Effects of Electroacupuncture on Parameters Related to Obesity in Adults with Abdominal Obesity:Three arm Randomized Single Blind Pilot Study (전침이 복부비만 성인의 비만관련 지표에 미치는 영향-무작위배정 단일 맹검 예비연구-)

  • Chung, Jie-Youn;Kim, Jong-In;Lee, Sang-Hoon;Kang, Sung-Keel
    • Journal of Acupuncture Research
    • /
    • v.27 no.6
    • /
    • pp.43-57
    • /
    • 2010
  • Objectives : To investigate the effects of electroacupuncture on parameters related to obesity in adults with abdominal obesity. Methods : A three arm randomized single blind pilot study was conducted from Jan 4 to March 25, 2010 in Kyung Hee Oriental Medical Hospital. The subjects were 39 adults with abdominal obesity and were randomly divided by computer generated random table into 3 groups; EA(electroacupuncture), sham EA(sham electroacupuncture) and waitlist groups. Acupuncture points located at abdomen($CV_{12}$, $CV_6$, $ST_{25}$, $SP_{15}$, $SP_{14}$) and extremities($LI_4$, $LI_{11}$, $ST_{36}$, $ST_{44}$) were inserted by disposable stainless steel needles and were stimulated 30 minutes with 24Hz, 0.27~1.3mA(tolerable strength), asymmetric biphasic continuous pulse wave form by STN-111 Stratek device in EA group. Two treatment sessions per week for 5 weeks(10 sessions in total) were done in EA and sham EA groups. The primary outcome measurement was WC(waist circumference), and the secondary outcome measurements included WHR(waist hip ratio), ASF(thickness of abdominal subcutaneous fat), and inbody measurements of BW(body weight), BMI(body mass index), BFR(body fat ratio) and VFA(visceral fat area), and also scores of BULIT-R(bulimia test revised), KoQoL(Korean obesity of QoL) and BSQ(body shape questionnaire). Results : All of 39 subjects were included in ITT(intention-to-treat) analysis. There were significant reductions in WC, WHR and ASF after 5-week electroacupuncture treatments and the percentage reductions were significantly greater than sham EA or waitlist group. There were no significant differences between groups in percentage reductions of other parameters(BW, BMI, BFR, VFA, BULIT-R, KoQoL and BSQ). But, there were continuous reductions in BW, BMI, BFR and VFA at 3 weeks after the end of treatment and there was significant reduction in BW compared with the baseline value in EA group. No seriously adverse effects were reported during the period. Conclusions : Electroacupuncture was more effective than sham electroacupuncture or no intervention on the reduction of WC, WHR and ASF in adults with abdominal obesity.

The Strength Characteristics of Activated Multi-Component Cement with Kaolinite (카올린을 혼합한 활성화된 다성분계 시멘트의 강도 특성)

  • Kim, Tae-Wan;Kim, Im-Gon
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.593-600
    • /
    • 2016
  • The paper presented investigates the effects of kaolinite on strength properties of alkali-activated multi-component cement. The binders of this study was blended of ground granulated blast furnace slag (GGBFS), fly ash (FA), silica fume (SF) and kaolinite (KA). In this study, the specimens of combination of 20%~70% GGBFS, 10%~60% FA, 10% SF (constant ratio) and 10%~50% KA binder were used for strength properties tests. The water/binder ratio was 0.5. The binders (GGBFS + FA + SF + KA) was activated by sodium hydroxide (NaOH) and sodium silicate ($Na_2SiO_3$) was 10% by total binder weight (10% NaOH + 10% $Na_2SiO_3$). The research carried out is on the compressive strength, water absorption, ultrasonic pulse velocity (UPV) and X-ray diffraction (XRD). The compressive strength decreased as the contents of KA increase. One of the major reason for this is the low reactivity of KA compared with other raw materials used as precursors such as GGBFS or FA. The presence of remaining KA indicates that the initially used quantity has not fully reacted during hydration. Moreover, the results have indicated that increased of KA contents decreased UPV under all experimental conditions. The drying shrinkage and water absorption increased as the content of KA increase. Test result clearly showed that the strength development of multi-component blended cement were significantly dependent on the content of KA and GGBFS.

The Effects of the Communication Accompanied with Music Therapy on the Anxiety of the Patients during the MRI Examination (MRI 검사 시 음악요법을 동반한 의사소통이 환자의 불안에 미치는 영향)

  • Yoon, Yong-Hak;Yoon, Hee-Jung;Lee, Sung-Kook;Kim, Kyung-Hee;Kwon, Gi-hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.93-102
    • /
    • 2016
  • This study examined effects of the communication accompanied with music therapy on the anxiety of patients during a MRI examination. In the experiment group consisting of thirty patients and the control group consisting of thirty patients, the experiment was performed from February 1st 2014 to March 31st 2014 in hospital C located in Daegu Korea. The research design was a non-equivalent control group quasi-experimental study. The results showed that the anxiety score (VAS score) on communication with music therapy of the experimental group was significantly lower (p=.001), than that of the control group. Among the vital signs, the blood pressure was similar in both groups. On the other hand, the pulse rate of the experiment group was significantly lower (p=.001). Four categories of the physical discomfort (perspiration, facial change, change in physical posture, and change in vocal sound) did not show any statistically significant difference between the control and experiment group. Among the mental discomforts, dizziness did not have a significant difference between the experiment group and the control group, but the experimental group had significantly low fear (p=.001) and anxiety (p=.001). From the above results, communication accompanying music therapy proves is an effective alternative examination method that reduces the anxiety of patients.

A Brazing Defect Detection Using an Ultrasonic Infrared Imaging Inspection (초음파 열 영상 검사를 이용한 브레이징 접합 결함 검출)

  • Cho, Jai-Wan;Choi, Young-Soo;Jung, Seung-Ho;Jung, Hyun-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.426-431
    • /
    • 2007
  • When a high-energy ultrasound propagates through a solid body that contains a crack or a delamination, the two faces of the defect do not ordinarily vibrate in unison, and dissipative phenomena such as friction, rubbing and clapping between the faces will convert some of the vibrational energy to heat. By combining this heating effect with infrared imaging, one can detect a subsurface defect in material in real time. In this paper a realtime detection of the brazing defect of thin Inconel plates using the UIR (ultrasonic infrared imaging) technology is described. A low frequency (23 kHz) ultrasonic transducer was used to infuse the welded Inconel plates with a short pulse of sound for 280 ms. The ultrasonic source has a maximum power of 2 kW. The surface temperature of the area under inspection is imaged by an infrared camera that is coupled to a fast frame grabber in a computer. The hot spots, which are a small area around the bound between the two faces of the Inconel plates near the defective brazing point and heated up highly, are observed. And the weak thermal signal is observed at the defect position of brazed plate also. Using the image processing technology such as background subtraction average and image enhancement using histogram equalization, the position of defective brazing regions in the thin Inconel plates can be located certainly.

The Effect of Dynamic Balance on Cyber Motion Sickness of Full Immersion Virtual Reality (완전 몰입형 가상현실로 인한 사이버 멀미가 동적 균형에 미치는 영향)

  • Kim, Na-Eun;Kim, Yu-lim;Moon, Sang-cheol;Lee, Dong-hung;Lim, Ho-jeong;Jang, Eun-kyung;Hung, Ji-eun;Kang, Jong-ho
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.1
    • /
    • pp.131-138
    • /
    • 2018
  • The purpose of the study was to explore whether the Cyber Motion sickness used VR causes a change in the dynamic balance and fall. For 39 people who voluntarily participated in this study, this study measured the motion sickness questionnaires, the heart rate and stability of limit test in BioRescue. The study used Samsung Gear VR and applied the games to the To the homeland. The game proceeded 20minutes. Although the value of the stability after a VR application is slightly reduced, it did not reach statistical significance. The motion sickness questionnaires increased, and it had a statistical significant impact. Also Heart rate increased and it had a statistically significant impact. A virtual reality game affect for getting motion sickness but it did not affect the dynamic balance. So, cyber motion sickness caused by virtual reality wear does not result in decreased balance and falls.

A Study on Factors Influencing upon Right Medication of Antibiotic for Antibiotic Consumers (일부지역 항생제 소비자의 올바른 투약에 영향을 미치는 요인에 관한 연구)

  • Lee, Mi-Yung;Kim, Myung
    • Korean Journal of Health Education and Promotion
    • /
    • v.11 no.2
    • /
    • pp.48-56
    • /
    • 1994
  • In order to study the factors influencing upon right medication of antibiotic for the consumers who can easily buy antibiotic from pharmacy, the study carried out questionnaires to 568 consumers who bought antibiotics from pharmacies located in Seoul And Kyung-gi do from the 1st of February, 1994 to the 28th of the same month. Materials have been analyzed with $X^-test$ of SAS, and its results are as follows. 1. Among 568 objects of this study, the group which can medicare antibiotic properly (the right use group of antibiotic) is 45.5% with 258, while the group which does not recognize correctly the use of antibiotic or does not have any information about it (the abuse group of antibiotic) is 54.6% with 310. 2. Knowledge for advantage of antibiotic the right use group has is high in comparing with that of the abuse group (p<0.001), and also in case of pregnancy, understanding for an adverse reaction of antibiotic is high (p<0.001). The right use group has had many chances to take health education (p<0.001), and the way to buy antibiotic is very safe (p<0.001). But there is no outstanding difference for recognition of an adverse reaction of antibiotic between two groups. 3. In comparing with the abuse group, the right use group keeps well taking time of antibiotics as directions (p<0.001), and keeping rate of antibiotic dosage is high (p<0.001). Also the experiences of an adverse reaction of antibiotic is low (p<0.001). 4. In comparing with the abuse group, the right use group has high educational backgrounds (p<0.001) and many experiences of the education for health promotion (p<0.001), while there is no difference in age, sex, and economic status. 5. In comparing with the abuse group, the right use group has taken antibiotic many times (p<0.001), and there are many antibiotic takers of his/her family (p<0.01). 6. In comparing with the abuse group, the right use group has made much effort not only to check blood pressure and the pulse (p<0.05) but also for food habits (p<0.05). But there is no outstanding difference in the effort to get health information and the effort for regular exercises between these two group. 7. In comparing with the abuse group, the right use group has made an exertion in buying foodstuffs (p<0.001). But there is no big difference in efforts to keep the good attitude for physical health and mental heath, and sleeping hours between these two group.

  • PDF

Development of 2-kW Class C Amplifier Using GaN High Electron Mobility Transistors for S-band Military Radars (S대역 군사 레이더용 2kW급 GaN HEMT 증폭기 개발)

  • Kim, Si-Ok;Choi, Gil-Wong;Yoo, Young-Geun;Lim, Byeong-Ok;Kim, Dong-Gil;Kim, Heung-Geun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.3
    • /
    • pp.421-432
    • /
    • 2020
  • This paper proposes a 2-kW solid-state power amplifier (SSPA) developed by employing power amplifier pallets designed using gallium-nitride high electron mobility transistors, which is used in S-band military radars and to replace existing traveling-wave tube amplifier (TWTA). The SSPA consists of a high-power amplifier module, which combines eight power amplifier pallets, a drive amplifier module, a digital control module, and a power supply unit. First, the amplifier module and component were integrated into a small package to account for space limitations; next, an on-board harmonic filter was fabricated to reject spurious components; and finally, an auto gain control system was designed for various duty ratios because recent military radar systems are all active phase radars using the pulse operation mode. The developed SSPA exhibited a max gain of 48 dB and an output power ranging between 63-63.6 dBm at a frequency band of 3.1 to 3.5 GHz. The auto gain control function showed that the output power is regulated around 63 dBm despite the fluctuation of the input power from 15-20 dBm. Finally, reliability of the developed system was verified through a temperature environment test for nine hours at high (55 ℃) / low (-40℃) temperature profile in accordance with military standard 810. The developed SSPA show better performance such as light weight, high output, high gain, various safety function, low repair cost and short repair time than existing TWTA.

The Influence of Al2O3 on the Properties of Alkali-Activated Slag Cement (알칼리 활성화 슬래그 시멘트의 특성에 미치는 Al2O3의 영향)

  • Kim, Tae-Wan;Kang, Choong-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.205-212
    • /
    • 2016
  • This research investigates the influence of ground granulated blast furnace slag (GGBFS) composition on the alkali-activated slag cement (AASC). Aluminum oxide ($Al_2O_3$) was added to GGBFS binder between 2% and 16% by weight. The alkaline activators KOH (potassium hydroxide) was used and the water to binder ratio of 0.50. The strength development results indicate that increasing the amount of $Al_2O_3$ enhanced hydration. The 2M KOH + 16% $Al_2O_3$ and 4M KOH + 16% $Al_2O_3$ specimens had the highest strength, with an average of 30.8 MPa and 45.2 MPa, after curing for 28days. The strength at 28days of 2M KOH + 16% $Al_2O_3$ was 46% higher than that of 2M KOH (without $Al_2O_3$). Also, the strength at 28days of 4M KOH + 16% $Al_2O_3$ was 44% higher than that of 4M KOH (without $Al_2O_3$). Increase the $Al_2O_3$ contents of the binder results in the strength development at all curing ages. The incorporation of AASC tended to increases the ultrasonic pulse velocity (UPV) due to the similar effects of strength, but increasing the amount of $Al_2O_3$ adversely decreases the water absorption and porosity. Higher addition of $Al_2O_3$ in the specimens increases the Al/Ca and Al/Si in the hydrated products. SEM and EDX analyses show that the formation of much denser microstructures with $Al_2O_3$ addition.

The Effects of Music Therapy on Vital Sign Changes of operational Patients (음악요법이 수술환자의 활력징후 변화에 미치는 영향)

  • 홍순탁
    • Journal of Korean Academy of Nursing
    • /
    • v.24 no.3
    • /
    • pp.377-388
    • /
    • 1994
  • The purpose of this study was to determine the effects of music therapy on changes in the vital signs of patients about to undergo an operation. The patients listened to the music at a time when they were feeling preoperative anxiety up until the preanesthesia was given in the operating room. The subjects for this study were selected from sixty patients to undergo operations, who were hospitalized at Dong Eui hospital in Pusan city. They were assigned to two groups, thirty to the experimental group and thirty to the control group. The subjects were from 20 years old to 69 years old, and had no other problem except the one requiring the operation, and no premedication. The data were collected during the period from July 1 to September 30, 1993. The method used in this study was to measure state-anxiety on the ward in the morning of the operation, and vital signs immediately before leaving for the operating room. Vital signs were measured immediately before the anesthesia was given and after the experimental group had listened to the music during the ten minutes needed to prepare the operation setting. The control group just waited during ten mimutes. Vital signs were check again before the anesthesia was given. The data were analyzed by descriptive statistics, mean±SD, p-value, and t-test using the SPSS progrom. The results of this study are : 1. Systolic blood pressure taken in the operating room was elevated, over the level measured on the ward, by 5.00 ± 15.26㎜Hg in experimental group and 18.67±14.56㎜Hg in control group. (t=-3.5496, p=.0008) 2. Diastolic blood pressure was elevated by 6.67±12.95㎜Hg in experimental group and 18.67±12. 79㎜Hg in control group. (t=-3.6100, p=.0006) 3. Pulse was elevated by 2.931±9.44 / min in experimental group and 8.03±8.37 /min in control group. (t=-2.2144, p=.0307) 4. Respiration was elevated by 0.60±1.35 /min in experimental group and 1.57±1.48 /min in control group. (t=-2.6409, p=.0106) 5. Body temperature was down by 0.13±1.91'c in experimental group and elevated by 1.13±1.11'c in control group. (t=-3.1471, p=.0026) Thus, in this study there was a statistically significant difference in the change in the vital signs between the experimental group treated with music therapy and the control group which received no treatment. Because music therapy is valuable to decrease the anxiety of patients facing operations, the result of this study support its effect in relieving anxiety as a valuable nursing intervention. From this study, the following recommendations can be made : First, it is necessary to further study music therapy to develope a better system and determine optimal time. Second, it is necessary that more detailed re-search on measurement of changes in vital signs be done to determine changes over time intervals.

  • PDF

Design of X-band 40 W Pulse-Driven GaN HEMT Power Amplifier Using Load-Pull Measurement with Pre-matched Fixture (사전-정합 로드-풀 측정을 통한 X-대역 40 W급 펄스 구동 GaN HEMT 전력증폭기 설계)

  • Jeong, Hae-Chang;Oh, Hyun-Seok;Yeom, Kyung-Whan;Jin, Hyeong-Seok;Park, Jong-Sul;Jang, Ho-Ki;Kim, Bo-Kyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.11
    • /
    • pp.1034-1046
    • /
    • 2011
  • In this paper, a design and fabrication of 40 W power amplifier for the X-band using load-pull measurement of GaN HEMT chip are presented. The adopted active device for power amplifier is GaN HEMT chip of TriQuint company, which is recently released. Pre-matched fixtures are designed in test jig, because the impedance range of load-pull tuner is limited at measuring frequency. Essentially required 2-port S-parameters of the fixtures for extraction optimal input and output impedances is obtained by the presented newly method. The method is verified in comparison of the extracted optimal impedances with data sheet. The impedance matching circuit for power amplifier is designed based on EM co-simulation using the optimal impedances. The fabricated power amplifier with 15${\times}$17.8 $mm^2$ shows the efficiency above 35 %, the power gain of 8.7~8.3 dB and the output power of 46.7~46.3 dBm at 9~9.5 GHz with pulsed-driving width of 10 usec and duty of 10 %.