• 제목/요약/키워드: pumping time

검색결과 305건 처리시간 0.024초

피지옴 모델을 이용한 심실의 전기활성시간 분포에 따른 심박출 성능평가 (Estimation of Cardiac Pumping Performance according to the Ventricular Electrical Activation Time Distribution by Using Physiome Model)

  • 김형균;임기무
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.198-203
    • /
    • 2015
  • The purpose of the study is to examine the effects of pacemaker location on cardiac pumping efficacy theoretically. We used a three-dimensional finite element cardiac electromechanical model of canine ventricles with models of the circulatory system. Electrical activation time for normal sinus rhythm and artificial pacing in apex, left ventricular free wall, and right ventricular free wall were obtained from electrophysiological model. We applied the electrical activation time maps to the mechanical contraction model and obtained cardiac mechanical responses such as myocardial contractile ATP consumption, stroke work, stroke volume, ejection fraction, and etc. Among three artificial pacing methods, left ventricle pacing showed best performance in ventricular pumping efficacy.

Effect of constraint severity in optimal design of groundwater remediation

  • Ko, Nak-Youl;Lee, Kang-Kun
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.217-221
    • /
    • 2003
  • Variation of decision variables for optimal remediation using the pump-and-treat method is examined to estimate the effect of the degree of concentration constraint. Simulation-optimization method using genetic algorithm is applied to minimize the total pumping volume. In total volume minimization strategy, the remediation time increases rapidly prior to significant increase in pumping rates. When the concentration constraint is set severer, the more wells are required and the well on the down-gradient direction from the plume hot-spot gives more efficient remediation performance than that on the hot-spot position. These results show that the more profitable strategy for remediation can be achieved by increasing the required remediation time than raising the pumping rate until the time reaches a certain limitation level. So, the remediation time has to be considered as one of the essential decision variables fer optimal remediation design.

  • PDF

초고층 구조물 시공을 위한 고성능 콘크리트의 펌프압송 기술에 관한 실험적 연구 (An Experimental Study on the Concrete Pumping Technology of High Performance Concrete for the High-Rise Building Construction)

  • 김규동;한천구
    • 한국건축시공학회지
    • /
    • 제15권4호
    • /
    • pp.375-381
    • /
    • 2015
  • 본 연구에서는 초고층 구조물 시공시, 적용되는 규격별 고성능 콘크리트의 특성을 평가하고 60MPa의 고성능 콘크리트를 대상으로 높이가 500m부터 575m인 지점까지 압송계측 결과를 근거로 하여 압송성능과 고성능 콘크리트의 유동특성의 상관관계를 분석하였다. 분석 결과, 각 규격별 굳지 않은 콘크리트의 물성과 재령 12시간의 초기강도 및 기준 재령에서의 압축강도 및 탄성계수는 모두 품질기준을 만족함이 확인되었다. 또한, 높이별 최대 압송압력은 약 5% 정도씩 증가하였으며, 시간당 토출량도 최소 $25m^3$를 만족하는 것으로 나타났다. 펌프압송 후 콘크리트의 온도증가와 압송전의 콘크리트 소성점도의 크기에 따라 슬럼프 플로우의 손실이 증가됨을 확인할 수 있었다.

먹는샘물 제조업체의 취수량 및 감시정 관리에 관한 고찰 (A Study on the Water Withdrawal Permit Rate and Monitoring Well Management of Bottled Water Manufacturers)

  • 손두기;박승혁;정교철
    • 지질공학
    • /
    • 제29권3호
    • /
    • pp.329-337
    • /
    • 2019
  • 샘물개발허가의 유효기간은 5년이며, 연장허가를 위하여 만료 6개월 전까지 샘물환경영향조사 보고서를 첨부하여 기간 연장을 신청하여야 한다. 제출된 보고서의 심사과정에서 가장 큰 관심은 샘물 취수에 따른 지하수위 강하, 원수 수질분석 및 감시정의 모니터링 결과에 집중된다. 중생대 백악기 지역과 선캠브리아기 변성암 지역에 각각 위치하는 먹는샘물 제조업체의 취수정에 대하여 수중모터펌프의 양수능력과 양수시간을 조절하는 방법으로 수위강하량과의 상관성을 조사하였다. 양수능력을 감소시키는 방법이 매시간 동일하게 양수시간과 회복시간을 조정하는 방법보다 수위강하량을 줄이는데 효과적이었다. 또한 변성암 지역에 설치한 감시정에 대하여 pH센서의 계측자료를 분석한 결과, 설치 후 경과시간에 따라 계속 증가하여 일정한 값에 수렴하는 것으로 조사되어 관리가 어려운 pH항목을 감시정에서 제외하거나 사용자 친화적인 계측방법으로 보완이 필요할 것으로 판단된다.

지하수 히트펌프 시스템의 대수층 활용 사레 연구 (Study on the aquifer utilization for a ground water heat pump system)

  • 심병완;이철우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.32-35
    • /
    • 2006
  • The validation of a groundwater source heat pump system installation site is estimated by bydrogeothermic model ing. The hydraulic characteristics of the aquifer system is evaluated from pumping and recovery tests. In addition, the temperature distribution by the pumping and the injection of groundwater, and water level fluctuations are simulated by numerical modeling. The total cooling and heating load for the building is designed as 120RT(refrigeration ton) and the ground water source heat pump system covers 50RT as a subsidiary system The scenario of heat pump operation is organized as pumping and inject ion of groundwater that is performed for 8 hours per day in cooling mode for 90 days during the summer season The heat transfer by the injected warm water is limited near the inject ion wells in the simulated temperature distribution. The reason is that the given operation time is too short to expect broad thermal diffusion in large volume of the aquifer in the simulation time The simulated groundwater level and temperature distribution can be used as important data to develope an energy effective pumping and injection well system. Also it will be very useful to evaluate the hydraulic capacity of a target groundwater reservoir.

  • PDF

Estimating Groundwater Level Change Associated with River Stage and Pumping using Time Series Analyses at a Riverbank Filtration Site in Korea

  • Cheong, Jae-Yeol;Hamm, Se-Yeong;Kim, Hyoung-Soo;Lee, Soo-Hyoung;Park, Heung-Jai
    • 한국환경과학회지
    • /
    • 제26권10호
    • /
    • pp.1135-1146
    • /
    • 2017
  • At riverbank filtration sites, groundwater levels of alluvial aquifers near rivers are sensitive to variation in river discharge and pumping quantities. In this study, the groundwater level fluctuation, pumping quantity, and streamflow rate at the site of a riverbank filtration plant, which produces drinking water, in the lower Nakdong River basin, South Korea were interrelated. The relationship between drawdown ratio and river discharge was very strong with a correlation coefficient of 0.96, showing a greater drawdown ratio in the wet season than in the dry season. Autocorrelation and cross-correlation were carried out to characterize groundwater level fluctuation. Autoregressive model analysis of groundwater water level fluctuation led to efficient estimation and prediction of pumping for riverbank filtration in relation to river discharge rates, using simple inputs of river discharge and pumping data, without the need for numerical models that require data regarding several aquifer properties and hydrologic parameters.

Understanding Hydrogeologic Characteristics of a Well Field of Pyosun in Jeju Volcanic Island of Korea

  • Lee, Jin-Yong;Lee, Gyu-Sang;Song, Sung-Ho
    • 한국지구과학회지
    • /
    • 제29권5호
    • /
    • pp.396-407
    • /
    • 2008
  • Hydrogeologic properties of a well field around middle mountainous areas in Pyosun, Jeju volcanic island were examined based on water level monitoring, geologic logging and pumping test data. Due to the alternating basaltic layers with varying permeability in the subsurface, it is difficult to analyze the hydraulic responses to artificial pumping and/or natural precipitation. The least permeable layer, detrital materials with clay, is found at a depth of 200 m below surface, but it is not an upper confining bed for lower main aquifer. Nevertheless, this layer may serve as a natural barrier to vertical percolation and to contaminant migration. Water levels of the production wells are dominantly affected by pumping frequently, while those of the remote observation wells are controlled by ambient precipitation. Results of pumping tests revealed a possible existence of horizontal anisotropy of transmissivity. However, some results of this study include inherent limitations enforced by field conditions such as the consistent of groundwater production and the set of time periods for the cessation of the pumping prior to pumping tests.

VALVELESS PUMPING IN OPEN TANK SYSTEM USING ENERGY CONSERVING COMPARTMENT MODEL

  • Jung, Eun-Ok;Kim, Do-Wan
    • 대한수학회보
    • /
    • 제49권5호
    • /
    • pp.961-987
    • /
    • 2012
  • A compartment model of the flow driven by pumping without valves (valveless pumping) in an open tank system is proposed. By the open tank system, we mean that two rigid cylindrical tanks are connected with an elastic tube. An incompressible fluid fills this system up to a certain level in tanks under the gravity. The compartment model for analyzing such open system is derived from the energy principle which will be called the energy conserving compartment model or shortly the ECCM. Based on this ECCM of valveless pumping, we explore the occurrence of directional net flow or directional net power by a specific excitation at an asymmetric part of the elastic tube. The interaction between deformable elastic tube and the fluid inside is considered in the ECCM. The reliability of the ECCMis investigated through some physical examples. The ECCM shows the existence of directional net power of the valveless pump system with open tanks and confirms that the direction and magnitude of the net power depend on the pumping frequency as well. Furthermore, the phase synchronization in time between the fluid pressure difference and the external pinching force over the pumping region is highly related to the direction of energy storing or net power.

비선형 에크만 분출 모델 (Non-Linear Ekman Pumping Model)

  • 박재현;김정환;김동균;배석태;김정렬
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.305-306
    • /
    • 2006
  • Developed in this study is a nonlinear Ekman pumping model to be used in simulating the rotating flows with quasi-three-dimensional Navier-Stokes equations. In this model, the Ekman pumping velocity is given from the solution of the Ekman boundary-layer equations for the region adjacent to the bottom wall of the flow domain; the boundary-layer equations are solved in the momentum-integral form. The developed model is then applied to rotating flows in a rectangular container receiving a time-periodic forcing. By comparing our results with the DNS and experimental data we have validated the developed model. We also compared our results with those given from the classical Ekman pumping model. It was found that our model can predict tile rotating flows more precisely than the classical linear model.

  • PDF

비선형 Ekman 펌핑 모델의 개발 (Development of a Nonlinear Ekman Pumping Model)

  • 서용권;박재현
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.568-577
    • /
    • 2006
  • Developed in this study is a nonlinear Ekman pumping model to be used in simulating the rotating flows with quasi-three-dimensional Navier-Stokes equations. In this model, the Ekman pumping velocity is given from the solution of the Ekman boundary-layer equations for the region adjacent to the bottom wall of the flow domain; the boundary-layer equations are solved in the momentum-integral form. The developed model is then applied to rotating flows in a rectangular container receiving a time-periodic forcing. By comparing our results with the DNS and experimental data we have validated the developed model. We also compared our results with those given from the classical Ekman pumping model. It was found that our model can predict the rotating flows more precisely than the classical linear model.