• Title/Summary/Keyword: pump station

Search Result 123, Processing Time 0.023 seconds

Determination of Optimal Operation Water Level of Rain Water Pump Station using Optimization Technique (최적화 기법을 이용한 빗물펌프장 최적 운영수위 결정)

  • Sim, Kyu-Bum;Yoo, Do-Guen;Kim, Eung-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.337-342
    • /
    • 2018
  • A rain water pumping station is a structural countermeasure to inland flooding of domestic water generated in a urban watershed. In this study, the optimal operation water level of the pump with the minimum overflow was determined based on the opinions of the person in charge of the operation of the rain water pump station. A GA (Genetic Algorithm), which is an optimization technique, was used to estimate the optimal operation water level of the rain water pump station and was linked with SWMM (Ver.5.1) DLL, which is a rainfall-runoff model of an urban watershed. Considering the time required to maximize the efficiency of the pump, the optimal operating water level was estimated. As a result, the overall water level decreased at a lower operating water level than the existing water level. For most pumps, the lowest operating water level was selected for the operating range of each pump unit. The operation of the initial pump could reduce the amount of overflow, and there was no change in the overflow reduction, even after changing the operation condition of the pump. Internal water flooding reduction was calculated to be 1%~2%, and the overflow occurring in the downstream area was reduced. The operating point of the pump was judged to be an effective operation from a mechanical and practical point of view. A consideration of the operating conditions of the pump in future, will be helpful for improving the efficiency of the pump and to reducing inland flooding.

CFD Prediction on Vortex in Sump Intake at Pump Station (펌프 흡수정내 발생된 보텍스에 대한 CFD 예측)

  • Park, Sang-Eun;Roh, Hyung-Woon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.4
    • /
    • pp.39-46
    • /
    • 2007
  • In large pump station, vortex generation such as free-surface vortex and submerged vortex occurring around pump intake, or at bell-mouth inlet has been an important flow characteristics which should be considered always to keep away the suction of air-entrained or cavitated flow. In this study, a commercial CFD code was used to predict accurately the vortex generation for the specified intake design. These result shows the preliminary result of submerged vortex prediction for the Turbo-machinery Society of Japan Sump Test CFD standard model. At bottom wall, air volume fraction (red color) was found in a large scale to explain the submerged vortex generation at particular operation and configuration condition. And these indicate the free surface formation behind the bell mouth. Particularly, non-uniform approaching flow is a major parameter to govern the occurrence of the free-surface vortex. Futhermore the comparison between turbulence ($k-{\epsilon}$ & $k-{\omega}$ model) mode were executed in this study.

A Study on Real-Time Operation Method of Urban Drainage System using Data-Driven Estimation (실시간 자료지향형 예측을 활용한 내배수 시설 운영기법 연구)

  • Son, Ahlong;Kim, Byunghyun;Han, Kunyeun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.6
    • /
    • pp.949-963
    • /
    • 2017
  • This study present an efficient way of operating drainage pump station as part of nonstructural measures for reducing urban flood damage. The water level in the drainage pump station was forecast using Neuro-Fuzzy and then operation rule of the drainage pump station was determined applying the genetic algorithm method based on the predicted inner water level. In order to reflect the topographical characteristics of the drainage area when constructing the Neuro-Fuzzy model, the model considering spatial parameters was developed. Also, the model was applied a penalty type of genetic algorithm so as to prevent repeated stops and operations while lowering my highest water level. The applicability of the development model for the five drainage pump stations in the Mapo drainage area was verified. It is considered to be able to effectively manage urban drainage facilities in the development of these operating rules.

Waterhammer in Transmission Pumping Station with Ball Valve (볼밸브를 사용한 송수펌프장에서의 수격현상)

  • Kim, Kyung-Yup;Kim, Joum-Bea
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1697-1702
    • /
    • 2004
  • The waterhammer has recently become more important because the pumping stations were big and the systems conveying the fluid through the large and long transmission pipelines were complex. When the pumps are started or stopped for the operation or tripped due to the power failure. the hydraulic transients occur as a result of the sudden change in velocity. In this paper, the field tests on the waterhammer by the startup, stoppage, and power failure of a centrifugal pump were carried out for Yongma transmission pumping station in Seoul. The experimental results were compared with that of the numerical calculations. in which results the procedure of controlled pump normal shut-down and the two-step closing mode of controlling the ball valve for pump emergency stop are proposed to reduce the pressure surge.

  • PDF

Improvement and Application of Pump Station Operating System and Economic Analysis of the Application (빗물펌프장 운영시스템 개선 및 적용과 경제효과분석)

  • Joo, Jin- Gul;Yoo, Do-Guen;Yang, Jae-Mo;Jung, Dong-Hwi;Kim, Joong-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • In low-lying districts of urban areas, pump stations were built to protect flooding by the heavy rain. Particularly, the automatic pump operation system was installed for efficiency in the pump stations of Seoul. However, the effective pump operation is difficult under existing operating system because the system only performs operation by reservoir depth. This study would like to improve the real time operating system suggested by Jun et al.(2007) and to apply the system Gasan 1 pump station in Seoul. For various design rainfall events, maximum water levels simulated by the suggested system were 10~70cm lower than results by the existing system. And overflow volume at upstream manholes were 50% reduced. We converted the flood control effects by establishment of the suggested system to economic indicators. To obtain the same effect, approximately 4.9 billion won needs to expand pump capacities or 3.2~6.9 hundreds million won needs to construct storm water detention on upstream area. The suggested system could improve the flood control stability by efficient operation of the existing pump station.

Design of Multi-Regional Water Supply System Based on the Optimization Technique (최적화 기법을 이용한 광역상수도 관로시스템 설계)

  • Kim, Ju Hwan;Kim, Zong Woo;Park, Jae Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.95-112
    • /
    • 1999
  • In this research, it is proposed that optimization method is introduced and applied to the design of pipeline system in multi-regional water supply project, which has been constructed to settle the regional unbalance problems of available water resources. For the purpose, interface programs are developed to integrate linear programming model and KYPIPE model which is used for optimization and hydraulic analysis, respectively. The developed program is applied to the pipeline system design of multi-regional water supply project. The optimal diameters from the application of linear programming technique are compared with those from conventional method that is time-consuming and tedious trail and error process. Since the conventional design largely depends upon the experience of designers and the results of general hydraulic analysis, it can not be reasonable and consistent. The application of linear programming technique can make it possible to design pipeline system optimally by using same design factors of general hydraulic models. The model can select commercial discrete pipe diameter as optimal size by using pipe length as decision variables. The developed model is applied to Pohang multi-regional water supply system design with two different objective functions, which are initial construction cost and annual cost including electric cost. As results, it is calculated that the initial construction cost of 1,449,740 thousand won is saved and annual cost of 128,951 thousand won is saved for a year within study year. Also, the optimal site of pump station is selected on 5th pipe, which is located between the diverging junction to Kangdong(2) province and the diverging junction to Cheonbuk province. It is explained that pump cost is less than pipe cost in this application case study due to little pump station scale. In the case of water supply with large pump capacity, it is reasonal that the increase of pipe size is more efficient instead the increase of pump station capacity to save annual cost.

  • PDF

An Experimental Study on Standard Establishment of Sump Model Test in Pump Station (펌프장 Sump 모델 시험기준 수립을 위한 실험 연구)

  • Lee, L.Y.;Kim, B.S.;Lee, D.G.;Oh, Y.M.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.582-588
    • /
    • 2005
  • An experimental study to establish a standard of sump model test of pump station was implemented. Comparison of foreign standard was also performed. Configuration condition around a bell mouth suction intake was easily adjusted by 3-axis traversing system and partition allocation. Operational condition was also varied widely to give accurate test data. PIV was also introduced to produce Quantitative analysis of flow field such as free-surface vortex and submerged vortex occurring in the model test. More detailed vortex behaviors were represented by PIV analysis.

  • PDF

Design of Detention Pond and Critical Duration of Design Rainfall in Seoul

  • Lee, Jong-Tae;Yoon, Sei-Eui;Lee, Jae-Joon
    • Korean Journal of Hydrosciences
    • /
    • v.5
    • /
    • pp.33-43
    • /
    • 1994
  • This study is to determine the critical duration of design rainfall and to utilize it for the design of detention pond with pump station. To examine the effect of the duration and temporal distribytion of the design rainfall, Huff's quartile method is used for the 9 cases of durations (ranges from 20 to 240 minutes) with ten years return period, and the ILLUDAS model is used for runoff analysis. The storage ratio, which is the ratio of maximum storage amounts to total runoff volume, is introduced to determine the criticalduration of design rainfall. The duration which maximizes the storage ratio is adopted as the critical duration. This study is applied to 18 urban drainage watercheds with pump station in Seoul, of which the range of watershed area is 0.24~12.70$km^2$. The result of simulation shows that the duration which maximizes storage ratio is 30 and 60 minutes on the whole. It is also shown that the storage ratios of 2nd - and 3rd-quartile pattern are larger than those of 1st- and 4th-quartile pattern of temporal distribution. A simplified empirical formula for Seoul area is suggested by the regression analysis between the maximum storage ratio and the peak ratio. This formula can be utilized for the preliminary design and planning of detention pond with pump station.

  • PDF

Effect of Design Factors in a Pump Station on Pressure Variations by Water Hammering (가압 펌프장에서 설계인자들이 수격에 의한 압력변동에 미치는 영향)

  • Park, Jong-Hoon;Sung, Jaeyong
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.15-27
    • /
    • 2021
  • In this study, the effect of design factors in a pump station on the pressure variations which are the main cause of water hammering has been investigated by numerical simulations. As design factors, the flow rate, Young's modulus, diameter, thickness, roughness coefficient of pipeline are considered. The relationships between the pressure variations and the design factors are analyzed. The results show that the pressure variation increases sensitively with the flow rate and Young's modulus, and increases gradually with the thickness and roughness coefficient of pipe, whereas it decreases with the pipe diameter. The wavelength of the pressure wave becomes longer for a smaller Young's modulus, a smaller pipe thickness and a bigger pipe diameter. These relationships are nondimensionalized, and logarithmic curve-fitted functions are proposed by regression analysis. Most effective factors on the nondimensional pressure variation is Young's modulus. Flow rate, roughness coefficient, relative thickness and pipe diameters are the next impact factors.

Study on Performance Analysis of Pump within Sump Model with AVD installation by CFD (CFD에 의한 와류방지장치(AVD)가 설치된 흡수정내 펌프의 성능평가에 관한 연구)

  • Choi, Jong-Woong;Park, No-Suk;Kim, Seong-Su;Park, Sang-Su;Lee, Young-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.463-469
    • /
    • 2012
  • The efficiency of the flow mixed pump installed within the bell-mouth in the sump is reduced by the flow characteristics of around intakes. Strong submerged vorticies can be successfully suppressed by installing an AVD(anti-submerged vortex device) on the bottom of pump intake channel just below the bell-mouth. Sump model with AVD device basin is designed and the characteristics of submerged vortex is investigated in the flow field by numerical simulation. In this study, a commercial CFD code is used to predict the efficiency of the pump with the AVD installation in the pump station accurately.