• Title/Summary/Keyword: pulse analyzer

Search Result 152, Processing Time 0.127 seconds

Study for Correlation of 3D-MAC and DSOM with ABR-2000 (피부전기저항측정기(ABR-2000)의 맥진기(3D-MAC) 및 한방진단시스템(DSOM)과의 상관성 연구)

  • Song, Jung-Oh;Kim, Min-Ae;Lee, In-Seon
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.31 no.1
    • /
    • pp.57-83
    • /
    • 2018
  • Purpose: This research has been carried out to find out correlation between test results of ABR-2000 and other diagnostic equipments to enhance significance of accurate diagnosis and clinical usage of ABR-2000. Methods: Duration of the 31 months from December 2012 to June 2015, records of 564 outpatients at gynecology department have been selected. The 564 patients were tested, using all 3 different test equipments of ABR-2000, DSOM, and 3D Blood Pressure Pulse Analyzer (3D-MAC) without test errors or mis-recordings. Correlation between 3D Blood pressure Pulse Analyzer, DSOM and ABR-2000 were analyzed by frequency & ratio factor of statistic data records of patients groups devided by 8 different disease symptom and by comparison of the groups in the form of Regulation and Graph presented on ABR-2000 equipment. Results: 1. The indicator L in all 1, 2, and 3 quadrant in the graph means the activity and reactivity of the upper body biodynamics detection rate is low and which result is very common symptom among gynecological patients. 2. The portion of patients with hypermenorrhea, endometritis, and menstrual pain symptom among the indicator L group in the reactivity 1-3 quadrantin is significantly high. 3. When 3D Mac analyzer indicates H, diastole decreases while systole increases and tachycardia increases then the blood circulation is expected to increase. In case of indication L, diastole increases and systole decreases then, the blood circulation is expected to decrease.

Characteristics of Fatigue in Sasang Constitution by Analyzing Questionnaire and Medical Devices Data (설문지와 의료기기 자료 분석을 통한 사상체질별 피로 특성 연구)

  • Kim, Koo;Ha, Ye-Jin;Park, Soo-Jeong;Choi, Na-Rae;Lee, Young-Seop;Joo, Jong-Cheon
    • Journal of Sasang Constitutional Medicine
    • /
    • v.25 no.4
    • /
    • pp.306-319
    • /
    • 2013
  • Objectives The purpose of this study was to find correlations between gastrointestinal disorders, pain, sleep disorder, fatigue, and to figure out characteristics of fatigue in Sasang Constitution using medical devices data. Methods Sixty three subjects were divided into fatigue group and non-fatigue group, both groups had to undergo blood tests, questionnaire, Sasang constitutional analysis tool (SCAT), pulse wave analyzer examination, heart rate variability examination, nail fold capillary microscopic examination. Results 1) The results of questionnaire about fatigue, gastrointestinal disorder, pain, sleep disorder, quality of life had significant differences between fatigue and non-fatigue groups. 2) Soeumin had more serious gastrointestinal problem and Soyangin had more serious sleep disorder in fatigue groups than non-fatigue groups. 3) According to blood test results, there was no difference between fatigue and non-fatigue groups. 4) Elastic parameter of pulse wave analyzer and nail fold capillary microscopic examination showed significant differences between fatigue and non-fatigue groups in Soyangin. Conclusions We reach the conclusion that fatigue is usually accompanied by gastrointestinal disorder, pain, sleep disorder, deterioration in the quality of life. In Soeumin, treating gastrointestinal disorders can be helpful for treatment of fatigue. In Soyangin, improving sleep disorder may be more effective way to treat fatigue.

Comparative Study on the Pulse Wave Variables and Sasang Constitution in Cerebral Infarction Patients and Healthy Subjects (뇌경새(腦梗塞) 환자(患者)와 건강인(健康人)의 맥상(脈象)과 사상체질(四象體質)에 관(關)한 연구(硏究))

  • Ko, Ki-Duk;Kim, Kyung-Yo;Kim, Jong-Yeol;Lee, Si-Woo;Joo, Jong-Cheon
    • Journal of Pharmacopuncture
    • /
    • v.10 no.2 s.23
    • /
    • pp.119-132
    • /
    • 2007
  • This study was performed to determine whether a pulse analyzer was useful 1) to characterize the variables of pulse wave of cerebral infarction patieno (CI), compared with those of healthy subjects, as well as 2) to determine Sasang Constitution in CI and healthy subjects. 1. Calibrated in Gwan, the amount of energy(Energy), height of main peak(H1), height of aorticvalley(H2), height of aortic peak(H3), total area of pulse wave(At), and area of main peak width(Aw) of the CI group were higher than those of the healthy group. 2. Calibrated in Cheek, Energy, H1, H2, H3, height of valve valley(H4), At, Aw, and main peak angle(MPA) of the CI group were higher than those of the healthy group. 3. Among the healthy (subjects) group, Taeumin showed the highest contact pressure(CP) and height of valve peak(H5) calibrated in Chon. The main peak width divided by whole time of pulse wave(MPW/T) calibrated in Gwan and Cheok, was highest in Soyangin and was lowest in Taeumin. The H3 divided by H1(H3/H1) and the time to valve valley minus the time to main peak and divided by T[(T4-T1)/T] calibrated in Cheek were highest in Soyangin. The time to main peak(T1) was longest in Soumin. 4. Among the CI group, At calibrated in Chon was widest in Taeumin and was narrowest in Soumin The time to aortic peak(T3) calibrated in Cheek was longest in Soumin and was shortest in Soyangin. The time to valve peak(T5) was shortest in Soyangin. 5. There were main effects of cerebral infarction in the area of systolic period(As) and area of diastolic period(Ad) calibrated in Chon, Energy calibrated in Cwan, and Energy, H1, H2, H3, (H4+H5)/Hl, and MPA calibrated in Cheek. 6. There were main effects of Sasang Constitution in (T4-T1)/T, area of systolic period(As), and Ad calibrated in Chon. 7. The interactions between the cerebral infarction and Sasang Constitution were observed in H5/H1 , T, At, As, Ad, and MPA calibrated in Chon, H4, T4, (T4-T1)/T, As, and Ad calibrated in Cwan, and 74,75, and MPW calibrated in Cheok. Therefore, we concluded that pulse analyzer was useful to determine the risk degree of cerebral infarction and Sasang Constitution.

Pulse-echo response of ultrasonic transducer fabricated with PZT-polymer 3-3 type composite (PZT-고분자 3-3형 복합압전체 소자로 제작된 초음파 트랜스듀서의 펄스에코 응답특성)

  • 박정학;최헌일;손무현;사공건
    • Electrical & Electronic Materials
    • /
    • v.9 no.10
    • /
    • pp.1053-1059
    • /
    • 1996
  • The pulse-echo response of the piezoceramics PZT-polymer 3-3 type composite transducers with various PVA additions were investigated. The PZT powder was prepared by the molten salt synthesis method. The porous PZT specimens will be used as a filler to make 3-3 type comosite were prepared from a mixture of PZT and polyvinylalcohol(PVA) sphere by utilizing BURPS(Bumout Plastic Sphere) technique. It was shown that the transmitting and receiving sensitivity of 3-3 type piezoelectric composite transducers could be improved than that of solid PZT transducers. The reason is that 3-3 type piezoelectric composite have low dielectric constant, density and acoustic impedance. The distance between transducer and reflector was in good agreement with the distance calculated from the longitudinal velocity of the specimens and receiving time observed pulse-echo responses on the ultrasonic transducer analyzer.

  • PDF

Development of Measurement System for Industrial Transportable Gamma Ray CT (이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

Study of Time Domain Measurement and Analysis Technique Using Network Analyzer for UWB Antenna link Characterization (UWB 안테나 링크 특성화를 위한 네트워크 분석기를 이용한 시간영역 측정 및 분석기술 연구)

  • Koh, Young-Mok;Kim, Jung-Min;Kim, Keun-Yong;Ra, Keuk-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.69-80
    • /
    • 2012
  • In this paper, we studied the time-domain measurement and analysis techniques using a network analyzer for characterization UWB antenna link radiating impulse signal. For this purpose, we developed the CZT(Chirp z-Transform) algorithm which has characterized zoom-in function and transformed the acquired data from network analyzer to time domain format. Using the CZT algorithm, we proves that it would be better efficient and more faster than the DFT for analyzing the waveform and also be able to zoom-in the arbitrary region.

A Study on the Characteristics of Pulse Waves according to Eight Principle Pattern Identification in 500 Women (500명 여성을 대상으로 한 팔강변증에 따른 맥파 특성 연구)

  • Lee, In Seon;Jeon, Soo Hyung;Kang, Chang Wan;Kim, Jong Won
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.35 no.6
    • /
    • pp.274-279
    • /
    • 2021
  • This study was conducted to find objective diagnostic indicators for the Eight Principle Pattern Identification using a pulse wave analyzer. Typology Complexion Pulse and Symptom data from 500 women over the age of 18 were used. Five experts made a diagnosis of Eight Principle Pattern Identification and divided the subjects into 'Yin-Yang', 'Exterior-Interior', 'Cold-Heat', 'Deficiency-Excess' groups. Their pulse waves were measured in the left and right radial arteries, and it was investigated whether there was a significant difference between groups in the pulse wave parameter values. 'Yin' group showed a significantly lower value in the left radial artery for Ener, Emin, EIX, T4T, T4TT parameters and in the Right for T2, T2T, T5. The Vmag, As and Ad parameters were significantly different between the 'Exterior' and 'Interior' groups. 'Heat' group showed a significantly higher value in the right radial artery for RAI/t parameter. 'Deficiency' group showed a significantly higher value in the right radial artery for W, Angl parameters. Through this study, significant pulse wave parameters were found, and they can be used as objective diagnostic indicators for Eight Principle Pattern Identification.

Insulation Aging Properties of Off-Line and On-Line High Voltage Motor Stator (정지중 및 운전중 고압전동기 고정자 권선의 절연열화 특성)

  • Kim, Hee-Dong;Lee, Young-Jun;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1694-1696
    • /
    • 2001
  • Partial discharge(PD) tests are used to evaluate the insulation condition of stator windings in six 6.6kV motors. These tests were conducted using a conventional partial discharge detector (PDD), turbine generator analyzer(TGA) and partial discharge analyzer(PDA). Off-line PD measurements were performed on six 6.6kV motors. PD magnitudes ranged from 740 pC to 5,100 pC at the normal line-to-ground voltage. Six 6.6kV motors have been equipped with eighteen 80pF epoxy-mica couplers(one per phase) on the motor terminal boxs. The PD pulse from sensors were measured with the TGA and PDA instruments on a normally operating motors. The PDD, TGA and PDA test results showed that internal discharge was detected in voids of the groundwall insulation.

  • PDF

A Novel Sensitivity Verification Method for the UHF Partial Discharge Detection System in Gas Insulated Switchgear (GIS) (가스절연개폐장치용 UHF 부분방전검출장치의 새로운 감도 측정방법)

  • Gu, Seon-Geun;Park, Gi-Jun;Yun, Jin-Yeol
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.450-455
    • /
    • 2001
  • We proposed a new sensitivity verification method for the UHF partial discharge(PD) detection system. Initially, we measure the UHF power induced by 5 pC PD which takes place near UHF sensor. Subsequently, we inject the swept UHF signal from a network analyzer into the GIS and measure the attenuation of the signal along the 71S Both the UHF power by 5 pC PD and the attenuation make it possible to verify the sensitivity and spatial coverage of the PD detection system. This method doesn\`t require the calibration of injected pulse type UHF signal into the GIS and makes us precisely measure the attenuation in frequency domain.

  • PDF

Finite Element Analysis of Packaging Shape for Pulse Diagnosis Sensor (FEM 분석을 통한 맥진센서모듈의 패키징 형태와 응력분포)

  • Shin, Ki-Young;Lee, Sang-Sik;Joo, Su-Bin
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.3
    • /
    • pp.167-173
    • /
    • 2011
  • Since many blood pressure pulse analyzer made to measurement of a pulse wave in quantitative way has been started, some sorts of pressure sensors are being developed. The result could differ and this cause either type of sensor or module shape, when pulse wave is measured. In this paper, calculate and compare the pressure sensor's stress distribution according to thickness of PDMS coating and existence of guide through Finite Element Method. As a result, the center of pressure sensor's stress increase as much as 24% as it is reduced as much as 0.3 mm that the PDMS coating thichness of pulse diagnostic sensor module, on the other hand the surrouding censor of center sensor's stress is reduced as much as 4.9%, and transmissive proportion of stress is small as little as 2.7%, When coating has guide.