• Title/Summary/Keyword: pulse waveforms

검색결과 165건 처리시간 0.024초

System Design and Performance Analysis of a Variable Frequency LED Light System for Plant Factory

  • Han, Jae Woong;Kang, Tae Hwan;Lee, Seong Ki;Han, Chung Su;Kim, Woong
    • Journal of Biosystems Engineering
    • /
    • 제39권2호
    • /
    • pp.87-95
    • /
    • 2014
  • Purpose: The purpose of this study was to design a variable frequency LED light system for plant factory which combined red, blue, green, white, and UV lights and controlled the ratio of the light wavelength. In addition, this study evaluated the performance of each combination of LED to verify the applicability. Methods: Four combinations of LED (i.e. Red+Blue, Red+Blue+Green, Red+Blue+White, Red+Blue+UV) were designed using five types of LED. The system was designed to control the duty ratio of each wavelength of LED by 1% interval from 0~100%, the pulse by 1Hz interval from 1~20kHz. Response characteristics of the control system, spectral distribution of each combination, light uniformity and uniformity ratio were measured to test the performance of the system. Results: Clean waveforms were measured from 10Hz to 10kHz regardless of duty ratio. Frequency distortion was observed within 5% of inflection point at frequencies above 10kHz regardless of duty ratio, but it was judged negligible. Spectra showed a normal distribution, and maximum PPF with duty ratio of 100% was $271.4{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ for the Red+Blue combination. PPF of the Red+Blue+Green combination was $258.9{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and that of the Red+Blue+White combination was $273.9{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. PPF of the Red+Blue+UV combination was $267.7{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Uniformity ratio for the area excepting border showed 0.90 for the Red+Blue and Red+Blue+White combinations, 0.87 for the Red+Blue+Green combination, and 0.88 for the Red+Blue+UV combination. The light was irradiated evenly at the area excepting border, so it was suitable for plant growing. Conclusions: From the results of this study, response characteristics of the control system, spectral distribution of each combination, light uniformity and uniformity ratio were suitable for applying into the plant factory.

동맥압 형태를 고려한 오실로메트릭 모델분석 (Analysis of Oscillometric Model based on Shape of Arterial Pressure)

  • 임성수;이경중
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권4호
    • /
    • pp.411-417
    • /
    • 2000
  • 본 연구에서는 시뮬레이션을 이용하여 동맥압 파형 형태에 대한 오실로메트릭 방법을 분석하고 수축기압과 이완기압을 검출할 수 있는 새로운 알고리즘을 제시하였다. 동맥압 파형 형태에 대한 오실로메트릭 방법을 분석하고 수축기압과 이완기압을 검출할 수 있는 새로운 알고리즘을 제시하였다. 동맥압 파형 형태에 대한 오실로메트릭 방법을 분석하기 위해 동맥압 파형 형태를 쉽게 가변할 수 있는 동맥압 모델을 만들었으며, 기존의 정적인 동맥 압력-용적 지수함수 모델을 이용하여 오실로메트릭 모델의 구현 및 컴퓨터 시뮬레이션을 수행하였다. 동맥압 파형 형태와 보편화된 혈압 검출 기준인 특성비율과의 상관관계 분석을 통하여 동맥압 파형 형태와 맥압의 영향 때문에 특성비율이 수축기압과 이완기압을 결정하는 유일한 기준이 될 수 없음을 밝혔으며, 동맥압 파형 형태와 오실레이션 파형 형태의 상관관계 분석을 통하여 오실레이션 파형으로부터 동맥압 파형 형태를 추정할 수 있는 방법을 제시하였다. 최대 크기 오실레이션 파형과 동맥압 파형의 관계로부터 맥압을 구할 수 있는 맥압 표를 구성하여 수축기압과 이완기압을 검출할 수 있는 혈압 검출 알고리즘을 제시하였으며 그 결과 수축압, 이완압, 평균압의 절대편차 평균값은 각각 1.62%, 2.40%, 2.20%를 얻었다. 결론적으로 제안된 알고리즘은 정확한 혈압검출을 위한 유용 가능성을 보였다.

  • PDF

모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양 (Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications)

  • 우응제;박승훈;전병문;문창욱;이희철;김승태;김형진;서재준;채경명;박종찬;최근호;이왕진;김경수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF

웨어러블 디바이스를 활용한 ECG 인증 시스템 구현 및 평가 (Implementation and Evaluation of ECG Authentication System Using Wearable Device)

  • 허재욱;진선우;전문석
    • 한국산학기술학회논문지
    • /
    • 제20권10호
    • /
    • pp.1-6
    • /
    • 2019
  • IoT 기반의 스마트홈, 핀테크 등의 모바일 기술이 발달하면서 스마트 디바이스를 이용한 사용자 인증이 일상생활에서 널리 사용되고 있다. 이에 따라 기존의 비밀번호와 같은 지식 기반의 인증 방법에서 스마트 디바이스를 이용한 존재 기반의 생체인증이 새로운 주류가 되었고, 맥파, 지문, 얼굴, 홍채 등 다양한 생체인증 중에 신체적 특성상 위변조 가능성이 낮고 고유한 특징으로 개인 식별성이 높은 ECG(Electrocardiogram, 이하 ECG)를 이용한 생체인증이 헬스케어 및 핀테크와 맞물려 높은 관심을 받고 있다. 본 연구에서는 기존의 고가이면서 부피가 커 휴대가 불가능한 ECG 측정디바이스가 아닌 소형화된 웨어러블 디바이스를 이용하여 손쉽게 사용자의 ECG 파형을 측정해 사용자 인증을 할 수 있는 ECG 인증 시스템을 구현하였다. 구현된 ECG 인증 시스템은 PQRST 고유 값 식별을 통해 ECG 특징점을 판별하고 이를 이용한 제안된 인증 프로토콜로 사용자 인증이 가능하였다. 최종적으로 성인 남성 다수를 통한 측정 평가를 통해 안정적인 정지 상태에서는 1.73%의 비교적 낮은 타인수락률과 4.14%의 본인거부율을 보였고 움직임이 있는 상태에서는 13.72%의 타인수락률과 21.68%의 높은 본인거부율을 보였다. 활동으로 인해 심박수가 상승한 정지 상태에서는 10.48%의 타인수락률과 11.21%의 본인거부율을 보였다.

이미지 타입의 ECG 데이터를 사용한 CNN 모델 기반 부정맥 분류 (CNN Model-based Arrhythmia Classification using Image-typed ECG Data)

  • 방연석;장명수;홍유식;이상석;유준상;이우범
    • 융합신호처리학회논문지
    • /
    • 제24권4호
    • /
    • pp.205-212
    • /
    • 2023
  • 심장 질환 가운데에서 부정맥은 방치할 경우에 뇌졸중, 심장 마비, 심부전과 같은 심각한 합병증이 발생할 수 있기 때문에 지속적이고 정확한 심전도 관리에 의한 건강 상태의 확인은 임상적 치료에 매우 중요한 요소이다. 그러나, 심전도(Electrocardiogram; ECG) 데이터의 정확한 해석은 전적으로 의료 전문가에 의존하기 때문에 부가적인 시간과 비용을 요구한다. 따라서 본 논문에서는 라이프로그 기반의 비정상적인 맥파 파형의 분석을 통한 의료 플랫폼 개발을 목적으로 부정맥 인식 모듈을 제안한다. 제안하는 방법은 ECG 데이터를 시계열 데이터가 아닌 이미지 형식으로 처리하여 시각적 패턴 인식 기술을 적용한 후, CNN 모델을 이용하여 부정맥을 탐지하는 방법을 제안한다. 본 논문에서 제안한 ECG 데이터의 이미지 타입 변환에 의한 CNN 모델의 부정맥 분류의 유효성 검증하기 위해 MIT-BIH 부정맥 데이터셋을 사용한 결과, 97%의 정확도를 보였다.