• 제목/요약/키워드: pulse corona discharge

검색결과 82건 처리시간 0.026초

저온 플라즈마 공정을 이용한 상용설비의 배연가스 처리 기술개발 (Technical Development of Flue Gas Control at Commercial Plant Using the Non-thermal Plasma Process)

  • 유정석;백민수;김태희;김정일;김유석;최석호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.939-944
    • /
    • 2001
  • For the application of simultaneous $DeSO_{2}\;&\;DeNO_{x}$ equipment using non-thermal plasma process to the industrial and power plants, the many types of plasma device and process were studied. The e-beam and pulsed plasma corona discharge process are outstanding for the study to apply commercial large-scale plant from among these. In this paper, non-thermal plasma of technical trends and the characteristics of system developed by Doosan heavy industries & construction Co., Ltd. are explained. We have researched pulsed plasma corona discharge process since 1994. At the basis of reasonable results for the pilot plant, we constructed the demonstration plant at a domestic coal-fired power plant in 1999, as the previous step for commercial use. In near future, enough information about designs and costs of commercial-size system will be obtained.

  • PDF

컴퓨터 시스템에 의한 대기압하(大氣壓下)에서 액체질소($LN_2$)의 방전특성측정(放電特性測定) (Measurement of the discharge characteristics of liquid nitrogen at atmospheric pressure by personal computer system)

  • 주재현;이영근;김상구;전영주;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1530-1532
    • /
    • 1994
  • This paper describes the discharge characteristics of liquid nitrogen for plane-plane, needle-plane electrode at variation of gap spacing at atmospheric pressure. The important results obtained from this study are as follows. (1) Breakdown voltage of $LN_2$ for needle-plane electrode is higher than that of for plane-plane electrode and discharge duration tine is longer with increase of gap spacing at atmospheric pressure. (2) The formation of bubbles by evaporation is observed in spite of non-applying source at atmospheric pressure and the creation of corona confirmed for plane-plane electrode results from the bubbles. (3) The applied voltage-discharge magnitude( V-Q) characteristics of $LN_2$ showed hysteresis and the discharge magnitude decreasing and corona voltage increasing proportional to the pulse per second at atmospheric pressure.

  • PDF

펄스전원을 이용한 수중플라즈마 방전에 관한 연구 (A Study on ther Water Plasma Chemical Process Discharge by Pulse Power Supply)

  • 신완호;홍원석;유효열;박선순;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2179-2181
    • /
    • 2005
  • An experimental study on the water plasma characteristics of removal efficiency for organic contaminants in dye waste water has been investigated. In this study, dielectric barrier discharging electrodes with round shape have disposed cross each other in reactor, and pulse power was supplied to between each electrodes. Its output pulse voltage range is from 0[V] to 30[kV] and output frequency range is from 100[Hz] to 2[kHz]. Using proposed system, High frequency discharge is tested in the mixed Tone(air and water) and the space distribution of streamer corona plasma is observed. In spite of the increasement of voltage and frequency, the proposed system have a stable operation characteristics. It is verified by the experimental results.

  • PDF

부분방전 펄스특성을 이용한 TF Map에 대한 고찰 (Considerations on the TF Map using Partial Discharge Pulse Characteristics)

  • 김정태;김남준;장용무;김지홍;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2126-2128
    • /
    • 2005
  • In this paper, it was investigated the applicability of TF analysis for the discrimination of air corona in on-site PD measurement. For the purpose, single and multiple discharges combined with oil discharges and air corona were generated and measured by use of artificial models and HFPD pulse detector. Through the TF analysis, data clusters could be classified each other in the TF Map, even in the case of multiple discharges. Therefore, it is known that TF analysis could be applied for the improvement of on-site PD measurement.

  • PDF

코로나 카메라를 이용한 불량애자 검출사례 분석 (Analysis on the Degradation of Insulators using Corona Camera)

  • 김호수;김필환;유영각;구경완;김효진;김대식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.132-134
    • /
    • 2003
  • Insulator that is used in electric power equipment superannuation and being damaged disorder can. Such as defected insulator has repair or change must because defective influence in electrical equipment. There are many method developed for detecting the defected insulators, analyzed various test of devide voltage, electric field, ultrasonic and discharge pulse. But methods of detecting ultrasonic of discharge, electric field or leakage current could not application in the field, In this paper, we compare the advantage and the limitation of the method to detect defected insulator, and wish proposed using corona camera.

  • PDF

회전기 고정자 권선의 부분방전 진단을 위한 평면 Patch Sensor 설계 (The Design of a patch Sensor for Partial Discharge diagnosis in Rotating Machine Stator Windings)

  • 양상현;임광진;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.97-98
    • /
    • 2008
  • In 6.6kV Rotary Machine Stator Windings, Corona Discharge, Discharge at Conductor Surface, Slot Discharge and Endwinding Discharge is happended by electronic degradation. Also, if Partial Discharge cause in inner-part of Rotary Machine Stator Windings, it will be happended voltage and current pulse. In case of discharge spark, RF electromagnetic wave, which transmits at discharge position, can happen. To detect this kind of RF electromagnetic wave efficiently, we have designed Planar Antenna Sensor with the CST MWS simulation program. Also we have confined the application possibility, which can analyzes the partial discharge in Rotary Machine Stator Windings. In the Future, sample of planar antenna sensor will be able to compare with the data of simulation by CST MWS program.

  • PDF

6.6kV 회전기 고정자 권선에서 부분방전 진단을 위한 평판 안테나 센서 설계 (The Design of a Planar Antenna Sensor for Partial Discharge diagnosis in 6.6kV Rotary Machine Stator Windings)

  • 임광진;키아우소륀;신동훈;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.222-223
    • /
    • 2007
  • In 6.6kV Rotary Machine Stator Windings, Corona Discharge, Discharge at Conductor Surface, Slot Discharge and Endwinding Discharge is happended by electronic degradation. Also, if Partial Discharge cause in inner-part of Rotary Machine Stator Windings, it will be happended voltage and current pulse. In case of discharge spark, RF electromagnetic wave, which tranmits at discharge position, can happen. To detect this kind of RF electromagnetic wave efficiently, we have designed Planar Antenna Sensor with the CST MWS simulation program. Also we have confined the application possibility, which can analize the partial discharge in Rotary Machine Stator Windings. In the Future, sample of planar antenna sensor will be able to compare with the data of simulation by CST MWS program.

  • PDF

PA Map(Pulse Analysis Map)을 이용한 새로운 부분방전 패턴인식에 관한 연구 (A Study on the New Partial Discharge Pattern Analysis System used by PA Map (Pulse Analysis Map))

  • 김지홍;김정태;김진기;구자윤
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1092-1098
    • /
    • 2007
  • Since one decade, the detection of HFPD (High frequency Partial Discharge) has been proposed as one of the effective method for the diagnosis of the power component under service in power grids. As a tool for HFPD detection, Metal Foil sensor based on the embedded technology has been commercialized for mainly power cable due to its advantages. Recently, for the on-site noise discrimination, several PA (Pulse analysis) methods have been reported and the related software, such as Neural Network and Fuzzy, have been proposed to separate the PD (Partial Discharge) signals from the noises since their wave shapes are completely different from each other. On the other hand, the relevant fundamental investigation has not yet clearly made while it is reported that the effectiveness of the current methods based on PA is dependant on the types of sensors. Moreover, regarding the identification of the vital defects introducible into the Power Cable, the direct identification of the nature of defects from the PD signals through Metal Foil coupler has not yet been realized. As a trial for solving above shortcomings, different types of software have been proposed and employed without any convincing probability of identification. In this regards, our novel algorithm 'PA Map' based on the pulse analysis is suggested to identify directly the defects inside the power cable from the HFPD signals which is output of the HFCT and metal foil sensors. This method enables to discriminate the noise and then to make the data analysis related to the PD signals. For the purpose, the HFPD detection and PA (Pulse Analysis) system have been developed and then the effect of noise discrimination has been investigated by use of the artificial defects using real scale mockup. Throughout these works, our system is proved to be capable of separating the small void discharges among the very large noises such as big air corona and ground floating discharges at the on-site as well as of identifying the concerned defects.

Novel Compact Current Type Pulse Power Generator

  • Min, B.D.;Kim, J.H.;Pavlov, E.;Yoo, D.W.;Rim, G.H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.529-531
    • /
    • 2005
  • This paper proposes a compact pulse generator fur NOx removal application for diesel automotive. The rising time is important factor to increase NOx removal efficiency in pulsed corona discharge method. Manufacturing cost and compactness of the pulse power generator should be satisfied for automotive application. The proposed pulse power uses a low voltage thyristor, a pulse transformer with the function of saturated magnetic switch, and series connected general diodes as opening switch to satisfy that requirements. With 200 resistor load, the experiment results show that the output voltage is 21kV, the rising time is about 21ns, and the pulse width (FWHM) is about 42ns.

  • PDF

회전기 고정자권선의 부분방전 진단용 평면 패치센서의 설계 및 실험

  • 양상현;박노준;김충식;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.228-228
    • /
    • 2009
  • In stator windings of a 6.6kV rotating machine, internal discharge, corona discharge, and surface discharge are mainly caused by internal voids and insulation degradation. In the case of the discharge spark and electromagnetic pulse generated from a discharge source, we can detect it using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, we designed and fabricated a planar patch sensor using a CST-MWS simulation, and PD signals from artificial defected stator windings were also measured by the sensor proposed in this study. Furthermore, In the results of the experiment, it showed similar performance to the HFCT sensor.

  • PDF