• Title/Summary/Keyword: pulse evaluation

Search Result 499, Processing Time 0.031 seconds

Suggestion for Objective Evaluation of Comparative Pulse Diagnosis

  • Jun-Sang Yu
    • Journal of Pharmacopuncture
    • /
    • v.27 no.1
    • /
    • pp.21-26
    • /
    • 2024
  • Objectives: Pulse is a method of Korean medicine diagnosis and is an important clue to detect the organs, nature, and progress of the disease. Pulse examination is included in the basic examination of Korean medicine doctors, but there is no standardized method for diagnosing pulse although the types and methods of the pulse taking are briefly described in the literature, making it difficult to spread the examination method. In this regard, I would like to propose an objective evaluation method. Methods: Although the importance of pulse examination and the method of pulse examination are known in the literature, it is difficult for undergraduate students or inexperienced Korean medicine doctors to access it, so in this paper a method of marking the size of the pulse power in the blank space for objective evaluation was devised and presented. Results: The size of the pulse power should be indicated using the 1-cell, 3-cell, or 5-cell method according to the left and right wrists and the cun, guan and chi on both sides. Conclusion: The method of pulse diagnosis is an important diagnostic method as a verification process for making a Korean medical diagnosis. The remaining Korean medicine diagnostic methods, including pulse diagnosis, also need to undergo objectification. It is believed that the objectification of these diagnostic methods will lead to an improvement in the treatment rate of Korean medicine.

Investigation of Logisitic Regression Equation of Vacuous Pulse and Replete Pulse for Efficacy Evaluation of Clip-type Pulsimeter by using Magnetic Hall Device (자성홀소자를 이용한 집게형 맥진기의 유효성 평가를 위한 허맥과 실맥 로지스틱 회귀식 탐색)

  • Yu, Jun-Sang;Chang, Sei-Jin;Sun, Seung-Ho;Hong, Yu-Sik;Lee, Sang-Suk
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.17 no.1
    • /
    • pp.63-76
    • /
    • 2013
  • The aims of this study are to investigate a logisitic regression equation of the vacuous pulse and the replete pulse for efficacy evaluation of clip-type pulsimeter by using magnetic Hall device. To evaluate the efficacy of clip-type pulsimeter by using magnetic Hall device as sensing the minute movement of a radial artery, one research clinical trial have been performed. The number of subject was 120, the clinical data of patients did treated with a normal statistical method. The systolic peak amplitude, the reflective peak amplitude and time, and the notch peak amplitude and time are analyzed major efficacy parameters to discern the vacuous pulse and the replete pulse. The equations included of five parameters such as systolic peak amplitude, the reflective peak amplitude and time, and the notch peak amplitude and notch amplitude time for determination of the vacuous pulse and the replete pulse were deducted by statistical logistic regression method. It suggests that the logistic regression equations are possible to develop the oriental algorithm for pulse diagnosis.

Crack Depth Evaluation of Concrete Structures using Ultrasonic Pulse Velocity method (초음파 속도법을 이용한 콘크리트 구조물의 균열깊이 측정)

  • 오병환;김광수;김세훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.659-662
    • /
    • 1999
  • Ultrasonic pulse velocity method is employed for evaluation of crack depth in concrete structures. Due to the heterogeneous nature of concrete and the indirect transmission arrangement for the transit time measurement through the surface-opening cracks in concrete structures, ultrasonic pulse velocity has so many variations as crack depths and transmission lengths vary. In this study, ultrasonic pulse velocity method is investigated to evaluate the surface-opening crack depth of concrete slabs, reinforced concrete slabs, reinforced concrete flexural members. the resent study gives a modified method for deminishing errors in transit time measurements and show limitations to the evaluation of crack depth in reinforced concrete structures.

  • PDF

Evaluation of Tunnel Lining Concrete Using Ultrasonic Pulse Velocity Method (초음파법을 이용한 무근콘크리트 터널라이닝의 품질평가)

  • 최홍식;이시우;신용석;오영석;오광진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.795-800
    • /
    • 2001
  • Two evaluation techniques of the tunnel lining concrete using ultra sonic velocity method are developed. Modified linear regression technique is proposed to enhance the corelation between the pulse velocity and the compressive strength of core specimens. And bivariate normal distribution is assumed to evaluate the quality of concrete as a terms of compressive strength. A simple corelation table between the pulse velocity and the compressive strength of core specimens are proposed.

  • PDF

Finite element modeling of laser ultrasonics nondestructive evaluation technique in ablation regime

  • Salman Shamsaei;Farhang Honarvar
    • Advances in Computational Design
    • /
    • v.8 no.3
    • /
    • pp.219-236
    • /
    • 2023
  • In this paper, finite element modeling of the laser ultrasonics (LU) process in ablation regime is of interest. The momentum resulting from the removal of material from the specimen surface by the laser beam radiation in ablation regime is modeled as a pressure pulse. To model this pressure pulse, two equations are required: one for the spatial distribution and one for the temporal distribution of the pulse. Previous researchers have proposed various equations for the spatial and temporal distributions of the pressure pulse in different laser applications. All available equations are examined and the best combination of the temporal and spatial distributions of the pressure pulse that provides the most accurate results is identified. This combination of temporal and spatial distributions has never been used for modeling laser ultrasonics before. Then by using this new model, the effects of variations in pulse duration and laser spot radius on the shape, amplitude, and frequency spectrum of ultrasonic waves are studied. Furthermore, the LU in thermoelastic regime is simulated by this model and compared with LU in ablation regime. The interaction of ultrasonic waves with a defect is also investigated in the LU process in ablation regime. Good agreement of the results obtained from the new finite element model and available experimental data confirms the accuracy of the proposed model.

The Study on Earlier Evaluation of Concrete Strength Using Ultra Sonic Velosity Method (초음파 시험에 의한 콘크리트의 조기 강도 판정에 관한 연구)

  • 김화중;이도헌;윤상천;박정민;최신호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.136-141
    • /
    • 1995
  • The early evaluation on strength of concrete is useful to achieve on quality control and improvement of properties of concrete. Especially, we could say that the confidence of construction is increased by the increase durability and safety building, due to early evaluation. In this study, was proposed to ultra-sonic pulse method as a early evaluation method for strength of concrete with main parameter, sush as W/C ratio and S/A ratio. The experiment results are summarized to follow as : $\circled1$ The ultra-sonic pulse was decreased as the increase of W/C ratio. $\circled2$ The maximum value for the ultra-sonic pulse velocity and compressive strength was presented in the case of 40% S/A ratio and these value was decreased as the change of S/A ratio over 40% $\circled1$ The relationship of the ultra-sonic pulse velocity and compressive strength on 28days according to the change of W/C and S/A ratio is to be: $F_{28} = -209193R^2 + 384417R - 1763441$(W/C Ratio) $F_{28} = 1726R^2 - 774R - 502 (S/A Ratio)

  • PDF

Development of WMTS Module Based Pulse Rate Period Detection and Human Sensibility Evaluation System (WMTS 무선통신 모듈을 이용한 맥파의 주기검출 및 감성평가 시스템 개발)

  • Lee, Hyun-Min;Kim, Dong-Jun;Jeon, Ki-Man;Son, Jae-Gi
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.811-817
    • /
    • 2013
  • In this study we present a system for pulse-rate period detection and human sensibility evaluation based on the wireless medical telemetry service (WMTS) used for transmission of data from medical telemetry devices to various medical facilities and services. We develop a medical-purpose specific WMTS communication module to transmit biometric signals. From the pulse rate variability(PRV) signal, we attempt to classify positive and negative emotional states based on analysis of the ratio of LF/HF in the frequency domain. We measure the data reception rate according to distance in order to test the performance of the WMTS module and analyze the effects on human sensibility evaluation.

A Study on the Statistical Distribution of Rebound Number and Ultrasonic Pulse Velocity in RC and PSC Concrete Structures (RC 및 PSC 콘크리트에서 반발도 및 초음파 속도의 변화에 대한 연구)

  • Sa, Min-Hyung;Yoon, Young-Geun;Lee, In-Bok;Woo, In-Sung;Oh, Tae Keun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.53-58
    • /
    • 2017
  • The rebound hammer test and the measurement of ultrasonic pulse velocity(UPV) have been widely used for the physical properties & condition evaluation of reinforced & prestressed concrete structures for a long time, but the acoustoelastic effects by the prestressing in the prestressed concrete structures on the rebound number and ultrasonic pulse velocity have not been studied clearly. Therefore, this study investigated the data distribution of the rebound numbers and ultrasonic pulse velocities in reinforced and prestressed concrete slabs of $3000{\times}3000mm$ with a thickness of 250 mm. Also, the Kolmogorov-Smirnov goodness-of-fit test was done in order to identify statistical consistency and reliability. The statistical analysis results show that the rebound number and ultrasonic pulse velocities increased about 1.9% and 2.5%, respectively when prestressing was applied. As expected, the UPV shows better statistical reliability and potential for in situ evaluation than the RB because the RB are more sensitive to testing posture, surface condition, temperature and humidity so on. The experimental data in this study can be used for the condition assessment of reinforced and prestressed concrete structures by the rebound number and ultrasonic pulse velocity.

A Study on the Direction of Developing a Simulator for Performance Evaluation of Pulse Wave Detectors Through a Review of the Development Status of Cardiovascular Simulators (심혈관계 시뮬레이터 개발 동향 분석을 통한 맥파검사용기기 성능평가 시뮬레이터 연구개발 방향 모색)

  • Lee, Ju-Yeon;Kim, Jaeyoung;Go, Dong-Hyun;Lee, Ji-Won;Lee, Tae-Hee;Park, Chang-Won;Lee, Su-Kyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.136-146
    • /
    • 2022
  • In this study, it is intended to provide basic data that can help develop a cardiovascular simulator for performance evaluation of pulse wave detectors by identifying the development status of domestic and overseas cardiovascular simulators. A total of 119 papers were selected by excluding duplicate literature, gray literature, and literature not related to a cardiovascular simulator. Based on the selected literature, the research trend of cardiovascular simulators was analyzed. As a result of analyzing the purpose of the study, most of the simulators were developed to evaluate the hemodynamic properties of artificial hearts and valves. In addition, it was used for simulation evaluation or hemodynamic studies such as pulse wave studies. As a result of analyzing configurations of the simulators, a heart most often consisted of only one left ventricle. For blood vessels, the Windkessel model was most often constructed using chambers and valves. In most studies, blood was reproduced by mixing glycerin and water to reproduce both density and viscosity. In addition, as a result of analysis from the perspective of medical device performance evaluation, simulators for evaluating artificial heart and artificial valves have been studied a lot, whereas simulators for blood pressure, pulse wave, and blood flow devices have been relatively insignificant. Based on the review results, we suggested considerations when developing a simulator for performance evaluations of a pulse wave detector.