• 제목/요약/키워드: public wastewater treatment plant

검색결과 51건 처리시간 0.024초

공주 축산폐수공공처리장에서의 바이오가스-마이크로터빈 분산발전시스템 개발 (Biogas-Microturbine Distributed Generation Developement at Gong-Ju Public Livestock Wastewater Treatment Facility)

  • 박정극;허광범;이기철;강호;임상규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.229-234
    • /
    • 2008
  • Korea Electric Power Corporation (KEPCO) has started the nation's first biogas-microturbine project in the city of Gongju as an effort to encourage the utilization of wasted biogas containing useful energy source in the form of $CH_4$. The goal of the project is to set up the biogas microturbine co-generation system for utilizing biogas as an energy source and improving the economics of the wastewater treatment plant. Wastewater treatment processes were investigated in depth to find improvement possibility. Changes in internal recirculation ratio and pre-treatment degree are needed to optimize plant operation and biogas production. Biogas pre-treatment system satisfies Capstone's fuel condition requirement with the test result of 99.9% and 90.2% of hydrogen sulphide and ammonia is removal performance. Installation of microturbine and manufacture of heat exchanger to warm anaerobic digester has been done successfully. Expected economic profit produced by the system is coming from energy saving including electricity 115,871kWh/year and heat contained in exhaust gas 579GJ/year.

  • PDF

$A_2O$ 공법 처리장의 Bioindicator (Bioindicator at $A_2O$ Wastewater Treatment Plant)

  • 이찬형;문경숙
    • 한국환경보건학회지
    • /
    • 제31권1호
    • /
    • pp.55-60
    • /
    • 2005
  • The occurrence and abundance of protozoa at advanced wastewater treatment plant were compared with operating parameters and effluent quality using statistical procedures. In correlation analysis between the distribution of protozoa and operating parameters, the distribution of protozoa was showed the operating condition of plant. Regression analysis between the distribution of protozoa and effluent quality up to 7 days, showed the R-square values of most regression equation were more than 0.6 and constant was higher than slope and could indicate effluent quality from sampling day to 7 days. Once enough data concerning protozoa, operating parameters and effluent has been gathered, the operator has a valuable tool for predicting plant performance and near-future effluent quality based on microscopic examination. Plant operator manipulates operating conditions if he knows near-future data of effluent is deteriorating. Perhaps more importantly it can be used to actually control the plant to adjust the operating conditions to obtain the protozoal populations that have been shown to provide the best effluent quality.

COBie 기반 하수처리시설 유지관리시스템 구축 (A Study on the Feasibility of COBie to the Wastewater Treatment Plant)

  • 최재호;엄동용
    • 대한토목학회논문집
    • /
    • 제34권1호
    • /
    • pp.273-283
    • /
    • 2014
  • BIM 기술의 하나인 COBie 포맷의 출현으로 설계와 시공단계에서 발생한 정보가 운영단계로 자동 전송이 가능해지면서 BIM을 중심으로 하는 유지관리시스템 개발 프로세스가 건축물을 중심으로 실험되고 있다. 하지만 BIM 시장 확대가 예상되는 현재 시점에서 건축물을 포함한 토목시설과 산업시설에서의 COBie 활용성에 대한 검토가 선행되어야 할 필요가 있다. 본 연구는 "공공하수도시설 운영 관리 업무지침"과 현재 운영중인 하수처리시설을 대상으로 진행하였고 후자는 업무지침의 결과를 검증하고 보충하는데 의의가 있다. 본 연구에서 도출된 결론은 세 가지로 요약된다. (1) 자산 모델링 방법인 COBie는 시운전 정보를 포함하기에는 충분하지 않으며, (2) 하수처리시설 모델링에 필요한 IFC 개발과 패밀리 구축이 반드시 필요하다. 그리고 (3) 현재의 운영관리시스템에 적합하게 설계된 COBie 모델은 산업시설분야의 COBie 포맷 타당성을 높여 줄 것이다. 본 연구 결과는 산업시설에서의 COBie 적용을 위한 기초 자료로 이용될 것으로 기대된다.

BIM 기반 하수처리시설 유지관리 프로토타입 시스템 개발 (Development of BIM based Maintenance Management Prototype System for Wastewater Treatment Plant)

  • 엄동용;최재호
    • 대한토목학회논문집
    • /
    • 제34권6호
    • /
    • pp.1901-1910
    • /
    • 2014
  • 현재 국내외 BIM을 도입한 사회기반시설 적용 사례는 BIM 시각화를 기반으로 하는 설계 및 시공단계에 제한되며 효율적 운영을 위한 설계, 시공 정보 활용 방안에 대한 연구는 매우 미미하다. 본 연구는 최근 국내 경제 발전에 많은 기여를 하고 있는 산업설비군 중 운영 및 유지관리 능력 향상이 필요한 하수처리시설을 대상으로 BIM 기반 통합 유지관리 프로토타입 시스템을 개발하였다. 본 연구에 사용된 주요 연구 방법으로는 시스템 개발 순서에 따라 진행하였으며, 최종적으로 개발된 프로토타입 시스템의 현업 적용 가능성을 판단하기 위하여 4가지의 대표적 유지관리 시나리오를 제안하고 산출물을 통해서 문제 해결이 가능함을 보여준다. 최근 상하수도시설의 자산관리 개념 도입 노력과 유역기반 운영 및 유지관리의 정책 및 제도 적 변화, 그리고 국내 상하수도 기술력의 해외시장 진출 필요에 따른 운영 및 유지관리 능력 고도화를 위해 본 연구결과가 일조할 수 있기를 기대해 본다.

대구시 산업단지 환경기초시설의 악취발생 특성 (Emission Characteristics of Odor Compounds from Fundamental Environmental Facilities in an Industrial Complex Area in Daegu City)

  • 이찬형;전현숙;신명철;김은덕;장윤재;권병윤;송희봉
    • 한국환경보건학회지
    • /
    • 제42권4호
    • /
    • pp.246-254
    • /
    • 2016
  • Objectives: This study evaluated the odor emission characteristics from fundamental environmental facilities at an industrial complex area in Daegu City. Methods: The odor samples were collected from May 2015 to January 2016 and were analyzed for specified offensive odor substances. The odor quotient and the odor contribution was calculated. Results: Ammonia was detected in all samples monitoring specified odor compounds, followed by hydrogen sulfide and acetaldehyde. According to contribution analysis, hydrogen sulfide shows the highest contribution in all facilities. At wastewater treatment plants A and B and sewage treatment plant F, it was followed by acetaldehyde. At wastewater treatment plant C, it was followed by imethyl sulfide. Conclusion: The major component of odor can be determined by evaluating the degree of contribution to the odor intensity rather than the concentration of the individual odor components. To increase the effectiveness of odor reduction, policies focused on materials with a high odor contribution are needed rather than focusing on high-concentration odor compounds.

Impact of Pig Slurry from WangGoong Farm Cluster on Water Quality of the Iksan Stream

  • Choi, Hong-Lim;Suresh, A.;Babu, T.;Mansyur, Mansyur
    • Journal of Animal Science and Technology
    • /
    • 제53권6호
    • /
    • pp.549-561
    • /
    • 2011
  • Livestock wastewater is being discharged without treatment from Hasen's pig farm cluster in WangGoong (WG) area into the Iksan Stream, eventually flowing into the ManGyung (MG) at the upstream junction. Although it is well known that before discharge, wastewater must satisfy the pig slurry discharge standards; because of ongoing remodeling, proper treatment is not being performed. According to public records, wastewater from the WG pig farm cluster is responsible for 3.6% of MG River pollution and 2.0% of the SaeManGuem (SMG) Reservoir pollution. As a result, upstream water treatment quality has become primary concern for development of the SMG project. All physicochemical constituents and pathogenic microbes, such as chemical oxygen demand ($COD_{Cr}$), biochemical oxygen demand ($BOD_5$), total suspended solids (TSS), total nitrogen (TN), total phosphorous (TP), fecal coliforms, Escherichia coli and Salmonella at the effluent of WG Plant (S-1) exceed the effluent standards. This is mainly due to insufficient wastewater treatment: the WG Plant is under renovation to increase water purification efficiency. By comparing the water quality at the S-7 junction, where the the Iksan Stream (pig farms) and the Wanggoong Stream (no pig farms) merge, it is clear that farming facilities and improper treatment can critically affect surrounding water quality. While it is clear throughout this study that the level of all physicochemical parameters and pathogenic microbes along the Stream decreased due to sedimentation, biodegradation and/or dilution. An alarming problem was discovered: the existence of pathogenic microbe count(E coli, Salmonella) in the lagoon wastewater and the stream water. Not only were high concentrations of these pathogens themselves found, but the potential existence of more serious pathogens could rise to more dangerous conditions.

공공하수도 관리대행 성과평가 지표별 가중치분석을 통한 우선순위에 대한 연구 (A study on the priorities through weight analysis for each index of performance evaluation of public sewage operation agency)

  • 위미경;박철휘
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.495-502
    • /
    • 2020
  • The 37 indicators for performance evaluation of public sewage management agencies are divided into four major categories (agency manpower management ability, wastewater treatment plant operation and management, sludge and water reuse, service quality) in the first stage, and the necessity and score acquisition for the detailed indicators by each major category in the second stages. Priority was investigated through the Analytic Hierarchy Process (AHP) analysis technique for ease and relevance of company efforts. Also, based on the results of this analysis, integrated type weighting and relative importance were analyzed. As a result of the analysis, the weight and relative importance of the first stage classification were in the order of wastewater treatment plant operation and maintenance, operation agency manpower management ability, sludge and water reuse, and service quality. As a result of analyzing the weights and priorities of the detailed performance indicators in the second stage, it was found that operator's career years, the percentage of certification holding rate in operators, compliance with the effluent water quality standards, training times for operators, and efforts to manage hazardous chemicals were important. Some of the indicators of operation agency performance evaluation may include indicators in which the performance of the company's efforts is underestimated or overestimated. In order to improve this, it is necessary to give weights in consideration of the necessity of the indicator, the relevance of the company's efforts, and the ease of obtaining scores.

회귀분석을 이용한 반월 공단배수의 생태독성 원인물질 조사 (Investigation of Eco-toxicological Substances in Banwol Industrial Drainages using the Regression Analysis)

  • 김요용;우정식;황선민;김문정
    • 한국물환경학회지
    • /
    • 제28권3호
    • /
    • pp.467-472
    • /
    • 2012
  • In this study, water quality and acute toxicity using Daphnia magna were analyzed to investigate the eco-toxicological substances identified as statistical analysis and propose a management plan for the effluent of Banwol industrial complex, Ansan, Gyeonggi-do. Cu, Zn, F, Mn concentrations in the effluent far exceeded the US standards to protect the aquatic ecosystem and eco-toxicity values were 5 ~ 22 TU. However, concentrations of heavy metals significantly decreased after Ansan public wastewater treatment plant operating a biological treatment and toxicity values were 0 TU. Zn, Cr, F and Cu in the effluent showed very strong and strong positive correlations with eco-toxicity values, respectively. Regression analysis resulted in an equation between toxicity and Zn, TU = $4.884{\times}Zn$ (mg/L) -0.391 showing Zn concentration should be managed less than 0.285 mg/L to keep the eco-toxicity (TU) less than 1.

경상북도내 주요 하폐수처리장 방류수의 미량유해물질 배출특성 (The Discharge Characteristic of Micropollutants in Effluents from Major Sewage and Wastewater Treatment Facilities in GyeongSangBukdo)

  • 서상욱;배헌균
    • 한국환경과학회지
    • /
    • 제20권6호
    • /
    • pp.673-678
    • /
    • 2011
  • Water samples from several wastewater treatment plants and two industry drains in Gyeongsangbukdo were investigated for concentration levels of micropollutants. Samples were taken totally four times from May to November of 2008 and tested for seven factors including pesticide, 1,4-Dioxane and Perchlorate which had been big issues for Nakdong river because of their contaminations. As results, 2,4-D, Alachlor, and BEHA were not detected while BEHP was detected at some sampling sites. 1,4-Dioxane and Perchlorate were also detected in wide ranges from several sampling sites. Therefore, continuous supervising and monitoring systems needed to be invested for proper management for micropollutants since those micropollutants could affect human health and aquatic system with low concentration levels.

Integrated Eco-Engineering Design for Sustainable Management of Fecal Sludge and Domestic Wastewater

  • Koottatep, Thammarat;Polprasert, Chongrak;Laugesen, Carsten H.
    • 한국습지학회지
    • /
    • 제9권1호
    • /
    • pp.69-78
    • /
    • 2007
  • Constructed wetlands and other aquatic systems have been successfully used for waste and wastewater treatment in either temperate or tropical regions. To treat waste or wastewater in a sustainable manner, the integrated eco-engineering designs are explained in this paper with 2 case studies: (i) a combination of vertical-flow constructed wetland (CW) with plant irrigation systemfor fecal sludge management and (ii) integrated CW units with landscaping at full-scale application for domestic wastewater treatment. The pilot-scale study of fecal sludge management employed 3 vertical-flow CW units, each with a dimension of $5{\times}5{\times}0.65m$ (width ${\times}$ length ${\times}$ media depth) and planted with cattails (Typha augustifolia). At the solid loading rate of 250 kg total solids (TS)/$m^2.yr$ and a 6-day percolate impoundment, the CW system could achieve chemical oxygen demand (COD), TS and total Kjeldahl nitrogen (TKN) removal efficiencies in the range of 80 - 96%. The accumulated sludge layers of about 80 - 90 cm was found at the CW bed surface after operating the CW units for 7 years, but no clogging problem has been observed. The CW percolate was applied to 16 irrigation Sunflower plant (Helianthus annuus) plots, each with a dimension of $4.5{\times}4.5m$ ($width{\times}length$). In the study, the CW percolate were fed to the treatment plots at the application rate of 7.5 mm/day but the percolate was mixed with tap water at different ratio of 20%, 80% and 100%. Based on a 1-year data of 3-crop plantation were experimented, the contents of Zn, Mn and Cu in soil of the experimental plots were found to increase with increasing in CW percolate ratios. The highest plant biomass yield and oil content of 1,000 kg/ha and 35%, respectively, were obtained from the plots fed with 20% or 50% of the CW percolate, whereas no accumulation of heavy metals in the plant tissues (i.e. leaves, stems and flowers) of the sunflower is found. In addition to the pilot-scale and field experiments, a case study of the integrated CW systems for wastewater treatment at Phi Phi Island (a Tsunami-hit area), Krabi province, Thailand is illustrated. The $5,200-m^2$ CW systems on Phi Phi Island are not only for treatment of $400m^3/day$ wastewater from hotels, households or other domestic activities, but also incorporating public consultation in the design processes, resulting in introducing the aesthetic landscaping as well as reusing of the treated effluent for irrigating green areas on the Island.

  • PDF