• 제목/요약/키워드: pulse sensor

검색결과 541건 처리시간 0.026초

홀 센서의 양극 바이어스 수직모드를 이용한 맥파측정시스템 구현 (Implementation of the Pulse Wave Measurement System Using Bipolar Biased Head on Mode of the Hall Sensor)

  • 진상곤;김명남
    • 센서학회지
    • /
    • 제20권5호
    • /
    • pp.322-328
    • /
    • 2011
  • There are many ways to detect the heart rate non-invasively such as ECG, PPG, strain gauge, and pressure sensor. In this paper, the pulse wave measurement system using bipolar biased head on mode of the Hall sensor is proposed for measuring the radial artery pulse. TMS320F2812 was used to implement the proposed system and a portable wireless network(zig-bee) was used to show the experimental result. It was confirmed from experiment that the performance of the implemented system was more stable and faster than PPG sensor or piezoelectric film pressure sensor.

새로운 맥파 인식 알고리즘을 적용한 자동 맥파 시스템에 관한 연구 (A Study on the Auto-diagnosis Plethysmograph by Novel Algorithm for Radial Pulse Detection)

  • 박승환;홍승홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권2호
    • /
    • pp.241-246
    • /
    • 1996
  • This paper describes a new system that detects radial pulse wave and allows the diagnosis of malfunctions of cardiovascular system by analyzing the waveforms with the newly proposed algorithm. The system consists of a sensor part and a data processing part within which a new detection algorithm is incorporated In acquiring radial pulse signal noninvasively, the sensor used in this system is a new combinational fiber-optic sensor which has a detecting Part and a transmitting Part. Also, In order to analyze the characteristics of pulsation quantitatively, the algorithm proposed in this paper is a method that runs in parallel with both the data of ECG and differential pulse simultaneously. these concepts are based upon the idea that thfee Q points of ECG give obious discrimination of one entire period of pulse in any abnormal cases, and newly defined feature lines at the differential counterpart can be used to recogrlize sDme significant points in one period of pulses.

  • PDF

펄스파 자왜 센서를 이용한 고정밀 액위 센서 시스템의 실현에 관한 연구 (Implementation of High Accurate Level Sensor System using Pulse Wave Type Magnetostriction Sensor)

  • 최우진;이준탁
    • 전기학회논문지
    • /
    • 제62권3호
    • /
    • pp.395-400
    • /
    • 2013
  • In this paper, we introduce the implementation of high accurate level sensor system using the pulse wave type magnetostriction sensor. When a current pulse flows along the waveguide, the magnetic field also propagates towards the end of waveguide. When this magnetic field just passes the position of the magnet for level detection, the resultant magnetic field by these two magnetic fields makes a torsional reflected signal. This is used to calculate the time difference between a interrogation pulse wave and this torsional reflected signal. The key elements and characteristics were investigated to implement level sensor system based on this principle. We introduce a method to calculate the speed of ultrasonic reflected signal and how to make a model of sensing coil. In particular, we experiment with the characteristics of the torsional reflected signal according to the changes of the interrogation voltage and displacement. To make high accurate level sensor system, two methods were compared. One is to use the comparator and time counter, the other is STFT(Short Time FFT) which is capable of the time-frequency analysis.

희수식 전자 맥진기의 재조명 (Study on Reillumination of Hi-soo type Electronic Manometer)

  • 김은혜;김병수;강정수
    • 혜화의학회지
    • /
    • 제18권2호
    • /
    • pp.37-45
    • /
    • 2009
  • In early 1970s, Electronic Manometers were researched and developed for modernization and objectification of pulse diagnosis. Method of finger pressing, also known as cuffs pressing, is essential for sensing a pulse wave. I think comprehension and deduction of problem from the existing Hi-soo type electronic manometer, will be important for making a better one. The Hi-soo type electronic manometer is constructed of cuff pressing type sensor, differential amplifier, transmitter and recorder. Pulse movement and pulse wave, gauging blood flow, is analyzed by pulse image of "Yixuerumen(醫學入門)". At standard of pulse wave, huanmai(緩脈) is distinguish from chishu(slow and fast, 遲數), fushen(float and sink, 浮沈), interference wave, modificated wave, and phase angel. The Hi-soo type electronic manometer had no explanation of formational mechanism, significantly different with pulse wave which is early known and reported. The strength of Hi-soo type electric manometer is use of cuff pressing type sensor. Above all, the importance of electric manometer is reading the pulse movement accurately then expressing it as pulse wave. From now on the improvement of precise sensor should make a progress.

  • PDF

Development of a Sleep-driving Accident Prevention System based on pulse

  • Bae, Seung-Woo;Seo, Jung-Hwa
    • 한국인공지능학회지
    • /
    • 제6권1호
    • /
    • pp.11-15
    • /
    • 2018
  • The purpose of this study is to develop a pulsatile drowsiness detection system that can compensate the limitations of existing camera - based or breathing pressure sensor based Drowsiness driving prevention systems. A heart rate sensor mounted on the driver's finger and an alarm system that sounds when drowsiness is detected. The heart rate sensor was used to measure pulse changes in the wrist, and an alarm system based on the Arduino, which works in conjunction with the laptop, generates an audible alarm in the event of drowsiness. In this paper, we assume that the pulse rate of the drowsy state is 60 ~ 65 times / minute, which is the middle between the awake state and the sleep state. As a result of the experiment, the alarm sounded when the driver's pulse rate was in the drowsy pulse rate range. Based on these experiments, the drowsiness detection system was able to detect the drowsiness of the driver successfully in real time. A more effective drowsiness prevention system can be developed in the future by incorporating the results of the present study on a pulse-based drowsiness prevention system in an existing drowsiness prevention system.

비침습적 맥파 측정을 위한 압력센서 패키징에 관한 연구 (Pressure Sensor Packaging for Non-invasive Pulse Wave Measurement)

  • 김은근;남기창;허현;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1978.1_1979.1
    • /
    • 2009
  • In this paper, we have proposed and demonstrated a tonometry sensor array for measuring arterial pulse pressure. A sensor module consists of 7 piezoresistive pressure sensor array. Wire-bonded connection was provided between silicon chip and lead frame. PDMS(poly-dimethylsiloxane) was coated on the sensor array to protect fragile sensor while faithfully transmitting the pressure of radial artery to the sensor. Tonometric pulse pressure can be measured by this packaged sensor array that provides the pressure value versus the output voltage.

  • PDF

FEM 분석을 통한 맥진센서모듈의 패키징 형태와 응력분포 (Finite Element Analysis of Packaging Shape for Pulse Diagnosis Sensor)

  • 신기영;이상식;주수빈
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권3호
    • /
    • pp.167-173
    • /
    • 2011
  • 맥파를 정량적으로 측정하기 위해 다양한 맥진기가 개발되어 왔으며, 맥진기는 비침습적으로 맥파를 측정하기 위해 압력센서를 이용한다. 이러한 맥진기에 사용되는 맥진 센서 모듈은 압력센서와 압력센서의 와이어링을 보호하기 위한 코팅이 사용되는데, 코팅의 재질 또는 모양에 따라 측정 겨로가에 영향을 미칠 수 있다. 본 논문에서는 맥진센서에 압력을 가하였을 때 PDMS 코팅 형태에 따라 압력센서에 전달되는 응력분포를 비교하기 위해 6종류의 코팅모델에 두 가지 방법의 압력을 가하여 유한요소해석을 실시하였다. 결과적으로 맥진센서 중앙에 압력을 가하여 해석을 수행 하였을 때 맥진센서 모듈의 PDMS 코팅두께를 0.3mm씩 줄일수록 중앙의 압력센서에 전달되는 응력은 24%씩 증가하였고 주변의 압력센서로 전달되는 응력은 4.9%씩 감소하였다. 그리고 코팅에 가이드가 있는 경우 주변 압력센서로 전달되는 응력의 비율이 2.7% 더 적게 나타났다.

Piezo Film Sensor를 이용한 생체 정보 검출 (Detection the Biomedical Information using the Piezo Film Sensor)

  • 이한욱;서환;정원근;장두봉;이건기
    • 한국정보전자통신기술학회논문지
    • /
    • 제3권3호
    • /
    • pp.14-21
    • /
    • 2010
  • 유비쿼터스 헬스케어 환경을 위해서는 생체 정보를 실시간으로 정확하게 측정하는 것이 중요할 뿐만 아니라, 이러한 생체 정보 측정 장치는 저전력으로 설계되어져야 한다. 본 논문에서는 지금까지 사용되어 오던 손가락 프로브의 불편함을 없애기 위해 피에죠 필름 센서를 이용하여 손목의 요골 동맥으로부터 심장의 동기 신호인 맥파를 측정하였다. 본 논문에서는 두장의 피에죠 필름 센서를 이용하여 맥파신호와 동잡음 참조 신호를 추출하여 적응 잡음 제거기에 적용함으로써, 동잡음 제거된 맥파 신호를 얻을 수 있었다. 동잡음 제거된 맥파 신호를 이용하여 생체 정보를 얻을 수 있었다.

  • PDF

Piezo Film Sensor를 이용하여 상완 동맥에서 맥박 측정을 위한 센서부 최적 구조에 관한 연구 (A study on the optimum configuration of sensor part for measurement of pulse using piezo film sensor in brachial artery)

  • 조성현;김신자;이영우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 추계학술대회
    • /
    • pp.441-443
    • /
    • 2009
  • Piezo Film Sensor를 이용하여 팔뚝의 상완 동맥에서 맥박 측정을 위한 센서부 최적 구조에 관한 연구를 하였다. 탈부착이 쉬운 팔뚝형 밴드 형태에 Piezo Film Sensor를 삽입하여 생체 신호를 측정 하였다. 센서부의 최적 구조를 알기 위해서 센서패드 구조물의 형태에서 매질 및 두께를 변화시켜 가면서 생체 신호의 크기를 비교하였다.

  • PDF

실내 공기질 향상을 위한 비분산 적외선 이산화탄소 가스센서 (NDIR CO2 Gas Sensor for Improving Indoor Air Quality)

  • 이승환;박정민;박영환;한승오
    • 한국전기전자재료학회논문지
    • /
    • 제18권7호
    • /
    • pp.628-634
    • /
    • 2005
  • We have simulated and proposed novel optical cavity, which has two elliptical mirrors, for NDIR gas sensor module and have tested it from 0 ppm to 2,000 ppm $CO_2$ concentration. The proposed sensor module shows the maximum peak voltage at 500 ms pulse modulation time, however, it shows a maximum voltage changes at 200 ms pulse duration with 18,000 times amplification gain. From 0 ppm to 2,000 ppm, the voltage difference of sensor module $({\Delta}V)$ shows 360 mV at 200 ms pulse duration and 3 sec turn-off time. The response time of designed sensor module is about 30 seconds.