• Title/Summary/Keyword: pulse corona discharge

Search Result 82, Processing Time 0.025 seconds

Simultaneous Removal Characteristics of NOx, SOx from Combustion Gases using Pulse Corona induced Plasma Chemical Processing (PPCP에 의한 연소가스 중 NOx, SOx 동시제거 특성)

  • Park, Jae-Yoon;Koh, Yong-Sul;Jung, Jang-Gun;Kim, Jung-Dal
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.211-216
    • /
    • 2000
  • In this paper, experimental investigations were carried out to remove NOx, SOx simultaneously from a simulated combustion flue gas [$NO(0.02%)-SO_2(0.08%)-CO_2-Air-N_2$] by using a pulse corona induced plasma chemical processing. Discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was $2.5{\ell}/min$ for bubbling aqueous NaOH solution. Ammonia gas(l4.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio(MR) was determined based on [$NH_3$] and [$NO+SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration. but SOx removal rate was not significantly affected by initial concentration. The NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF

Air/Quartz Dielectric Double Barrier Pulse Discharge (공기/석영관(空氣/石英管) 복합유전체(複合誘電體)장벽층(障壁層)의 고주파(高周波) 펄스 방전(放電) 특성(特性))

  • Lee, Eung-Gwan;Woo, Jung-Uk;Chung, Suk-Hwan;Lee, Dong-Hoon;Moon, Jae-Duk
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1556-1558
    • /
    • 1994
  • An air/quartz dielectric double barrier pulse discharge has been investigated to develop a novel si lent type ozone generator. It is found that there are very active pulsed coronas occurred in the airgap which are very useful for ozone generation. And, the corona onset voltage of the airgap of the air/quartz double barrier was enfluenced greatly by the airgap of the air/quartz dielectric double barrier, and depended greatly upon the airgap ranged of $0.0{\sim}3.0mm$ and by the quartz tube thickness ranged of $1.75{\sim}2.25mm$.

  • PDF

A Study on Discharge Characteristics in Flowing Gas at High Voltage Nozzle (고전압(高電壓) Nozzle 에서 유출(流出)하는 기체(氣體)의 방전특성(放電特性)에 관한 연구(硏究))

  • Song, Hyun-Jig;Kim, Sang-Ku;Jeun, Young-Ju;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.563-565
    • /
    • 1993
  • This paper describes ozone concentration and discharge characteristics in flowing $O_2$ with variation of Re at high voltage nozzle(HVN). HVN type ozonizer is equipped with ten nozzle. The important conclusions obtained from this paper are as follows. For constant pulse width(Pw) and pulse frequency(Pf) the more Re increases, the higher corona onset voltage(Vc) rise. Vc is inversely proportional to Pw and Pf. Ozone concentration($O_{3con}$) increases with less Re for constant Pw and Pf. $O_{3con}$ increases with less Pw. $O_{3con}$ is proportional to Pf.

  • PDF

On Line Partial Discharge Measurement Method for Transformer (온라인 변압기 부분방전 측정기법)

  • Kweon, Dong-Jin;Choi, In-Hyuk;Song, Il-Keun;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.38-42
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

Bidirectional pulse generator for removal of flue gas (배기가스 처리용 양방향 펄스 전원)

  • 박정호;고광철;강형부
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.233-236
    • /
    • 1997
  • An investigation has been made of the various plasma chemistry reactions that occur in the corona discharge of an electrostatic precipitator operating in a typical flue gas. As the results of investigation, sulphur dioxide is removed principally by reactions with OH radicals to produce sulphuric acid, while nitrogen oxides are removed principally by reduction via the N radical to molecular nitrogen. If electrostatic precipitator\ulcorner used for flue gases are operated with positive voltages instead of negative dc voltages, there are significant reductions in the emission of the undesirable gases SO$_2$, NO, and NO$_2$. Thus, in this paper we design the bidirectional pulse generator for removal of flue gas, where the pulse width is more than 50[nsec] and the maximum output voltage is more than 100[kVl.

  • PDF

The Plasma Chemistry and Particle Growth in the Low Temperature Plasma Reactor for removal of NOx (NOx 제거용 저온 플라즈마 반응기에서의 플라즈마 화학 및 입자 성장)

  • Kim, Dong-Joo;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.331-341
    • /
    • 1999
  • We analyzed theoretically the removal efficiency and the particle growth inside the pulse corona discharge reactor to remove $NO_x$ and investigated the effects of process variables such as the NO and $NH_3$ input concentrations. Most of NO is converted into $NO_2$ and $HNO_3$ and the $HNO_3$ reacts with $NH_3$ to form the $NH_4NO_3$ particles. About 6.4% of NO is converted into $HNO_2$ which form the $NH_4NO_2$ particles by reaction with $NH_3$. Some of $NO_2$ follows the reaction pathway to form $NO_3$ and $N_2O_5$. The amount of particles formed inside the reactor is basically determined by the input $NH_3$ concentration. The ratio of NO to $NH_3$ affects the reactor length for particle formation significantly. The higher the input concentrations of NO and $NH_3$ are, the faster the particles grow.

  • PDF

A Study on Improvement of the Performance of Pulsed AC Ion Bar (1) (바 형태 정전기제거장치의 정전기제거성능 향상을 위한 연구 (1))

  • Lee, Dong Hoon;Choi, Dong Soo;Jung, Yong Chul;Kim, Sang Min
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.34-38
    • /
    • 2014
  • In Display such as LCD, LED, and AMOLED or semiconductor related industries are required to have static ionizer in order to produce reliable goods since the ionizer can create balanced ion that is delivered to producing goods to minimize electrical damages when manufacturing. However, the most general type of ionization is called, "Corona Discharge" that has a slight chances to generate unequal and unstable amount of each +/- ion to the target object. Then, the ionization performance will drastically decrease and end up with quality deterioration problem. In this research, our objective to resolve the current issue via applying "Coupling Condenser" on each counter electrodes of Corona discharging type ionizer. The result is that the ion balance was maintained the satisfied range that is within +/-100V when we changed the duty ratio of the High Voltage of Pulse AC about 40 ~ 70%. In addition, when levelling the High Voltage of Pulse AC, the ion balance holds the range within +20 ~ 0V. Even though we have tested the same experiment for a year, we have seen the range changes roughly ${\pm}50V$.

A Study on the Partial Discharge Location Method using 2 Sensors (2개 센서를 이용한 부분방전 위치추정 기법 연구)

  • Kim, Jeong-Tae;Kim, Dong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.251-256
    • /
    • 2012
  • This study deals with the location of partial discharges(PDs) for power cables and GIS using 2 PD sensors and long coaxial signal cables. Throughout the experiments by use of simulated PD pulses and corona discharges in the power cable system, it is found out that the impedance matching between the coaxial signal cable and the measuring equipment should be done for good S/N ratio and the on-site measurement using more than 100m-long coaxial signal cable is possible. In addition, new PD location algorithm with the polarities of PD pulses and the arrival time difference between two pulses was proposed and was proved through the partial discharge experiments for the cable joint defect and artificial void defect.

The Design of a Planar Patch Sensor for Partial Discharge Diagnosis in 6.6 kV Rotating Machine Stator Windings (6.6 kV 회전기 고정자 권선에서 부분방전 신호 검출을 위한 평면 패치 센서 설계)

  • Lim, Kwang-Jin;Park, Noh-Joon;Kim, Hee-Dong;Ju, Young-Ho;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.5
    • /
    • pp.481-485
    • /
    • 2008
  • In stator windings of 6.6 kV rotating machine, corona discharge, surface discharge and internal discharge are caused mainly by internal voids and insulation degradation. Also, if partial discharge occurs in inner-part of stator windings, it will be happened electromagnetic pulses at wide frequency range. In case of discharge spark, electromagnetic pulse generated from discharge source, and we can detect it by using various RF resonators as an EM sensor. In order to detect these kind of electromagnetic sources, we have designed and fabricated planar patch sensor using CST MWS simulation, and also PD signals from artificial defected cable were measured by our proposed sensor. Furthermore, HFCT was used as a reference sensor and compared with our proposed new planar patch sensor.