• 제목/요약/키워드: pulse analysis

검색결과 2,098건 처리시간 0.033초

지첨용적맥파의 파형분석과 주파수분석에 대한 문헌적 연구 (A Systemic Review of Pulse Contour Analysis and Fourier Spectrum Analysis on the Photoplethysmography of Digit)

  • 남동현;박영배;박영재;신상훈
    • 대한한의진단학회지
    • /
    • 제11권1호
    • /
    • pp.48-60
    • /
    • 2007
  • Palpation of the pulse has been used in Korean traditional medicine since ancient times to assess physical health. Pulse wave contour may be obtained by measuring arterial pressure or blood volume change of skin. The latter is called as Photoplethysmography(PPG) or digital volume pulse(DVP). The PPG signal is measured by a device comprising an infrared light sourece and a photodetector. Although less widely used, this technique deserves further consideration because of its simplicity and ease of use. The contour of the PPG is formed as a result of a complex interaction between the left ventricle and the systemic circulation. It usually exhibits an early systolic peak and an early diastolic peak. the first peak is formed mainly by pressure trasmitted along a direct path from the left ventricle to the finger. The second peak is formed in part by pressure transmitted along the aorta and large arteries to sites of impedance mismatch in the lower body. The contour of the PPG is sensitive to changes in arterial tone and is influenced by ageing and large artery stiffness. Measurements taken directly from the PPG or from its second derivative can be used to assess these properties. In some mathematical approaches, the extraction of periodic components using frequency analysis was tried to analysis of the PPG. But we don't understand yet what kind of factor in the cardiovascular system or human body is related with the respective specific Fourier components of PPG. This review describes the background to measurement principles, representative contour, contour analysis and frequency domain analysis of PPG, and current and future.

  • PDF

미출산 여성과 출산 여성의 맥파 비교 - 난임 맥파 지표 연구를 위한 - (A Study on the Pulse Wave Parameter in Non Delivery and Delivery Women)

  • 서창운;김경철;김이순
    • Korean Journal of Acupuncture
    • /
    • 제29권2호
    • /
    • pp.200-215
    • /
    • 2012
  • Objectives : The purpose of this study is to investigate the differences of pulse wave parameter between the non delivery group (single women with no childbirth experience) and the delivery group (married women who gave birth(s) in delivery). Methods : Sixty one healthy (non delivery) nulliparous women and fifty three delivery women participated in this study. We used 3 dimensional pulse analyser(3D MAC, DAEYOMEDI co., Korea), which measures radial pulse waveform non-invasively by way of tonometry method at 5 different applied pressure levels. From 114 subjects enrolled, pulse wave parameters were measured on the six locations of Chon, Kwan and Cheok of each hands. Results : Delivery group's pulse showed larger values in the following pulse wave parameters (Energy, Ap, RAI, As, Aw, h1, h2, h4, h4/h1, t, t1, t2, t4, Wm, Wm/t). Non delivery group's pulse indicated larger values in the pulse wave parameters such as Energy of left Chon, difference pulse energy between left and right hand, Ad, h5, h5/h1, t5. Conclusions : According to the analysis result, delivery group's pulse has bigger values in most part of pulse wave parameters, especially in Kwan and Cheok which correspond to Liver, Kidney, and Myeong-mun. We interpret these results that delivery women are more mature and stable in reproductive organs than non delivery group, as they have experienced delivery(deliveries) and child-caring through married life.

결합 마이크로스트립 선로상의 펄스형태 신호의 전파 및 누화 특성 해석 (Propagation and Crosstalk Characteristic Analysis of Pulse Shaped Signals on the Coupled Microstrip Lines)

  • 박순근;김남;이승엽;장우현
    • 한국전자파학회논문지
    • /
    • 제8권5호
    • /
    • pp.516-524
    • /
    • 1997
  • 결합마이크로스트립 선로에서 여러형태의 펄스신호(가우시안 펄스, 구형 펄스, 사다리꼴 펄스, RF펄스)의 전 파특성을 해석하였다. 펼스신호의 시간영역의 응답을 구하기 위하여 비교적 정확성을 갖고 시율레이션하기에 편 리한 수치적분볍을 이용하였으며, 주파수에 따른 결합선로에서의 분산특성은 Kirschning과 Jansen의 closed f form 근사식을 사용하였다. 결합마이크로스트립 션로의 기하학적 구조(비유전율$\varepsilon_r$ , 기판두께 h, 스트립폭 w, 선로간의 간격 s)와 펄스폭 $\tau$ 등이 분산에 미치는 영향을 분석하였다. 그 결과 다른 파라미터에 비해 선로간의 거리가 펄스의 왜곡에 큰 영향을 주는 파라미터임을 알 수 있었다. 본 논문의 결과는 MIC 및 MMIC 회로의 설계시 마이크로스트립 선로의 비유전율, 기판두께, 스트립폭 그리고 선호 펄스의 펄스폭 등의 trade-off 결정에 적합하다.

  • PDF

개선된 블록 펄스 계수 추정 기법을 이용한 선형 시불변계의 상태 추정에 관한 연구 (A Study on The State Estimation of The Time-Invariant Linear Systems via The Improved Parameter Estimation Method for The Block Pulse Coefficients)

  • 김태훈;김진태;정제욱;심재선
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권4호
    • /
    • pp.137-143
    • /
    • 2002
  • Because Block Pulse functions are used in a variety of fields such as the analysis and controller design of systems, it is necessary to find the more exact value of the Block Pulse series coefficients. This paper presents a method for the state estimation of the time-invariant linear systems via the improved estimation method for the Block Pulse coefficients by using the Simpson's rule. The proposed method using the Simpson's rule improve the accuracy of the Block Pulse coefficients.

LD gain-switching에 의한 초단 광 펄스 발생 해석 (Analysis of ultra-short optical pulse generation by LD gain-switching)

  • 김윤중;김동각;김창민
    • 전자공학회논문지D
    • /
    • 제34D권10호
    • /
    • pp.85-92
    • /
    • 1997
  • For a InGaAsP buried - heterostructrue $1.3\mu\textrm{m}$ LD with fabry-perot cavity structure, the procedures of ultra-short optical pulse genration ar eanalyzed by simulating the rate equations. Investigting the effects of injected current pulse parameters such as bias $J_b$, pulse width $T_d$ and pulse amplitude $J_p$ on the generated optical pulses, we derive the optimum conditions to obtain a single optical pulse with strong peak value. We also observe that the repetition rate of current pulses needs to be restricted under a certain threshold to generate a train of single optical pulses, and that the period doubling phenomenon takes place by increasing the repitition rate.

  • PDF

80-MW 클라이스트론 부하용 200-MW 펄스 트랜스포머의 성능시험 (Performance Test of 200-MW Pulse Transformer for 80-MW Klystron Load)

  • 장성덕;오종석;손윤규;조무현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2167-2169
    • /
    • 1999
  • A pulse transformer producing pulses with the peak power of 200-MW (400 kV 500 A at load side with $4.4{\mu}s$ flat-top) is required to drive the 80-MW pulsed klystron in the PLS linac. We have designed and manufactured the high power pulse transformer with 1 : 17 turn ratio. Its primary functions are to match the impedance of klystron tube to the modulators, and to provide step-up of the voltage. To obtain a fast rise time of the pulse voltage. Low leakage inductance and low distributed capacitance design is very important. In this paper, we discuss the equivalent circuit analysis of the pulse transformer, and present the full power performance test results of pulse transformer.

  • PDF

Thyratron을 이용한 고압펄스 발생장치 (High voltage pulse power supply using thyratron)

  • 김태진;김성철;김은수;백주원;;이홍식;전성즙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2127-2129
    • /
    • 1998
  • In this paper, discharging part of high voltage pulse power supply of E-beam generating device is simulated and experimented. It is composed of high voltage part and high voltage pulse part. High voltage part is AC 380, DC/DC converter, high voltage high frequency transformer. High voltage pulse part is double pulse forming network and Thyratron. In the result, computer simulation analysis is same to experimental result and high voltage pulse is obtained 10kV, 4A, 10uS.

  • PDF

맥파자동진단을 위한 하드웨어의 설계 및 특성점 검출 알고리즘에 관한 연구 (A Study on the Significant Point Detection Algorithm and Design of Hardware for Pulse Automatic Diagnosis)

  • 이준영;이정환;이명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2255-2258
    • /
    • 1998
  • Method of diagnosis in oriental medicine, the unbalance of the physiological function of the five viscers and six bowels of the human body is determined from time immemorial with the condition of blood circulation which is performed through blood vessels by the vitality of the heart. In oriental medicine, treatment is largely attempted by adjusting this unbalance. The analysis of pulse wave, which mainly measures the changes in blood flows, is to evaluate the shapes of a pulse wave rather than the quantitative changes like rates and strength of the pulse. This paper presents the development of Hardware System and Pulse Diagnosis Algorithm for automatic diagnosis of the pulse wave. This system makes the precise diagnosis and the objective recording possible.

  • PDF

전극길이 및 펄스반복율에 대한 부하임피던스 특성변화에 관한 연구 (A Study on the Characteristics of Corona Critical Voltage on Increasing Load Impedance)

  • 정종한;송우정;전진안;이유수;김휘영;김희제
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.184-186
    • /
    • 2002
  • In this paper, we studies EMTP analysis and characteristics of critical voltage of pulse corona and load impedance on variable electrode length. To obtain a stable pulse voltage, we designed a compact pulse generator switched MOSFET and tested their characteristics by adjusting electrode length and pulse repetition. As a result, critical voltage of pulse corona and load impedance on increasing electrode length were decreased. These results indicate we can control critical voltage of pulse corona and suppress arc discharging between two electrodes.

  • PDF

월경장애를 가진 여고생의 맥진분석 (Analysis of Blood Pressure Pulse in Female High School Students with Menstrual Disorders)

  • 김수현;조혜숙;이인선
    • 대한한방부인과학회지
    • /
    • 제26권1호
    • /
    • pp.82-91
    • /
    • 2013
  • Objectives: The purpose of this study is to find out the patterns of teenage girls who is easy to suffer from Menstrual Disorders. Methods: The data from the 1681 participants were collected using a structured menstrual history questionnaire. Based on the survey responses, we had 97 adolescents with menstrual disorder as the test group and 97 adolescents without menstrual disorder as the control group. The clinical trials subjects were asked to respond to another questionnaire for identifying Blood Pressure Pulse Analyzer tests. We identified significant variables for dysmenorrhea from comparison between the test and control group; a binary response variable from the test group's responses for ever experiencing dysmenorrhea and explanatory variables from Blood Pressure Pulse Analyzer. Results: The reselts of Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower in dysmenorrhea group than the control group. The reselts of Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower, and T4_R were higher in hypomenorrhea group than the control group. The reselts of Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower in Irregular Menstruation group than the control group. Conclusions: Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower in the test group than the control group.