• Title/Summary/Keyword: pulse distance

Search Result 310, Processing Time 0.028 seconds

Multipath Mitigation for Pulses Using Supervised Learning: Application to Distance Measuring Equipment

  • Kim, Euiho
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.5 no.4
    • /
    • pp.173-180
    • /
    • 2016
  • This paper presents a method to suppress multipath induced by pulses using supervised learning. In modern electronics, pulses have been used for various purposes such as communication or distance measurements. Like other signals, pulses also suffer from multipath. When a pulse and a multipath are overlapped, the original pulse shape is distorted. The distorted pulse could result in communication failures or distance measurement errors. However, a large number of samples available from a pulse can be used to effectively reject multipath by using a supervised learning method. This paper introduces how a supervised learning method can be applied to Distance Measuring Equipment. Simulation results show that multipath induced distance measuring error can be suppressed by 10 ~ 45 percent depending on the allowed pulse shape variation allowed in a standard.

A Study on the Pressure drop Variance of Pulse interval, injection distance in Pulse Air Jet Type Bag Filter (충격기류식 여과집진장치의 펄스간격 밀 분사거리에 따른 압력손실변화에 관한 기초 연구)

  • Seo, Jeong Min;Choe, Geum Chan;Park, Jeong Ho
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.223-232
    • /
    • 2004
  • The change of pressure drop according to the change in the inlet concentration, pulse interval, and injection distance of pulse air jet type bag filters, and the effect of venturi installation are as follows. The pressure drop with the range of 30 to $50mmH_2O$ varies according to the injection distance with 30, 50, 70, 90sec and the inlet concentration of venture built-in fabric filters. For the lower concentration of 0.5g/㎥ and 1g/㎥, the pressure $drop(\DeltaP)$ was stable 60 to 90minutes after operation. For the higher concentration of 3g/㎥, as $\DeltaP$ continues to go up, pulse interval should be set shorter than 30 seconds. The pressure drop with the injection distance of 1l0mm, when inlet dust concentration is 0.5g/㎥ or 1g/㎥, is 1.3 to 2 lower than with the injection distance of 50, 160, and 220mm, which means that the inflow amount of the secondary air by the instant acceleration is large. The injection distance of 2g/㎥ and 3g/㎥ has the similar pressure distribution. The higher inlet concentration is, the more important pulse interval is than injection distance. The pressure drop has proved to be larger when inlet concentration is lower and injection distance closer, on condition that the venturi is installed. The change in the pressure drop was smallest when injection distance was 50mm, followed by 220mm, 160mm, and 110mm.

The Effects of the Stimulation Intensity and Inter-Electrode Distance on the Parameters of the Measured Sensory Nerve Signal (전기자극의 강도와 측정전극의 간격이 감각신경신호의 파라미터에 미치는 영향 연구)

  • Lim, Kyeong Min;Song, Tongjin
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.234-241
    • /
    • 2014
  • This study was designed to investigate the effects of stimulation intensity and inter-electrode distance on the parameters of the measured sensory nerve signal. 30 healthy subjects participated in this study. Sensory nerve signals were elicited by four different pulse amplitudes, i.e., 3, 6, 9, 12 mA, with the pulse width fixed at $500{\mu}s$. The sensory nerve signals elicited by the four different pulse amplitudes were measured by four different inter-electrode distances (20, 30, 40, and 50 mm). We extracted four parameters (pulse amplitude, pulse width, pulse area, and latency time from stimulation) from the sensory nerve signals. The measured pulse amplitude and pulse width were increased when the measuring inter-electrode distance was increased while the stimulating pulse amplitude was fixed. The measured pulse amplitude was saturated with the stimulating pulse amplitudes of over 6 mA while measuring inter-electrode distance. Under the same condition, measured pulse width was increased, and sensory nerve signal was initiated early. Sensory nerve signals, specially those of pulse amplitude, were distorted by a differential amplification method that commonly measures the human body signal. The experimental results indicate that the differential amplification method is required to be replaced when measuring nerve signals. Our observations suggested that the hyperpolarization of the action potential of the sensory nerve signal for preventing distortion could be used to clarify the correlation between the parameters of the sensory nerve signals and quantification of sensations.

Experimental Study on Optimum Pulse Jet Cleaning Conditions of a Cartridge Filter System (카트리지 필터 여과집진기 충격기류시스템의 최적탈진조건에 관한 실험적 연구)

  • Piao, Cheng Xu;Ha, Hyun Chul;Kim, Sung Joon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.4
    • /
    • pp.542-553
    • /
    • 2015
  • Objectives: Many types of dust collector are used for industrial ventilation, with the most common types being the cylinder bag filter system, rectangular bag filter system and cylinder type cartridge filter system. The cylinder type cartridge bag filter, which has more filtering area than other types of bag filter, can increase the pulse time and extend the useful life of the filter. This can save operational costs and installation area. Materials: This study used cylinder type cartridge bag filter equipment and tested the impact of vibration level and filter pressure with different pulse jet cleaning conditions. The final, cleaning efficiency was calculated through input dust mass and cleaning dust mass Conclusions: Two optimum cleaning condition groups were found. The first condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.2 s pulse time with an H-10 type nozzle. The second condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.3 s pulse time with an H-10 type nozzle.

A Study on Deep Reinforcement Learning Framework for DME Pulse Design

  • Lee, Jungyeon;Kim, Euiho
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.2
    • /
    • pp.113-120
    • /
    • 2021
  • The Distance Measuring Equipment (DME) is a ground-based aircraft navigation system and is considered as an infrastructure that ensures resilient aircraft navigation capability during the event of a Global Navigation Satellite System (GNSS) outage. The main problem of DME as a GNSS back up is a poor positioning accuracy that often reaches over 100 m. In this paper, a novel approach of applying deep reinforcement learning to a DME pulse design is introduced to improve the DME distance measuring accuracy. This method is designed to develop multipath-resistant DME pulses that comply with current DME specifications. In the research, a Markov Decision Process (MDP) for DME pulse design is set using pulse shape requirements and a timing error. Based on the designed MDP, we created an Environment called PulseEnv, which allows the agent representing a DME pulse shape to explore continuous space using the Soft Actor Critical (SAC) reinforcement learning algorithm.

Effects of the Stand-off Distance on the Weld Strength in Magnetic Pulse Welding (전자기펄스용접에서 용접강도에 미치는 접합간격의 영향)

  • Kim, Sung-Wook;Chun, Chang-Keun;Kim, Sook-Hwan
    • Journal of Welding and Joining
    • /
    • v.26 no.6
    • /
    • pp.48-53
    • /
    • 2008
  • Although Magnetic Pulse Welding(MPW) is not a recently developed technique, it has gained the attention of the automotive industry. MPW has become an accepted welding process because it enables the joining of similar, and dissimilar materials, with a very short cycle time, without the need for filler metal and gases. In this study, the effect of the stand-off distance on the weld strength has been investigated. The compressive strength of the MPW joints was evaluated using UTM. The interface of weld, IMC composition and morpology were studied by SEM and EDS. It was concluded that the stand-off distance and the voltage are the main parameters influencing the strength of weld. In case of too high stand-off distance, it influenced harmful effect because of the resistance of deformation.

Theoretical Considerations on Combined Optical Distance Measurements Using a Femtosecond Pulse Laser

  • Joo, Ki-Nam;Kim, Seung-Woo
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.396-400
    • /
    • 2012
  • We introduce a combined technique and the mathematical description for distance measurements using a femtosecond pulse laser in a long range and a fine resolution. For distance measurements, the maximum measurable range can be extended by combining measurement results from several different methods while requiring relationships between the different measurement uncertainties and unambiguity ranges. This paper briefly explains why the uncertainty of a rough measurement technique (RMT) should be, at least, smaller than the half unambiguity range of a fine measurement technique (FMT) in order to combine a FMT with a RMT. Further discussions about the total measurement range, resolution, and uncertainty for various optical measurement techniques are also discussed.

Prediction of Off-line Type Pulse Air Jet Bag Filter Reflection Distance (간헐탈진형 충격기류식 여과집진장치의 여과포 반사거리 예측)

  • Jeong-Sam Son;Yong-Hyun Chung;Jeong-Min Suh
    • Journal of Environmental Science International
    • /
    • v.32 no.11
    • /
    • pp.801-809
    • /
    • 2023
  • The purpose of this study is to predict the reflection distance following to the pulsing pressure, total air supplying, filter bag size using numercial analysis techniques and use it as an efficient operation condition and economic data for off-line type pulse air jet bag filter. In this research, filtration area 6 m2 condition, calculate filter resistance coefficient for simulation through the main experiments using coke dust. Ansys fluent V19.0 apply to CFD simulation, and analysis pulsing characteristics about pulsing pressure, filtration velocity and nozzle diameter. The maximum reflecting distance of off-line type pulse air jet bag filter is 1,000 mm regardless of total air supplying at over the 42 L/m2 conditions, that indicates off-line type can extend filter bag length 1,000 mm than on-line type. In order to effective primary and secondary pulsing of off-line type pulse air jet bag filter, over the 5 bar of pulsing pressure and over the 42 L/m2 of total air supplying are needed.

Proposal for Pulse Diagnosis Positions (Chon-Kwan-Chuk) for Pulse Analyzer Based on Literature Review and Anthropometry (문헌고찰 및 실측에 근거한 맥진기 측정시 촌관척 정위에 대한 제안)

  • Kim, Hyun-Ho;Lee, Jeon;Kim, Ki-Wang;Kim, Jong-Yeol
    • The Journal of Korean Medicine
    • /
    • v.28 no.3 s.71
    • /
    • pp.13-22
    • /
    • 2007
  • Objectives : To obtain pulse information, oriental medical doctors usually use the three finger pulse diagnosis method. Although the diagnostic positions are very important, the exact positions are not known because of the uncertain conversion of measures of length (bun, chon, chuk) and misunderstanding of the related concepts of oriental medicine. In this study, we proposed relative positions for the detection of three pulses with a pulse analyzer. Methods : The proposal was made based mainly on several literature reviews, especially the original texts, and the examination of anthropometric characteristics of 78 individuals. Results : The Kwan is the spot where the radial pulse can be felt well near the eminent head of the radius at wrist, high bone. The position of Chon should be apart from Kwan by 6/10 distance between the high bone and wrist joint of each individual. Finally, the position of Chuk is apart from Kwan by 6.5/100 distance between the high bone and the elbow joint of each individual. Conclusions : Adapting those proposed positions for measuring three pulses can provide more consistent information to what an oriental doctor obtains than a pulse analyzer applied to other positions.

  • PDF