• 제목/요약/키워드: pulse protocol

검색결과 82건 처리시간 0.024초

Collision-Free Arbitration Protocol for Active RFID Systems

  • Wang, Honggang;Pei, Changxing;Su, Bo
    • Journal of Communications and Networks
    • /
    • 제14권1호
    • /
    • pp.34-39
    • /
    • 2012
  • Collisions between tags greatly reduce the identification speed in radio frequency identification (RFID) systems and increase communication overhead. In particular for an active RFID system, tags are powered by small batteries, and a large number of re-transmissions caused by collisions can deteriorate and exhaust the tag energy which may result in missing tags. An efficient collision-free arbitration protocol for active RFID systems is proposed in this paper. In this protocol, a new mechanism involving collision detection, collision avoidance, and fast tag access is introduced. Specifically, the pulse burst duration and busy-tone-detection delay are introduced between the preamble and data portion of a tag-to-reader (T-R) frame. The reader identifies tag collision by detecting pulses and transmits a busy tone to avoid unnecessary transmission when collision occurs. A polling process is then designed to quickly access the collided tags. It is shown that the use of the proposed protocol results in a system throughput of 0.612, which is an obvious improvement when compared to the framed-slotted ALOHA (FSA) arbitration protocol for ISO/IEC 18000-7 standard. Furthermore, the proposed protocol greatly reduces communication overhead, which leads to energy conservation.

Effects of Acupuncture Stimulation on the Radial artery's Pressure Pulse Wave in Healthy Young Participants: Protocol for a prospective, single-Arm, Exploratory, Clinical Study

  • Shin, Jae-Young;Ku, Boncho;Kim, Tae-Hun;Bae, Jang Han;Jun, Min-Ho;Lee, Jun-Hwan;Kim, Jaeuk U.
    • 대한약침학회지
    • /
    • 제19권3호
    • /
    • pp.197-206
    • /
    • 2016
  • Introduction: This study aims to investigate the effects of acupuncture stimulation on the radial artery's pressure pulse wave, along with various hemodynamic parameters, and to explore the possible underlying mechanism of pulse diagnosis in healthy participants in their twenties. Methods and analysis: This study is a prospective, single-arm, exploratory clinical study. A total of 25 healthy participants, without regard to gender, in their twenties will be recruited by physicians. Written informed consent will be obtained from all participants. The participants will receive acupuncture once at ST36 on both sides. The radial arterial pulse waves will be measured on the left arm of the subjects by using an applicable pulse tonometric device (KIOM-PAS). On the right arm (appearing twice), electrocardiogram (ECG), photoplethysmogram (PPG), respiration and cardiac output (CO) signals, will be measured using a physiological data acquisition system (Biopac module), while the velocity of blood flow, and the diameter and the depth of the blood vessel will be measured using an ultrasonogram machine on the right arm (appearing twice). All measurements will be conducted before, during, and after acupuncture. The primary outcome will be the spectral energy at high frequencies above 10 Hz ($SE_{10-30Hz}$) calculated from the KIOM-PAS device signal. Secondary outcomes will be various variables obtained from the KIOM-PAS device, ECG, PPG, impedance cardiography modules, and an ultrasonogram machine. Discussion: The results of this trial will provide information regarding the physiological and the hemodynamic mechanisms underlying acupuncture stimulation and clinical evidence for the influence of acupuncture on the pressure pulse wave in the radial artery. Ethics and dissemination: This study was approved by the Institutional Review Board (IRB) of Kyung Hee University's Oriental Medical Center, Seoul, Korea (KOMCIRB-150818-HR-030). The study findings will be published in peer-reviewed journals and presented at national and international conferences. Trial registration number: This trial was registered with the Clinical Research Information Service (CRIS) at the Korea National Institute of Health (NIH), Republic of Korea (KCT0001663), which is a registry in the World Health Organization's (WHO's) Registry Network.

Implementation of a No Pulse Competition CPS-SPWM Technique Based on the Concentrated Control for Cascaded Multilevel DSTATCOMs

  • Wang, Yue;Yang, Kun;Chen, Guozhu
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1139-1146
    • /
    • 2014
  • Digital signal processor (DSP) and field programmable gate array (FPGA) based concentrated control systems are designed for implementing CPS-SPWM strategies. The self-defined universal asynchronous receiver/transmitter (UART) protocol is used for communication between a master controller and an individual module controller via high speed links. Aimed at undesired pulse competition, this paper analyzes its generation mechanism and presents a new method for eliminating competition pulses with no time delay. Finally, the proposed concentrated controller is applied to a 10kV/10MVar distribution static synchronous compensator (DSTATCOM) industrial prototype. Experimental results show the accuracy and reliability of the concentrated controller, and verify the superiority of the proposed elimination method for competition pulses.

유해가스(CO, CO2) 감지정보 전송을 위한 USN 지그비센서노드 구현 (A Study on the USN Zigbee Sensor Node for Transmission to Harmful Gas(CO, CO2) Sensing Data)

  • 천동진;박영직;이승호;김정섭;곽동걸;정도영
    • 전기학회논문지
    • /
    • 제59권7호
    • /
    • pp.1302-1308
    • /
    • 2010
  • In this study, Zigbee Sensor Node to transmit harmful gases CO and $CO_2$ information using wireless communication within the ground and underground structures were developed. Wireless communication protocol was used Zigbee Stack included IEEE 802. 15.4 MAC protocol. For wireless transmission of detected harmful gas signal from ADC of MCU was implemented Zigbee Sensor Node that was developed protocol using Serial-Port-Profile(SPP) here. The proposed Zigbee Sensor Node was verified transmission distance from experiments. Transmission distance was into 90m in experiments. Distance experiments were measured at 10m intervals using sine & pulse wave input signal at indoors. The proposed Route Sensor Node was applied mesh routing protocol. When built up USN(Ubiquitous Sensor Network)using Route Sensor Node, transmission distance was not limited. On the experimental results, harmful gas values between direct measurements and USN measurements were consistent. The semiconductor CO sensor and N-DIR $CO_2$ sensor module as a harmful sensor was used. Therefore, the proposed Zigbee Sensor Node was verified about reliability and validity to build USN for transmission of harmful gas information.

SIP기반의 VoIP시스템에서 RTP를 이용한 Voice 처리 모듈의 개발 (Design of Voice processing module Using RTP in VoIP system)

  • 윤원동;백은경;박일규;최양희
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2001년도 봄 학술발표논문집 Vol.28 No.1 (A)
    • /
    • pp.292-294
    • /
    • 2001
  • VoIP(Voice over IP) system은 현재 크게 2가지 형태로 진행되어가고 있다. 첫 번째는 H.323을 이용한 방법이고, 두 번째는 SIP(Session Initiation Protocol)를 이용한 방법이다. H.323은 실제 데이터를 전송하기전 호처리에 많은 signaling이 이루어지는 관계로 SIP보다 많은 RTT(Round Trip Time)를 소모하게 된다. 따라서 매우 복잡하고, LAN환경을 바탕으로 만들어서 확장성면에서도 여러 문제점을 가지고 있다. 그래서 본 논문은 호처리는 SIP를 이용하고, 실제 음성전송은 RTP(Real-Time Transport Protocol)와 RTCP(RTP Control Protocol)를 이용하는 시스템 구현을 제시한다. RTP는 실시간 특성을 가지는 데이터에 대해서 종단간 전송 서비스를 제공해주는 프로토콜로, 어떠한 인코딩에도 적합한 프레임워크를 제공한다. 그런데, RTP는 완전한 하나의 프로토콜이 되기 위해서는 RTP와 페이로드 포맷이 함께 제공되어야 하므로, 구현시스템은 음성신호를 PCM(Pulse Code Modulation), ADPCM(Adaptive Differential PCM)등의 여러 압축기술을 이용하여 파일을 생성하여 실시간으로 RTP와 RTCP를 이용하여 전송하는 방법을 제시한다.

Developmental Rate of Rabbit Parthenogenetic Embryos Derived Using Different Activating Protocols

  • Chrenek, P.;Makarevich, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제17권5호
    • /
    • pp.617-620
    • /
    • 2004
  • The present study compares development of rabbit embryos generated using different oocyte activation protocols and reconstructed with embryonic or cumulus cells as nuclear donor. In vivo matured oocytes were collected from New Zealand White rabbits at 16 h after ovulation treatment and were activated at18 h of post-ovulation treatment. The following schemes of oocytes activation were tested: 1) single electric pulse (EP, 3.2 kV/cm, 3${\times}$20 $\mu$s, 0.3 M mannitol)+5 min culture in the presence of 5 mM Ionomycin, 2) single electric pulse (EP, 3.2 kV/cm, (${\times}$20 $\mu$s, 0.3 M mannitol)+1 h culture in the presence of 2 mM 6-DMAP, and 3) three electric pulses 30 min apart. Cleavage rate, percentage of expanded and hatched blastocysts as well as total cell number of blastomeres of parthenogenetic embryos were significantly higher using either EP+6-DMAP or 3${\times}$EP schemes, comparing with EP+Ionomycin. Development rate up to hatched blastocyst stage of cloned rabbit embryos using the EP+6-DMAP for activation of nuclei were 19% for embryonic cell nuclei and 36% for cumulus cell nuclei. The best activation protocol optimalized in this study was the combined treatment "P+6-DMAP" which may be potentially used for nuclear transfer protocol.

디지털 x-ray 영상시스템을 위한 무선 트리거 발생기 (Wireless Triggering Pulse Generation for Digital X-ray Imaging System)

  • 고대식;이재철;이주신
    • 한국항행학회논문지
    • /
    • 제11권2호
    • /
    • pp.163-169
    • /
    • 2007
  • 본 논문에서는 x-ray 영상시스템의 영상을 획득하기 위하여 x-ray 발생기와 영상획득시스템 사이의 동기를 맞추어 주는 트리거 발생기를 연구분석 하였다. 무선 트리거 발생기는 디지털영상 획득시스템으로부터 영상획득의 시작을 지시할 수 있는 ACQ_START 신호와 영상획득의 끝을 알리는 ACC_END 신호를 발생시킬 수 있도록 설계하였다. 디지털 영상의 획득은 ACQ_START 신호와 ACQ_END 신호 사이의 시간동안에만 정확하게 이루어지며 무선 원격 x-ray 신호의 검출을 통하여 유선통신 프로토콜 없이 정확한 x-ray 영상의 획득이 가능하고 20 mAs 의 x-ray 레벨에서 3.5 line pair /mm 분해능을 나타냄을 확인하였다.

  • PDF

전기자극 변조방식이 체성감각에 미치는 영향 (Effects of Modulation Type on Electrically-Elicited Tactile Sensation)

  • 황선희;아라 조샨;송동진;배태수;박상혁;강곤
    • 한국정밀공학회지
    • /
    • 제29권7호
    • /
    • pp.711-716
    • /
    • 2012
  • The purpose of this study was to investigate how the modulation method affects the effectiveness of eliciting tactile sensations by electrical stimulation. Two methods were employed and the results were compared and analyzed; pulse amplitude modulation (PAM) and pulse width modulation (PWM). Thirty-five healthy subjects participated in the experiments to measure the stimulation intensity that began to elicit a tactile sensation - activation threshold (AT). Constant-current monophasic rectangular pulse trains were employed, and the stimulation intensity was varied from zero until the subject felt any uncomfortable sensation. The step size of the stimulation intensity was 100nC/pulse. After each experiment, the subject described the sensation both quantitatively and qualitatively. The two modulation methods did not make a significant difference as far as the AT values were concerned, but most of the subjects showed 'intra-individual' consistency. Also, it was confirmed that our range of the stimulation parameters enabled us to obtain three major tactile sensations; tickling, pressure and vibration. The results suggested that the stimulation parameters and the modulation type should be selected for each individual and that selective electrical stimulation of the mechanoreceptors needs more diversified researches on the electrode design, multi-channel stimulation protocol, waveforms of the pulse train, etc.

하프 브릿지 푸쉬 풀 DC/DC 컨버트를 이용한 전자석 전원 개발 (Development of Magnet Power Supply using Half Bridge Push Pull DC/DC Converter)

  • 김성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2030-2032
    • /
    • 1998
  • It is always necessary to high performance power supplies for the magnet system in the accelerator, especially when the number of power supplies are large. When have developed the compact power supply using switching technology instead of SCR phase control. We adopt the pulse width modulation(PWM) method with a half bridge DC/DC converter. In this way, we can make a compact system with light weight and small volume. Actual system we developed is 1.2kW, 35V/35A bipolar DC power supply current precision of +/-0.02%. It is possible to mount 10 unit in a conventional 19 rack. The built in controller has an RS422 protocol to drive 10 unit by one serial port up to 1.2km distance. If we adopt RS485 protocol, one serial port can control 32 power supplies. In this paper, we will report the design and performance of the prototype power supply.

  • PDF