• Title/Summary/Keyword: pulse height

Search Result 193, Processing Time 0.026 seconds

Study on Reflux According to Pyloroplasty and Path of Gastric Graft in Esophageal Reconstruction (식도 재건 수술에 있어 유문 성형과 식도 접합 경로에 따른 음식물 역류 현상 연구)

  • Choi, Sung-Hoon;Sung, Jae-Yong;Lee, Jae-Ik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.697-703
    • /
    • 2012
  • In this study, duodenogastric reflux has been investigated according to pyloroplasty and the path of the gastric tube in esophageal reconstruction. The paths of the gastric graft (front and rear paths) were determined from the CT images of ten patients, and the gastric tube model was constructed using an RP technique. The gastric tubes were connected to the pylorus models with and without pyloroplasty. Various distal pressures and pulse widths were applied, and the volume and maximum height of the refluxate were measured. The results show that the volume and height of the refluxate increase with the distal pressure, and the front path leads to a smaller volume and lesser height of the refluxate than the rear path if pyloroplasty is conduced. The volume of the refluxate is markedly increased by a larger pulse width, but its effect on the maximum height depends on whether pyloroplasty is conducted.

Analysis of Pulse Wave Parameters According to Aging for Arteriosclerosis Evaluation (동맥경화 평가를 위한 연령별 맥파 주요인자 분석)

  • Lee, Na-Ra;Lee, Seung-Wook;Kim, Soo-Byeong;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.79-89
    • /
    • 2011
  • Objectives : The aim of this study is to propose the W area of pulse (AW) as a new index which can confirm the arteriosclerosis by analyzing parameters of 5-level pressure pulse waveform measurement system for normotensive group according to aging. Methods : We measured radial pulse waveforms of normotensive group (20 to 60 years old) using 3-dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea). And then we analyzed various parameters for sclerosis of the arteries such as Height (h1, h2, h3, h4, h5), Time (t1, t2, t3, t4, t5), AW, AW rate, Total area of pulse (At) and Augmentation Index (AIx). Results : As a result of analyzing parameters according to the aging, h2, h3, AS (systolic area rate to AT), AIx and AW were increased but t2/t, t3/t, t5/t and AD (diastolic area rate to AT) were decreased. Conclusions : We checked blood vessel conditions for normotensive group according to aging and confirmed various parameters. Also, we found that AW was analogous to AIx which has been used for diagnosing arteriosclerosis. Furthermore, we confirmed the usefulness of AW as a new parameter for checking vessel condition and characteristic compared with the AIx.

Differential non-linearity correction for successive approximation ADC

  • Yamada, Hikaru
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10a
    • /
    • pp.847-850
    • /
    • 1987
  • In this paper a new method to correct the differential non-linearity(D NL) error for a successive approximation is proposed. The DNL of ADC is very important characteristic in the field of radiation pulse height analysis or measurement of probability density function. The results of computer simulations are shown to demonstrate the feasibility of the proposed correction method.

  • PDF

Electroplating of Copper Using Pulse-Reverse Electroplating Method for SiP Via Filling (펄스-역펄스 전착법을 이용한 SiP용 via의 구리 충진에 관한 연구)

  • Bae J. S.;Chang G H.;Lee J. H.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.2 s.35
    • /
    • pp.129-134
    • /
    • 2005
  • Electroplating copper is the important role in formation of 3D stacking interconnection in SiP (System in Package). The I-V characteristics curves are investigated at different electrolyte conditions. Inhibitor and accelerator are used simultaneously to investigate the effects of additives. Three different sizes of via are tested. All via were prepared with RIE (reactive ion etching) method. Via's diameter are 50, 75, $100{\mu}m$ and the height is $100{\mu}m$. Inside via, Ta was deposited for diffusion barrier and Cu was deposited fer seed layer using magnetron sputtering method. DC, pulse and pulse revere current are used in this study. With DC, via cannot be filled without defects. Pulse plating can improve the filling patterns however it cannot completely filled copper without defects. Via was filled completely without defects using pulse-reverse electroplating method.

  • PDF

Multi-channel analyzer based on a novel pulse fitting analysis method

  • Wang, Qingshan;Zhang, Xiongjie;Meng, Xiangting;Wang, Bao;Wang, Dongyang;Zhou, Pengfei;Wang, Renbo;Tang, Bin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2023-2030
    • /
    • 2022
  • A novel pulse fitting analysis (PFA) method is presented for the acquisition of nuclear spectra. The charging process of the feedback capacitor in the resistive feedback charge-sensitive preamplifier is equivalent to the impulsive pulse, and its impulse response function (IRF) can be obtained by non-linear fitting of the falling edge of the nuclear pulse. The integral of the IRF excluding the baseline represents the energy deposition of the particles in the detector. In addition, since the non-linear fitting process in PFA method is difficult to achieve in the conventional architecture of spectroscopy system, a new multi-channel analyzer (MCA) based on Zynq SoC is proposed, which transmits all the data of nuclear pulses from the programmable logic (PL) to the processing system (PS) by high-speed AXI-Stream in order to implement PFA method with precision. The linearity of new MCA has been tested. The spectrum of 137Cs was obtained using LaBr3(Ce) scintillator detector, and was compared with commercial MCA by ORTEC. The results of tests indicate that the MCA based on PFA method has the same performance as the commercial MCA based on pulse height analysis (PHA) method and excellent linearity for γ-rays with different energies, which infers that PFA method is an effective and promising method for the acquisition of spectra. Furthermore, it provides a new solution for nuclear pulse processing algorithms involving regression and iterative processes.

Shaking table tests on the seismic response of slopes to near-fault ground motion

  • Zhu, Chongqiang;Cheng, Hualin;Bao, Yangjuan;Chen, Zhiyi;Huang, Yu
    • Geomechanics and Engineering
    • /
    • v.29 no.2
    • /
    • pp.133-143
    • /
    • 2022
  • The catastrophic earthquake-induced failure of slopes concentrically distributed at near-fault area, which indicated the special features of near-fault ground motions, i.e. horizontal pulse-like motion and large vertical component, should have great effect on these geo-disasters. We performed shaking table tests to investigate the effect of both horizontal pulse-like motion and vertical component on dynamic response of slope. Both unidirectional (i.e., horizontal or vertical motions) and bidirectional (i.e., horizontal and vertical components) motions are applied to soft rock slope model, and acceleration at different locations is reordered. The results show that the horizontal acceleration amplification factor (AAF) increases with height. Moreover, the horizontal AAF under unidirectional horizontal pulse-like excitations is larger than that subject to ordinary motion. The vertical AAF does not show an elevation amplification effect. The seismic response of slope under different bidirectional excitations is also different: (1) The horizontal AAF is roughly constant under horizontal pulse-like excitations with and without vertical waves, but (2) the horizontal AAF under ordinary bidirectional ground motions is larger than that under unidirectional ordinary motion. Above phenomena indicate that vertical component has limited effect on seismic response when the horizontal component is pulse-like ground motion, but it can greatly enhance seismic response of slope under ordinary horizontal motion. Moreover, the vertical AAF is enhanced by horizontal motion in both horizontal pulse-like and ordinary motion. Thence, we should pay enough attention to vertical ground motion, especially its horizontal component is ordinary ground motion.

A Study on the Characteristic of the $^6Li$ Neutron Spectrometer ($^6Li$ 중성자분광계 특성 연구)

  • Choe, Seong-Ho;Kang, Sam-Woo;Lee, Kwang-Pill;Lee, Kyung-Ju;Hwang, Sun-Tae
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.57-61
    • /
    • 1992
  • For the neutron spectrum measurement, $^6Li$ neutron spectrometer system is installed. The characteristic of the $^6Li$ detector are investigated using a $^{137}Cs$ and $^{207}Bi$ point source, and the neutron capture peaks and the pulse height spectrum using an $^{214}Am-Be$ neutron source are measured. Furthermore, the pulse height spectrum for the irradiation time variation from the (214)^Am-Be neutron source, and for the distance variation between detector and source, and the threshold variation of discriminator are measured.

  • PDF

An Experimental Study on the Correlationship Between Highrised Safetyguard and Workers' Safety (안전난간유형에 따른 작업자 안전의 상관관계에 대한 실험적 연구)

  • 손기상
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.80-84
    • /
    • 2001
  • Work stress and health are very important factors related to workers' condition and work safety, Author has conducted a couple of tests to check up three people's pulses before they work during their work for three types of safety guard in construction site. Work type, age, weight, sex experience year, ambient temperature n recorded as variables in this study. These are checked and asked by the author directly, before their pulse check Also, workers' Pulses were measured at height H-0 and H-9.0m to understand psychological the degree of psychological nervousness degree. POLAR protrainer NVTM HRM system(wrist recorder and sensor) was used for the site test. There are three(3) different types of construction safety guard which have been used for, this study. They are usually or frequently used and found in the site. Four different ranges of age groups(20's, 30's 40's, 50's) carpenters are assisted to the test sites with wearing pulse recorder and sensor respectively. All three types of safety guards have the same height 90㎝ even though they are different types. On top of five(5) stories tublar framed scaffolding is fabricated, similar to the one in site, where those safety guards are installed. The older(=more experienced) the workers are the more stable they are. it is shown. Also, It is verified the visually uncomfortable rail type can cause workers to psychologically be unstable.

  • PDF

Effects of the Probody Massage on the Physical Characteristics, Gross Motor Function and ROM in Youth with Cerebral Palsy : Case study (프로바디마사지가 뇌병변 장애우의 신체적 특성과 대동작 기능 및 관절 가동범위에 미치는 영향 : 사례연구)

  • Kim, Eui-Suk;Yang, Jeong-Ok;Lee, Joong-Sook
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.4
    • /
    • pp.453-463
    • /
    • 2015
  • Objective : The purpose of this study was to investigate the effects of the Probody Massage Program on the physical characteristics, gross motor function and ROM (Range Of Motion) of children with cerebral palsy. Method : The subjects of this study were two children who have been diagnosed with first grade cerebral palsy that utilized T development support center located in B Metropolitan city for 8 weeks, twice a week, to carry out the Probody Massage Program for 30 minutes. Physiological reactions (height, weight, BMI, blood pressure (an index of inflammation), pulse rate) and large operating functions (sitting, crawling and the joints' range of motion as an angle of the shoulders' upper limb articulation) were measured pretest, after 4 weeks, and after 8 weeks. Results : The Probody Massage Program showed positive changes in physical characteristics (blood pressure, sitting, and crawling), gross motor function (upper limb shoulder movement), joint range of motion, height, body weight, metabolic activation and blood circulation of children with cerebral palsy. Conclusion : We believe making a practical impact on the growth and development, functional recovery of daily life, and improvement of quality of life of children with cerebral palsy by utilizing Probody Massage Program improves blood pressure (an index of inflammation), pulse, sitting, crawling, and the joints' range of motion as an angle of the shoulder joints' upper limb movement of children with cerebral palsy.

Development of Blood Pressure Estimation Methods Using The PPG and ECG Sensors (PPG 및 ECG 센서를 이용한 혈압추정 기법 개발)

  • Park, Hyun-Moon;Lee, Jung-Chul;Hwang, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1257-1264
    • /
    • 2019
  • The traditional cuff-based method for BP(Blood Pressure) measurement is not suitable for continuous real-time BP measurement techniques. For this reason, the previous studies estimated various blood pressures by fusion with the electrocardiography (ECG) and photoplethysmogram (PPG) sensor signals. However, conventional techniques based on PPG bio-sensing measurement face many challenging issues such as noisy supply fluctuation, small pulsation, and drifting non-pulsatile. This paper proposed a novel BP estimation methods using PPG and ECG sensors, which can be derived from the relationship between PPG and ECG using PTT(Pulse Transit Time) and PWV(Pulse Wave Velocity). Unlike conventional height ratio features, which are extracted on the basis of the peaks in the PPG and ECG waveform. The proposed method can be reliably obtained even if there are missing peaks among the sensed PPG signal. The increased reliability comes from periodical estimation of the peak-to-peak interval time using ECG and PPG. After 250,000 times trials of the blood pressure measurement, the proposed estimation technique was verified with the accuracy of ±28.5% error, compared to a commercialized BP device.