• Title/Summary/Keyword: pulse signal

Search Result 1,442, Processing Time 0.025 seconds

Development of 60KV Pulse Power Supply using IGBT Stacks (IGBT 직렬구동에 의한 60KV 펄스 전원장치 개발)

  • Ryoo, H.J.;Kim, J.S.;Rim, G.H.;Sytykh, D.;Gussev, G.I.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.917-918
    • /
    • 2006
  • In this paper, a novel new pulse power generatorbased on IGBT stacks is proposed for pulse power application. Proposed scheme consists of series connected 9power stages to generate maximum 60kV output pulse and one series resonant power inverter to charge DC capacitor voltage. Each power stages are configured as 8 series connected power cells and each power cell generates up to 850VDC pulse. Finally pulse output voltage is applied using total 72 series connected IGBTs. The synchronization of gating signal is importantfor series operation of IGBTs. For gating signal synchronization, full bridge inverter and pulse transformer generates on-off signals of IGBT gating and specially designed gate power circuit was used.

  • PDF

Estimation of Respiration Using Photoplethysmograph During Sleep (광용적맥파 신호를 이용한 수면 중 호흡 추정)

  • Park, Jong-Uk;Lee, Jeon;Lee, Hyo-Ki;Kim, Hojoong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.105-110
    • /
    • 2013
  • Respiratory signal is one of the important physiological information indicating the status and function of the body. Recent studies have provided the possibility of being able to estimate the respiratory signal by using a change of PWV(pulse width variability), PRV(pulse rate variability) and PAV(pulse amplitude variability) in the PPG (photoplethysmography) signal during daily life. But, it is not clear whether the respiratory monitoring is possible even during sleep. Therefore, in this paper, we estimated the respiration from PWV, PRV and PAV of PPG signals during sleep. In addition, respiration rates of the estimated respiration signal were calculated through a time-frequency analysis, and errors between respiration rates calculated from each parameter and from reference signal were evaluated in terms of 1 sec, 10 sec and 1 min. As a result, it showed the errors in PWV(1s: $36.38{\pm}37.69$ mHz, 10s: $36.53{\pm}38.16$ mHz, 60s: $30.35{\pm}38.72$ mHz), in PRV(1s: $1.45{\pm}1.38$ mHz, 10s: $1.44{\pm}1.37$ mHz, 60s: $0.45{\pm}0.56$ mHz), and in PAV(1s: $1.05{\pm}0.81$ mHz, 10s: $1.05{\pm}0.79$ mHz, 60s: $0.56{\pm}0.93$ mHz). The errors in PRV and PAV are lower than that of PWV. Finally, we concluded that PRV and PAV are more effective than PWV in monitoring the respiration in daily life as well as during sleep.

Study on Timing Characteristics of High-Voltage Pulse Generation with Different Charging Voltages

  • Lee, Ki Wook;Kim, Jung Ho;Oh, Sungsup;Lee, Wangyong;Kim, Woo-Joong;Yoon, Young Joong
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.1
    • /
    • pp.20-28
    • /
    • 2018
  • The time synchronization of each sub-unit of a pulsed generator is important to generate an output high-power radio frequency (RF) signal. To obtain the time synchronization between an input RF signal fed by an external source and an electron beam produced by an electric pulse generator, the influence of different charging voltages on a delay and a rise time of the output pulse waveform in the electric pulse generator should be carefully considered. This paper aims to study the timing characteristics of the delay and the rise time as a function of different charging voltages with a peak value of less than -35 kV in the high-voltage pulse generator, including a trigger generator (TG) and a pulse-forming line (PFL). The simulation has been carried out to estimate characteristics in the time domain, in addition to their output high-voltage amplitude. Experimental results compared with those obtained by simulation indicate that the delay of the output pulses of the TG and PFL, which are made by controlling the external triggering signal with respect to different charging voltages, is getting longer as the charging voltage is increasing, and their rise times are inversely proportional to the amplitude of the charging voltage.

Design and Response Analysis of Wideband Monopulse Radar System Robust to Noise Jamming Signal (잡음 재밍 신호에 강인한 광대역 모노펄스 레이더 시스템 설계 및 응답 특성 분석)

  • Shin, Bohun;Yang, Haejoon;Kim, Changyeol;Park, Soryoung;Noh, Sanguk;Nam, Ilku
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.94-102
    • /
    • 2018
  • In this paper, the wideband mono-pulse radar using AGC and limiter is designed. The output response characteristics of the mono-pulse radar using AGC and limiter are analyzed, respectively. In addition, the output response for jamming input signals is analyzed. The range tracking loop in the mono-pulse radar has robust output response to the noise jamming input signal. Although the output settling response of the AGC-based mono-pulse radar is larger than that of the limiter-based mono-pulse radar, the AGC-based mono-pulse radar has robustness to the noise jamming input signal due to feedback loop.

A Study of PPG Wave and Pulse Measurement on Radial Artery Using Digital Potentiometer and Exponentially Weighted Moving Average Filter (디지털 가변저항과 지수가중 이동평균필터를 통한 요골동맥에서의 PPG 파형과 맥박 측정에 관한 연구)

  • Jung, In-Bok;Kim, Kyung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.962-967
    • /
    • 2014
  • In this paper, through a digital potentiometer and exponentially weighted moving average filter, pulse and PPG waveform measurable device was fabricated in radial artery. If this device is not proper about signal size in analog part, MCU can judge easily by adjusted amplification through digital potentiometer, using exponentially weighted moving average filter is able to filter out more clear value of ADC. I presumed pulse rate as value of measuring time between point of maximum contraction from sensing signal in radial artery of wrist. Therefore, this means can measure stable pulse rate and PPG waveform, finger as well as radial artery, whether signal size of each person is different finger as well as radial artery.

Improvement of Power Spectrum in Ultrashort Pulse Reflectometry Signals Using Three Chirp Configuration

  • Roh, Young-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.51-56
    • /
    • 2014
  • The flat power spectrum of the transmitter output signal for the desired frequency range is ideal to achieve the best performance of ultrashort pulse reflectometry. However, the power spectrum of a typical pulse generator decreases significantly as frequency increases. A configuration of three chirped waveforms was employed to improve the power spectrum of the transmitter signal at higher frequencies. To determine the amplification gain required for higher frequency components, three chirped waveforms were theoretically generated and their power spectra were measured using numerical band-pass filters. Based on the results of numerical computations, the three chirp configuration was successfully applied to the design of the transmitter for a broadband system.

Current Control Type Pulse Width Modulation by Using Pair Transistor Circuit (쌍트란지스터 회로에 의한 전류제어형 펄스변조)

  • 오현위
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.4
    • /
    • pp.7-16
    • /
    • 1971
  • A negative resistance element in the form of current control can be obtained by using a pair transistor circuit. This negative resistance element can be used in the generation of square pulse, and also in the realization of pulse width modulation circuit by superposing signal current on its bias current. The each bias current of pair circuit increases alternatively according to the polarity of the input signal. In order to satisfy this condition, a modified full wave rectification circuit has been adopted for supplying the input signal. Theoritical analysis of pulse times and design guidances for practical modulation circuit parameters are presented.

  • PDF

SpO2 Measurement Algorithm for PPG Signal with Motion Artifacts (동잡음을 가진 PPG 센서에서의 산소포화도 측정 알고리즘)

  • Jang, Seong-Jin;Choi, Kue-Lak;Park, Keun-Hae;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.192-198
    • /
    • 2018
  • Pulse oximetry is a non-invasive method for monitoring how much oxygenated hemoglobin is present in the blood. The principle of pulse oximetry is based on the red infrared light adsorption characteristics of oxygenated and deoxygenated hemoglobin. Even through the convenience of a pulse oximeter, its weak signal-to-noise ratio against motion artifacts and low perfusion makes it difficult to be accepted by execs devices. Several researchers have suggested the use of an adaptive noise cancellation (ANC) algorithm. They have demonstrated that ANC is feasible for reducing the effects of motion artifacts. Masimo Corporation developed a discrete saturation transformation (DST) algorithm that uses a reference signal and ANC. In commercial devices, it is very hard to escape it because Masimo's patents are very powerful and a better method is yet to be developed. This study proposes a new method that can measure noise saturation as well as accurate oxygen saturation from signals with high motion artifacts without using ANC and DST. The proposed algorithm can extract a normal signal without noise from a signal with motion artifacts. The reference signal from a pulse oximeter simulator was used for the evaluation of our proposed algorithm and achieved good results.

NMR Functional brain Imaging with the Tailored RF Pulse (TAILORED RF PULSE를 이용한 NMR에서의 뇌 기능 영상법)

  • Ro, Y.M.;Cho, Z.H.;Mennon, R.S.;Ugurbil, K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.21-24
    • /
    • 1993
  • The experimental results of visual stimulation with the tailored RF pulse are reported. Tailored RF pulse is used for the susceptibility effect imaging. Around 25% signal change of visual cortex area is detected during photic stimulation. Interestingly, with the tailored RF pulse, the signal intensity of visual cortex is deceased during photic stimulation. It is, however, increased with normal $T_2$ weighted imaging. The comparison between normal $T_2$ weighted imaging and the tailored RF pulse imaging are performed with 4T NMR system and the results with human volunteer are also presented.

  • PDF

Generation and Characteristics of Exponential Pulse Shaping Functions using Chebychev Identity Equation and Bessel Coefficients (Chebychev 항등식과 Bessel 계수를 이용한 지수펄스모형함수 생성 및 특성)

  • Lee, Jeong-Jae;Park, Sun-Kwang
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.1
    • /
    • pp.60-65
    • /
    • 2009
  • In this paper, we propose a new exponential pulse shaping function based on Chebychev identity equation and Bessel coefficients. The proposed pulse shaping function can produce various pulses with the different characteristics in the time and frequency domain by changing its two parameters. By differentiating the exponential pulse shaping function, we obtain new different pulse functions, in which the even order derivatives of the exponential pulse shaping function are orthogonal to its odd order derivatives. To find the efficiency of the proposed exponential pulse shaping function we analyze its essential characteristics and compare them with those of the conventional Gaussian pulses. We can choose the most suitable exponential pulse waveform according to the design criteria of communication systems.

  • PDF