• Title/Summary/Keyword: pump

Search Result 6,373, Processing Time 0.034 seconds

Hydraulic Design Optimization and Performance Analysis of a Centrifugal Blood Pump (원심형 혈액펌프의 최적화 수력설계 및 성능해석)

  • Park Moo Ryong;Yoo Seong Yeon;Oh Hyoung Woo;Yoon Eui Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.1 s.244
    • /
    • pp.87-94
    • /
    • 2006
  • This paper presents the hydrodynamic design and performance analysis method for a miniaturized centrifugal blood pump using three-dimensional computational fluid dynamics (CFD) code. In order to obtain the hydraulically high efficient configuration of a miniaturized centrifugal blood pump for cardiopulmonary circulation, a well-established commercial CFD code was incorporated considering detailed flow dynamic phenomena in the blood pump system. A prototype of centrifugal blood pump developed by the present design and analysis method has been tested in the mock circulatory system. Predicted results by the CFD code agree very well with in vitro hydraulic performance data for a centrifugal blood pump over the entire operating conditions. Preliminary in vivo animal testing has also been conducted to demonstrate the hemodynamic feasibility for use of centrifugal blood pump as a mechanical circulatory support. A miniaturized centrifugal blood pump developed by the hydraulic design optimization and performance prediction method presented herein shows the possibility of a good candidate for intra and extracorporeal cardiopulmonary circulation pump in the near future.

Testing and Modification of an Axial Flow Irrigation Pump manufactured in Vietnam

  • V.M.Salokhe;Khanh, Vu-Tuan
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.247-256
    • /
    • 1996
  • The performance of a commonly used, inclined shaft, axial flow pump manufactured in Vietnam was evaluated . The pump tested had a 37 cm diameter thrust impeller and 40 cm outlet diameter. This pump was initially evaluated to establish the base performance curves for three total static heads of 1.45 m, 1.75m and 2.15 m at a constant recommended speed of 980 rpm. In the field survey, brass sleeve , impeller and lubricating system. These parts of the pump were modified and then it was tested again at the same test conditions used for the original one. Maximum efficiency of the original pump varied from 56.11% to 53.15% , and that of the modified pump from 57.63% to 54.52% when the total static head varied from 1.45 m to 2.15m . At these total static heads, the discharge, the total head and the power input varied from 387 to 347l/s, 4.25 to 4.60m and 28.72 to 29.38kW, respectively, for the original pump and from 388 to 346l/s , 4.29 to 4.63 m and 28.23 to 28.91 kw, respectivel , for the modified pump. The efficiency of the pump after modification increased by more than 1.5% and the power input decreased by 1.7%.

  • PDF

Heating Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 난방성능)

  • Park, Geun-Woo;Lee, Eung-Youl
    • New & Renewable Energy
    • /
    • v.3 no.2 s.10
    • /
    • pp.40-46
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}...$ annually and the quality of that water is as good as well water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000\;ton/day$. The heat pump capacity is 5RT. The heat pump heating COP was $3.85{\sim}4.68$ for the open type and $3.82{\sim}4.69$ for the close type system. The system heating COP including pump power is $3.0{\sim}3.32$ for the open type and $3.32{\sim}3.84$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

The Study on the Structure and Performance of Heat Pump Calorimeter (열펌프 열량계 구조 및 성능 특성 연구)

  • Park, Seung Byung;Lee, Sang-Hyeok;Choi, Jinnil;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.4
    • /
    • pp.7-13
    • /
    • 2015
  • The efficiency, reliability and performance of any heat pump unit can only be ascertained after it has been tested and rated. For this reason, specific facilities, equiped with testing plants are built. Heat pump calorimeter is the facilities used by most of these testing facilities in their rating and certification process. The ultimate function of calorimeters is to, control and maintain the constant standard test conditions (indoor/outdoor entering temperatures and flow rate etc) during testing period. In this study, the test standards of heat pump unit and the structure of the calorimeter are surveyed. In addition, this study analyzes the total energy consumption of a water to water heat pump calorimeter. Heat pump calorimeter consumed much energy to excute the heat pump tests. The energy consumption of the calorimeter was higher than the heat pump unit, and it was increased as the heat pump unit capacity decreased.

Design of a Valveless Type Piezoelectric Pump for Micro-Fluid Devices

  • Kim, Hyun-Hoo;Oh, Jin-Heon;Yoon, Jae-Hun;Jeong, Eui-Hwan;Lim, Kee-Joe
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.2
    • /
    • pp.65-68
    • /
    • 2010
  • The operation principle of a traveling wave rotary type ultrasonic motor can be successfully applied to the fluidic transfer mechanism of the micro-pump. This paper proposes an innovative valveless micro-pump type that uses an extensional vibration mode of a traveling wave as a volume transportation means. The proposed pump consists of coaxial cylindrical shells that join the piezoelectric ceramic ring and metal body, respectively. In order to confirm the actuation mechanism of the proposed pump model, a numerical simulation analysis was implemented. In accordance with the variations in the exciting wave mode and pump body dimension, we analyzed the vibration displacement characteristics of the proposed model, determined the optimal design condition, fabricated the prototype pump from the analysis results and evaluated its performance. The maximum flow rate was approximately $595\;{\mu}L/min$ and the highest back pressure was 0.88 kPa at an input voltage of $130\;V_{rms}$. We confirmed that the peristaltic motion of the piezoelectric actuator was effectively applied to the fluid transfer mechanism of the valveless type micro pump throughout this research.

Simulation Analysis on Performance Comparison between R744 and R22 Solar Hybrid Heat Pump (R744와 R22를 적용한 태양열 하이브리드 열펌프의 성능 시뮬레이션 비교 분석)

  • Kang, Byun;Cho, Honghyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.1-10
    • /
    • 2013
  • Simulation study of a solar hybrid heat pump using R744 and R22 for residential applications was carried out according to heat pump operating temperature, outdoor temperature and solar radiation. As a result, when the heat pump operating temperature increases from $40^{\circ}C$ to $48^{\circ}C$, the COP of a R744 and R22 heat pump system decrease from 2.15 to 1.7 and from 3.09 to 2.69, respectively. Besides, as the outdoor temperature rises from $3^{\circ}C$ to $11^{\circ}C$, the COP of R744 and R22 heat pump system increase from 1.73 to 2.12 and from 2.73 to 3.02. When the solar radiation increases from 10 to 20 $MJ/m^2$, the collector operating time and collector efficiency of R744 heat pump increase 10.3 times and 50.7%, respectively. The performance of R744 solar hybird heat pump is more sensitive to operation condition compared to that of R22. Besides, the solar heating system is more effective to the R744 heat pump system.

Development of the Driving Pump for the Low Noise Large Cavitation Tunnel (저소음 대형 캐비테이션 터널 구동 펌프 개발)

  • Ahn, Jong-Woo;Kim, Gun-Do;Kim, Ki-Sup;Lee, Jin-Tae;Seol, Han-Shin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.4
    • /
    • pp.370-378
    • /
    • 2008
  • It is reported to develop the driving pump for the Low Noise Large Cavitation Tunnel(LOCAT) which is under construction at Maritime & Ocean Engineering Research Institute(MOERI). For low background noise condition of the LOCAT, it is crucial not only the best pump efficiency but also no cavity occurrence at any operating conditions. Design condition of the pump is determined by considering the required pump headrise, flow quantity, shaft rotation velocity and pump diameter. Performance analysis of the pump is conducted using commercial CFD codes ($BladeGen^+$, CFX-10), and the predicted results are verified by a series of model tests. Cavity was not observed at any operating condition in the model test, which were conducted at the midium cavitation tunnel of MOERI. The optimum pump for LOCAT, named as LP-11, was successfully developed through a series of pump design processes composed of blade design, performance analysis and model test.

Performance analysis of dual source heat pump system with single unit dual source evaporator (SUDS증발기를 사용한 2중열원 열펌프의 성능해석)

  • 우정선;이세균;이재효;박효순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.391-400
    • /
    • 1999
  • The efficiency and capacity of an air source heat pump system decrease as the ambient temperature drops. One strategy of avoiding the decrease of the efficiency and capacity in air source heat pump system is to switch to another thermal energy source. Water can be a good candidate for the heat source. This paper presents the results of the performance analysis of heat pump system with a single unit dual source(SUDS) evaporator The heat exchanger combines two separated evaporators into a single evaporator and the object of the SUDS evaporator is to recover energy from dual heat sources, i.e. air and water. Simulation program is developed for the dual source heat pump system with a SUDS evaporator and experimental data are obtained and compared with the simulation results. Differences in heating capacity and COP are 7% and 8% respectively. Simulation results are in good agreement with the test results. Therefore, the developed program is effectively used for the design and performance prediction of the dual source heat pump system with a SUDS evaporator.

  • PDF

Influence of Circualr Casing on the Performance of Very Low Specific Speed Centrifugal Pump (원형케이싱이 극저비속도 원심펌프의 성능에 미치는 영향)

  • Choi, Young-Do;Kagawa, Shusaku;Kurokawa, Junichi
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.1 s.34
    • /
    • pp.32-39
    • /
    • 2006
  • Recently, according to the trend of small size in scale and high speed in rotation of turbomachinery, very low specific speed centrifugal pump is taking a growing interest because the pump is characterized by high head and low flow rate with convenience of manufacturing and maintenance compared with conventional positive displacement pump. However, the efficiency of the very low specific speed centrifugal pump drops rapidly with the decrease of specific speed. The purpose of this study is nor only to examine the influence of casing type on the performance of centrifugal pump in the range of very low specific speed but also to determine the proper casing type for the improvement of pump performance. The results show that circular casing is suitable for the centrifugal pump in the range of very low specific speed and the influence of impeller configuration on the pump performance is very small. Radial thrust in the circular and volute casings is considerably small in the range of very low specific speed.

Influence of Large Change of Specific Speed on the Performance of Very Low Specific Speed Centrifugal Pump (비속도의 큰 변화가 극저비속도 원심펌프의 성능에 미치는 영향)

  • Choi, Young-Do;Kagawa, Shusaku;Kurokawa, Junichi
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.1 s.34
    • /
    • pp.40-46
    • /
    • 2006
  • Efficiency of a centrifugal pump is known to drop rapidly with a decrease of specific speed $n_s$. However, below $n_s=60\;[min^{-1},\;m^3/min,\;m]$, the pump characteristics are not yet clear. Therefore, present study is aimed to investigate the influence of large change of specific speed on the performance of a very low specific speed centrifugal pump. Moreover, influence of impeller configuration on the performance of very low specific speed pump is investigated. The results show that very low specific speed can be accomplished by reducing volute throat sectional area using circular spacer. Influence of the spacer's location and configuration in the discharge passage on the pump performance is very small. Best efficiency of very low specific speed centrifugal pump decreases proportionally to the specific speed but the best efficiency decreases on a large scale in the range of $n_s<40$. Influence of impeller configuration on the pump performance and radial thrust of centrifugal pump are considerably small in the range of extremely low specific speed $(n_s=25)$.