• Title/Summary/Keyword: pulse 시간

Search Result 1,009, Processing Time 0.028 seconds

Implementation of Intelligence Pulse Wave Detection System (지능형 맥진기 구현)

  • Hong, Y.S.;Yu, J.S.;Chang, S.J.;Sun, S.H.;Lee, W.B.;Nam, D.H.;Yu, M.S.;Choi, M.B.;Lee, S.S.
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.245-254
    • /
    • 2013
  • In oriental medicine, it is possible to classify and treat many diseases using the pulse wave detection system. Other problems may arise. As it is a very subjective way to analyze the pulse wave. One problem of the conventional pulse wave detection system is that the arterial pulse sensor is not located correctly at the radial artery. Threrefore measurement results can differ depending on the measurement position and the measurement procedure. This is mostly due to it's sensitivity to high reproducibility. In order to solve this problem this paper proposes an algorithm to analyze the weak pulse wave symptom and strong pulse wave symptom. It uses the portable pulse wave detection system which includes a Hall Sensor. As a final result, it analyzed the weak pulse wave symptom and strong pulse wave symptom by the SPSS statistics technique. It proves that N time (notch point time) and S Amp (rise waveform size) mean values are significantly different in 95% confidence interval.

Implementation of the Wireless Pulse Transit Time Monitoring System for Ubiquitous Healthcare (유비쿼터스 헬스케어를 위한 무선 맥파전달시간 측정시스템 구현)

  • Jung, Hwan;Jo, Kyung-Min;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.624-627
    • /
    • 2008
  • 본 연구에서는 유비쿼터스 헬스케어를 위하여 비침습적으로 측정기 가능하고, 많은 건강정보를 포함하고 있는 심전도(electrocardiogram, ECG)와 광전용적맥파(photo plethysmograph, PPG)를 측정하고자 하였다. 이를 위하여 배터리로 구동 가능한 초소형의 심전도 및 맥파측정 시스템의 구현을 위하여 각각의 신호를 검출 및 신호처리하기 위한 회로를 구현하였다. 그리고 계측된 심전도 및 맥파신호의 무선전송을 위하여 초저전력 무선센서네트워크 기술을 적용한 무선 생체신호 전송시스템을 구현하였다. 계측된 심전도의 R파 정점과 인체의 말초부위에서 측정한 맥파의 기준점 사이의 시간인 맥파전달시간(pulse transit time, PTT)을 분석하여 심장에서 말초부위까지 혈관의 물리적 특성을 평가함으로써 동맥경화와 같은 혈관질환의 사전모니터 링이 가능한 시스템을 구현하고자 하였다.

  • PDF

Time-Domain Model of Surface Clutter for Airborne Phase-Array Radar (항공기 위상 배열 레이더에서 시간 영역의 지상클러터 생성 모델)

  • Kim, Tae-Hyung;Kim, Eun-Hee;Kim, Seon-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.7
    • /
    • pp.730-736
    • /
    • 2013
  • Time-domain clutter generation model for airborne pulse doppler phase-array radar is presented. Time-domain surface clutter signal is generated assuming earth of a sphere and considering geometry of a clutter patch, and generation of sub-array clutter signal is presented. The generated sub-array clutter signal can be used by simulation input signal in various radar applications of DBF(Digital Beamforming), ABF(Adaptive Beamforming), Stap(Space-Time Adaptive Processing) and etc.

A readout method using pulse peak-time capture for radiation detectors (펄스의 피크시각 포착을 이용한 방사선 검출기의 신호처리 방법)

  • Kim, Jong-ho;Kwon, Young-mok;Hong, Hyoung-pyo;Che, Gyu-shik
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.6
    • /
    • pp.651-658
    • /
    • 2017
  • There were many studies on the development of radiation measuring instruments to detect the presence of radiation. In particular, the signal processing method and treatment without loss of the detection signal are very important. The common feature for these studies is the peak-hold method that keeps the peak value of input signal uniform for a short time, readouts its value, discharges electrical value, and then waits for next signal. We propose the new methodology to capture the pulse peak value from the radiation detector and read the value directly other than peak-hold method. This method has merit of accurate reading the input signal pulse peak value without complicate process of holding for a period or initializing of input signal, and then be verified to be adequate through simulation of actual example.

Respiratory Effort Monitoring Using Pulse Transit Time in Human (인체에서 맥파전달시간을 이용한 호흡노력 모니터링)

  • 정동근
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.485-489
    • /
    • 2002
  • In this study. respiratory efforts were monitored by the change of pulse transit time (PTT) which is related with the arterial pressure PTT is the time interval between the peak of R wave in ECG and the maximal slope point of photoplethysmogram(PPG). Biosignals, ECG and finger photoplethysmogram(PPG), were converted to digital data, and PTT was evaluated in personal computer with every heart beat. Results were presented as a graph using spline interpolation. The software was implemented in C$\^$++/ as a window-based application program. PTT was periodically changed according to airflow in resting respiration. In the resting respiration, PTT was changed according to the respiratory cycle. The amplitude of PTT fluctuation was increased by deep respiration, and increased by partial airway obstruction. These results suggest that PTT is responsible to respiratory effort which could be evaluated by the pattern of PTT change. And it is expected that PTT could be applied in the monitoring of respiratory effort by noninvasive methods, and is very useful method for the evaluation of respiratory distress.

The Tire Damage Classification by Pulse Interval Time Density Function of Ultrasonic Wave Envelope on Driving (주행 중 타이어 손상에 의해 발생하는 초음파 포락선 신호의 펄스 간격 시간밀도함수에 의한 손상 분별)

  • Shin, Seong-Geun;Kang, Dae-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.3
    • /
    • pp.41-46
    • /
    • 2011
  • The tire damage classification method is researched by periodicity detection of ultrasonic envelope signals to occur at the driving vehicle tire. Because periodic signals is generated by rotations of the damaged tire, it should convert to pulse for using the density function. After time intervals of pulses are represented by the density function, the dominant periodicity is detected. The threshold to make a pulse is calculated by moving average of envelope signals. The result of time density function in case of one damage material, the first peak's time is equals to tire's rotation period, 162ms and 102ms, about the speed of 50km/h and 80km/h. In case of more than one damage material, the sum of each peak's time is equals to tire's rotation period about the speed.

Application of NMR on the Study of Natural and Synthetic Diamonds (NMR을 이용한 천연 및 합성 다이아몬드의 특성 분석 연구)

  • Kim, Jong-Rang;Shon, Shoo-Hack;Kim, Jong-Gun;Kim, Jeong-Jin;Jang, Yun-Deuk
    • Journal of the Mineralogical Society of Korea
    • /
    • v.20 no.2 s.52
    • /
    • pp.97-102
    • /
    • 2007
  • NMR experiments with various pulse repetition delay time were carried out for the $^{15}N\;and\;^{13}C$ of a natural gem diamond and synthetic diamonds. The natural gem diamond had a weak $^{13}C$ peak at 34.1ppm when 30 second pulse repetition delay time was applied. Similar but more prominent $^{13}C$ peaks were observed at 34.2 ppm with 0.5 second pulse repetition delay time and at 34.7 ppm with 50 second pulse repetition delay time for the synthetic diamonds. Any meaningful $^{15}N$ peak was not observed for either natural or synthetic diamonds due to extremely low content of the $^{15}N$. Significant relationship was observed between relative spin-lattice relaxation times we estimated and the content of impurities. however, it was not possible to distinguish natural diamond from synthetic diamonds due to very similar characteristics of their $^{13}C$ NMR signals except relative spin-lattice relaxation times.

Estimation of PTT (Pulse Transit Time) by Multirate Filtering Analysis (다중레이트 필터링 기법을 이용한 맥파전달시간 추정)

  • Kim, Hyun-Tae;Kim, Jeong-Hwan;Kim, Kyeong-Seop;Lee, Jae-Ho;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1020-1026
    • /
    • 2013
  • Multirate filtering process on the biological signals like Electrocardiogram (ECG) and Photoplethysmogram (PPG) can be defined as the digital signal processing algorithm in which the sampling rate varies to omit or interpolate the intermediate values between the sampled data. With this aim, we suggest a new multirate filtering algorithm by deleting the extraneous data to eliminate the unwanted degradations such as granular noise due to the usage of high sampling frequency and simultaneously to detect the fiducial features of ECG and PPG with reducing the complexity of resolving fiducial points such as R-peak, Pulse peak and Pulse Transit Time (PTT). After the experimental simulations performed, we can conclude the fact that we can detect the fiducial features of ECG and PPG signal in terms of R-peak, Pulse peak and PTT without the loss of accuracy even if we do not maintain the original sampling frequency.

A Stable Threshold Linear Current Pulse Discriminator (안정한계 선형전류펄스변별기)

  • 김병찬
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.5 no.2
    • /
    • pp.8-14
    • /
    • 1968
  • A linear current-pulse discriminator consisting: of a transistor monostable multivibrator and a Si tunnel diode is described. The input currant pulse range is about 50$\mu$A~5.23mA. The measured maximum linearity deviation is $\pm$0.75% in the input current pulse range mentioned above. The pulse resolving ability of the discriminator measured depends upon the bias current through the T, D. ; and, under the reverse bias current of 3mA, the resolving time is 2rs if allow the excess pulse amplitude of 5%. The threshold stability of the discriminator depends mainly upon the stability of the peak current Ip of the T. D. ; and, under the ambient temperature variation from $0^{\circ}C$ to 5$0^{\circ}C$, no bigger threshold variation than the maximum linearity deviation, i. e. $\pm$ 0.75%, was observed.

  • PDF

A study of nonlinear interactions and optimum input parameters in all-optical phase-shift switches using ultrashort pulses with pulse-width less than 100fsec (100fsec이하의 극초단 광펄스를 사용하는 전광위상천이스위치에서 비선형상호작용 및 최적화 초기조건에 관한 연구)

  • Yoon, Ki-Hong;Song, Jae-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.6
    • /
    • pp.8-18
    • /
    • 2002
  • We study complicated nonlinear interactions of two orthogonally polarized pulses with pulse-width of less than 100fsec in the all-optical phase-shift switches, which use soliton pulse-train and fiber-splicing for control pulse to obtain multi-collisional $\pi$-phase-shift and consider Raman response function. We investigate switching performance in various input parameters such as input pulse-width and birefringence of fiber, and find optimum initial conditions for good switching performance in such all-optical switches.