• Title/Summary/Keyword: pulse pressure variation

Search Result 61, Processing Time 0.032 seconds

Ecophysiological Interpretations on the Water Relations Parameters of Trees(VII) - Measurement of Water Flow by the Heat Pulse Method in a Larix leptolepis Stand - (수목(樹木)의 수분특성(水分特性)에 관(關)한 생리(生理)·생태학적(生態學的) 해석(解析)(VII) - Heat pulse법(法)에 의한 낙엽송임분(林分)의 수액류속(樹液流速) 계측(計測) -)

  • Han, Sang Sup;Kim, Sun Hee
    • Journal of Korean Society of Forest Science
    • /
    • v.82 no.2
    • /
    • pp.152-165
    • /
    • 1993
  • This is the basic study in order to know the amount of transpirational water loss in a Larix leptorepis stand by a heat pulse method. Especially this study has been measured and discussed the diurnal and seasonal trends of heat pulse velocity by changes of radiation, temperature and humidity, differences of heat pulse velocity by direction and depth in stem, differences of heat pulse velocity by dominant, codominant and suppressed trees, diurnal change of heat pulse velocity by change of leaf water potential, sap flow path way in sapwood by dye penetration and amount of daily and annual transpiration in a tree and stand. The results obtained as follows : 1. Relation between heat pulse velocity(V) and sap flow rate(SFR) was established as a equation of SFR=1.37V($r=0.96^{**}$). 2. The sap flow rate presented in the order of dominant, codominant and suppressed tree, respectively. The daily heat pulse velocity was changed by radiation, temperature and vapor pressure deficit. 3. The heat pulse velocity in individual trees did not differ in early morning and in late night, but had some differed from 12 to 16 hours when radiation was relatively high. 4. The heat pulse velocity and leaf water potential showed similar diurnal variation. 5. The seasonal variation of heat pulse velocity was highest in August, but lowest in October and similar value of heat pulse velocity in the other months. 6. The heat pulse velocity in stem by direction was highest in eastern, but lowest in southern and similar velocity in western and northern. 7. The difference of heat pulse velocity in according to depths was highest in 2.0cm depth, medium in 1.0cm depth, and lowest in 3.0cm depth from surface of stem. 8. The sap flow path way in stem showed spiral ascent turning right pattern in five sample trees, especially showed little spiral ascent turning right in lower part than 3m hight above ground, but very speedy in higher than 3m hight. 9. The amount of sap flow(SF) was presented as a equation of SF=1.37AV and especially SF in dominant tree was larger than in codominant or suppressed tree. 10. The amount of daily transpiration was 30.8ton/ha/day and its composition ratio was 83% at day and 17% at night. 11. The amount of stand transpiration per month was largest in August(1,194ton/ha/month), lowest in May (386ton/ha/month). The amount of stand transpiration per year was 3,983ton/ha/year.

  • PDF

A study on the variation of skin temperature on the adult male at environment temperature (각 환경기온하에서의 성인남자 피부온에 관한 연구)

  • 심부자
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.71-88
    • /
    • 1996
  • For understanding skin temperature based on clothing design from a viewpoint of comfortable wearing, the skin temperature, physiological reactions(body temperature, blood pressure and pulse) and physilolgical response(thermal sensation, comfort sensation and perceptive sweaty sensation) were measured on condition tha t5 naked healthy male exposed to serveral environmental temperatures,( $20{\pm}1.0^{\circ}C$ ,$28{\pm}1.0^{\circ}C$ and $32{\pm}1.0^{\circ}C$). As the results of this testing, the regional skin temperature was varied for 90min just after expose to those the environment but was generally stabilized for the nest 90min. It was proved the difference of the regional skin temperature at low temperature environmental($20{\pm}1.0^{\circ}C$) was larger than at high temperature environmental($32{\pm}1.0^{\circ}C$) and inder serveral environmental temperature,the degree of the regional skin was not equal. Except in case of the thigh, the front of all regional skin temperature turned out higher than the back of them. According to change of environmental temperature, body temperature and pulse were altered. In the pshycological response, 'thermal sensation-comfort sensation' was felt to 'slightly warm - comfortable' at $28{\pm}1.0^{\circ}C$of the environmental temperature, and 'perceptive sweaty sensation', wneh it was said 'sweat' at only $32{\pm}1.0^{\circ}C$ of it.

  • PDF

Development of the Pneumatic Servo Valve

  • Kim, Dong-Soo;Choi, Byung-Oh;Kim, Kwang-Young;Lee, Won-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1146-1151
    • /
    • 2003
  • Pneumatic servo valve is an electro-mechanical device which change electric signals to a proper pneumatic signals, that is, flowrate and pressure. In this study, a pneumatic servo valve was designed and each simulation was conducted on any variation in the flowrate depending upon the magnetic force of the linear force motor and the displacement of the spool. And permanent magnet was used as a material for the plunger of the servo valve. Thereby, a low electrical power consumption type coil was desinged. And a modeling for the coil design was conducted by using the magnetic circuit. also, the feasibility of the modeling was verified by using a commercial magnetic field analysis program. The designed and fabrication of the spool and sleeve, position sensor, servo controller and the dynamic characteristic verified by the experiment.

  • PDF

Implementation of nonlinear two-mass vocal folds digital model (성대의 비선형 2-mass 디지털 모델 구현)

  • Lee, Hui-Sung;Chung, Myung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.9-11
    • /
    • 2004
  • The vocal folds play an important role to produce glottal pulse which is an essential factor of phonation. There have been some models which implement the vocal folds' dynamics, such as one-mass model, two-mass model, multi-mass model and ribbon model. Among them, this paper uses nonlinear two-mass model, which is simple structure and produces similarly real glottal pulses and vocal folds' vibration, to realize vocal folds digital model. The pattern of movements in vocal folds will be shown in this paper by using vocal folds digital model. It will be verified how initial position of vocal folds. variation of tension and change of lung pressure influences vibration and glottal pulses.

  • PDF

Development Test of 1 N Attitude Control Thruster (1 N급 자세제어용 추력기의 개발 시험)

  • 이재원;김인태;정세용;장기원;황종선;허환일
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.35-38
    • /
    • 2003
  • The purpose of this work is to introduce the 1-N grade thruster development program for attitude control of satellites and lunch vehicle systems. Characteristics of the thruster and its performance have been evaluated through hot-firing test of small liquid engine inside a vacuum test cell. Performance evaluation of thruster were made with a variation of propellant injection pressure at steady state and pulse firing mode, respectively. Also hot-fire test system and test procedure are briefly described, too.

  • PDF

Electric Spark System as Underwater Acoustic Source - I. Pressure pulses from low electric energy - (수중음원으로써의 전기방전시스템- I. 낮은 전기에너지로부터의 음압펄스 -)

  • Kim, Sung-Boo;Kim, Sang-Han
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.32-35
    • /
    • 1996
  • The pressure pulses generated from the underwater electric spark system ranged from 0.4 to 1.6kJ are measured with the variation of source depth and range. The characteristics of pressure pulses obtained through this experiment continue to show the same electric energy and depth dependence previously reported, but two particular phenomena are observed. First, it is observed that the peak pressure of the 1st bubble pulse induced from implosion is higher than that of the initial shock wave, which is particularily apparent to high electric energy more than 10kJ previous studies. Second, it has been reported that the energy ratio (potential energy of bubble/intrinsic energy of source) has some tendency to "droop" on the low electric energy as 0.02 for 5kJ and 0.01 for 1kJ but the results of the present experiment show that it continues to have the ratio of 0.01 near 1kJ again.

  • PDF

Variation of Cardiopulmonary Function by Use of Building Stairs (건물 계단 이용에 따른 심폐기능의 변화)

  • Yi, Seung-Ju
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.2
    • /
    • pp.989-995
    • /
    • 1996
  • This study was conducted to investigate variation of cardiopulmonary function by use of building stairs, a questionnair survey and measurement was carried out for 50 students of department of physical therapy Andong Junior College from 20th September to 3rd October, 1995. The result were as follows: The average systolic blood pressure(SBP) of stability for 50 college students who were measured was 121.3 mmHg, the average diastolic blood pressure(DBP) of stability was 78.5 mmHg, the average pulse frequency of stability was 71.8(frequency/min), the average breathing frequency of stability was 20.4(frequency/min), and the body temperature of stability was $36.8^{\circ}C$. SBP among the second, third, and fourth floors was 129.0 mmHg, 127.0 mmHg, and, 132.0 mmHg (p=0.1919), DBP was 80.1 mmHg, 76.5 mmHg, and, 82.0 mmHg (p=0.4229), the pulse frequency was 74.0, 73.1, and 74.0(frequency/min). The breathing frequency among the second, third, and fourth floors was statistically gradually increased according to 21.4, 23.1 and 24.6(frequency/min)(p=0.0071). The body temperature among the second, third, and fourth floors was statistically less and less decreased according to $36.8^{\circ}C,\;36.6^{\circ}C$ and $36.5^{\circ}C$(p=0.0040). It was revealed by this study, the breathing frequency among the second, third, and fourth floors was statistically significant increased, the body temperature was statistically significant decreased.

  • PDF

A Study on the Impulse Waves Discharged from the Exit of the Convergent/Divergent Pipes (축소/확대관 출구로부터 방출되는 펄스파에 관한 연구)

  • Lee, D.H.;Ju, K.M.;Kim, H.S.;Kim, H.D.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.640-645
    • /
    • 2001
  • The present study is to investigate the characteristics of the impulse waves discharged from the exit of the convergent and divergent pipes. An experiment is carried out using a shock tube with an open end and is compared to the computation of the axisymmetric, compressible, unsteady Euler equations, which are solved by the second-order total variation diminishing(TVD) scheme. For the computational work, some initial compression waves are assumed inside the pipe so that those are identical to the experimental ones of the shock tube. The results show that the peak pressures of the impulse waves discharged from the exit of convergent and divergent pipes decrease with an increase in the wavelength of the initial compression wave. All of the impulse waves have a strong directivity toward the pipe axis, regardless of the exit type of the pipe employed. The impulse waves discharged from the divergent pipe are stronger than those from the straight pipe, while the impulse waves of the convergent pipe are weaker than those from the straight pipe. It is believed that the convergent pipe can playa role of a passive control to reduce the peak pressure of the impulse wave. The present computations represent the experimented impulse waves with a good accuracy.

  • PDF

Development of cryogenic free-piston reciprocating expander utilizing phase controller

  • Cha, Jeongmin;Park, Jiho;Kim, Kyungjoong;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.2
    • /
    • pp.42-47
    • /
    • 2016
  • A free-piston reciprocating expander is a device which operates without any mechanical linkage to a stationary part. Since the motion of the floating piston is only controlled by the pressure difference at two ends of the piston, this kind of expander may indispensably require a sophisticated active control system equipped with multiple valves and reservoirs. In this paper, we have suggested a novel design that can further reduce complexity of the previously developed cryogenic free-piston expander configuration. It is a simple replacement of both multiple valves and reservoirs by a combination of an orifice valve and a reservoir. The functional characteristic of the integrated orifice-reservoir configuration is similar to that of a phase controller applied in a pulse tube refrigerator so that we designate the one as a phase controller. Depending on the orifice valve size in the phase controller, the different PV work which affects the expander performance is generated. The numerical model of this unique free-piston reciprocating expander utilizing a phase controller is established to understand and analyze quantitatively the performance variation of the expander under different valve timing and orifice valve size. The room temperature experiments are carried out to examine the performance of this newly developed cryogenic expander.

A Study of ADS Slip Ratio Control using Solenoid Valve (전자밸브를 이용한 ABS 슬립율 제어에 관한 연구)

  • Choi, Jong-Hwan;Kim, Sung-Su;Yang, Soon-Yong;Park, Sung-Tae;Lee, Jin-Kul
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.676-681
    • /
    • 2001
  • ABS is a safety device, which adds hydraulic system to the existing brake system to prevent wheel from locking, so we can obtain maximum braking force on driving. The hydraulic system to control braking pressure consists of sol-flow type using solenoid valve, flow control valve or consists of sol-sol type using two solenoid valve. In this paper, the hydraulic system in ABS is composed of sol type using a 3port-2position solenoid valve, and vehicle system is composed of 1/4 vehicle model. And slip ratio is controlled using PWM (Pulse-Width-Modulation) control algorithm. Braking friction coefficient and tracking friction coefficient which are described by slip ratio's function have maximum value when slip ratio has its value from 0.1 to 0.3. And slip ratio is controlled constantly in this boundary value even in the variation of road's condition in some boundary.

  • PDF