• Title/Summary/Keyword: pump power

Search Result 1,421, Processing Time 0.021 seconds

Experimental study on vibration projection of seawater circulation pumps in nuclear power plant

  • Lin Bin;Huang Qian;Zhang Rongyong;Zhu Rongsheng;Fu Qiang;Wang Xiuli
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2576-2583
    • /
    • 2024
  • In this paper, the similarity criterion and dimensionless conversion method combined with the elasticity condition and Hooke's law are used to derive the functional relationship of the maximum effective value of the vibration velocity between the prototype pump and the model pump. The seawater circulation pump of a nuclear power plant is used as the prototype pump, and the model pump is obtained by performance conversion and choosing the appropriate scale, and the vibration state of the model pump under different flow rates is measured and analyzed. The vibration data of the model pump through the function relationship to find out the vibration parameters of the prototype model pump, and compare with the vibration data of the seawater circulation pump in reality. It can be seen that with the increase of flow rate, the maximum effective value of the vibration velocity of both model and prototype decreases and then increases, and the relative error is small, the maximum value is 7.7757%. Therefore, it can be considered that the functional relationship of model pump converted to prototype pump derived in this paper can be used to analyze the vibration of the actual seawater circulation pump of coastal nuclear power plant.

An Experimental Study on Pulsation Noise Reduction of Power Steering Oil Pump (Power Steering Oil Pump의 맥동소음 저감에 관한 실험적 연구)

  • 안세진;김명환;박진형;정의봉;유승근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.395-400
    • /
    • 2003
  • Power steering oil pump is generally used to support the power to steering system of most kinds of vehicle. The noise caused by power steering ell pump make passenger to be uncomfortable, because its frequency is higher than that is produced by engine. In this paper, the field test of real car was carried out to analyze the phenomenon of the pump noise, and the lab test was also performed to survey the dynamic characteristics of pump assembly. The results of the series of tests show that frequency range of 600-800㎐ should be dealt with to reduce the pump noise. After four cases of design changes were carried out to actually reduce the noise and tested in condition of partial assembly. Some improvement can be gotten from a certain design change.

  • PDF

Determination of Sizes of the Pump Rooms in Korean Nuclear Power Plants (한국형 원자력발전소 펌프실 면적 산정 방안)

  • Lee, Hyo-Sung;Koh, Churl-Kyun;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.9 no.2
    • /
    • pp.36-41
    • /
    • 2013
  • For areas installed with one pump, the trend for expected sizes of pump room areas is observed once pump power and floor dimensions are provided. However, these pump rooms with auxiliary charging pumps, turbine driven auxiliary feedwater pumps, and pump rooms with a separate valve room have unique ways to determine the pump room area. No definite trends are identified for areas installed with two pumps using pump power and floor dimensions. The relationship between pump power and floor dimensions is also unable to be found.

  • PDF

Dynamic Simulation of Pump-Storage Power Plants with different variable speed configurations using the Simsen Tool

  • Kruger, Klaus;Koutnik, Jiri
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.334-345
    • /
    • 2009
  • Pumped storage power plants are playing a significant role in the contribution to the stabilization of an electrical grid, above all by stable operation and fast reaction to sudden load respectively frequency changes. Optimized efficiency and smooth running characteristics both in pump and turbine operation, improved stability for synchronization in turbine mode, load control in pump mode operation and also short reaction times may be achieved using adjustable speed power units. Such variable speed power plants are applicable for high variations of head (e.g. important for low head pump-turbine projects). Due to the rapid development of power semiconductors and frequency converter technology, feasible solutions can be provided even for large hydro power units. Suitable control strategies as well as clear design criteria contribute significantly to the optimal usage of the pump turbine and motor-generators. The SIMSEN tool for dynamic simulations has been used for comparative investigations of different configurations regarding the power converter topology, types of semiconductors and types of motor-generators including the coupling to the hydraulic system. A brief overview of the advantages & disadvantages of the different solutions can also be found in this paper. Using this approach, a customized solution minimizing cost and exploiting the maximum usage of the pump-turbine unit can be developed in the planning stage of new and modernization pump storage projects.

Performance Analysis on Early Detection of Fault Symptom of a Pump with Abnormal Signals (오신호 입력에 따른 펌프의 고장징후 조기감지 성능분석)

  • Jung, Jae-Young;Lee, Byoung-Oh;Kim, Hyoung-Kyun;Kim, Dae-Woong
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.66-72
    • /
    • 2016
  • As a method to improve the equipment reliability, early warning researches that can be detected fault symptom of an equipment at an early stage are being performed out among developed countries. In this paper, when abnormal signal is input to actual normal signal of a pump, early detection studies on pump's fault symptom were carried out with auto-associative kernel regression as an advanced pattern recognition algorithm. From analysis, correlations among power of motor driving pump, discharge flow of pump, power output of pump, and discharge pressure of pump are exited. When the abnormal signal is input to one of those normal signals, the other expected values are changed due to the influence of the abnormal signal. Therefore, the fault symptom of pump through the early-warning index is able to detect at an early stage.

Impact test of a centrifugal pump used in nuclear power plant under aircraft crash scenario

  • Huang, Tao;Chen, Mengmeng;Li, Zhongcheng;Dong, Zhanfa;Zhang, Tiejian;Zhou, Zhiguang
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1858-1868
    • /
    • 2021
  • Resisting an accidental impact of large commercial aircrafts is an important aspect of advanced nuclear power plant (NPP) design. Especially after the 9·11 event, some regulations were enacted, which required the design of NPPs should consider the accidental impact of large commercial aircrafts. Normal working of equipment is important for stopping reactor under an impact when an NPP is in operation. However, there is a lack of reliable analysis and research on the impact test of nuclear prototype equipment. Therefore, in order to study the response of the equipment under high acceleration impact, a centrifugal pump is selected as the research object to perform the impact test. A horizontal half-sinusoidal pulse wave was applied to the working pump. The test results show that the horizontal response of the motor and flange is greater compared to other parts, as well as the vertical response of the coupling. The stress response of the pump body support and motor support is high, hence these parts should be considered in the design of the pump. Finally, combined with the damage and stress evaluation results of the pump under different amplitudes, the ultimate impact acceleration that the pump can withstand is given.

Comparative Characteristic Analysis of a Hydraulic Control System Using a Speed Controlled Hydraulic Pump (유압펌프 회전속도 제어방식 유압제어시스템의 특성 비교 분석)

  • Jeong, H.S.;Jeong, S.W.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.3
    • /
    • pp.13-19
    • /
    • 2010
  • Hydraulic systems are widely used as a power transfer and/or power control system due to its flexibility, controllability, accuracy and high power density. Valve controlled and/or pump capacity controlled systems are normally adopted as a control device, but nowadays pump speed controlled systems are emerging as a new energy-efficient hydraulic control system. In this paper the pump speed controlled system for the cylinder position control of a counter balance circuit is investigated by simulation study and position control experiments were carried out. As a result, the possibility and efficiency of the pump speed controlled system were verified.

  • PDF

Design of Fuzzy-Power Controller for a Pump with Electric Proportional Valve (절자 비례 밸브를 갖는 펌프의 퍼지-동력제어기 설계)

  • 전순용
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.4
    • /
    • pp.441-447
    • /
    • 1998
  • Motivated by a recent work, a fuzzy-power-controller(FPC) is designed for the relieving-horsepower control of output variable pump with electrical proportional valve and actually implemented on the industrial excavator. In order to calculate the output power of pump with input of FPC, a linear discrete time model of load system to pump is obtained and the result is applied to control the engine-pump coupled system by software without pressure and flow sensor. The FPC controls the engine and pump coupled system by relieving horsepower control according to the change of load and the running conditions in relieving horsepower control are selected by fuzzy inference engine. A case study is peformed through the construction of the control device and installation on the excavator. It shows that the relieving-horsepower control system with the FPC, as suggested in this paper, is superior to the conventional PID controllers. And also, the excavator, with the FPC, shows that the power-loss of the coupled system is reduced and the running speed of the hydraulic actuator is enhanced.

  • PDF

Failure Analysis of Circulating Water Pump Shaft in Power Plant (발전 계획에서 순환 물 펌프 고장 분석)

  • Lee, Jaehong;Jung, Nam-gun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.125-128
    • /
    • 2021
  • This paper presents the root cause failure analysis of the circulating water pump in the 560 MW thermal power plant. A fractured austenitic stainless-steel shaft operated for 24 years was examined. Fracture morphology was investigated by micro and macro-fractographic analysis. The metallurgical analyses including chemical analysis, metallography and hardness testing were performed. The analysis reveals that the pump shaft was fractured due to the reverse bending load with combination of rotating bending load. Corrective actions for plant operator was recommended based on the analysis.

Effects of the Impeller Shapes on the Non-Clogging and the Screw-type Centrifugal Pump Performances (논클로그 및 스크류식 원심펌프의 임펠러 형상이 펌프성능에 미치는 영향)

  • Kim, Dong-Joo;Suh, Sang-Ho;Sung, Sun-Kyung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.1 no.1 s.1
    • /
    • pp.81-89
    • /
    • 1998
  • In this study, the effects of the impeller shapes on the pump performances of the non-clogging and the screw-type centrifugal pumps are experimentally studied. The characteristics of total head, efficiency and power of the non-clogging pump increase as the number of vanes increases. The screw-type centrifugal pump with the linear-shape vane shows a little better performance than that of the screw-type centrifugal pump with the curved-shape vane. The differences in the characteristics of total head, efficiency and power are, however, insignificant. Therefore, it is advisable that, considering the convenience of pump manufacturing, the screw-type centrifugal pump with the linear-shape vane should be used. This study also compares the pump characteristics of the non-clogging pump and screw-type centrifugal pump. The characteristics of total head and efficiency of the non-clogging pump are better than those of the screw-type centrifugal pump. The screw-type centrifugal pump requires more shaft power than the non-clogging pump.

  • PDF