• Title/Summary/Keyword: pulse I-V

Search Result 161, Processing Time 0.026 seconds

Development and Testing of a Prototype Long Pulse Ion Source for the KSTAR Neutral Beam System

  • Chang Doo-Hee;Oh Byung-Hoon;Seo Chang-Seog
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.357-363
    • /
    • 2004
  • A prototype long pulse ion source was developed, and the beam extraction experiments of the ion source were carried out at the Neutral Beam Test Stand (NBTS) of the Korea Superconducting Tokamak Advanced Research (KSTAR). The ion source consists of a magnetic bucket plasma generator, with multi-pole cusp fields, and a set of tetrode accelerators with circular apertures. Design requirements for the ion source were a 120kV/65A deuterium beam and a 300 s pulse length. Arc discharges of the plasma generator were controlled by using the emission-limited mode, in turn controlled by the applied heating voltage of the cathode filaments. Stable and efficient arc plasmas with a maximum arc power of 100 kW were produced using the constant power mode operation of an arc power supply. A maximum ion density of $8.3{\times}10^{11}\;cm^{-3}$ was obtained by using electrostatic probes, and an optimum arc efficiency of 0.46 A/kW was estimated. The accelerating and decelerating voltages were applied repeatedly, using the re-triggering mode operation of the high voltage switches during a beam pulse, when beam disruptions occurred. The decelerating voltage was always applied prior to the accelerating voltage, to suppress effectively the back-streaming electrons produced at the time of an initial beam formation, by the pre-programmed fast-switch control system. A maximum beam power of 0.9 MW (i.e. $70\;kV{\times}12.5\;A$) with hydrogen was measured for a pulse duration of 0.8 s. Optimum beam perveance, deduced from the ratio of the gradient grid current to the total beam current, was $0.7\;{\mu}perv$. Stable beams for a long pulse duration of $5{\sim}10\;s$ were tested at low accelerating voltages.

장파장 GaInAsP/Inp DH 레이저의 제작과 발진특성

  • Lee, Yong-Tak;Hong, Chang-Hui
    • ETRI Journal
    • /
    • v.4 no.1
    • /
    • pp.3-8
    • /
    • 1982
  • 성장된 GaInAsP/InP DH wafer로부터 상온에서 duty 5%까지 Pulse 동작이 가능한 전면전극(broad contact) 및 stripe 구조 LD(711이저 다이오드)를 제작하였다. 또 이렇게 제작된 LD의 I-V특성, 1-L 특성 및 발진파장 등을 조사하기 위해 LD 구동회로 및 Ge 태양전지와 Ge-APD를 이용한 광 검출회로를 제작하였다. 이들을 이용해 제작한 LD의 특성을 조사한 결과 stripe 구조 LD인 경우 발진개시전류($I_th$)가 900mA, 발진파장이 $1.29\mum$, 파장반치폭(FWHM)이 $60\AA$였으며 $1.33I_th$까지 kink 없이 동작이 가능하였다.

  • PDF

Design and Operation Characteristics of 2.4MJ Pulse Power System for Electrothermal-Chemical(ETC) Propulsion(I) (전열화학추진용 2.4MJ 펄스파워전원의 설계와 동작특성(I))

  • Jin, Y.S.;Lee, H.S.;Kim, J.S.;Cho, J.H.;Lim, G.H.;Kim, J.S.;Chu, J.H.;Jung, J.W.;Hwang, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1868-1870
    • /
    • 2000
  • As a drive for an ETC (Electro-thermal Chemical) launcher, a large pulse power system of a 2.4MJ energy storage was designed, constructed and tested. The overall power system consists of eight capacitive 300kJ energy storage banks. In this paper we describe the design features, setup and operation test result of the 300kJ pulsed power module. Each capacitor bank of the 300kJ module consists of six 22kV 50kJ capacitors. A triggered vacuum switch (TVS-43) was adopted as the main pulse switch. Crowbar diode circuits, variable multi-tap inductors and energy dumping systems are connected to each high power capacitor bank via bus-bars and coaxial cables. A parallel crowbar diode stack is fabricated in coaxial structure with two series 13.5kV, 60kA avalanche diodes. The main design parameters of the 300kJ module are a maximum current of 180kA and a pulse width of 0.5 - 3ms. The electrical performances of each component and current output variations into resistive loads have been investigated.

  • PDF

A Buck-Boost Converter-Based Bipolar Pulse Generator

  • Elserougi, Ahmed A.;Massoud, Ahmed M.;Ahmed, Shehab
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1422-1432
    • /
    • 2017
  • This paper presents a buck-boost converter-based bipolar pulse generator, which is able to generate bipolar exponential pulses across a resistive load. The concept of the proposed approach depends on operating the involved buck-boost converters in discontinuous current conduction mode with high-voltage gain and enhanced efficiency. A full design of the pulse generator and its passive components is presented to ensure generating the pulses with the desired specifications (rise time, pulse width, and pulse magnitude) for a given load resistance and input dc voltage. In case of moderate pulsed output voltages (i.e. few of kV), one module of the presented bipolar generator can be employed. While in case of high-voltage pulsed output, multi-module version can be employed, where each module is fed from an isolated dc source and their outputs are connected in series. Simulation models for the proposed approach are built to elucidate their performance in case of one-module as well as multi-module based generator. Finally, a scaled-down prototype for one-module of buck-boost converter-based bipolar pulse generator is implemented to validate the proposed concept.

Two Types of Voltage-activated Calcium Currents in Goldfish Horizontal Cells

  • Paik, Sun-Sook;Bai, Sun-Ho;Jung, Chang-Sub
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.9 no.5
    • /
    • pp.269-273
    • /
    • 2005
  • In horizontal cells (HCs) that were freshly dissociated from goldfish retina, two types of voltagedependent calcium currents ($I_{Ca}$) were recorded using a patch-clamping configuration: a transient type current and a sustained type current. The cell was held at -40 mV, and the prepulse step of -90 mV was applied before command pulse between -65 and +55 mV. The transient $Ca^{2+}$ current was activated by depolarization to around -50 mV from a prepulse voltage of -90 mV lasting at least 400 ms and reached a maximal value near -25 mV. On the other hand, the sustained $Ca^{2+}$ current was induced by pre-inactivation for less than 10 ms duration. Its activation started near -10 mV and peaked at +20 mV. $Co^{2+}$ (2 mM) suppressed both of these two components, but nifedipine ($20{\mu}M$), L-type $Ca^{2+}$ channel antagonist, blocked only the sustained current. Based on the activation voltage and the pharmacolog$I_{Ca}$l specificity, the sustained current appears to be similar to L-type $I_{Ca}$ and the transient type to T-type $I_{Ca}$. This study is the first to confirm that transient type $I_{Ca}$ together with the sustained one is present in HCs dissociated from goldfish retina.

MAGFET Hybrid IC with Frequency Output (주파수 출력을 갖는 MAGFET Hybrid IC)

  • Kim, Si-Hon;Lee, Cheol-Woo;Nam, Tae-Chul
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.194-199
    • /
    • 1997
  • When voltage or current gets out of the magnetic sensor as it is, we have often faced the problems such as introduction of noise and loss of voltage. In order to reduce these problems, a 2 drain MAGFET operating in the saturation region and fabricated by CMOS process, the system of I/V converter, VCO with operational amplifier, and V/F conversion circuits with Schmitt Trigger are designed and fabricated in one package. The absolute sensitivity of magnetic sensor shows 1.9 V/T and the product sensitivity is $3.2{\times}10^{4}\;V/A{\cdot}T$. The characteristic of V/F conversion is very stabilized and has the value of 190 kHz/T.

  • PDF

Effect of Nuclear Transfer Methods on In Vitro Development of Reconstituted Bovine Embryos I. Effect of Transfer Time of IVF Donor Nuclei and Electric Stimulation on Fusion and In Vitro Development (소에서 핵이식 방법이 재구축배의 체외발달에 미치는 영향 I. 체외수정 공핵배 핵의 이식시기와 전기자극에 따른 융합과 체외발달)

  • 정영채;김창근;송학웅;정영호;윤종택;이종완;김흥률;김광식
    • Korean Journal of Animal Reproduction
    • /
    • v.20 no.4
    • /
    • pp.459-465
    • /
    • 1997
  • The present study was undertaken to determine the effect of NT time on the rate of fusion a and suhseguent development In vitro and determine the optimal strength and duration of DC pulse for electrofusion of IVF donor embryo nuclei and IVM recipient oocytes. The recipient oocytes were enucleated 25 ~ 2Sh after IVM and further cultured for 18 ~ 20h prior to fusion for oocyte aging. IVF embryos as donor nuclei were C co cultured with BOEC for 16- to 32-cell stage development. The transfer time of donor bIas tomeres was 1~3h post-enucleation in early NT group and 1 ~ 18h post-enucleation in late NT group, respectively and fusion was performed 43~4Sh post-IVM. The fusion rate did not differ between the early NT and late NT group, but the rate of cleavage and 8- to 16-cell stage embryos in the late NT group was more higher than that in the early NT group. The fusion, cleavage and M+B development was high from O.7SkV /cm DC than from 1.0kV /cm DC voltage, resulting in 17.6% M+B from 0.75kV /cm DC voltage. No difference in fusion rate was among pulse durations, but 50 and 70 usec pulse duration showed slight high cleavage and M + B d development. The results indicate that the best NT time of IVF donor blastomeres into the enucleated oocytes was 42~44 post-IVM and the most suitable condition for electrofusion was a single 0.7SkV /cm DC voltage for SO~70$\mu$sec.

  • PDF

Design and Test Results of High-Power Pulse Generator System for Industrial Accelerator Application (산업용 가속기용 고출력 펄스시스템의 설계와 시험)

  • Jang, S.D.;Kim, S.H.;Yang, H.Y.;Cho, M.H.;Ko, I.S.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1370_1372
    • /
    • 2009
  • A conventional linear accelerator system requires a flat-topped pulse with less than $\pm$ 0.5% ripple to meet the beam energy spread requirements and to improve pulse efficiency of RF systems. A a line-type pulsed modulator is widely used in pulsed power circuits for applications such as accelerators, radar, medical radiation, or ionization systems. The high-voltage pulse generator system with an output voltage of 284 kV, a pulse width of $10{\mu}s$, and a rise time of $0.84{\mu}s$ has been designed and fabricated to drive a klystron which has 30-MW peak and 60-kW average RF output power. The high-voltage test was performed using the klystron load. This thesis describes the design and test results of high-power pulse generator system for industrial accelerator application. The experimental results were analyzed and compared with the design.

  • PDF

development of Underwater Data Communication System (I) -Echo Signal Transfer System- (수중 데이터 통신 시스템의 개발에 관한 연구 (I) -에코 신호 전송 시스템-)

  • 신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.284-290
    • /
    • 1999
  • This paper describes a Frequency Shift Keying (FSK) modulator and demodulator and the experimented underwater data ommunication equipment to transfer the analog echo signal in real-time from an underwater vehicle to the mother ship. The system consists of an echo signal transfer unit equipped to the vehicle and an ultrasonic receiver equipped on the ship. The former includes an ultrasonic transceiver unit of 180kHz for echo detection and a continuous wave transmitter of 50kHz with a FSK modulator for echo transmission to the ship. The latter includes an ultrasonic receiver of 50kHz and the FSK demodulator. The results of experiment are as follows. 1. The characteristics of the FSK modulating and demodulating circuits designed with the use of C-MOS IC 4046 was good and confirmed its usefulness in underwater data communication system.2. The prototype ultrasonic transceiver unit shows profitable driving power while the pulse duration was short less than 3 msec, but it was found that the driving power is not sufficient while the long pulse duration or continuous wave is used. The gain of the ultrasonic receiver was 80 dB and the receiving bandwidth 700Hz (at - 3 dB point).3. It was found that the system designed by the author has some possibility to use in underwater echo transfer.4. At the FSK modulator, the widths of voltage and frequency which represent linearity were 3.5 V, 1600Hz, respectively, at the FSK demodulator 2.6 V, 700Hz, respectively.

  • PDF