• 제목/요약/키워드: pulse input method

검색결과 242건 처리시간 0.021초

Modeling and Optimization of RMS Pulse Width for Transmission in Dispersive Nonlinear Fibers

  • Lee, Jong-Hyung
    • Journal of the Optical Society of Korea
    • /
    • 제7권4호
    • /
    • pp.258-263
    • /
    • 2003
  • Simple algebraic expressions are derived to approximate the optimal input RMS pulse width and the resulting output RMS pulse width in single-mode fibers. The results are compared with the previously published methods and with numerical results by the split-step Fourier method. In addition, for a transform-limited Gaussian input pulse, it is shown that there is no optimum input pulse width to minimize the output spectrum width. Finally, with fiber nonlinearity, it is shown mathematically that there is not an optimum input pulse width to minimize the product,${\sigma}_t{\sigma}_{\omega}$, which is inversely proportional to the transmission capacity of WDM systems.

6시그마 기법을 통한 안정된 맥파측정 프로세스 설계 (A Case Study of Six Sigma Project for Improving method of measuring pulse wave)

  • 이전;이유정;이혜정;최은지;김종열
    • 한국한의학연구원논문집
    • /
    • 제12권2호통권17호
    • /
    • pp.85-92
    • /
    • 2006
  • Pulse is one of the basic diagnostic information of TKM(Traditional Korean Medicine). To quantify and standardize pulse diagnosis, we had collected an amount of clinical data from May 2005 by using newly developed pulse analyzer. But there were many noises in pulse wave according to measuring method, environment, operator and condition of patient. So some data can’t be included for analyzing diagnosis. To reduce noises from measuring pulse and to collect reliable pulse wave data, we made the process map of measuring method and applied six sigma project. With this we can improved the method of measuring pulse wave in collecting clinical data. The project follows a disciplined process of five macro phases: define, measure, analyze, improve and control (DMAIC). A process map and C-E diagram are used to identify process input and output variables. The major input variables are selected by using C&E matrix, and process map is developed by analyzing input variables. And the optimum process conditions are going to be controled to avoid in increasing loss of collecting pulse wave data.

  • PDF

극박 다이아프램의 펄스 GTAW 공정 최적화에 관한 연구 (Study on the Optimization of Pulse GTAW Process for Diaphragm with Thin Thickness)

  • 박형진;황인성;강문진;이세헌
    • Journal of Welding and Joining
    • /
    • 제26권1호
    • /
    • pp.63-68
    • /
    • 2008
  • This paper has aimed to prevent excessive heat input by controlling arc distribution and heat input capacity with pulse GTAW in order to improve weld quality in 0.08mm pressure gauge diaphragm and flange welding parts. A design of experiment was designed using Box-Behnken method to optimize a welding process. The pulse GTAW parameters such as pulse current, base current, pulse duty, frequency and welding speed were set to input variables while hydraulic pressure that represents welding characteristics in diaphragm and flange joint were set to output variables. Based on the test result, a second regression equation was obtained between input and output variables and turned out significant. Besides, an influence of parameters has been confirmed through response surface analysis using the second-order regression equation and optimum welding condition was obtained through a grid-search method. The optimum welding condition was set to pulse current 84.4(A), base current 29.6(A), pulse duty 58.8(%), frequency 10(%), and welding speed 596(mm/min). Then, decent bead shape was acquired with no excessive heat input under the $2.3kgf/cm^2$ of hydrostatic pressure.

입력 변압기 없는 3상 멀티-펄스 콘버터의 고조파 저감 (Harmonic Reduction of Three Phase Multi-Pulse Converter Circuit without Input Transformer)

  • 박현철;김영민;황종선;김종만
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 센서 박막재료 반도체재료 기술교육
    • /
    • pp.128-131
    • /
    • 2002
  • In this paper, a new method for reducing harmonic in input AC line currents of converter presents, which is the multi-pulse converter circuit without the input transformer. This system can reduce the harmonic like conventional 12-pulse converter. Both the bridge circuits are controlled with the shifted firing angle and connected 2 tap inter-phase reactor. Using 2 tap changing on inter-phase reactor, the input current is controlled with the different two values in order to make the input current waveform 12 pulses.

  • PDF

디지탈 신호처리 기법을 이용한 맥동연소기의 소음원 규명에 관한 연구 (Noise Source Identification of a Pulse Combustion Burner Using Digital Signal Processing Techniques)

  • 김도원;조정길;이관수;오재응
    • 설비공학논문집
    • /
    • 제3권2호
    • /
    • pp.103-113
    • /
    • 1991
  • This paper presents a method for estimating the noise source contribution of a pulse combustion burner in a multiple input system where the input sources may be coherent each other. By coherence function method, it is found that the biggest part of the noise source in the pulse combustion burner is generated by the part of the combustion chamber. This analysis is modeled as three input / single output system because the noise generating mechanism of the pulse combustion burner is very complicated. The coherence function method is proved to be useful tool for the identification of noise source. The overall levels of the radiated source pressure by coherence function method are compared with those measured and calculated by the frequency response function approach. The experimental results have shown a good agreement with the results calculated by the coherence function method when the input sources are coherent strongly each other. The estimation of shield effect by FRF method indicates that significant reduction can be achieved in sound radiation if only transmission path generated by the part of combustion chamber is acoustically shield.

  • PDF

상간리액터의 2-4? 변환 방식에 의한 콘버어터 입력 전류의 고조파 저감에 관한 연구 (A new Method for Reducing Harmonics in Input AC Line Currents of Converter by 2-4 Switching taps on Interphase Reactor)

  • 유철로;이공희;이성룡
    • 대한전기학회논문지
    • /
    • 제37권1호
    • /
    • pp.25-32
    • /
    • 1988
  • In this paper, a new method for reducing harmonics in input AC line currents of converter is presented, which is due mainly to the equipment of 2-4 switching taps on interphase reactor. When this method is applicable to conventional 12 pulse converter, the 24 pulse converter, the 24 pulse or 48 pulse converter is controlled by firing angles. The former is performe in 2 tap method when less than 15 degrees, and the letter in 4tap method when more than 15 degrees. Therefore, the proposed method has the advantages of reducing harmonics in full range of control angle and comparison with the conventional 3 tap method. We proved the validity of that theoretically and experimentally.

  • PDF

극성가변 AC 펄스 MIG용접기를 이용한 아크 브레이징 (The Arc Brazing by Variable Polarity AC Pulse MIG Welding Machine)

  • 조상명;공현상
    • Journal of Welding and Joining
    • /
    • 제21권4호
    • /
    • pp.56-62
    • /
    • 2003
  • MIG brazing is used for many parts without melting base metal because of high productivity. Pulsed MIG brazing can be used to further reduce heat input and to improve the process stability. However, a significant amount of zinc in galvanized sheet steel is burned off in the area of brazes. Therefore, the brazing method to reduce the heat input is needed. In the brazing for galvanized sheet steel, variable polarity AC pulse MIG arc brazing can be applied to more decrease the heat input by setting EN-ratio adequately. In this research, we studied for the variable polarity AC pulse MIG arc brazing to decrease the heat input by using ERCuSi-A wire. As the result of increasing EN-ratio, melting ratio of base metal and burning off of zinc were reduced in galvanized sheet steel.

HVDC용 12-펄스 위상제어정류기의 새로운 게이트 펄스 발생 기법 (A New Gate Pulse Generating Method of 12-Pulse Phase Controlled Rectifier for HVDC)

  • 안종보;김국헌;이종무;이기도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.139-141
    • /
    • 2000
  • High voltage direct current(HVDC) transmission system uses the phase controlled rectifier triggered by means of IPC(individual phase control) or EPC(equidistant pulse control). Most HVDC system has adopted EPC method that can solve the harmonic instability problem of IPC method in weak power system. But EPC has inherent indirect synchronizing problem requiring the closed loop control. This paper presents the new gate pulse generating method for 12-pulse HVDC converter, which combines IPC with EPC. Simulation and test results are presented. The basic concept is that it generates the gating pulse for 12-pulse converter by synthesizing the internal phase reference using the frequency and phase information of a sin91e phase voltage. To ensure the reliability of the external phase input, Potential transformer that detects the phase voltage has redundancy. Using fault detecting algorithm the healthy input is always guaranteed. And the frequency compensation function was reinforced.

  • PDF

A Wide Input Range Active Multi-pulse Rectifier For Utility Interface Of Power Electronic Converters

  • Hahn Jaehong;Enjeti Prasad N.;Park In-Gyu
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.512-517
    • /
    • 2001
  • In this paper, a wide input range active multi-pulse rectifier for utility interface of power electronic converters is proposed. The scheme combines multi-pulse method using a V-A transformer and boost rectifier modules. A current control scheme for the rectifier modules is proposed to achieve sinusoidal line currents in the utility input over a wide input range of input voltage and output load conditions. A design example is included for a 208V to 460V input, $700V_{dc}$ do 10kW output rectifier system. Simulation results are shown.

  • PDF

Research on Grid Side Power Factor of Unity Compensation Method for Matrix Converters

  • Xia, Yihui;Zhang, Xiaofeng;Ye, Zhihao;Qiao, Mingzhong
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1380-1392
    • /
    • 2019
  • Input filters are very important to matrix converters (MCs). They are used to improve grid side current waveform quality and to reduce the input voltage distortion supplied to the grid side. Due to the effects of the input filter and the output power, the grid side power factor (PF) is not at unity when the input power factor angle is zero. In this paper, the displacement angle between the grid side phase current and the phase voltage affected by the input filter parameters and output power is analyzed. Based on this, a new grid side PF unity compensation method implemented in the indirect space vector pulse width modulation (ISVPWM) method is presented, which has a larger compensation angle than the traditional compensation method, showing a higher grid side PF at unity in a wide output power range. Simulation and experimental results verify that the analysis of the displacement angle between the grid side phase current and the phase voltage affected by the input filter and output power is right and that the proposed compensation method has a better grid side PF at unity.