• Title/Summary/Keyword: pull-Out 실험

Search Result 166, Processing Time 0.029 seconds

Experimental study on pullout performance of structural fiber embedded in cement composites according to fineness modulus of fine aggregate (시멘트 복합체에 근입된 숏크리트용 구조 섬유의 잔골재 조립률에 따른 인발성능 비교)

  • Choi, Chang-Soon;Lee, Sang-Don;Song, Ki-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.4
    • /
    • pp.317-326
    • /
    • 2022
  • This research performed single fiber pull-out test to evaluate the effect between fineness modulus of cement composites and the fiber bond performance (bond strength and pull-out energy). A synthetic fiber (polypropylene) and a steel fiber (hooked ends type) were inserted in the middle of dog bone shape specimens which were designed with fine aggregates of F. M. 1.96, 2.69, 3.43. The experiment results showed bond strength and pullout energy of synthetic fiber are improved as fineness modulus of cement composites increases. It is considered that the frictional resistance between synthetic fiber and cement composite increases as fineness modulus of cement composite increases and consume more energy while pull out the fiber from cement composite. However bond performance of steel fiber which resist pull out by mechanical behavior is less effected on fineness modulus of cement composite. It is considered that the mechanical fixedness of hooked ends exerts a greater effect on the pullout resistance than the frictional resistance between the cement composite and the steel fiber so F. M. of fine aggregate has a relatively small effect on the pullout resistance with the steel fiber.

A Study on the Pull-out Strength of Bond Type Anchors (부착식 앵커의 인발강도에 관한 연구)

  • Seo, Seong Yeon
    • Journal of Korean Society of Steel Construction
    • /
    • v.30 no.2
    • /
    • pp.105-114
    • /
    • 2018
  • The use of post installed anchors with bond type has lately been increasing when it is necessary to repair, reinforce, or remodel structures. This method provides flexibility and simplicity for construction of structural members that require adhering or fixing. Meanwhile, strength evaluation of anchors with expansion type among post-installed anchors systems has nearly reached setting up stage like design code through continual experimental studies for the last ten years, but analyses or experimental studies on anchor system with bond type are not yet sufficient. Accordingly, the designers and builders of korea depend on foreign design codes since there are no exact domestic design code they could credit. In this study, the objectives are investigating the effects on pull-out strength of resin anchors embedded into plain concrete by pull-out experiment of resin anchors with variables such as anchor diameter, anchor interval, embedment depth and edge distance.

Pull-out Bond Characteristics of Reinforced Concrete Members (철근콘크리트 부재의 뽐힘 부착특성 연구)

  • 오병환
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.3
    • /
    • pp.113-121
    • /
    • 1992
  • 본 논문에서는 철근콘크리트 부재의 뽐힘부착거동을 규명하기 위하여 일련의 포괄적인 실험 및 이론 연구를 수행하였다. 실험의 주요변수는 콘크리트의 압축강도, 철근간격 및 덮개, 그리고 철근의 부착길이 등을 선정하였다. 본 연구결과 철근 콘크리트의 부착강도는 뿐만아니라 부착길이, 철근의 덮개 등에 따라 큰 영향을 받는 것으로 나타났으며, 본 연구에서는 이들의 영향을 정량적으로 도출하였다. 또한, 본 연구에서는 철근콘크리트의 부착강도식을 새롭게 제안하였으며, 부착응력-슬립관계식도 유도하여 제시하였다.

Development of the Soil Bioengineering Techniques for Restoring of Degraded Forest Area (V) - Pull-out Resistance Characteristics of Shrubs' roots - (산림훼손지복원을 위한 Soil Bioengineering 기술개발(V) - 관목류의 뿌리인발저항 특성 -)

  • Cha, Du-Song;Oh, Jae-Heun;Ji, Byoung-Yun;Cho, Koo-Hyun;Lee, Hae-Joo
    • Journal of Forest and Environmental Science
    • /
    • v.24 no.2
    • /
    • pp.111-118
    • /
    • 2008
  • Pull-out resistance tests of root were carried out for 7 shrub species which are mainly used greening of deteriorated forest slope. Mean pull-out resistance forces of Aralia elata, Salix koreensis and Stephanandra incisa were 37.26 kgf, 34.56 kgf and 26.00 kgf, respectively. The pull-out resistances were high as collar diameter and volume of the root increased. Correlations between root collar diameter and root volume were high in Rubus crataegifolius, but on the other hand, the correlation was lowest in Zanthoxylum schinifolium. There were significant differences in pull-out resistance by root collar diameters, and the difference of pull-out resistance by species showed only below 20 ml root volume.

  • PDF

Development of Tie-Bar Installation Method for Concrete Pavement Widening (콘크리트포장 확장부 타이바 설치방법의 개발)

  • Hwang In-Kyu;Yang Sung-Chul;Jeong Jin-Hoon;Yoo Tae-Seok
    • International Journal of Highway Engineering
    • /
    • v.8 no.1 s.27
    • /
    • pp.33-43
    • /
    • 2006
  • Pull-out strength of tie-bin used in pavement construction is not an issue because those are embedded in newly placed concrete slabs. However, sufficient pull-out strength should be secured in widening constructions because, in case, the tie-bars are inserted into drilled holes of the existing slabs with liquid filler. Insufficient pull-out strength will result in lowered load transfer efficiency between adjacent slabs in addition to poor serviceability and durability due to joint widening. The pull-out strength of the tie-bars installed by current method is evaluated and improved methods are proposed. The field pull-out strength obtained by the current method was only 42.7% of required strength. Its first counterproposal is using to insert the liquid filler into drilled holes and stoppers to prevent it from flowing out of the holes. However, this method was not judged to secure desired level of quality control. The second counterproposal which substitutes the existing type of the tie-bars by SL anchor bolts was judged to secure sufficient pull out-strength in addition to the quality control and constructibility.

  • PDF

A study on pull-out behaviours of shotcrete steel fibers according to different shapes (숏크리트 강섬유 형상에 따른 인발 거동에 대한 연구)

  • Kim, Sang-Hwan;Kim, Ji-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.1
    • /
    • pp.71-82
    • /
    • 2011
  • This paper presents the tensile strength of shotcrete steel fibers depending on the shape of steel fiber. The experimental and numerical analyses are performed in this study. In experimental study, a series of laboratory pullout tests are carried out by changing both the angle and the length of the embedded steel fiber according to the corresponding type of steel fiber in order to derive the optimal type of steel fiber. Results obtained from the experimental work are evaluated and compared with the numerical analysis results. The results clearly show that the pull-out strength of the steel fiber are increased with increasing the hook angle and embedded angle of steel fiber. It is also found that the pull-out strength of the steel fiber is larger in case of the short steel fiber body length.

Pull-out Capacity of Cast-in-place Anchor for Construction of Precast Concrete Segment Arch (프리캐스트 콘크리트 패널 분절 아치 시공을 위한 선설치 앵커의 인발 강도 평가)

  • Ahn, Jin-Hee;Yim, Hong Jae;Bang, Jin Soo;Jeon, Seok Hyeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.94-102
    • /
    • 2020
  • Precast concrete segment arch system has an economic and construct ability that combined with advantage of precast concrete and arch behavior. A precast concrete segment arch system with outrigger is consisted of segmented precast panels, a steel outrigger rib, and V-strip to connect precast panels with a steel outrigger rib and cast-in-place anchors in precast panels to connect V-strip should have sufficient pull-out capacity to form its arch shape by site lifting for assembled precast panels and outriggers. However, it is difficult to secure its embedment depth due to the relatively shallow thickness of precast panel. It can be also occurred that flexure deformation of precast panels caused by its pull-out behaviors. In this study, pull-out capacity of cast-in-place anchor was examined for construction of precast concrete segment arch system with outriggers. Therefore, a total of 24 precast panel specimens were fabricated to examine pull-out capacities of cast-in-place anchor in precast panels, and installation depth of anchors, diameter of anchors and wire mesh effects for the precast panel were examined. From this pull-out tests, its pull-out capacities and failure modes were evaluated and the type of the cast-in-place anchor applicable to the precast concrete segment panel arch system with outriggers was determined from comparison of the design specification values.

Pull-out Test of Steel Pipe Pile Reinforced with Hollow Steel Plate Shear Connectors (유공강판 전단연결재로 보강된 강관말뚝 머리의 인발실험)

  • Lee, Kyoung-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.285-291
    • /
    • 2016
  • The purpose of this study was to evaluate the structural capacity of steel pipe pile specimens reinforced with hollow steel plate shear connectors by pull-out test. Compressive strength testing of concrete was conducted and yield forces, tensile strengths and elongation ratios of re-bars and hollow steel plate were investigated. A 2,000kN capacity UTM was used for the pull-out test with 0.01mm/sec velocity by displacement control method. Strain gauges were installed at the center of re-bars and hollow steel plates and LVDTs were also installed to measure the relative displacement between the loading plate and in-filled concrete pile specimens. The yield forces of the steel pipe pile specimens reinforced with hollow steel plate shear connectors were increased 1.44-fold and 1.53-fold compared to that of a control specimen, respectively. Limited state forces of steel pipe pile specimens reinforced with hollow steel plate shear connectors were increased 1.23-fold and 1.29-fold compared to that of a control specimen, respectively. Yield state displacement and limited state displacement of steel pipe pile specimens reinforced with hollow steel plate shear connector were decreased 0.61-fold and 0.42-fold compared to that of a control specimen, respectively.

Experimental Study of Bond Stress-Slip Behavior under Repeated Loading (반복하중 하에서 부착응력-슬립 거동 실험적 연구)

  • 오병환;김세훈;김지상;신용석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.215-218
    • /
    • 2003
  • To analyze a bond stress-slip behavior between a reinforcing bar and concrete under repeated loading, pull-out fatigue test was performed. Major variables were repeated stress levels and cycle numbers. Test specimen was taken repeated constant amplitude loading before it was fractured by pull-out test. Increments of bond strength and slip according to repeated stress level and cycle numbers were analyzed. On the basis of test results, Local bond stress-slip relationship under repeated loading were formulated

  • PDF

Performance test of Chemical Anchor Bolts for Concrete Repair (콘크리트보수용 접착제를 이용한 Anchor Bolt의 인발지지력 산정에 관한 실험적 연구)

  • Kim, Yon-Gon
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.2
    • /
    • pp.85-91
    • /
    • 2002
  • A research on the performance of retrofit anchors was conducted using adhesives for rehabilitation. From the pull-out tests of the chemical anchors, the effect of the hole diameter, spacer, temperature, moisture, embedment depth, and aging time were investigated. The spacer did not directly increased the pull-out load hilt increased post-yielding resistance therefore the ductility of the retrofit anchors. When the hole was cleaned and dried after the immersion, the pull-out load was greatly increased compared to the wet hole. A design equation was unposed depending on the embedment depth of the anchor bolt.