• 제목/요약/키워드: pump simulation test

검색결과 113건 처리시간 0.021초

On-site Performance Test and Simulation of a 10 RT Air Source Heat Pump

  • Baik, Young-Jin;Chang, Young-Soo;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권2호
    • /
    • pp.61-69
    • /
    • 2004
  • In this study, on-site performance test of an air source heat pump which has a rated capacity of 10 RT is carried out. Since indoor and outdoor air conditions can not be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist. To estimate the performance of the heat pump for other conditions, the heat pump is modeled with a small number of characteristic parameters. The values of the parameters are determined from the few measurements measured on-site during steady operation. A simulation program is developed to calculate cooling capacity and power consumption at any other arbitrary operating conditions. The simulation results are in good agreement with the experiment. This study provides a method of an on-site performance diagnosis of an air source heat pump.

영상처리 기법에 의한 합섬방사용 미터링 펌프의 시뮬레이션 소프트웨어 개발 (Development of Simulation Software for Metering Pump of Synthetic Fibers with Image Processing)

  • 조연상;배명호
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.101-106
    • /
    • 2005
  • It needs to accumulate a store of know-how on the design, precision processing and appraisement for metering pump which is a kind of gear pump fer synthetic fibers. But the period and cost fur development is not effective, because designers experience many trial and error for the pump design and manufacturing process. Therefore, in order to curtail the period and cut down expenses, the analysis and simulation system is required for a designed metering pump. In this study, the pump simulation software was developed with the visual C++ language and the image processing algorithm, and was investigated through a discharge test for the planetary gear type metering pump.

CFD모사 기법을 이용한 Pump Diffusion Mixer내의 응집체 확산분포에 대한 평가 (Evaluation of Coagulants Dispersion in Pump Diffusion Mixer for Water Treatment)

  • 박영오;박노석;김성수;김기돈;임경호
    • 상하수도학회지
    • /
    • 제22권1호
    • /
    • pp.49-63
    • /
    • 2008
  • The objectives of this research were to evaluate the pressurized/the main inlet water flowrate ratio which have been used as the most important parameter for operating the pump diffusion mixer until now, to suggest the alternative operating parameter and the relating criteria if the flowrate ratio was not inadequate. For the objectives of this research, computational fluid dynamics (CFD) simulation was conducted for 21 cases of flowrate ratio in full-scaled pump diffusion mixer. From the results of CFD simulation, the local velocity gradient values were calculated in each case in order to analyze the simulation results in more detail. For verifying CFD simulation, wet test was conducted. The wet test was to measure the factual coagulant dispersion distribution at a distance of 5.4m from deflector. From both results of CFD simulation and wet test, flowrate ratio was inadequate as operating parameter or criteria, on the other hand the pressurized/the main inlet velocity ratio(dimensionless) was useful in predicting the performance of pump diffusion mixer. Also, the injected coagulant could be dispersed evenly in overall cross section on the condition that pressurized/the main inlet velocity ratio(dimensionless) is over at least 20.

10RT급 공기열원 열펌프의 현장 성능측정 및 예측 (In-situ Performance Test and Prediction of a 10 RT Air Source Heat Pump)

  • 김영일;백영진;장영수
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.221-230
    • /
    • 2002
  • In this study, in-situ performance test of an air source heat pump which has a arted capacity of 10 RT is carried out. Since test conditions, such as indoor and outdoor air conditions cannot be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist. To estimate the performance for other conditions, he heat pump is modeled with a small number of selected parameters. The values of the parameters are determined from the few measurements measured on-site during normal operation. A simulation program is developed to calculate cooling capacity and power consumption t any other operating conditions. The simulation results are in good agreement with the experiment. This study provides a method of an on-site performance diagnosis of an air source heat pump.

외장형 연료펌프를 사용한 LPLi시스템에서 연료의 상태량 변화 예측 (Prediction of Fuel Properties on LPLi System with an External Fuel Pump)

  • 김재형;윤여빈;박영준;송춘섭;이성욱;조용석
    • 한국분무공학회지
    • /
    • 제15권1호
    • /
    • pp.38-43
    • /
    • 2010
  • The LPG(Liquefied Petroleum Gas) fuel attracts attention as a clean alternative fuel. In order to further reduce the exhaust emission and improve performance in LPG engines, the LPLi(Liquid Phase LPG Injection) system is used. In LPLi system, the fuel pump performance is important for keeping the LPG over it's saturated vapor pressure. An external fuel pump is needed to improve the durability for LPG engines. This paper predicted the variation of fuel properties on the LPLi system with an external fuel pump. From each component's thermodynamic model, an 1-D simulation is developed for LPLi system with an external fuel pump. Then the 1-D simulation data analyzed and compared with the rig-test. The 1-D simulation and the rig-test produced similar results.

Similarity evaluation of the pump simulation loop in STELLA-2 for conservation of mechanical sodium pump characteristics

  • Jung Yoon ;Jewhan Lee ;Jaehyuk Eoh;Hyungmo Kim ;Dong Eok Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.353-363
    • /
    • 2023
  • The STELLA-2 is a large-scale sodium thermal-hydraulic integral effect test facility and supports the development of PGSFR. The facility adopted Pump Simulation Loop System (PSLS) concept for the mechanical sodium pump in the reference reactor to control and to measure the primary sodium flow. Since the component (mechanical pump) is replaced by the loop, it is very important to evaluate the similarity between the pump and the loop. In this paper, to simulate the characteristic of the mechanical sodium pump, the pressure loss along the various options of the loop was evaluated and the comprehensive validity of each design options was analyzed. Using the similarity criteria based on the Richardson number and Euler number conservation, the PSLS design was finalized and the result was within the acceptable error range. Finally, the result of this study was used for construction of the overall facility, STELLA-2.

터보펌프 조립체-가스발생기 연계 개회로 시험에서의 시동특성 분석 (Analysis of Startup Characteristics for Turbo Pump Unit-Gas Generator Open Loop Test)

  • 문윤완;김승한;설우석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.15-18
    • /
    • 2008
  • 본 연구에서는 터보펌프 조립체-가스발생기 연계시험 중 개회로 시험에 대한 시동 특성을 분석하였고 수치적으로 해석하였다. 시험에서 터빈의 시동 및 구동은 수소 기체로 수행하였고 그에 따른 가스발생기 점화 및 연소압의 발달을 살펴보았고 해석도 동일한 조건으로 수행하여 결과를 비교하였다. 회전수의 발달 특성은 시험과 잘 일치하는 것을 볼 수 있었고 가스발생기 연소압 발달 특성의 경우 정성적인 기울기가 일치하는 것을 볼 수 있었다.

  • PDF

터보펌프 조립체-가스발생기 연계 폐회로 시험에서의 시동특성 분석 (Analysis of Startup Characteristics for Turbo Pump Unit-Gas Generator Closed Loop Test)

  • 문윤완;김승한;설우석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.19-22
    • /
    • 2008
  • 본 연구에서는 터보펌프 조립체-가스발생기 연계시험 중 폐회로 시험에 대한 시동 특성을 분석하였고 수치적으로 해석하였다. 시험에서 터빈의 시동은 수소 기체로 수행하였고 구동은 가스발생기에서 연소로 발생하는 연소 기체로 작동하였다. 그에 따른 가스발생기 점화 및 연소압의 발달을 살펴보았고 해석도 동일한 조건으로 수행하여 결과를 비교하였다. 회전수의 발달 특성은 시험과 잘 일치하는 것을 볼 수 있었고 가스발생기 연소압 발달 특성의 경우 정성적으로 일치하는 것을 볼 수 있었다.

  • PDF

2중열원 히트펌프시스템의 냉방성능예측에 관한 연구 (Cooling Performance Evaluation study of Dual-Source Heat Pump System)

  • 노관종;김지영;강은철;박희문;이의준
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권1호
    • /
    • pp.1-9
    • /
    • 2007
  • A steady-state simulation model for Dual-Source Heat Pump(DSHP) of 8RT was presented. A Dual-Source Heat Pump(DSHP) has been designed to make up for the conventional air source heat pumps. The performance evaluation has been conducted under internal standard test conditions such as ISO-13256-1 and KS C 9306. However, as test conditions such as entering water, indoor and outdoor air conditions could not be controlled to satisfy the standard test conditions in outdoor tests, a series of experiments have been conducted with the actual test conditions. Then, computer models for DSHP could be used for the standard condition have developed using EES program. The model was developed from basic thermodynamic principles and heat transfer relations. Most of the parameters were obtained with EES from the actual catalog data. The simulation results were in good agreement with the experiments.

  • PDF

SUDS증발기를 사용한 2중열원 열펌프의 성능해석 (Performance analysis of dual source heat pump system with single unit dual source evaporator)

  • 우정선;이세균;이재효;박효순
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.391-400
    • /
    • 1999
  • The efficiency and capacity of an air source heat pump system decrease as the ambient temperature drops. One strategy of avoiding the decrease of the efficiency and capacity in air source heat pump system is to switch to another thermal energy source. Water can be a good candidate for the heat source. This paper presents the results of the performance analysis of heat pump system with a single unit dual source(SUDS) evaporator The heat exchanger combines two separated evaporators into a single evaporator and the object of the SUDS evaporator is to recover energy from dual heat sources, i.e. air and water. Simulation program is developed for the dual source heat pump system with a SUDS evaporator and experimental data are obtained and compared with the simulation results. Differences in heating capacity and COP are 7% and 8% respectively. Simulation results are in good agreement with the test results. Therefore, the developed program is effectively used for the design and performance prediction of the dual source heat pump system with a SUDS evaporator.

  • PDF