• Title/Summary/Keyword: pulse period

Search Result 567, Processing Time 0.029 seconds

Comparative Study on the Pulse Wave Variables and Sasang Constitution in Cerebral Infarction Patients and Healthy Subjects (뇌경새(腦梗塞) 환자(患者)와 건강인(健康人)의 맥상(脈象)과 사상체질(四象體質)에 관(關)한 연구(硏究))

  • Ko, Ki-Duk;Kim, Kyung-Yo;Kim, Jong-Yeol;Lee, Si-Woo;Joo, Jong-Cheon
    • Journal of Pharmacopuncture
    • /
    • v.10 no.2 s.23
    • /
    • pp.119-132
    • /
    • 2007
  • This study was performed to determine whether a pulse analyzer was useful 1) to characterize the variables of pulse wave of cerebral infarction patieno (CI), compared with those of healthy subjects, as well as 2) to determine Sasang Constitution in CI and healthy subjects. 1. Calibrated in Gwan, the amount of energy(Energy), height of main peak(H1), height of aorticvalley(H2), height of aortic peak(H3), total area of pulse wave(At), and area of main peak width(Aw) of the CI group were higher than those of the healthy group. 2. Calibrated in Cheek, Energy, H1, H2, H3, height of valve valley(H4), At, Aw, and main peak angle(MPA) of the CI group were higher than those of the healthy group. 3. Among the healthy (subjects) group, Taeumin showed the highest contact pressure(CP) and height of valve peak(H5) calibrated in Chon. The main peak width divided by whole time of pulse wave(MPW/T) calibrated in Gwan and Cheok, was highest in Soyangin and was lowest in Taeumin. The H3 divided by H1(H3/H1) and the time to valve valley minus the time to main peak and divided by T[(T4-T1)/T] calibrated in Cheek were highest in Soyangin. The time to main peak(T1) was longest in Soumin. 4. Among the CI group, At calibrated in Chon was widest in Taeumin and was narrowest in Soumin The time to aortic peak(T3) calibrated in Cheek was longest in Soumin and was shortest in Soyangin. The time to valve peak(T5) was shortest in Soyangin. 5. There were main effects of cerebral infarction in the area of systolic period(As) and area of diastolic period(Ad) calibrated in Chon, Energy calibrated in Cwan, and Energy, H1, H2, H3, (H4+H5)/Hl, and MPA calibrated in Cheek. 6. There were main effects of Sasang Constitution in (T4-T1)/T, area of systolic period(As), and Ad calibrated in Chon. 7. The interactions between the cerebral infarction and Sasang Constitution were observed in H5/H1 , T, At, As, Ad, and MPA calibrated in Chon, H4, T4, (T4-T1)/T, As, and Ad calibrated in Cwan, and 74,75, and MPW calibrated in Cheok. Therefore, we concluded that pulse analyzer was useful to determine the risk degree of cerebral infarction and Sasang Constitution.

A Sequential Design of Dual Pulse Generation System Based on Dynamic Analysis of Pulse Shape (이중충격파의 충격파형 동특성 분석에 근거한 충격시험장치의 순차적 설계)

  • Kang, Minsig;Shul, Changwon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.98-107
    • /
    • 2017
  • Electric components equipped with naval shipboards must endure mechanical shock caused by various mechanical impulsive sources. Thus the components must be designed carefully and reliability test is an essential procedure before use. In this study, a new design technology applicable to a large and heavy shock generation system which can generate various specific real mechanical shocks in specified time domain was introduced. Commonly, the shock transmitted through the wall of naval shipboard consists of dual shocks. The primary shock is of a very high amplitude and very short period half-sine form. The following shock is of an exponentially decaying harmonic form of relatively longer period. Based on the different dynamic characteristics of two shocks, we proposed a sequential design procedure to determine spring and damping coefficients of the generation system. Some numerical simulation results showed the feasibility of the proposed method.

DeNOx modeling in $N_{2}/O_{2}$ gas by pulsed corona discharge ($N_{2}/O_{2}$ 혼합가스에서 펄스코로나 방전을 이용한 NOx 제거 모델링에 관한 연구)

  • Park, Kwang-Seo;Lee, Hyoung-Sang;Chun, Bae-Hyeock;Shin, Hyun-Ho;Yoon, Woong-Sup;Chun, Kwang-Min
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.117-128
    • /
    • 1999
  • The removal of nitrogen oxides(NOx) from $N_{2}/O_{2}$ gas using a pulsed corona discharge was investigated as a function of the reduced electric field(E/N) and the energy density(J/L). A kinetic model was developed to characterize the chemical reactions taking place in a pulsed corona discharge reactor. The model calculates the fractional concentrations of radical species at each pulse-on period and utilizes the radicals to remove NOx for the subsequent pulse-off period. Electron collision reaction data are calculated using ELENDIF program to solve Boltzmann equation for electron energy distribution function, and the subsequent chemical reactions are calculated using CHEMKIN-II program to solve stiff ODE(ordinary differential equation) problems for species concentrations. The corona discharge energy per pulse and the time-space averaged E/N were obtained by fitting the model to experimental data. The model calculation shows good agreement with the experimental data, and predicts the formation of other species such as $NO_{2}$, $O_{3}$ and $N_{2}O$.

  • PDF

Effect of Intermittent Versus Continuous Infusion of Progesterone on LHRH Release In Viuo from the Rat Mediobasal Hypothalamus

  • 김경진
    • The Korean Journal of Zoology
    • /
    • v.32 no.4
    • /
    • pp.329-338
    • /
    • 1989
  • Present study examined the effect of intermittent versus continuous infusion of progesterone(P) on LHRH release in uiuo from the mediobasal hvpothalamus of ovariectomiEed, estradiol-primed adult rats bearing push-pull cannulae. Three experimental groups were studied: 1) control (perfusion medium only),2) intermittent perfusion of P (10-min on,20-min off, and 3) continuous perfusion of p. p (10 ng/mll was directly infused into the MBH following a 3 hr basal collection. Perfusates were collected at 10 min intents린s on ice and LHRH release was measured by LHRH radioimmunoassav. Cycle detector analysis revealed that the spontaneous HRH output in the control group was pulsatile over a 7 hr push-pull perfusion period. The mean basal LHRH release, pulse amplitude and pl서se period were 0.68 $\pm$ 0.03 ps110 min, 1.15 $\pm$0.08 pg and 60 $\pm$ 9 min, respectivelv. Intermi구eat perfusion of P clearly stimulated the mean LHRH release (pre-P vs post-P: 1.14 $\pm$ 0.18 vs 1.99 $\pm$ 0.53 pg) without changes in LHRH pulse frequency. In contrast to intermittent infusion of p, continuous administration of P faithed to modify LHRH release, since the mean LHRH release and pulse amplitude between pre-P and post-P perfusion urere similar. The in vitro study clearly showed that intermittent, but not continuous administration of P is effective in stimulating LHRH release. Therefore, it appears that rhythmic secretion of P mal be the erective signal for activating the neural LHRH apparatus.

  • PDF

On the improvement of inelastic displacement demands for near-fault ground motions considering various faulting mechanisms

  • Esfahanian, A.;Aghakouchak, A.A.
    • Earthquakes and Structures
    • /
    • v.9 no.3
    • /
    • pp.673-698
    • /
    • 2015
  • This paper investigates inelastic seismic demands of the normal component of near-fault pulse-like ground motions, which differ considerably from those of far-fault ground motions and also parallel component of near-fault ones. The results are utilized to improve the nonlinear static procedure (NSP) called Displacement Coefficient Method (DCM). 96 near-fault and 20 far-fault ground motions and the responses of various single degree of freedom (SDOF) systems constitute the dataset. Nonlinear Dynamic Analysis (NDA) is utilized as the benchmark for comparison with nonlinear static analysis results. Considerable influences of different faulting mechanisms are observed on inelastic seismic demands. The demands are functions of the strength ratio and also the pulse period to structural period ratio. Simple mathematical expressions are developed to consider the effects of near-fault motion and fault type on nonlinear responses. Modifications are presented for the DCM by introducing a near-fault modification factor, $C_N$. In locations, where the fault type is known, the modifications proposed in this paper help to obtain a more precise estimate of seismic demands in structures.

Changes in Circulatory and Respiratory Activities Observed on Men in an Engine Room of a Navy Ship (함정 기관실내 활동의 순환 및 호흡 기능에 대한 영향)

  • Hyun, Kwang-Chul;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.1 no.2
    • /
    • pp.199-213
    • /
    • 1967
  • Circulatory and respiratory activities were observed in men exposed to the environment of engine room of a cruising Republic of Korea Navy ship and compared to the control values obtained in an ordinary laboratory room on land. The environment of an engine room of cruising navy ship was presumed to be a multiple stress acting on men. The environment of the engine room included high temperature $(35-42^{\circ}C)$, low relative humidity (20-38% saturation), vibration (about 7 cycles per second), rolling and pitching of ship and noises. Sixteen men were divided into two groups consisted of each 8 subjects. Subjects of sea duty group had experience of continuous on board duty averaging 3.5 years. Men of land duty group had no experience of on board activity. On land observations were made on one day prior to the boarding and leaving the port and four days after landing. In between observations in the engine room were made on the first, 5 th, 9 th, 12 th, and 14 th day of on board activity. The whole experimental period lasted for 20 days. Measurements on circulatory and respiratory parameters were at standing resting state (after 30 minutes standing in the case of on land study and 15 minutes in engine room study) and within one minute after cessation of on the spot running of which rhythm was 30/min. and lasted for 5 minutes. Oxygen consumption and pulmonary function test were done in the period of two minutes from the 3rd to 5th minutes of running. The following results were obtained. 1. Body temperature showed no change regardless of group difference or on land or on board measurements. 2. Pulse rate increased markedly after boarding the ship id both groups. Pulse rate increased from the first day on board at rest and after exercise as compared to the on land control value. This increase in pulse rate was more marked after exercise. Sea duty group showed less increase in pulse rate at rest than the land duty group. Standing and resting pulse rate of sea duty group on lam was 81 and increased to 87 at the 5th day on board and remained smaller than the land duty group throughout the period on board. Control standing and resting pulse rate of land duty group on land was 76 and reached 89 at the 9th day on board and thereafter decreased a little. Pulse rate of land duty group at rest on board remained greater than that of sea duty group throughout the period on board. 3. Systolic blood pressure of sea duty group increased after boarding the ship and remained higher than the control value on land. In the land duty group, however, systolic blood pressure decreased during the period on board the ship. Diastolic blood pressure decreased in both groups. 4. Resting breathing rate of land duty group increased and remained higher than the control value on land. In sea duty group, however, resting breathing rate showed a transient increase on the 1st day on board and decreased thereafter to the control value on land and kept the same level throughout the period of cruise. Absolute value of breathing rate in the sea duty group was greater than the land duty group both at rest and after exercise. 5. There was a lowering of breathing efficiency in both groups. Thus, increases in tidal volume and minute ventilation volume and decreases in maximum breathing capacity, vital capacity, capacity ratio and air velocity Index were observed after boarding the ship. An increase in ventilation equivalent was also observed in both groups. The lowering of breathing efficiency was more marked in the land duty group than the sea duty group. 6. Energy expediture increased in both groups during their stay on the ship and was more marked in the sea duty group. 7, Lactate concentration in venous blood at rest and after exercise increased after boarding the ship and no group difference was observed.

  • PDF

A Study on characteristics of the forward type high frequency pulse power supply for lamp type ozonizer (램프형 오존발생기용 Forward type 고주파 펄스 전원장치의 특성에 관한 연구)

  • 김경식;김동희;이광식;원재선;송현직
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.2
    • /
    • pp.89-96
    • /
    • 2000
  • This paper describes the forward type pulse power supply which is the simple circuit configuration and easy to be managed using a power semiconductor switching device(Power-MOSFET) in the view of commercialization. The maximum value of output pulse voltage of the proposed pulse power supply system can be realized by the variation of phase angle($\phi$) of bridge rectifier circuit and also its pulse period is determined by the duty ratio of Power-MOSFET. The principle of basic operating and the operating characteristics of the forward type pulse power supply are estimated by the switching frequency, the variation of phase angle($\phi$)It is shown that theoretical and experimental results are in good agreement by comparing simulation and experimental results of proposed pulse power supply when a lamp type ozonizer can be used as a load. This proposed pulse power system shows that it can be practically used in the future as a power source system in various fields.

  • PDF

A Study on Images of the Pulse Diagnosis (맥진(脈診)에 관한 도상(圖像)연구)

  • Han, Bong-Jae
    • Korean Journal of Oriental Medicine
    • /
    • v.15 no.2
    • /
    • pp.101-109
    • /
    • 2009
  • The Pulse diagnosis is in the boundary of the Four Examinations, and it is called 切診, or palpation. It has a great impact on people in reminding of the Traditional Medicine that it is probably the first thing that people think of when they hear about Traditional Medicine. Hu-Jun quoted in the Treasured Mirror of Eastern Medicine "東醫寶鑑" that the doctor finds out the deficiency and the excess of the meridian of the patiant through the pulse, and that it is of the utmost necessity to know the "deficiency and the excess" of the meridian to decide the formula (君臣佐使) of the herbal medicine and the acupuncture/moxibustion treatment. The research on the studies of pulse diagnosis have been concentrated on the origin, history, and the theory of the pulse diagnosis throughout the years; however, the number of research on the image from the classics on pulse diagnosis have been less. With this in mind, this paper was written to study more on the origin and the history of the pulse diagnosis as well as to study on the image of pulse diagnosis shown on the classics on Traditional Medicine in China and Korea. The history of the pulse diagnosis has its root on the attempt to find out what is happening inside the body through the indication of the small changes of the pulse that is shown on the outer boundaries of the body. There were various kinds of pulse diagnosis including "Three positions and nine indicators method" and "Carotid pulsation and wrist pulse method" in the ancient period, and wrist pulse-taking method became the most popular since the completion of studying on palpation by 初보. The image of the palpation helps the rudimentary practitioners of Traditional Medicine. They are divided into two large categories, which are the area of diagnosis and the shape of the pulse itself. The historical classics including the image of the pulse diagnosis can be found since the Song Dynasty of China. There are various kinds of image of pulse diagnosis in the classic such as "The picture of the hand meridian" from "脈訣指掌病式圖說", "The picture of the image of meridian" from "察病指南", "The picture of the Seven exterior and Eight interior" from "校正圖注脈訣", and "The picture of the six parts of meridian" from Treasured Mirror of Eastern Medicine "東醫寶鑑". The Treasured Mirror of Eastern Medicine "東醫寶鑑" have analyzed the basic theories and made up the standards of pulse diagnosis by establishing "The picture of the six parts of meridian" based on "The method of placing the viscera and bowels corresponding to cun-guan-qi, or the meridian".

  • PDF

COMMON-MODE VOLTAGE PULSE CANCELLATION METHOD BASED ON SPACE-VECTOR PWM IN CONVERTER-INVERTER SYSTEM

  • Lee, Hyeoun-Dong;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.171-175
    • /
    • 1998
  • This paper proposes the advanced PWM method that can reduce common-mode voltage in three-phase PWM converter-inverter system. By the proper distribution of the zero-voltage vector of inverter, it is possible to cancel out a common-mode voltage pulse in a sampling period. Since the proposed PWM method maintains the effective-voltage vector, it does not affect the control performance of converter-inverter system. Without any extra hardware, overall common-mode voltage can be decreased by one-third compared with conventional PWM scheme.

  • PDF

Study about the Application of Rogowski Coil for measuring Partial Discharge Current (부분방전전류측정을 위한 로고스키코일의 적용에 관한 연구)

  • Lee, Kang-Won;Yoon, Sung-Cheol;Kim, Myung-Yong;Baik, Kwang-Sun;Na, Dong-Hee
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1378-1383
    • /
    • 2004
  • Rogowski coil is a kind of sensor for high amplitude and very short period current and suitable for the measurement of PD pulse. This paper have simulated the relations between PD signals and Rogowski coil which has its own equivalent circuit and investigated signals of Rogowski coil induced by PD pulse current. and compared with the PD signal obtained from conventional PD measuring system in accordance with IEC60270.

  • PDF