• 제목/요약/키워드: pulse waveform

검색결과 430건 처리시간 0.036초

로보틱 토노메트리 센서를 이용한 요골 동맥 파형 정밀 측정 방법 (Precise Measurement Method of Radial Artery Pulse Waveform using Robotic Applanation Tonometry Sensor)

  • 김영민
    • 센서학회지
    • /
    • 제26권2호
    • /
    • pp.135-140
    • /
    • 2017
  • In this paper, a novel measurement method of radial artery pulse waveform using robotic applanation tonometry (RAT) was present to reduce the errors by the pressing direction of the vessel. The RAT consisted of an array of pressure sensors and 2-axis tilt sensor, which was attached to the universal joint with a linear spring and five-DOF robotic manipulator with a one-axis force sensor. Using the RAT mechanism, the pulse sensor could be manipulated to perpendicularly pressurize the radial artery. A pilot experimental result showed that the proposed mechanism could find the optimal pressurization angles of the pulse sensor within ${\pm}3^{\circ}$standard deviations. Coefficient values of variation of maximum pulse peaks extracted from the pulse waveforms were 4.692, 6.994, and 11.039 % for three channels with the highest magnitudes. It is expected that the proposed method can be helpful to develop more precise tonometry system measuring the pulse waveform on the radial artery.

초고압 XLPE 케이블 접속함의 부분방전 펄스파형 시뮬레이션 (Pulse Waveform Simulation of Partial Discharges for HV XLPE Cable Joints)

  • 김정태
    • 전기학회논문지
    • /
    • 제67권1호
    • /
    • pp.75-81
    • /
    • 2018
  • In this study, the simulation of partial discharge pulse waveform have been performed for the typical joints such as EBA and PMJ in the HV underground transmission XLPE cable system in order to improve the understanding of partial discharge pulse waveform and the on-site measurement accuracy of partial discharges. FDTD simulation technique was adopted for the simulation and has been shown to be suitable for partial discharge simulation of power cables in terms of pulse propagation characteristics and waveform formation. The simulation results for the EBA showed that the second not-so-large opposite polarity peak appeared after the first negative polarity peak and the measurement sensitivity was the highest near the bottom of the EBA copper box. In the analysis results for PMJ, the magnitude of the second opposite polarity peak was large enough to compare with the first peak, and the measurement sensitivity at the end of the PMJ copper box was the highest. These simulation results show considerable similarity with the on-site measurement, and it would be very useful for the partial discharge measurement of HV XLPE cable systems.

Effect of ramp-type erase pulse waveform on the high Temperature driving characteristics of ac PDP

  • Choi, Joon-Young;Kim, Dong-Hyun;Heo, Jeong-Eun;Ryu, Sung-Nam;Ryu, Jae-Hwa;Lee, Ho-Jun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.57-60
    • /
    • 2002
  • This paper deals with the effect of ramp-type erase pulse waveform on the high temperature driving characteristics of ac PDP driven by ramp up-down reset waveform. The experimental results show that the discharge characteristics in the reset period are significantly affected by the erase pulse waveform and ambient temperature. The firing voltage is increased with ambient temperature. This can cause misfirings during the sustain period and should be avoided. As one of possible solutions, we propose the optimization of erasing pulse shape.

  • PDF

양극파형의 펄스폭 변화에 따른 피에조 구동형 잉크젯 노즐의 액적 토출 특성 (Droplet Formation of a Piezoelectric Inkjet Nozzle According to the Variation of Pulse Widths in Bipolar Waveform)

  • 최성훈;성재용;이명호
    • 한국가시화정보학회지
    • /
    • 제10권1호
    • /
    • pp.9-14
    • /
    • 2012
  • In this study, a piezoelectric inkjet nozzle with a rectangular shaped channel has been developed, and the characteristics of droplet formation have been investigated according to the variation of pulse widths in bipolar waveform. The channel of the nozzle was fabricated transparently by a precision machining technique. A tantalum membrane which was attached to a piezoelectric material covers the channel. By applying two types of bipolar waveforms to the piezoelectric actuators, droplet formation through the nozzle was monitored by a CCD camera. For the variety of the first and second pulse widths in the bipolar waveforms, the regimes of single and double droplet formations are presented. The change of droplet velocity which depends on the pulse width and the type of waveform is also discussed.

측정가압에 의한 좌관부위(左關部位) 맥파요인 변화에 대한 실험 연구 (Study on the Difference of Pulse Waveform Parameter with Applied Variations of Pressure)

  • 김경철;이정원;류경호;강희정;임윤경
    • Korean Journal of Acupuncture
    • /
    • 제27권4호
    • /
    • pp.59-72
    • /
    • 2010
  • Objectives : In the study on the waveform analysis of radial artery pulse diagnosis, we need to establish fundaments of contemporary pulse diagnosis research, and to find the change of pulse waveform parameter with applied variation pf pressure. Methods : As we will to do experimental research on the difference of pulse waveform on the radial artery with applied variations of pressure(5 stage-pressure) and measuring position(left KWAN). In this research, we analyzed the change of the waveform according to five stage pressure. Results : The results were as follows; When we analyzed the change of the waveform according to pressure in the left KWAN, E, hl, h2 and A were the difference between 8ths pressure grades in 95% trust section. And t2, t4 were the difference between 8ths pressure grades in 95% trust section. W was the difference between 8ths pressure grades in 95% trust section. And h2/h1 was the difference between 6ths pressure grades in 95% trust section. There is the difference between 1st and 2nd grade & between 2nd and 5th grade in the case of t4/t2 in 95% trust section. And there is the difference between 1st and 5th grade, between 3rd and 4th grade, between 3rd and 5th grade & between 4th and 5th grade in the case of W/A in 95% trust section. And there is the difference between 1st and 2nd grade, between 2nd and 3rd grade, between 2nd and 4th grade, between 3rd and 4th grade, between 3rd and 5th grade & between 4th and 5th grade in the case of A/E in 95% trust section. Conclusions : We found the statistically resonable differences between each pulse depending on the applied pressure. And Analysing the radial pulse(left KWAN) at 5 applied pressure levels may be useful to study on the pulse waveform diagnosis.

토노메트리 방식 맥파 측정의 가압 각도와 가압력에 따른 AIx 변화 (AIx Change According to Pressing Angle and Pressing Force of the Radial Artery Pulse by Tonometry)

  • 조정희;전영주;전민호;김영민
    • 센서학회지
    • /
    • 제27권4호
    • /
    • pp.259-263
    • /
    • 2018
  • A radial artery pulse wave is measured while pressing an artery with constant force. However, pulse waveform measurements vary depending on pressing force and direction. Accurate pulse waveform measurements are important for analysis. Thus, it is necessary to define the measurement range of the permissible force and direction from which a correct pulse waveform is derived. In this study, pulse waves were generated by a pulse wave generator for accurate control. The pulse waves generated for different angles and pressing forces were analyzed. The augmentation index (AIx), which is the most commonly used index for evaluating vascular stiffness, was analyzed. The AIx was measured within ${\pm}6^{\circ}$ of the vessel direction and within ${\pm}8^{\circ}$ perpendicular to the vessel direction with a force that was 25% or more of the pressing force at which the maximum pressure wave was generated. We identified the applicable pressing force and angle range by analyzing the effect of pressing angle on the pulse wave. The AIx analysis performed using the pulse wave measurement device is reliable and reproducible.

실시간 공정신호를 통한 용접공정 알고리즘에 관한 연구 (A Study on Welding Process Algorithm through Real-time Current Waveform Analysis)

  • 윤진영;이영민;신순철;최해운
    • Journal of Welding and Joining
    • /
    • 제33권4호
    • /
    • pp.24-29
    • /
    • 2015
  • The current waveform was analysed to monitor the weld quality in real time process. The acquired current waveform was discretely analysed for the top and bottom limits of peaks as well as the pulse frequency measurement. Fast Fourier Transform was implemented in the program to monitor the pulse frequency in real time. The developed algorithm or program was tested for the validation purpose. The cross-section of weld profile was compared to the current waveform profile to correlate the monitored signal and the actual parts. Pulse frequency was also used as auxiliary tool for the quality monitoring. Based on the results, it was possible to evaluate the quality of welding by measure the current waveform profile and frequency measurement.

Pulse waveform을 이용한 Toner type particles의 Aging 효과 (Effect of aging toner type particles using pulse waveform)

  • 오유미;김경수;김성운;윤해상;박선우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.142-142
    • /
    • 2010
  • This research proposed an advanced Electronic bead (EB) using MMA (Methy methacrylate) and CCA (Charge Control Agent). In the first, this paper presents about measurement method and characterization analysis of EB and nano-silica with pulse waveform in aging. Furthermore; this work presents the positive and negative EB fabrication procedure. As the experimental results, the proposed EB with square waveform is very attractive to Electronic paper driving characterization.

  • PDF

A Comparative Study of Methods of Measurement of Peripheral Pulse Waveform

  • Kang, Hee-Jung;Lee, Yong-Heum;Kim, Kyung-Chul;Han, Chang-Ho
    • 대한한의학회지
    • /
    • 제30권3호
    • /
    • pp.98-105
    • /
    • 2009
  • Objective: Increased aortic and carotid arterial augmentation index (AI) is associated with the risk of cardiovascular disease. The most widely used approach for determining central arterial AI is by calculating the aortic pressure waveform from radial arterial waveforms using a transfer function. But how the change of waveform by applied pressure and the pattern of the change rely on subject's characteristics has not been recognized. In this study, we use a new method for measuring radial waveform and observe the change of waveform and the deviation of radial AI in the same position by applied pressure. Method: Forty-six non-patient volunteers (31 men and 15 women, age range 21-58 years) were enrolled for this study. Informed consent in a form approved by the institutional review board was obtained in all subjects. Blood pressure was measured on the left upper arm using an oscillometric method, radial pressure waves were recorded with the use of an improved automated tonometry device. DMP-3000(DAEYOMEDI Co., Ltd. Ansan, Korea) has robotics mechanism to scan and trace automatically. For each subject, we performed the procedure 5 times for each applied pressure level. We could thus obtain 5 different radial pulse waveforms for the same person's same position at different applied pressures. All these processes were repeated twice for test reproducibility. Result: Aortic AI, peripheral AI and radial AI were higher in women than in men (P<0.01), radial AI strongly correlated with aortic AI, and radial AI was consistently approximately 39% higher than aortic AI. Relationship between representative radial AI of DMP-3000 and peripheral AI of SphygmoCor had strongly correlation. And there were three patterns in change of pulse waveform. Conclusion: In this study, it is revealed the new device was sufficient to measure how radial AI and radial waveform from the same person at the same time change under applied pressure and it had inverse-proportion to applied pressure.

  • PDF