turbines were suggested and investigated experimentally. Punching shear strength tests with well-instrumented three connections under different reinforcement ratios and loading conditions were conducted to investigate the punching shear strength and the behavior of the concrete base to a sleeve connection. The test results showed that the punching strength and stiffness of the connections are affected mainly by the reinforcement ratios. The loading conditions with an axial load and proportional moment cannot affect the stiffness but affect the strength of the connections because of the axial load-moment interaction. The punching shear failure and critical section of the each test specimen are also discussed.

Dynamic punching shear tests of flat slab-column joints with 5D steel fibers

  • Alvarado, Yezid A.;Torres, Benjamin;Buitrago, Manuel;Ruiz, Daniel M.;Torres, Sergio Y.;Alvarez, Ramon A.
    • Structural Engineering and Mechanics
    • /
    • v.81 no.3
    • /
    • pp.281-292
    • /
    • 2022
  • This study aimed to analyze the dynamic punching shear performance of slab-column joints under cyclic loads with the use of double-hooked end (5D) steel fibers. Structural systems such as slab-column joints are widely found in infrastructures. The susceptibility to collapse of such structures when submitted to seismic loads is highly dependent on the structural performance of the slab-column connections. For this reason, the punching capacity of reinforced concrete (RC) structures has been the subject of a great number of studies. Steel fibers are used to achieve a certain degree of ductility under seismic loads. In this context, 5D steel hooked fibers provide high levels of fiber anchoring, tensile strength and ductility. However, only limited research has been carried out on the performance under cyclic loads of concrete structural members containing steel fibers. This study covers this gap with experimental testing of five different full-scale subassemblies of RC slab-column joints: one without punching reinforcement, one with conventional punching reinforcement and three with 5D steel fibers. The subassemblies were tested under cyclic loading, which consisted of applying increasing lateral displacement cycles, such as in seismic situations, with a constant axial load on the column. This set of cycles was repeated for increasing axial loads on the column until failure. The results showed that 5D steel fiber subassemblies: i) had a greater capacity to dissipate energy, ii) improved punching shear strength and stiffness degradation under cyclic loads; and iii) increased cyclic loading capacity.

An Experimental Study on the Punching Shear of Slab with Polystyrene Form (폴리스티렌 폼을 사용한 슬래브의 뚫림전단에 관한 실험적 연구)

  • Lee, Hwan-Gu;Kim, Seung-Hun;Kang, In-Suk;Lee, Han-Seung;Lee, Ki-Jang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.213-216
    • /
    • 2008
  • When using the light-weight form with polystyrene on slab, as a result of reducing the weight of slab, the span was increased or size of supporting member for slab was decreased. But capacity of punching shear resistance on the slab using the polystyrene form with plat plate system was deteriorated at critical section around the column. But standard for estimate of internal force did not exist, and established study was insufficient. This study performed the experiment on the punching shear for understanding punching shear force at the slab-column connection using the slab with polystyrene form. The principal variable was size of column, arrangement of polystyrene form and existence of shear reinforcement, and we planned four specimens. From the test, we analysed the crack, failure mode, road-displacement graph and punching shear strength, and capacity of punching shear resistance for slab using the polystyrene form was understood.

  • PDF

Strategic Utilization of Fiber Reinforced UHSC in Slab-Column Connections

  • Yoon, Young-Soo;Lee, Joo-Ha;Lee, Seung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.79-82
    • /
    • 2005
  • This study reports on the structural characteristics of slab-column connections using an ultra-high-strength-fiber-reinforced concrete from new and retrospective data. The parameters investigated were the ' puddling ' of ultra-high-strength-fiber-reinforced concrete and the use of high-strength concrete in the slab. The effects of these parameters on the punching shear capacity, negative moment cracking, and stiffness of the two-way slab specimens are investigated. Furthermore, the ACI Code (2002), the CSA Standard (1994), the BS Standard (1985) and the CEB-FIP Code (1990) predictions are compared to the experimental results obtained from some slab-column connections tested in this experiment and those tested by other investigators. The beneficial effects of the ultra-high-strength-fiber-reinforced concrete puddling and of the use of high-strength concrete are demonstrated. It is also concluded that the punching shear strength of slab-column connections is a function of the flexural reinforcement ratio.

  • PDF