A pulse generator of one stage magnetic pulse compression modulator was simulated by electromagnetic transients program (EMTP). The pulse generator was expected to generate ${\sim}80kV$ peak voltage, ${\sim}140ns$ pulse width and about $70{\sim}75%$ energy delivery efficiency from initial charge capacitor $(0.2{\mu}F)$ to dummy load $(25{\Omega})$. From this simulation, the scheme of pulse circuit could be estimated as a practically reasonable design.
In this study, the simulation of partial discharge pulse waveform have been performed for the typical joints such as EBA and PMJ in the HV underground transmission XLPE cable system in order to improve the understanding of partial discharge pulse waveform and the on-site measurement accuracy of partial discharges. FDTD simulation technique was adopted for the simulation and has been shown to be suitable for partial discharge simulation of power cables in terms of pulse propagation characteristics and waveform formation. The simulation results for the EBA showed that the second not-so-large opposite polarity peak appeared after the first negative polarity peak and the measurement sensitivity was the highest near the bottom of the EBA copper box. In the analysis results for PMJ, the magnitude of the second opposite polarity peak was large enough to compare with the first peak, and the measurement sensitivity at the end of the PMJ copper box was the highest. These simulation results show considerable similarity with the on-site measurement, and it would be very useful for the partial discharge measurement of HV XLPE cable systems.
Objectives: The aim of this study was to examine the controversial issues about objective structured clinical examination (OSCE) of pulse diagnosis and investigate the objectification of traditional Korean medicine and technical feasibility of pulse simulation through the suggestion of a pulse simulator. Methods: The concept, validity and reliability of OSCE and the current situation of medical simulation was described. The actual level and problems on the simulator development was presented through haptics and tactile technology in order to compose a pulse simulator for OSCE. Results: The pulse wave system of a pulse simulator should materialize through haptic technology and the classification of the differences between tactile sensation and tactile quality is essential for the development of the relevant pulse simulator for OSCE in traditional Korean medicine. Conclusions: The introduction and controversial issues of OSCE and methodology of pulse wave reappearance system are proposed for the objectification of Traditional Korean Medicine and the development of clinical technology.
In this paper, we designed and implemented a precise pulse motor controller chip that generates the pulse needed to control step motor, DC servo and AC servo motors. This chip generates maximum pulse output rate of 5Mpps and has the quasi-S driving capability and speed and moving distance override capability during driving. We designed this chip with VHDL and executed a logic simulation and synthesis using Synopsys tool. The pre-layout simulation and post-layout simulation was executed by Compass tool. This chip was produced with 100 pins, PQFP package by 0.8${\mu}{\textrm}{m}$ gate array process and implemented by completely digital logic. We developed the test hardware board of performance and the CAMC(Computer Aided Motor Controller) Agent softwate to test the performance of the pulse motor controller chip produced. CAMC Agent enables user to set parameters needed to control motor with easy GUI(Graphic User Interface) environment and to display the output response of motor graphically.
The high-voltage pulse generator is consist of transformers of fundamental wave and harmonic waves, and shunt capacitances. The pulse has the fundamental wave and the harmonic waves that have been increased as a series circuit by the transformers to make high voltage pulse. This paper shows the high-voltage pulse generator simulation using a circuit program with experiment data. In the equivalent circuit, magnetized inductances and loss resistances which affect output voltage, have been obtained. The output capacitor circuits have characteristics of band pass. The output voltages of the pulse width 50% and 25%(PWM) were obtained. The output of the high-voltage pulse generator is 2.5kHz, 1.8kV.
Journal of Advanced Marine Engineering and Technology
/
제28권7호
/
pp.1138-1144
/
2004
In order to improve engine performance while overcoming the weak points of Pulse and MPC(Modular Pulse Converter) turbocharging system, a new turbocharging system. "Hi-Pulse system", has been introduced and developed for medium speed diesel engine. HYUNDAI HiMSEN engines. Hi-Pulse system is to utilize not only the benefits of MPC system at higher load but also the ones of Pulse system at lower load. As for the results. the specific fuel oil consumption and NOx emission were lowered compared with the Pulse and MPC system. Performance simulation were carried out to optimize intake and exhaust timing and exhaust duct arrangement and to improve the performance of Hi-Pulse system engine.em engine.
Because linear motor directly drives linear motion, it does not need conversion equipment such as belt and gear. Especially linear pulse motor provide more precise positioning and large force of linear pulse motors. As current manufacture technic of linear pulse motor is much to be desired at home. This motor lay out to make use of computer aided design program, In this paper the experimental motor is 2-phases 4-poles hybrid pulse motor which has teeth per pole Simulation program is divided its function into 4 parts - air gap permeance analysis, permanent magnet & non-linear core operating point determine, winding configuration, leakage flux analysis. It is possible to make motor static and magnetic characteristics for this simulation program. Also, by varying input parameters of the program, experimental motor is to be compared to motor characteristics.
We numerically solve the nonlinear Schrödinger equation for pulse propagation in a passively mode-locked Yb:KGW laser. The soliton-like pulse formation as a result of balanced negative group-delay dispersion (GDD) and nonlinear self-phase modulation is analyzed. The cavity design and optical parameters of a previously reported high-power Yb:KGW laser were adopted to compare the simulation results with experimental results. The pulse duration and energy obtained by varying the small-signal gain or GDD reproduce the overall tendency observed in the experiments, demonstrating the reliability and accuracy of the model simulation and the optical parameters.
A Miniature inertance pulse tube refrigerator was designed and tested with a 10 W compressor. Erperiments were carried out for different pulse tube length and inertance tube length. An adiabatic model which considered the pressure drop in the regenerator was used to analyze the performance of the pulse tube refrigerator. Among various design parameters which should be optimized, the pulse tube length and the inertance tube length were optimized. PdV work and several different loss mechanism were included in the analysis to simulate more accurately the physical phenomena in the pulse tube refrigerator. Nevertheless, the simulation program could not completely predict the porformance of the refrigerator. The possible reason for the difference of the optimal point between the simulation and the experiment was explained.
The purpose of this study was to find more effective method through comparison of manual chest compression and chest compression using $AutoPulse^{TM}$ device in pre-hospital simulation cardiac arrest. In order to achieve the purpose of the study, ambulance workers did two different style CPR in pre-hospital simulation cardiac arrest. Data analyzed by T test and ANOVA. Findings of this study are as follows. Firstly, manual chest compression is more effective than chest compression using $AutoPulse^{TM}$ device on scene. Secondly, chest compression using $AutoPulse^{TM}$ device is more effective manual chest compression in ambulance and in elevator. In conclusion, these findings provide strong evidence for the importance of hands off time and stable CPR before hospital arrival in explaining patient's prognosis. Therefore, strategies to conduct precise hands off time and stable CPR are needed to improve patient's prognosis.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.