• 제목/요약/키워드: prototype tests

검색결과 473건 처리시간 0.029초

Effect of countermeasures on the galloping instability of a long-span suspension footbridge

  • Ma, Ruwei;Zhou, Qiang;Li, Mingshui
    • Wind and Structures
    • /
    • 제30권5호
    • /
    • pp.499-509
    • /
    • 2020
  • The aeroelastic stability of a long-span suspension footbridge with a bluff deck (prototype section) was examined through static and dynamic wind tunnel tests using a 1:10 scale sectional model of the main girder, and the corresponding aerodynamic countermeasures were proposed in order to improve the stability. First, dynamic tests of the prototype sectional model in vertical and torsional motions were carried out at three attack angles (α = 3°, 0°, -3°). The results show that the galloping instability of the sectional model occurs at α = 3° and 0°, an observation that has never been made before. Then, the various aerodynamic countermeasures were examined through the dynamic model tests. It was found that the openings set on the vertical web of the prototype section (web-opening section) mitigate the galloping completely for all three attack angles. Finally, static tests of both the prototype and web-opening sectional models were performed to obtain the aerodynamic coefficients, which were further used to investigate the galloping mechanism by applying the Den Hartog criterion. The total damping of the prototype and web-opening models were obtained with consideration of the structural and aerodynamic damping. The total damping of the prototype model was negative for α = 0° to 7°, with the minimum value being -1.07%, suggesting the occurrence of galloping, while that of the web-opening model was positive for all investigated attack angles of α = -12° to 12°.

철근콘크리트 축소모형의 유사동적실험과 진동대 실험을 위한 상사법칙 연구 (A Study on Similitude Law for Pseudodynamic Tests and Shaking Table Tests on Small-scale R/C Models)

  • 양희관;서주원;조남소;장승필
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.545-552
    • /
    • 2006
  • Small-scale models have been frequently used for seismic performance tests because of limited testing facilities and economic reasons. However, there are not also enough studies on similitude law for analogizing prototype structures accurately with small-scale models, although conventional similitude law based on geometry similitude is not well consistent in their inelastic seismic behaviors. When fabricating prototype and small-scale model of reinforced concrete structures by using the same material, added mass is demanded from a volumetric change and scale factor could be limited due to aggregate size. Therefore, it is desirable to use different materials for small-scale model. In our recent study, a modified similitude law was derived depending on geometric scale factor, equivalent modulus ratio and ultimate strain ratio. And quasi-static and pseudo-dynamic tests on the specimens are carried out using constant and variable modulus ratios, and correlation between prototype and small-scale model is investigated based on their test results. In this study, tests on scaled model of different concrete compressive strength aye carried out. In shaking table tests, added mass can not be varied. Thus, constant added mass on expected maximum displacement was applied and the validity was verified in shaking table tests. And shaking table tests on non-artificial mass model is carried out to settle a limitation of acceleration and the validity was verified in shanking table tests.

  • PDF

1-g 진동대 모형시험을 위한 상사법칙의 적용성 평가 (Applicability of Similitude Laws for 1-g Shaking Table Tests)

  • 황재익;김성렬;김명모
    • 한국지반공학회논문집
    • /
    • 제20권3호
    • /
    • pp.141-150
    • /
    • 2004
  • 1995년 고베지진에 의해 피해를 입었던 중력식 안벽구조물과 잔교식 안벽구조물의 동적 거동을 재현하고, 분석하기 위하여 소규모 1-g 진동대 모형시험을 수행하였다. 1989년 Iai가 제안한 상사법칙을 이용하여 진동대 모형시험 결과를 원형크기의 것으로 환산하여 현장계측 결과와 비교하였다. 그 결과, 중력식 안벽구조물의 변위는 현장계측 결과의 약 1/3 정도 발생하였고, 벽체의 변형 형상은 원형과 유사하였다. 잔교식 안벽구조물의 변위는 현장계측 결과의 약 2/3 가 발생하였고, 말뚝에 발생하는 최대모멘트의 위치와 원형말뚝의 파괴위치는 잘 일치하였다.

Investigation of water length effects on the modal behavior of a prototype arch dam using operational and analytical modal analyses

  • Sevim, Baris;Bayraktar, Alemdar;Altunisik, Ahmet Can
    • Structural Engineering and Mechanics
    • /
    • 제37권6호
    • /
    • pp.593-615
    • /
    • 2011
  • This study determines the water length effects on the modal behavior of a prototype arch dam using Operational and Analytical Modal Analyses. Achievement of this purpose involves construction of a prototype arch dam-reservoir-foundation model under laboratory conditions. In the model, reservoir length was taken to be as much as three times the dam height. To determine the experimental dynamic characteristics of the arch dam using Operational Modal Analysis, ambient vibration tests were implemented for empty reservoir and three different reservoir water lengths. In the ambient vibration tests, the dam was vibrated by natural excitations provided from small impact effects and the response signals were measured using sensitive accelerometers. Operational Modal Analysis software process signals collected from the ambient vibration tests, and Enhanced Frequency Domain Decomposition and Stochastic Subspace Identification techniques estimated modal parameters of the dams. To validate the experimental results, 3D finite element model of the prototype arch dam was modeled by ANSYS software for empty reservoir and three different reservoir water lengths, and dynamic characteristics of each model were determined analytically. At the end of the study, experimentally and analytically identified dynamic characteristics compared to each other. Also, changes on the natural frequencies along to water length are plotted as graphs. Results suggest that reservoir water complicates the modal behavior of the arch dam significantly.

해양결찰청의 위기상황 가시화 시스템 구축 (Implementing Risk Visualization System of National Maritime Police Agency)

  • 임정빈;구자영
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2000년도 제 25회 정기총회 및 추계학술발표회
    • /
    • pp.45-49
    • /
    • 2000
  • The paper deals with the implementation of prototype Risk Visualization Sytem (RVS). The RVS is one of the sub-system of Risk Management System (RMS) of National Maritime Police Agency in Korea. In this work, prototype RVS was constructed with virtual reality techniques. Using the prototype RVS, we carried out some performance tests for the various environmental conditions at sea. As results from tests, the prototype RVS can provide immersible virtual world. The results gave rise to the user interaction with 3D objects that give realistic reproduction of sear environments. Thus, we found that the prototype RVS should be a immersible visualization system of Risk Management System.

  • PDF

COMPUTATIONAL DURABILITY PREDICTION OF BODY STRUCTURES IN PROTOTYPE VEHICLES

  • Kim, H.-S.;Yim, H.-J.;Kim, C.-B.
    • International Journal of Automotive Technology
    • /
    • 제3권4호
    • /
    • pp.129-135
    • /
    • 2002
  • Durability estimation of a prototype vehicle has traditionally relied heavily on accelerated durability tests using predefined proving grounds or rig tests using a road simulator. By use of those tests, it is very difficult to predict durability failures in actual service environments. This motivated the development of an integrated CAE (Computer Aided Engineering) methodology for the durability estimation of a prototype vehicle in actual service environments. Since expensive computational costs such as computation time and hardware resources are required for a full vehicle simulation in those environments with a very long span of event time, the conventional CAE methodologies have little feasibility. An efficient computational methodology for durability estimations is applied with theoretical developments. The effectiveness of the proposed methodology is shown by the comparison of results of the typical actual service environment such as the city mode with those of the typical accelerated durability test over the Belgian road.

Prototyping an embedded wireless sensor for monitoring reinforced concrete structures

  • Utepov, Yelbek;Khudaibergenov, Olzhas;Kabdush, Yerzhan;Kazkeev, Alizhan
    • Computers and Concrete
    • /
    • 제24권2호
    • /
    • pp.95-102
    • /
    • 2019
  • Current article proposes a cheap prototype of an embedded wireless sensor to monitor concrete structures. The prototype can measure temperature and relative humidity concurrently at a controlled through smartphone time interval. It implements a maturity method to estimate in-place concrete strength, which is considered as an alternative for traditional shock impulse method and compression tests used in Kazakhstan. The prototype was tested and adequately performed in the laboratory and field conditions. Tests aimed to study the effect of internal and ambient temperature and relative humidity on the concrete strength gain. According to test results revealed that all parameters influence the strength gain to some extent. For a better understanding of how strongly parameters influence the strength as well as each other, proposed a multicolored cross-correlation matrix technique. The technique is based on the determination coefficients. It is able to show the value of significance of correlation, its positivity or negativity, as well as the degree of inter-influence of parameters. The prototype testing also recognized the inconvenience of Bluetooth control due to weakness of signal and inability to access several prototypes simultaneously. Therefore, further improvement of the prototype presume to include the replacement of Bluetooth by Narrow Band IoT standard.

Development of a Shower Carrier based on the Needs in Long-term Care Institutions

  • Cho, Deok-Yeon;Ko, Cheol-Woong;Chun, Keyoung-Jin;No, Kon-Woo
    • 대한인간공학회지
    • /
    • 제31권2호
    • /
    • pp.379-388
    • /
    • 2012
  • Objective: This study developed a new shower carrier prototype to reduce caregivers' muscle burden and to increase use convenience by reflecting the needs of domestic long-term care institutions. Background: In the long-term care institutions, one of the ADL(Activities of Daily Life) factors is bathing/showering. Recently, bath/shower-assisting equipment is actively being introduced in care institutions to reduce the caregivers' care cost, but most of the domestic equipment was designed to imitate foreign products and rarely reflected the needs of care institutions. Method: Based on Korean elderly people's body information, the bed size(length: 1,900mm, width: 650mm) was set-up, and a variable headrest with a newly designed headform was developed to provide the comfort for the elderly and convenience for caregivers. To reduce caregivers' muscle burden on transferring and showering activities, a 3-step column lifting module equipped with dual actuators(lowest/highest levels from the ground: 600/1,100mm, Stroke: 500mm) was developed, and the wheelbase parameter(length: 1,250mm, width: 580mm) was defined securing the turn-over safety of the shower carrier. The drivability tests were performed for the prototype and foreign product, and the male and female subject's muscle activities were measured through the tests. Results: The structural stability of the shower carrier prototype was secured by finite element analysis, and the muscle activities of the subjects through the drivability tests largely decreased in the prototype, compared to the foreign product. Conclusion: In this study, a new shower carrier prototype was developed to possibly reduce caregivers' muscle burden and to increase use convenience based on the needs of long-term care institutions. It was expected that the drivability performance of the prototype could be relatively superior to that of the foreign product. Application: The results obtained from the study can be applied for the optimal development of a shower carrier including other equipment to effectively care for the elderly.

SMES용 Cryostat 시제작 및 평가 (I) (Manufacturing and Tests of Cryostat for SMES (I))

  • 조전욱;심기덕;하홍수;김해종;김봉태;성기철;권영길;류강식;고득용
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.117-120
    • /
    • 2001
  • In this paper we present the results of manufacturing and tests of prototype cryostat for micro-SMES. The prototype cryostat with HTS current leads and refrigerator had been designed and manufactured for micro-SMES. The cryostat had been tested the helium boil-off and mechanical stress during transfer and vibration test. These results will be applied to micro-SMES cryostat.

  • PDF

Assembling and Insulation Test of 1MVA Single Phase HTS Transformer for Power Distribution

  • Kim, S. H.;Kim, W. S.;Kim, J. T.;Park, K. D.;H. G. Joo;G. W. Hong;J. H. Han;Lee, S. J.;S. Hahn
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권3호
    • /
    • pp.30-33
    • /
    • 2003
  • 1MVA high temperature superconducting (HTS) transformer with double pancake windings made of BSCCO-2223 HTS tapes was designed and manufactured. And prototype transformer with the same capacity was manufactured also. The each rated voltage of the HTS transformer is 22.9 kV and 6.6 kV. Four parallel BSCCO-2223 HTS tapes were wound in the double pancake windings of low voltage side. In order to distribute the currents equally in each HTS tapes, the three times transposition was performed between the double pancake windings. The windings of prototype transformer were wound using copper tape with the same size as BSCCO-2223 HTS tape. The core of the transformer was designed and manufactured as a shell type core made of laminated silicon steel plate. The several characteristics tests for the prototype transformer were performed in liquid nitrogen and insulation tests were accomplished also.