• Title/Summary/Keyword: pulsatile

Search Result 244, Processing Time 0.029 seconds

Effect of Acupuncture at the LU5(Reinforcement), LU10(Reduction) on the Pulsation Scale of Chon, Gwan and Chuk region using High Resolution Infrared Camera (척택.어제 침자가 고해상도 적외선 카메라로 관찰한 촌구맥 부위의 온도 Pulsation 변화에 미치는 영향 연구)

  • Na, Chang-Su;Jeon, Hyo-Sang;Kim, Jee-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.127-133
    • /
    • 2011
  • Arteria radialis is a branch of the brachial artery extending down the forearm around the wrist where it closes to skin surface. In the oriental medicine, the skin above arteria radialis has an important role because oriental medicine practitioners put their finger tips on the area, and diagnose patient's health conditions by feeling the pulsation of the arterial contraction. The finger tip diagnostic method relies on subjective decision of the practitioner; and there is a need to develop an objective diagnostic modality. The pulsation of the arterial contraction appears not only a movement on the site but also as temperature fluctuation due to pulsatile feeding of warmer blood. The goal of this study is to demonstrate a feasibility of using an infrared camera quantitatively to detect the temperature fluctuation on the skin. Clinical important three different areas, called chon, gwan, chuk, near a wrist where the arteria radialis reaches close to skin surface are marked with small pieces of surgical tape. A high-speed and high-resolution infrared camera with a 3 cm of field of view measures these areas for 10 second at 200 frames per second with a 320*240 pixel size. The pulsatile temperature fluctuation is calculated after passing a band pass filter to remove any stationary temperature over 10 second. The temperature fluctuation of a healthy male volunteer is measured at a room temperature as a control, and is compared with another measurement performed after 20 minutes staying in a room at a 40 degree Celsius. This comparison is repeated for three times, and indicates that the fluctuation increases after staying 20 minutes in the warm room. This increase becomes smaller when the person stays in the warm room with an acupuncture treatment that decreases body temperature. So that an objective diagnostics on the site may become feasible.

Estimation of Stroke Volume Based on Air Pressure in Air Tube with Pneumatic Pulsatile Ventricular Assist Device (공압식 박동형 심실보조장치에서 공압관 내 공기압에 따른 박출량 추정)

  • Kang, Yu Min;Lee, Jin Hong;Her, Keun;Choi, Seong Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.971-974
    • /
    • 2014
  • A ventricular assist device (VAD) is used for bridge to heart transplantation and heart diseases. Knowing the status of a pneumatic pulsatile VAD when implanting it into the body is important: when the velocity of blood flow through the VAD is slow, a thrombus may occur, and thrombosis can be fatal to a patient. In order to determine the state of a VAD, various sensors need to be implanted. Because this introduces the risk of infection and difficulties with sensor management, we developed a method for estimating the state of a VAD indirectly via the pressure in an air tube that can be measured in vitro. We compared the measured values to in vitro experimental results. The estimated and measured values showed some errors, but the accuracy can be improved by refining the estimation process to minimize the risk of infection.

Comparison of Hemodynamic Energy between Expanded Polytetrafluoroethylene and Dacron Artificial Vessels

  • Lim, Jaekwan;Won, Jong Yun;Ahn, Chi Bum;Kim, Jieon;Kim, Hee Jung;Jung, Jae Seung
    • Journal of Chest Surgery
    • /
    • v.54 no.2
    • /
    • pp.81-87
    • /
    • 2021
  • Background: Artificial grafts such as polyethylene terephthalate (Dacron) and expanded polytetrafluoroethylene (ePTFE) are used for various cardiovascular surgical procedures. The compliance properties of prosthetic grafts could affect hemodynamic energy, which can be measured using the energy-equivalent pressure (EEP) and surplus hemodynamic energy (SHE). We investigated changes in the hemodynamic energy of prosthetic grafts. Methods: In a simulation test, the changes in EEP for these grafts were estimated using COMSOL MULTIPHYSICS. The Young modulus, Poisson ratio, and density were used to analyze the grafts' material properties, and pre- and post-graft EEP values were obtained by computing the product of the pressure and velocity. In an in vivo study, Dacron and ePTFE grafts were anastomosed in an end-to-side fashion on the descending thoracic aorta of swine. The pulsatile pump flow was fixed at 2 L/min. Real-time flow and pressure were measured at the distal part of each graft, while clamping the other graft and the descending thoracic aorta. EEP and SHE were calculated and compared. Results: In the simulation test, the mean arterial pressure decreased by 39% for all simulations. EEP decreased by 42% for both grafts, and by around 55% for the native blood vessels after grafting. The in vivo test showed no significant difference between both grafts in terms of EEP and SHE. Conclusion: The post-graft hemodynamic energy was not different between the Dacron and ePTFE grafts. Artificial grafts are less compliant than native blood vessels; however, they can deliver pulsatile blood flow and hemodynamic energy without any significant energy loss.

True Aneurysms of the Extracranial Carotid Artery : An Evaluation of Two "Giant Aneurysms" and the Current Literature

  • Altun, Gokalp;Pulathan, Zerrin;Hemsinli, Dogus
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.282-286
    • /
    • 2018
  • True extracranial carotid artery aneurysms (ECCAs) are uncommon. Atherosclerosis is the most common etiological factor. Neck pain, a pulsatile mass and murmur at auscultation are the most common symptoms. ECCAs may exhibit severe clinical manifestations due to complications. Cases of rupture can be fatal. There is a risk of distal embolization and stroke in thrombosed cases. We discuss two cases of enlarged ECCA treated surgically in the light of the most recent literature.

Hemorheology and Cardiovascular Disease

  • Cho, Young-I.;Kensey, Kenneth R.
    • 순환기질환의공학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.3-18
    • /
    • 2002
  • Hemorheology plays an important role in atherosclerosis. Hemorheologic properties of blood include whole blood viscosity, plasma viscosity, hemaocrit, RBC deformability and aggregation, and fibrinogen concentration in plasma. Blood flow is determine by three parameters (pressure, lumen diameter, and whole blood viscosity), whole blood viscosity is one of the key physiological variables. However, the significance of whole blood viscosity has not yet not been fully appreciated. Whole blood viscosity has a unique property, non-Newtonian shear-thinning characteristics, which is primarily due to the presence of RBCs. Hence, RBC deformability and aggregation directly affect the magnitude of blood viscosity, and any factors or diseases affecting RBC characteristics influence blood viscosity. Therefore, on can see that whole blood viscosity is the causal mechanism by which traditional risk factors such as hypertension, hyperlipidemia, smoking, exercise, obesity, age, and gender are related to atherogenesis. In this regard, we included whole blood viscosity in the three key determinants of injurious pulsatile flow that results in mechanical injury and protective adaptation in the arterial system. Because whole blood viscosity is a potential predictor of cardiovascular diseases, it should be measured in routine cardiovascular profiles. Incorporating whole blood viscosity measurements into a standard clinical protocol could improve our ability to identify patients at risk for cardiovascular disease and its complications.

  • PDF

NUMERICAL STUDY ON THE BLOOD FLOW CHARACTERISTICS OF STENOSED AND BIFURCATED BLOOD VESSELS WITH A PHASE ANGLE CHANGE OF A PERIODIC ACCELERATION (주기 가속도 위상변화에 따른 협착 및 분지 혈관의 혈류 특성에 대한 수치해석적 연구)

  • Ro, K.C.;Cho, S.W.;Lee, S.H.;Ryou, H.S.
    • Journal of computational fluids engineering
    • /
    • v.13 no.3
    • /
    • pp.44-50
    • /
    • 2008
  • The present study is carried out in order to investigate the effect of the periodic acceleration in the stenosed and bifurcated blood vessels. The blood flow and wall shear stress are changed under body movement or acceleration variation. Numerical studies are performed for various periodic acceleration phase angles, bifurcation angles and section area ratios of inlet and outlet. It is found that blood flow and wall shear stress are changed about ${\pm}20%$ and ${\pm}24%$ as acceleration phase angle variation with the same periodic frequency. also wall shear stress and blood flow rate are decreased as bifurcation angle increased.

LUMPED PARAMETER MODELS OF CARDIOVASCULAR CIRCULATION IN NORMAL AND ARRHYTHMIA CASES

  • Jung, Eun-Ok;Lee, Wan-Ho
    • Journal of the Korean Mathematical Society
    • /
    • v.43 no.4
    • /
    • pp.885-897
    • /
    • 2006
  • A new mathematical model of pumping heart coupled to lumped compartments of blood circulation is presented. This lumped pulsatile cardiovascular model consists of eight compartments of the body that include pumping heart, the systemic circulation, and the pulmonary circulation. The governing equations for the pressure and volume in each vascular compartment are derived from the following equations: Ohm's law, conservation of volume, and the definition of compliances. The pumping heart is modeled by the time-dependent linear curves of compliances in the heart. We show that the numerical results in normal case are in agreement with corresponding data found in the literature. We extend the developed lumped model of circulation in normal case into a specific model for arrhythmia. These models provide valuable tools in examining and understanding cardiovascular diseases.

In Situ Saphenous Vein Arterial Bypass - A case report - (자연위치의 복재정맥을 이용한 하지동맥 우회술 1례 보)

  • Lee, Hong-Seop;Park, Guk-Yang;Kim, Chang-Ho
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.187-190
    • /
    • 1987
  • The Saphenous vein is still the graft of choice for bypass of small calibered peripheral arteries, and many recent studies revealed that the "In Situ" technique had higher rate of long term patency than the conventional "reversed" one. A 71-year-old male who had atherosclerotic obstruction in the superficial femoral and popliteal trifurcation underwent In Situ saphenous vein arterial bypass. The saphenous vein is exposed by a long medial skin incision over the course of the vein. All branches of vein are ligated. A olive-tipped metal needle is introduced into the vein from above and everts the valves. The patient has been followed for 2 months after operation. The graft remained pulsatile and the gangrenous areas on the toe proceeded to heal. We think In situ vein bypass offers an excellent and safe method of revascularization of the arterial occlusion below the knee although it is technically demanding and the time consuming. time consuming.

  • PDF

A study of blood disturbance by an eccentric stenosis under pulsatile flow using ultrasound imaging (초음파 영상을 이용한 박동흐름하의 편심협착에 의한 혈류 교란 연구)

  • Paeng Dong-Guk;Choi Min Joo
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.179-182
    • /
    • 2004
  • 혈관의 협착으로 인만 혈류의 교란과 그로 인한 초음파 반향의 영향을 튜브에 편심 협착 (eccentric stenosis)을 부착하고 돼지 혈액을 이용해 실험실에서 연구했다. 상용화된 GE LOGIQ 700 Expert 시스템과 M12L 의 선형 트랜스듀서를 이용해 B-모드 영상을 얻은 후 편심 협착 상류 지점과 하류 지점의 초음파 영상을 비교하여 분석하였다. 분당 20 회와 40 회의 박동율과 혈류속도를 바꿔가며 혈류의 교란에 따른 혈액에서의 초음파 영상을 분석한 결과, 편심 협착으로 인한 혈류의 교란으로 적혈구 응집현상이 달라져 복잡한 초음파 반향 분포가 형성되었다. 비침습적 실시간 초음파 영상은 편심 협착으로 인한 혈류의 교란과 그로 인한 혈액의 적혈구 응집 현상을 이해하고 연구하는데 도움이 된다.

  • PDF

Arteriovenous Malformation of the Scalp : Efficacy of Computed Tomography Angiography

  • Moon, Kang-Seok;Yoon, Seok-Mann;Shim, Jai-Joon;Yun, Il-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.5
    • /
    • pp.396-398
    • /
    • 2005
  • We report a rare case of scalp arteriovenous malformation[AVM]. A 55-year-old woman presented with a pulsatile palpable mass on her left temporo-parietal scalp. She complained of insomnia because of bruit, which was audible when she lay on her left side. Computed tomography angiography[CTA] for the scalp vessel showed AVM on the left temporo-parietal region. Multiple enlarged arteries, such as the superficial temporal artery, posterior auricular artery, and occipital artery, were directly connected to the elongated dilated superficial temporal vein. Digital subtraction angiography also showed similar results. Fistulous portions were clearly delineated on both modalities. Surgical excision of the malformations, including feeding arteries and the draining vein, resulted in immediate relief of the symptoms. Usefulness of CTA in the diagnosis of vascular lesions on the scalp was emphasized.