• Title/Summary/Keyword: pump energy

Search Result 1,443, Processing Time 0.024 seconds

Development of Water Hammer Simulation Model for Safety Assessment of Hydroelectric Power Plant (수력발전설비의 안전도 평가를 위한 수충격 해석 모형 개발)

  • Nam, Myeong Jun;Lee, Jae-Young;Jung, Woo-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.760-767
    • /
    • 2020
  • Sustainable growth of hydroelectric power plants is expected in consideration of climate change and energy security. However, hydroelectric power plants always have a risk of water hammer damage, and safety assurance is very important. The water hammer phenomenon commonly occurs during operations such as rapid opening and closing of the valves and pump/turbine shutdown in pipe systems, which is more common in cases of emergency shutdown. In this study, a computational numerical model was developed using the MOC-FDM scheme to reflect the mechanism of water hammer occurrence. The proposed model was implemented in boundary conditions such as reservoir, pipeline, valve, and pump/turbine conditions and then applied to simulate hypothetical case studies. The analysis results of the model were verified using the analysis results at the main points of the pipe systems. The model produced reasonably good performance and was validated by comparison with the results of the SIMSEN package model. The model could be used as an efficient tool for the safety assessment of hydroelectric power plants based on accurate prediction of transient behavior in the operation of hydropower facilities.

$CO_2$ Removal Process Case Studies and Plant Performance Analysis for 300MW IGCC Power Plant (300MW 급 IGCC Power Plant $CO_2$ 제거공정의 Case Studies 및 Plant 성능 영향 분석)

  • Jeon, Jinhee;Yoo, Jeongseok;Paek, Minsu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.71.2-71.2
    • /
    • 2011
  • 300MW 급 태안 IGCC 가스화 플랜트 및 기존 발전소에 CCS 를 설치할 경우에 대해 기술 타당성 검증을 목적으로 CCS 모델링을 수행하였다. CCS Case Studies 는 플랜트 운전부하에 따른 $CO_2$ 제거율, $H_2S$ 제거율, 소모동력 범위 등 플랜트 성능을 예측할 수 있다. Case Studies 결과를 활용하여 설계된 CCS 설비 용량이 운전범위에 적합한지를 판단할 수 있고 과잉 설계되었을 경우 플랜트 건설비를 절감할 수 있다. IGCC 가스화 플랜트에서 생산되는 합성가스의 $CO_2$ 분압, 목표 $CO_2$ 제거율, 경제성을 기준으로 적합한 CCS 공정을 판단한 결과 Selexol 공정이 선정되었다. Selexol 공정은 고압, 고농도의 산성가스 제거에 적합하며 다른 물리적 용매인 Rectisol 공정에 비해 건설비용이 경제적이고 화학 흡수제인 아민과 비교하여 운전 온도 범위가 넓다. CO, $H_2O$$CO_2$, $H_2$ 로 전환하는 Water Gas Shift Reaction (WGSR) 공정은 Co/Mo 촉매 반응기로 구성되었고 Selexol 공정은 $H_2S$ Absorber, $H_2S$ Stripper, $CO_2$ Absorber, $CO_2$ Flash Drum 로 구성되었다. WGSR+Selexol 모델링은 Wet Scrubber 후단의 합성가스 (40.5 bar, $136{\sim}139^{\circ}C$) 를 대상으로 하였다. WGSR+Selexol 공정 운전 조건 변화 [Process Design Case(PDC), Equipment Design Case(EDC), Turndown Design Case(TDC)] 에 따른 플랜트 모델링 결과를 비교분석 하였다. 주요 분석 내용은 WGSR 설비에서의 CO 의 $CO_2$ 전환 효율, Selexol 설비에서 $CO_2$ 제거 효율, $H_2S$ 제거 효율이다. 모델링 결과 WGSR 설비에서의 CO 의 $CO_2$ 로의 전환율 99.1% 이상, Selexol 설비에서 $CO_2$ 제거율은 91.6% 이상, $H_2S$ 제거율 100%이었다. CCS 설비 설치에 따른 플랜트 성능 영향을 분석하기 위해서 CCS 설비의 Chiller, Compressor, Pump 소비동력을 계산하였다. 모델링 결과 Chiller 는 2.6~8.5 MWth, Compressor 는 3.0~9.6 MWe, Pump 는 1.4~3.0 MWe 범위 이었다. 플랜트 로드가 50%인 TDC 소모동력은 플랜트 로드가 100%인 PDC 소모동력의 절반 수준이었다. 합성가스를 WGS+Selexol 공정을 통해 수소가스로 전환시키면 가스터빈 연료가스의 Lower Heating Value (LHV) 값이 평균 11.5% 감소하였다.

  • PDF

Evaluation on Heating Effects of Geothermal Heat Pump System in Farrowing House (지열 난방시스템을 이용한 분만돈사의 난방효과 분석)

  • Choi, H.C.;Park, Jae-Hong;Song, J.I.;Na, J.C.;Kim, M.J.;Bang, H.T.;Kang, H.G.;Park, S.B.;Chae, H.S.;Suh, O.S.;Yoo, Y.S.;Kim, T.W.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.205-215
    • /
    • 2010
  • Geothermal heat pump system (GHPS) is an energy-efficient technology that use the relatively constant and renewable energy stored in the earth to provide heating and cooling. With the aim of using GHPS as a heating source, it's possibilities of application in farrowing house were examined by measuring environmental assessment and sow's performance. A total of 96 sows were assigned to 2 pig housings (GHPS and conventional housing) with 48 for four weeks in winter season. During the experimental period, indoor maximum temperature in GHPS-housing was measured up to $26.7^{\circ}C$, average temperature could maintain $21.2^{\circ}C$. The mean value of dust levels and $CO_2$, $NH_3$ and $H_2S$ gas emissions were decreased in GHPS-housing compare with those of conventional housing. Litter size, birth weight, parity and weaning weight did not differ between housings. However, feed intake of sow in GHPS-housing was lower than that of conventional housing. In energy consumption for heating, electric power consumption increased in GHPS-housing than the conventional housing, a 2,250 kwh increase, whereas there is no fuel usage for heater in GHPS-housing. Amount of ground water circulated for heating in cold weather for earth heat exchanger was 8.4-12.9 ton per day. In conclusion, GHPS may have environmental benefits and effectiveness of heating in farrowing housing and affect the performance in sows.

The Treatment of Source Separated Food Waste by Mesophilic Anaerobic Digestion System with Leachate Recirculation (중온 침출수 재순환 혐기성 소화 시스템을 이용한 음식물류 폐기물 처리)

  • Cho, Chan-Hui;Lee, Byonghi;Lee, Yong-Woon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.1
    • /
    • pp.31-40
    • /
    • 2016
  • In this study, mesophilic anaerobic digestion of source separated food waste was carried out by leachate recirculation system and methane gas was produced. Two systems - system A and B were fabricated and placed within water bath to maintain $36^{\circ}C$. Each system was comprised of an anaerobic bioreactor and a leachate tank. Leachate in bioreactor was separated through the screen located at 30 mm above the bottom and a pump was installed to transfer collected leachate to the leachate tank. Everyday, 2.5 L of the leachate was pumped from the bioreactor to the leachate tank for 30 min and transferred leachate was pumped back to the top of the bioreactor for 30min, sequentially. Source separated food waste used for this experiment was washed by water before transferring to the laboratory. Transferred food waste was warmed to $36^{\circ}C$ before being fed to bioreactors. System A was fed to 49.1 g VS (Volatile Solids) and System B was fed to 54.0 g VS at every two weeks, respectively. $NH_4{^+}-N$ and salinity were monitored to see the inhibition toward anaerobic bioreaction and it was found that concentrations of these materials were not high enough to affect the bioreaction. Although the food waste was fed biweekly for 112 days and 140 days at system A and B, respectively, there was no sludge withdrawal from each system. Average methane productions rates were 0.439 L $CH_4/g$ VS and 0.368 L $CH_4/g$ VS for system A and B, respectively.

Design Guidlines of Geothermal Heat Pump System Using Standing Column Well (수주지열정(SCW)을 이용한 천부지열 냉난방시스템 설계지침)

  • Hahn, Jeong-Sang;Han, Hyuk-Sang;Hahn, Chan;Kim, Hyong-Soo;Jeon, Jae-Soo
    • Economic and Environmental Geology
    • /
    • v.39 no.5 s.180
    • /
    • pp.607-613
    • /
    • 2006
  • For the reasonable use of low grade-shallow geothermal energy by Standing Column Well(SCW) system, the basic requirements are depth-wise increase of earth temperature like $2^{\circ}C$ per every 100m depth, sufficient amount of groundwater production being about 10 to 30% of the design flow rate of GSHP with good water quality and moderate temperature, and non-collapsing of borehole wall during reinjection of circulating water into the SCW. A closed loop type-vertical ground heat exchanger(GHEX) with $100{\sim}150m$ deep can supply geothermal energy of 2 to 3 RT but a SCW with $400{\sim}500m$ deep can provide $30{\sim}40RT$ being equivalent to 10 to 15 numbers of GHEX as well requires smaller space. Being considered as an alternative of vertical GHEX, many numbers of SCW have been widely constructed in whole country without any account for site specific hydrogeologic and geothermal characteristics. When those are designed and constructed under the base of insufficient knowledges of hydrgeothermal properties of the relevant specific site as our current situations, a bad reputation will be created and it will hamper a rational utilization of geothermal energy using SCW in the near future. This paper is prepared for providing a guideline of SCW design comportable to our hydrogeothermal system.

Calculation of non-condensable gases released in a seawater evaporating process (해수 증발과정에서의 기체방출량 계산)

  • Jeong, Kwang-Woon;Chung, Hanshik;Jeong, Hyomin;Choi, Soon-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.182-190
    • /
    • 2017
  • All liquids contain a small amount of gaseous components and the amount of gases dissolved in a liquid is in accordance with Henry's Law. In a multi-stage thermal-type seawater desalination plant, as the supplied seawater undergoes variations in temperature and pressure in each evaporator, the gases dissolved in the seawater are discharged from the liquid. The discharged gases are carbon dioxide, nitrogen, oxygen, and argon, and these emitted gases are non-condensable. From the viewpoint of convective heat transfer, the evaluation of non-condensable gas released during a vacuum evaporation process is a very important design factor because the non-condensable gases degrade the performance of the cooler. Furthermore, in a thermal-type seawater desalination plant, most evaporators operate under vacuum, which maintained through vacuum system such as a steam ejector or a vacuum pump. Therefore, for the proper design of a vacuum system, estimating the non-condensable gases released from seawater is highly crucial. In the study, non-condensable gases released in a thermal-type seawater desalination plant were calculated quantitatively. The calculation results showed that the NCG releasing rate decreased as the stage comes getting a downstream and it was proportional to the freshwater production rate.

Thermoeconomic Analysis of Hybrid Desiccant Cooling System Driven by District Heating (지역난방에 연계된 하이브리드 제습냉방시스템의 경제성 분석)

  • Ahn, Joon;Kim, Jaeyool;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.721-729
    • /
    • 2014
  • A hybrid desiccant cooling system (HDCS) that uses a heat pump driven by district heating instead of a sensible rotor can provide an increased energy efficiency in summer. In this paper, the summer operation costs and initial costs of both the HDCS and traditional systems are analyzed using annual equal payments, and national benefits are found from using the HDCS instead of traditional systems. In the analysis results, the HDCS reduces the operation cost by 30 compared to the traditional systems, and each HDCS unit has 0.079 TOE per year of primary energy savings and 0.835 $TCO_2$ per year of $CO_2$ emission reduction more than the traditional systems. If HDCSs were to be installed in 680,000 households by 2020, this would produce a replacement power effect of 463 MW. Despite this savings effect, HDCSs require a government subsidy before they can be supplied because the initial cost is higher than that of traditional systems. Thus, this paper calculates suitable subsidies and suggests a supply method for HDCSs considering the national benefits.

Design and Construction of a Bottoming Organic Rankine Cycle System for an Natural Gas Engine (가스엔진용 유기랭킨사이클의 설계 및 제작)

  • Lee, Minseog;Baek, Seungdong;Sung, Taehong;Kim, Hyun Dong;Chae, Jung Min;Cho, Young Ah;Kim, Hyoungtae;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.65-72
    • /
    • 2016
  • ORC system was designed and constructed for utilizing the heat of the exhaust gas and coolant released from the gas engine which was modified to use natural gas as a fuel. In this paper the components of the ORC system were designed and manufactured based on measured data of the gas engine. The components are composed of two plate heat exchanger, the 5kW-class expander and multi stage centrifugal pump. The thermodynamic performance of the ORC system was analyzed by using the electric heater. Also, the developed ORC system was implemented to modified natural gas engine. Two gas engines were used to supply heat to the ORC system. As a result of test bench, when the heat source temperature is $110^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 5.22kW, 7.41, 9.09%. As a result of field test, when the heat source temperature is $86^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 2kW, 3.75, 6.45%.

The Study on Automatic Temperature Transmission System for the Heating pipe at Home (가정식난방배수관내의자동온도송신장치에대한연구)

  • Park, Chul-Min;Jo, Heung-Kuk;Lee, Hoon-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2641-2646
    • /
    • 2009
  • The more growing on home automation system at automatic control, the more efficiency required for energy consumption and for recycling energy in near future. Heating is essential in general apartment. Heating method is two types in apartment. One uses electricity, and other one uses warm water. If use electricity, is not efficient by rise of electric charges. But, It can reduce much in expense aspect, if use warm water. When use warm water, temperature of warm water is not equal from all pipe parts. Therefore, indoor tempera can be unequal with set point. Solution of these problems is as following. Temperature sensor in warm water attach pipe. The measured temperature transmits by real time. Temperature of warm water controls in receiver side. In this paper, we propose an automatic temperature transmission system for the heating pipe at home, that is a low-power based, and supply the energy source from a small AC motor resided in bottom cement mortal. The proposed system is used in power mechanism from a collision process of water-jet using propeller water-difference and also designed a CPU module by Atmega8 at ATMEL co., Inc. and a communication module by CC1020 at Chipcon co., Inc.

Research Background and Plan of Enhanced Geothermal System Project for MW Power Generation in Korea (MW급 EGS 지열발전 상용화 기술개발사업의 추진 배경 및 계획)

  • Yoon, Woon-Sang;Song, Yoon-Ho;Lee, Tae-Jong;Kim, Kwang-Yeom;Min, Ki-Bok;Cho, Yong-Hee;Jeon, Jong-Ug
    • Tunnel and Underground Space
    • /
    • v.21 no.1
    • /
    • pp.11-19
    • /
    • 2011
  • Geothermal energy is believed to be an important source among the renewable energy sources to provide the base load electricity. Although there has been a drastic increase in the use of geothermal heat pump in Korea, there is no geothermal power plant in operation in Korea. Fortunately, the first EGS (Enhanced Geothermal System) Project in Korea has started in Dec 2010. This five year project is divided into two stages; two years for exploration and drilling of 3 km depth to confirm the minimum target temperature of 100 degrees, and another three years composed drilling 5 km doublet, hydraulic stimulation of geothermal reservoir with expected temperature of 180 degrees (40 kg/s) and construction of MW geothermal power plant in the surface. This EGS project would be a landmark effort that invited a consortium of industry, research institutes and university with expertises in the fields of geology, hydrogeology, geophysics, geomechanics and plant engineering.